700.00<br />

Spec No. <strong>Material</strong> <strong>Material</strong> only Inspection or Sampling<br />

Requirements<br />

Post Inspection Instructions<br />

748.05 Copper Service Verify type <strong>and</strong> br<strong>and</strong> name <strong>of</strong> material is on Notify District Testing if rejecting<br />

Branches <strong>and</strong> QPL at the time <strong>of</strong> use.<br />

material.<br />

Fittings<br />

Inspect for condition, dimension, suitability for If material non-performs or looks<br />

intended use.<br />

defective during use notify District<br />

Document in CMS (Trns.port SiteManager ). Testing <strong>and</strong> OMM.<br />

748.06 Steel Pipe Basis <strong>of</strong> acceptance is certified test data Notify District Testing if rejecting<br />

Encasement containing documentation <strong>of</strong> domestic origin<br />

from manufacturer.<br />

material<br />

748.07 Polyethylene Verify manufacturer certification conforms to Notify District Testing if rejecting<br />

Encasement ANSI/AWWA C105/A21.5<br />

Inspect condition, dimension, suitability for<br />

intended use.<br />

material.<br />

748.08 Gate Valve <strong>and</strong> Verify type <strong>and</strong> br<strong>and</strong> name <strong>of</strong> material is on Notify District Testing if rejecting<br />

Valve Box QPL at the time <strong>of</strong> use.<br />

material.<br />

Inspect for condition, dimension, suitability for If material non-performs or looks<br />

intended use.<br />

defective during use notify District<br />

Document in CMS (Trns.port SiteManager ). Testing <strong>and</strong> OMM.<br />

748.09 Inserting Valve <strong>and</strong> Verify type <strong>and</strong> br<strong>and</strong> name <strong>of</strong> material is on Notify District Testing if rejecting<br />

Valve Box QPL at the time <strong>of</strong> use.<br />

material.<br />

Inspect for condition, dimension, suitability for If material non-performs or looks<br />

intended use.<br />

defective during use notify District<br />

Document in CMS (Trns.port SiteManager ). Testing <strong>and</strong> OMM.<br />

748.10 Cutting-in Sleeve, Verify type <strong>and</strong> br<strong>and</strong> name <strong>of</strong> material is on Notify District Testing if rejecting<br />

Valve, <strong>and</strong> Valve QPL at the time <strong>of</strong> use.<br />

material.<br />

Box<br />

Inspect for condition, dimension, suitability for If material non-performs or looks<br />

intended use.<br />

defective during use notify District<br />

Document in CMS (Trns.port SiteManager ). Testing <strong>and</strong> OMM.<br />

748.11 Tapping Sleeve, Verify type <strong>and</strong> br<strong>and</strong> name <strong>of</strong> material is on Notify District Testing if rejecting<br />

Valve, <strong>and</strong> Valve QPL at the time <strong>of</strong> use.<br />

material.<br />

Box<br />

Inspect for condition, dimension, suitability for If material non-performs or looks<br />

intended use.<br />

defective during use notify District<br />

Document in CMS (Trns.port SiteManager ). Testing <strong>and</strong> OMM.<br />

748.12 Tapping Saddle <strong>and</strong> Verify type <strong>and</strong> br<strong>and</strong> name <strong>of</strong> material is on Notify District Testing if rejecting<br />

Corporation Stop QPL at the time <strong>of</strong> use.<br />

material.<br />

Inspect for condition, dimension, suitability for If material non-performs or looks<br />

intended use.<br />

defective during use notify District<br />

Document in CMS (Trns.port SiteManager ). Testing <strong>and</strong> OMM.<br />

748.13 Service Stop <strong>and</strong> Verify type <strong>and</strong> br<strong>and</strong> name <strong>of</strong> material is on Notify District Testing if rejecting<br />

Service Box QPL at the time <strong>of</strong> use.<br />

material.<br />

Inspect for condition, dimension, suitability for If material non-performs or looks<br />

intended use.<br />

defective during use notify District<br />

748.14<br />

Document in CMS (Trns.port SiteManager ). Testing <strong>and</strong> OMM.<br />

Meter, Setting, Stop, Inspect for condition, dimension, suitability for<br />

<strong>and</strong> Chamber intended use.<br />

Acceptance based on manufacturer’s statement<br />

<strong>of</strong> conformity.<br />

748.15 Fire Hydrant Verify type <strong>and</strong> br<strong>and</strong> name <strong>of</strong> material is on Notify District Testing if rejecting<br />

QPL at the time <strong>of</strong> use.<br />

material.<br />

Inspect for condition, dimension, suitability for If material non-performs or looks<br />

intended use.<br />

defective during use notify District<br />

Document in CMS (Trns.port SiteManager ). Testing <strong>and</strong> OMM.