707.00 laying. Ensure that the outlet hole are the same size as the outlet pipe. Perform inspection at the project site. Ensure manufacturers providing materials are certified according to Supplement 1073 707 STEEL, ALUMINUM, AND PLASTIC PIPE 707.00 Acceptance. Corrugated metal pipe conforming to 707.01, 707.02, 707.03, 707.04, 707.05, 707.07, 707.11, 707.12, 707.13, 707.14, 707.15, 707.21, 707.22, 707.23, 707.24, and 707.25 may be accepted for shipment to and immediate use in construction projects when provided from suppliers certified according to Supplement 1019. 707.01 Metallic Coated Corrugated Steel Conduits and Underdrains. Provide conduits and underdrains having a corrugation depth of 1/2 or 1/4 inch (13 or 6.5 mm) and according to AASHTO M 36/M 36M, with the following modifications: 7.5 Ensure either helical lock or continuous welded seams are used. 7.7.1 Helical corrugated pipe, 12-inch (300 mm) diameter and larger, shall have at least two annular corrugations at each end of each pipe length. 726
727 707.01 8.1.2. Ensure that the minimum wall thickness (coated) of steel pipe and pipe-arches is as follows: Pipe Pipe-Arch Diameter Wall Thickness Size Wall Thickness (in) (in) (in) (in) 6 0.052 8 0.064 10 0.064 12 0.064 15 0.064 17 × 13 0.064 18 0.064 21 × 15 0.064 21 0.064 24 × 18 0.064 24 0.064 28 × 20 0.064 27 0.064 30 0.064 35 × 24 0.064 33 0.064 36 0.064 42 × 29 0.064 42 0.064 49 × 33 0.079 48 0.064 57 × 38 0.109 54 0.109 64 × 43 0.109 60 0.109 71 × 47 0.138 66 0.138 77 × 52 0.168 72 0.138 83 × 57 0.168 78 0.168 84 0.168
- Page 681 and 682: Deleterious substances shall not ex
- Page 683 and 684: 703.07 Mineral Filler. 677 703.07 A
- Page 685 and 686: B. Structural Backfill Type 2. 679
- Page 687 and 688: 681 703.14 moisture. Ensure that th
- Page 689 and 690: 683 703.1� 2. When using BOF or E
- Page 691 and 692: A. Furnish CCS, crushed gravel, cru
- Page 693 and 694: Furnish materials for Item 617 acco
- Page 695 and 696: 689 704.01 2. Type B material has a
- Page 697 and 698: 691 705.10 Furnish materials accord
- Page 699 and 700: Test Description Bond Strength (dry
- Page 701 and 702: 1. Ensure that the material meets t
- Page 703 and 704: 697 705.24 Furnish the test data, a
- Page 705 and 706: 3. 1 Pint non-absorbent container 4
- Page 707 and 708: 6.3 Provide aggregate conforming to
- Page 709 and 710: Illustrative Example of S-Stirrup S
- Page 711 and 712: 705 706.02 2. When it has been esta
- Page 713 and 714: 0.3 mm Crack D-Load 65.0 Ultimate S
- Page 715 and 716: 0.01-inch Crack D-Load 3000 Ultimat
- Page 717 and 718: 711 706.03 with elliptical reinforc
- Page 719 and 720: 706.05 class. Ensure that the marki
- Page 721 and 722: 706.05 1. All structural design acc
- Page 723 and 724: 717 706.05 handling strengths, then
- Page 725 and 726: 719 706.05 The manufacturer may be
- Page 727 and 728: 721 706.05 The spacing center-to-ce
- Page 729 and 730: 723 706.06 12.0 Make repairs accord
- Page 731: 725 706.12 Furnish materials accord
- Page 735 and 736: 729 707.02 annular corrugation that
- Page 737 and 738: 731 707.10 707.10 Square and Rectan
- Page 739 and 740: 733 707.13 9.3 A bell and spigot jo
- Page 741 and 742: 197M. Pipe Pipe-Arch Diameter Wall
- Page 743 and 744: 737 707.25 7.5.1 Reroll the ends of
- Page 745 and 746: 739 707.41 7.4 When tested in accor
- Page 747 and 748: 9.1 Perform inspection at the proje
- Page 749 and 750: 743 708.02 g. Pot life. SSPC-Paint
- Page 751 and 752: 745 708.02 36M hot rolled steel. Bl
- Page 753 and 754: 747 709.01 775, Section 11, permiss
- Page 755 and 756: 749 710.01 in round column and dril
- Page 757 and 758: 751 710.03 TABLE 710.03-1 STEEL POS
- Page 759 and 760: 753 710.03 plunger bar of the latch
- Page 761 and 762: 710.12 Furnish steel line posts acc
- Page 763 and 764: 757 711.04 ASTM A 328/A 328M. Furni
- Page 765 and 766: 759 711.13 17 Ship test bars with t
- Page 767 and 768: 761 711.23 18.7.4.5, and 18.10.3. I
- Page 769 and 770: 763 711.27 Air-dry or kiln-dry timb
- Page 771 and 772: Total calcium and magnesium oxides
- Page 773 and 774: Type A: Underdrains and Slope Drain
- Page 775 and 776: 769 712.11 5. A netting weight of a
- Page 777 and 778: 771 712.11 2. Excelsior cut from wo
- Page 779 and 780: 773 721.02 Furnish materials accord
- Page 781 and 782: 775 725.07 725.07 Plastic Pull Boxe
707.00<br />
laying. Ensure that the outlet hole are the same size as the outlet pipe. Perform<br />
inspection at the project site.<br />
Ensure manufacturers providing materials are certified according to<br />
Supplement 1073<br />
707 STEEL, ALUMINUM, AND PLASTIC PIPE<br />
707.00 Acceptance. Corrugated metal pipe conforming to 707.01, 707.02,<br />
707.03, 707.04, 707.05, 707.07, 707.11, 707.12, 707.13, 707.14, 707.15, 707.21,<br />
707.22, 707.23, 707.24, <strong>and</strong> 707.25 may be accepted for shipment to <strong>and</strong><br />
immediate use in construction projects when provided from suppliers certified<br />
according to Supplement 1019.<br />
707.01 Metallic Coated Corrugated Steel Conduits <strong>and</strong> Underdrains.<br />
Provide conduits <strong>and</strong> underdrains having a corrugation depth <strong>of</strong> 1/2 or 1/4 inch (13<br />
or 6.5 mm) <strong>and</strong> according to AASHTO M 36/M 36M, with the following<br />
modifications:<br />
7.5 Ensure either helical lock or continuous welded seams are used.<br />
7.7.1 Helical corrugated pipe, 12-inch (300 mm) diameter <strong>and</strong> larger, shall<br />
have at least two annular corrugations at each end <strong>of</strong> each pipe length.<br />
726