638.19<br />

without the use <strong>of</strong> extensions provided that ample thread remains on the box to<br />

provide adequate rigidity to the box. Provide extension sections for boxes that are<br />

not <strong>of</strong> the screw-type <strong>and</strong> boxes not having ample thread for rigidity to adjust the<br />

top to grade. The Engineer will allow inserts or adapters. Adequately secure new<br />

sections <strong>of</strong> box stem to the existing stems. Backfill the hole after the box has been<br />

adjusted to grade.<br />

638.19 Method <strong>of</strong> Measurement. The <strong>Department</strong> will measure Water Main,<br />

Ductile Iron Pipe <strong>and</strong> Water Main, Polyvinyl Chloride Pipe <strong>and</strong> Fittings by the<br />

number <strong>of</strong> feet (meters) <strong>of</strong> each constructed.<br />

The <strong>Department</strong> will measure Copper Service Branch, Polyethylene Service<br />

Branch, <strong>and</strong> Polybutylene Service Branch by the number <strong>of</strong> feet (meters) <strong>of</strong> each<br />

constructed.<br />

The <strong>Department</strong> will measure Polyethylene Encasement by the number <strong>of</strong> feet<br />

(meters) <strong>of</strong> covered pipe.<br />

The <strong>Department</strong> will measure Steel Pipe Encasement by the number <strong>of</strong> feet<br />

(meters) constructed, including the open cut or boring or jacking operation,<br />

encasement pipe, bedding <strong>and</strong> backfill, blocking to support the internal main, <strong>and</strong><br />

end bulkheads.<br />

The <strong>Department</strong> will measure Gate Valve <strong>and</strong> Valve Box; Inserting Valve <strong>and</strong><br />

Valve Box; Cutting-In Sleeve, Valve <strong>and</strong> Valve Box; Tapping Sleeve, Valve <strong>and</strong><br />

Valve Box; <strong>and</strong> Meter, Setting, Stop <strong>and</strong> Chamber separately as a complete item<br />

by the number <strong>of</strong> each.<br />

The <strong>Department</strong> will measure Fire Hydrant, Fire Hydrant Extended <strong>and</strong><br />

Adjusted to Grade, Fire Hydrant Adjusted to Grade, Fire Hydrant Removed <strong>and</strong><br />

Reset, Fire Hydrant <strong>and</strong> Gate Valve Removed <strong>and</strong> Reset, <strong>and</strong> Fire Hydrant<br />

Removed <strong>and</strong> Disposed Of separately by the number <strong>of</strong> each.<br />

The <strong>Department</strong> will measure Valve Box Adjusted to Grade <strong>and</strong> Service Box<br />

Adjusted to Grade separately by the number <strong>of</strong> each, including any extension<br />

sections <strong>of</strong> valve or service boxes required.<br />

The <strong>Department</strong> will measure Meter <strong>and</strong> Chamber Removed <strong>and</strong> Reset by the<br />

number <strong>of</strong> each.<br />

The <strong>Department</strong> will measure Sheeting <strong>and</strong> Bracing Ordered Left In Place in<br />

thous<strong>and</strong>s <strong>of</strong> board feet, MBF (cubic meters).<br />

638.20 Basis <strong>of</strong> Payment. The <strong>Department</strong> will pay for accepted quantities at<br />

the contract unit prices as follows:<br />

Item Unit Description<br />

638 Foot (Meter) ___ inch (___ mm) Water Main,<br />

Ductile Iron Pipe, ANSI Class___,<br />

(push-on, mechanical, boltless- restrained,<br />

ball-<strong>and</strong>-socket) Joints <strong>and</strong> Fittings<br />

638 Foot (Meter) ___ inch (___ mm) Water Main,<br />

Polyvinyl Chloride Pipe <strong>and</strong> Fittings,<br />

ASTM SAR ___ or AWWA Class ___<br />

570