706.02<br />

0.3 mm Crack D-Load 140.0<br />

Ultimate Strength D-Load 175.0<br />

Internal<br />

Diameter Wall<br />

<strong>of</strong> Pipe<br />

mm<br />

Thickness<br />

mm<br />

Circular Reinforcement<br />

in Circular Pipe<br />

Inner Cage<br />

(cm 2 /m <strong>of</strong><br />

pipe)<br />

Outer Cage<br />

(cm 2 /m <strong>of</strong> pipe)<br />

TABLE 706.02-4M<br />

S-Stirrups<br />

Minimum Area<br />

Per Support<br />

Element<br />

(mm 2 )<br />

710<br />

Number<br />

<strong>of</strong> Lines [1]<br />

Circumferential Minimum<br />

Longitudinal Spacing on Amplitude<br />

Spacing Inner Cage<br />

(mm) (mm)<br />

[2]<br />

<strong>of</strong> Stirrups<br />

(mm)<br />

Concrete Strength 41.4 MPa<br />

150 44 1.5 --<br />

200 44 1.5 --<br />

250 44 1.5 --<br />

1350 138 18.2 13.1<br />

1500 150 20.1 14.4<br />

Concrete Strength 34.5 MPa<br />

1350 138 13.5 10.2 19 15 50 54 67<br />

1500 150 14.8 11.2 19 14 50 37 79<br />

1650 163 16.7 12.5 19 13 50 79 92<br />

1800 175 18.4 14.0 19 12 50 92 105<br />

1950 188 19.5 14.6 20 11 50 105 117<br />

2100 200 21.0 15.7 22 11 50 117 130<br />

2250 200 23.9 18.0 26 11 50 117 130<br />

2400 213 25.4 19.1 29 11 50 130 143<br />

2550 213 28.4 21.2 34 11 50 130 143<br />

2700 225 32.0 23.9 41 11 50 143 156<br />

2850 238 32.0 23.9 41 11 50 156 168<br />

3000 250 34.3 25.6 44 11 50 165 181<br />

3150 263 36.6 27.5 46 11 50 175 194<br />

3200 275 38.9 29.2 49 11 50 184 206<br />

3600 300 44.2 33.2 55 11 50 203 232<br />

[1] Refer to Footnote for Table 706.02-2M.<br />

[2] Refer to Footnote for Table 706.02-2M.<br />

11.1 Perform compression tests on cores according to ASTM C 497 (ASTM<br />

C 497M).<br />

11.3 Does not apply.<br />

12 Perform inspection at the project site. Obtain r<strong>and</strong>om samples from<br />

material delivered to the project site or at other locations designated by the<br />

Laboratory.<br />

16 Furnish materials from suppliers certified according to Supplement 1074.<br />

17 In addition, after the capital letter “D,” designate the D-load, the design<br />

wall thickness in millimeters (inches expressed as a decimal). Ensure that pipe<br />

with S-stirrups have the symbol “S”. Ensure that pipe requiring axis orientation<br />

without lift holes (i.e., stirrup pipe, quadrant reinforced pipe, elliptically reinforced<br />

pipe) has the centerline <strong>of</strong> the crown <strong>of</strong> the pipe marked inside <strong>and</strong> outside with<br />

the symbol “TB”. Mark pipe with quadrant steel with the symbol “Q”. Mark pipe