700.00<br />

Spec No. <strong>Material</strong> <strong>Material</strong> only Inspection or Sampling<br />

Requirements<br />

Post Inspection Instructions<br />

703.18 Aggregate for Items Products will be supplied by a supplier on the No additional project sampling<br />

410, 411, <strong>and</strong> Pre-Qualified Supplier List for S 1069 required for approved, sampled<br />

617from Non- maintained by OMM.<br />

tonnage except if project believes<br />

Certified Stock 90 to 100 lb. QC sample taken from each 5200 there is a problem with the<br />

ton (4720 metric ton) stockpile, submitted to material [either gradation or<br />

OMM Aggregate Section.<br />

Document in CMS (Trns.port SiteManager<br />

)..<br />

Do not use until tested <strong>and</strong> approved.<br />

quality]<br />

703.19.A Crushed Aggregate Products will be supplied by a supplier on the No sampling required except if<br />

Slope Protection <strong>and</strong> Pre-Qualified Supplier List for S 1069 project believes there is a problem<br />

Filter Aggregate for maintained by OMM.<br />

with the material [either gradation<br />

Dump Rock Fill Document in CMS (Trns.port SiteManager ). or quality]<br />

703.19.B Dumped Rock Fill<br />

<strong>and</strong> Rock Channel<br />

Protection<br />

704.01<br />

704.02<br />

704.03<br />

Block:<br />

Brick<br />

Concrete Masonry<br />

Shale<br />

705.01 Fiber Reinforced<br />

Polymer (FRP)<br />

Dowel Bars<br />

705.03 Joint Filler<br />

Preformed<br />

705.04 Joint <strong>and</strong> Crack<br />

Sealer<br />

Hot Applied<br />

705.05 Burlap Cloth<br />

<strong>Material</strong>s<br />

705.06 Sheet Curing<br />

<strong>Material</strong>s<br />

705.07 Concrete Curing<br />

Compounds<br />

Products will be supplied by a supplier on the<br />

Pre-Qualified Supplier List for S 1069<br />

maintained by OMM.<br />

Confirm with OMM laboratory source has<br />

know durability history<br />

Sample on direction <strong>of</strong> the OMM laboratory<br />

Document in CMS (Trns.port SiteManager ).<br />

636<br />

No sampling required except if<br />

project believes there is a problem<br />

with the material [either gradation<br />

or quality]<br />

Verify type <strong>of</strong> material is on QPL at the time <strong>of</strong> Notify District Testing if rejecting<br />

use.<br />

material.<br />

Inspect for condition <strong>and</strong> defects.<br />

When material non-performs or<br />

Document in CMS (Trns.port SiteManager ). looks defective during use reject<br />

material <strong>and</strong> sample 12 brick<br />

representative <strong>of</strong> defect to OMM<br />

for QA follow-up.<br />

Certified test data from an accredited testing<br />

facility will accompany each shipment.<br />

Document in CMS (Trns.port SiteManager ).<br />

Notify District Testing upon<br />

receipt <strong>of</strong> shipment.<br />

Verify type <strong>and</strong> br<strong>and</strong> name <strong>of</strong> material is on Notify District Testing if rejecting<br />

QPL at the time <strong>of</strong> use.<br />

material.<br />

Inspect for condition, appearance <strong>and</strong> If material non-performs or looks<br />

dimension.<br />

defective during use send one (1)<br />

Document in CMS (Trns.port SiteManager ). 1.5'x2.5' sample representative <strong>of</strong><br />

defect to OMM for QA follow-up.<br />

<strong>Material</strong> is pre-tested <strong>and</strong> approved.<br />

Notify District Testing if rejecting<br />

Will be shipped with TE-24.<br />

material.<br />

Document in CMS (Trns.port SiteManager ). If material non-performs or looks<br />

defective during use notify District<br />

Testing <strong>and</strong> OMM Asphalt Section<br />

for sampling requirements.<br />

Inspect for condition, appearance <strong>and</strong><br />

dimension.<br />

Documenting in CMS (Trns.port SiteManager<br />

) .is not required<br />

Only sample if there if questioning material<br />

meet specification<br />

Inspect for condition, appearance <strong>and</strong><br />

dimension.<br />

Documenting in CMS (Trns.port SiteManager<br />

) is not required.<br />

Only sample if there if questioning material<br />

meet specification<br />

Notify District Testing if rejecting<br />

material.<br />

If material non-performs or looks<br />

defective during use notify District<br />

Testing <strong>and</strong> OMM.<br />

Notify District Testing if rejecting<br />

material.<br />

If material non-performs or looks<br />

defective during use notify District<br />

Testing <strong>and</strong> OMM.<br />

Verify type <strong>and</strong> br<strong>and</strong> name <strong>of</strong> material is on Notify District Testing if rejecting<br />

QPL at the time <strong>of</strong> use.<br />

material.<br />

Inspect for condition <strong>and</strong> appearance. If material non-performs or looks<br />

Document in CMS (Trns.port SiteManager ). defective during use send one (1)<br />

quart sample representative <strong>of</strong><br />

defect to OMM, Cement <strong>and</strong><br />

Concrete section, for QA followup.