637<br />

700.00<br />

Spec No. <strong>Material</strong> <strong>Material</strong> only Inspection or Sampling<br />

Requirements<br />

Post Inspection Instructions<br />

705.10 Air Entraining Verify type <strong>and</strong> br<strong>and</strong> name <strong>of</strong> material listed Storage: Admixtures should be<br />

Admixtures on Concrete Plant Batch Ticket is on QPL at stored at concrete producer in such<br />

the time <strong>of</strong> use.<br />

a manner to permit easy access for<br />

Document in CMS (Trns.port SiteManager ). proper identification in weather<br />

resistant units.<br />

Provide minimum QA sample <strong>of</strong><br />

one (1) every 180 days per<br />

concrete plant, each material, each<br />

company. Minimum sample size<br />

one (1) quart<br />

705.11 Joint Sealer Verify type <strong>and</strong> br<strong>and</strong> name <strong>of</strong> material is on Notify District Testing if rejecting<br />

Preformed QPL at the time <strong>of</strong> use.<br />

material because material non-<br />

Elastomeric Inspect for condition, appearance, dimension performs or looks defective during<br />

<strong>and</strong> manufacturer trademark.<br />

Document in CMS (Trns.port SiteManager ).<br />

use.<br />

705.12 Chemical<br />

Verify type <strong>and</strong> br<strong>and</strong> name <strong>of</strong> material is on Storage: Admixtures should be<br />

Admixtures for QPL at the time <strong>of</strong> use.<br />

stored at concrete producer in such<br />

Concrete<br />

Document in CMS (Trns.port SiteManager ). a manner to permit easy access for<br />

proper identification in weather<br />

resistant units.<br />

Provide minimum QA sample <strong>of</strong><br />

one (1) every 180 days per<br />

concrete plant, each material, each<br />

company. Minimum sample size<br />

one (1) quart.<br />

705.15 High Molecular Verify type <strong>and</strong> br<strong>and</strong> name <strong>of</strong> material is on<br />

Weight Methacrylate QPL at the time <strong>of</strong> use.<br />

(HMWM) Document in CMS (Trns.port SiteManager ).<br />

705.20 Non Shrink, Non<br />

Metallic Grout<br />

705.21 Quick Setting<br />

Concrete Mortar<br />

Verify type <strong>and</strong> br<strong>and</strong> name <strong>of</strong> material is on Notify District Testing if rejecting<br />

QPL at the time <strong>of</strong> use. Ensure mixing is material.<br />

performed in accordance with manufacturer’s If material non-performs or looks<br />

recommendations on the container.<br />

defective during use notify District<br />

Document in CMS (Trns.port SiteManager ). Testing <strong>and</strong> OMM for sampling<br />

requirements.<br />

Verify type <strong>and</strong> br<strong>and</strong> name <strong>of</strong> material is on Notify District Testing if rejecting<br />

QPL at the time <strong>of</strong> use. Ensure mixing is material.<br />

performed in accordance with manufacturer’s If material non-performs or looks<br />

recommendations on the container.<br />

defective during use notify District<br />

Document in CMS (Trns.port SiteManager ). Testing <strong>and</strong> OMM for sampling<br />

requirements.<br />

705.22 Non-shrink Mortar Verify manufacturer is on the Approved List Sample will be tested at 3, 7 <strong>and</strong><br />

maintained by OMM. Ensure mixing is 28 days.<br />

performed in accordance with manufacturer’s Do not open structure to traffic<br />

recommendations on the container. Make three until a compressive strength <strong>of</strong><br />

(3) or more 3"x6" cylinders from keyway mix.<br />

Ship to OMM Concrete Section.<br />

Document in CMS (Trns.port SiteManager ).<br />

5000 psi (34.5 MPa) is achieved.<br />

705.23 A Epoxy-urethane<br />

Sealers<br />

Verify type <strong>and</strong> br<strong>and</strong> name <strong>of</strong> material is on Notify District Testing if rejecting<br />

QPL at the time <strong>of</strong> use.<br />

material.<br />

Ensure mixing is performed in accordance with If material non-performs or looks<br />

manufacturer’s recommendations on the defective during use obtain 1 qt (1<br />

container.<br />

L) samples in a sealed container<br />

Document in CMS (Trns.port SiteManager ). <strong>and</strong> send to OMM.<br />

705.23 B Non Epoxy Sealers Verify type <strong>and</strong> br<strong>and</strong> name <strong>of</strong> material is on Notify District Testing if rejecting<br />

QPL at the time <strong>of</strong> use.<br />

material.<br />

Ensure mixing is performed in accordance with If material non-performs or looks<br />

manufacturer’s recommendations on the defective during use obtain 1 qt (1<br />

container.<br />

L) samples in a sealed container<br />

Document in CMS (Trns.port SiteManager ). <strong>and</strong> send to OMM.<br />

705.24 Soluble Reactive<br />

Silicate<br />

Verify type <strong>and</strong> br<strong>and</strong> name <strong>of</strong> material is on Notify District Testing if rejecting<br />

QPL at the time <strong>of</strong> use.<br />

material.<br />

Ensure mixing is performed in accordance with<br />

manufacturer’s recommendations on the<br />

container.<br />

Document in CMS (Trns.port SiteManager ).

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!