631<br />

700.00<br />

Spec No. <strong>Material</strong> <strong>Material</strong> only Inspection or Sampling<br />

Requirements<br />

Post Inspection Instructions<br />

515.15 Prestressed Concrete Verify company <strong>and</strong> br<strong>and</strong> name <strong>of</strong> material is For Precast beams delivered on<br />

Bridge Members - on QPL at the time <strong>of</strong> use. Document in CMS TE-24, verification performed by<br />

Corrosion Inhibitors (Trns.port SiteManager ).<br />

OMM.<br />

526 Approach Slabs Make 6"x12" cylinders for each day, each 200 Within 24 to 48 hours after<br />

yd³. Document in CMS (Trns.port SiteManager sampling, ship cylinders to<br />

). Make two beams if testing before 7 days. Laboratory with required<br />

Field or St<strong>and</strong>ard Cure according to<br />

ACI/ODOT specifications.<br />

documentation.<br />

601.12 Tied Concrete Block Verify company <strong>and</strong> br<strong>and</strong> name <strong>of</strong> material is Notify District Testing if rejecting<br />

Mats<br />

on QPL at the time <strong>of</strong> use. Ensure proper type material.<br />

(Slope/Channel <strong>and</strong> inspect material for condition.<br />

If material non-performs or looks<br />

Protection) Document in CMS (Trns.port SiteManager ). defective during use submit a<br />

representative qty <strong>of</strong> defective<br />

material to the Laboratory.<br />

603.02 External Sealing Verify company <strong>and</strong> br<strong>and</strong> name <strong>of</strong> material is Notify District Testing if rejecting<br />

B<strong>and</strong>s Joint Wrap on QPL at the time <strong>of</strong> use. Inspect material for material.<br />

condition.<br />

If material non-performs or looks<br />

609.02 Curbing, Concrete<br />

Document in CMS (Trns.port SiteManager ). defective during use submit a<br />

representative qty <strong>of</strong> defective<br />

material to the OMM.<br />

Contact District Testing <strong>and</strong> OMM Aggregate<br />

Medians, <strong>and</strong> Traffic Section to assure stone curb conforms to<br />

Isl<strong>and</strong>s - Stone<br />

Curbs<br />

requirements <strong>of</strong> 609.02<br />

610 Cellular Retaining 610.04.A Cellular Products will be supplied by Notify District Testing if rejecting<br />

Walls<br />

a source on the Certified Lists for S-1073 material.<br />

maintained by OMM.<br />

If material non-performs or looks<br />

Received with TE-24.<br />

defective during use notify District<br />

Check dimension, condition <strong>and</strong> compliance<br />

with approved drawings.<br />

610.04.B Cellular Products accept by certified<br />

test data documentation at the Project .<br />

Document in CMS (Trns.port SiteManager ).<br />

Testing <strong>and</strong> OMM.<br />

613 Low Strength Mortar<br />

Backfill<br />

632.11 Traffic Signal<br />

Equipment<br />

Loop Detector<br />

Sealant<br />

633 Traffic Signal<br />

Controllers<br />

653.02<br />

Supplier to perform trial batches <strong>of</strong> 1 cy to<br />

ensure flowable consistency <strong>and</strong> yield.<br />

Refer to Item 613.05 for alternate mix design.<br />

Alternate mix designs will be submitted for<br />

approval 30 days prior to placement.. Submit<br />

written permission form to EPA 10 days prior<br />

to placement.<br />

Notify District Testing if rejecting<br />

material.<br />

If material non-performs or looks<br />

defective during use notify District<br />

Testing <strong>and</strong> OMM.<br />

Verify manufacturer is on QPL.<br />

Notify District Testing if rejecting<br />

Inspect for condition, appearance <strong>and</strong> package material.<br />

markings.<br />

If material non-performs or looks<br />

Document in CMS (Trns.port SiteManager ). defective during use notify District<br />

Testing <strong>and</strong> OMM.<br />

Inspect material for condition <strong>and</strong> conformance Notify District Testing if rejecting<br />

to shop drawings.<br />

material.<br />

Manufacturer’s certified test data required for<br />

acceptance.<br />

Refer to H<strong>and</strong>book <strong>of</strong> Procedures for<br />

Contractor Certification <strong>of</strong> Lighting, Signing &<br />

Traffic Signal Working Drawings on OMM<br />

Manual website.<br />

Topsoil Obtain one (1) pint sample <strong>of</strong> material from<br />

each source <strong>and</strong>/or stockpile <strong>of</strong> visually<br />

different material from same source.<br />

Use friction top, air tight metal container<br />

supplied by the <strong>Department</strong>.<br />

Submit to Office <strong>of</strong> Geotechnical Engineering<br />

Operations.<br />

Samples will include a TE-31 form or CMS<br />

(Trns.port SiteManager ) print screen<br />

657.02 RipRap for Tree<br />

Protection<br />

Confirm with DET that the aggregate source<br />

has a acceptable performance history. For<br />

sources with poor performance require test data<br />

conforming to ASTM D5240