700.00<br />

Spec No. <strong>Material</strong> <strong>Material</strong> only Inspection or Sampling<br />

Requirements<br />

Post Inspection Instructions<br />

711.21 Preformed Bearing Verify type <strong>and</strong> br<strong>and</strong> name <strong>of</strong> material is on If material non-performs or looks<br />

Pads<br />

QPL at the time <strong>of</strong> use.<br />

defective during use notify District<br />

Inspect for condition <strong>and</strong> defect.<br />

Verify dimension conform to plan<br />

requirements.<br />

Document in CMS (Trns.port SiteManager ).<br />

Testing <strong>and</strong> OMM.<br />

711.23 Elastomeric Only accept elastomeric bearings shipped by Field acceptable for durometer.<br />

Bearings<br />

TE-24.<strong>and</strong> provided by certified suppliers Reading average range: +/- 7<br />

conforming to S1081. Notify district testing.<br />

to Inspect material to check location <strong>and</strong><br />

number <strong>of</strong> internal shims utilizing an ice pick<br />

or similar tool.<br />

Five (5) Durometer Gage readings should be<br />

taken <strong>and</strong> averaged to determine compliance<br />

with design plans.<br />

Document in CMS (Trns.port SiteManager ).<br />

points <strong>of</strong> design plan number.<br />

711.24 Waterpro<strong>of</strong>ing fabric Verify type <strong>and</strong> br<strong>and</strong> name <strong>of</strong> material is on Notify District Testing if rejecting<br />

QPL at the time <strong>of</strong> use.<br />

Inspect for condition <strong>and</strong> defect.<br />

Verify dimension conform to plan<br />

requirements.<br />

Document in CMS (Trns.port SiteManager ).<br />

material.<br />

711.25 Type 2 Membrane Verify type <strong>and</strong> br<strong>and</strong> name <strong>of</strong> material is on Notify District Testing if rejecting<br />

Waterpro<strong>of</strong>ing QPL at the time <strong>of</strong> use.<br />

material.<br />

Inspect for condition <strong>and</strong> defect.<br />

If material non-performs or looks<br />

Verify dimension conform to plan<br />

defective during use send one (1) 4<br />

requirements.<br />

ft<br />

Document in CMS (Trns.port SiteManager ).<br />

2 sample representative <strong>of</strong> defect<br />

to OMM for QA follow-up.<br />

711.26 Structural Timber, Products will be supplied by a source on the Notify District Testing <strong>and</strong> OMM,<br />

Lumber <strong>and</strong> Piling Certified List for S-1072 maintained by OMM. structural welding <strong>and</strong> metals<br />

Received with TE-24 <strong>and</strong> supplier bill <strong>of</strong> section, if rejecting material<br />

lading.<br />

because material non-performs or<br />

Check dimension, quantity <strong>and</strong> condition.<br />

Document in CMS (Trns.port SiteManager ).<br />

looks defective during use.<br />

711.27 Prestressing Steel <strong>Material</strong> supplied by a Fabricator source on the If questions concerning prstressed<br />

Certified List for Items 515 maintained by<br />

OMM.<br />

Prestressed Concrete Members are received<br />

with TE-24.<br />

concrete or prestressed<br />

711.28 Cellular Polyvinyl Verify type <strong>and</strong> br<strong>and</strong> name <strong>of</strong> material is on Notify District Testing if rejecting<br />

Chloride Sponge QPL at the time <strong>of</strong> use.<br />

material.<br />

Inspect for condition <strong>and</strong> defect.<br />

If material non-performs or looks<br />

Verify dimension conform to plan<br />

defective during use send<br />

requirements.<br />

one (1) 1.5'x2.5' sample<br />

Document in CMS (Trns.port SiteManager ). representative <strong>of</strong> defect to OMM<br />

for QA follow-up.<br />

711.29 Type 3 Membrane Verify type <strong>and</strong> br<strong>and</strong> name <strong>of</strong> material is on Notify District Testing if rejecting<br />

Waterpro<strong>of</strong>ing QPL at the time <strong>of</strong> use.<br />

material.<br />

Membrane primer is 705.04 material If material non-performs or looks<br />

Inspect for condition <strong>and</strong> defect.<br />

defective during use send<br />

Verify dimension conform to plan<br />

one (1) 4 square ft sample<br />

requirements.<br />

representative <strong>of</strong> defect to OMM<br />

Document in CMS (Trns.port SiteManager ). for QA follow-up.<br />

711.30 Aluminum for Steps Verify type <strong>and</strong> br<strong>and</strong> name <strong>of</strong> material is on Notify District Testing <strong>and</strong> OMM,<br />

QPL at the time <strong>of</strong> use.<br />

structural welding <strong>and</strong> metals<br />

Inspect for condition <strong>and</strong> defect.<br />

section, if rejecting material<br />

Verify dimension conform to plan<br />

because material non-performs or<br />

requirements.<br />

Document in CMS (Trns.port SiteManager ).<br />

looks defective during use.<br />

711.31 Reinforced Verify type <strong>and</strong> br<strong>and</strong> name <strong>of</strong> material is on Notify District Testing <strong>and</strong> OMM,<br />

Propylene Plastic QPL at the time <strong>of</strong> use.<br />

structural welding <strong>and</strong> metals<br />

Manhole Steps Inspect for condition <strong>and</strong> defect.<br />

section, if rejecting material<br />

Verify dimension conform to plan<br />

because material non-performs or<br />

requirements.<br />

Document in CMS (Trns.port SiteManager ).<br />

looks defective during use.<br />

646