Illustrative Example <strong>of</strong> S-Stirrup Support System for 0.3 mm Crack D<br />

2550 mm diameter Pipe Minimum Area per Support 34 mm 2 Stirrup Support System for 0.3 mm Crack D-Load 140.0,<br />

, 11 Lines Spaced @ 128 mm.<br />

For other classes <strong>and</strong> sizes, see Tables 706.02-2M, 2M, 3M, <strong>and</strong> 4M.<br />

0.01-inch Crack D-Load 1000<br />

Ultimate Strength D-Load 1500<br />

Internal<br />

Diameter <strong>of</strong><br />

Pipe<br />

Wall<br />

Thickness<br />

(in)<br />

TABLE 706.02-1<br />

Circular Reinforcement in Circular Pipe<br />

Inner Cage<br />

(in)<br />

(in 2 Outer Cage<br />

/ft <strong>of</strong> pipe) (in 2 /ft <strong>of</strong> pipe)<br />

Reinforcing Steel 709.11 or 709.12 Only<br />

Concrete Strength 4000 psi<br />

36 4 0.09 0.07<br />

42 4 1/2 0.11 0.08<br />

48 5 0.13 0.09<br />

54 5 1/2 0.16 0.12<br />

60 6 0.19 0.14<br />

66 6 1/2 0.21 0.16<br />

72 7 0.23 0.17<br />

78 7 1/2 0.25 0.19<br />

84 8 0.29 0.21<br />

90 8 0.33 0.24<br />

96 8 1/2 0.37 0.26<br />

Concrete Strength 5000 psi<br />

102 8 1/2 0.41 0.28<br />

108 9 0.47 0.3<br />

All Permitted Reinforcing Steel<br />

Concrete Strength 5000 psi<br />

114 9 1/2 0.56 0.42<br />

120 10 0.61 0.46<br />

126 10 1/2 0.65 0.49<br />

132 11 0.7 0.52<br />

144 12 0.8 0.6<br />

703<br />

706.02