632.10<br />

pushbutton mounted on wooden poles through conduit. Furnish pedestrian<br />

pushbutton signs <strong>of</strong> the legend <strong>and</strong> size required.<br />

632.10 Loop Detector Unit. Install <strong>and</strong> tune detector units to their loops with<br />

the sensitivity set for optimum operation <strong>and</strong> any interference or cross talk<br />

eliminated between other detector units in the cabinet. Perform a field check to<br />

ensure that no extraneous detections are occurring by observing each detector<br />

unit’s operation to determine that a signal occurs only when a vehicle enters its<br />

associated loop. If actuations are observed when there is no vehicle in the loop,<br />

eliminate the extraneous detections.<br />

632.11 Detector Loop. Saw slots in the pavement for installation <strong>of</strong> vehicle<br />

detector loop wire in the configuration, dimensions, <strong>and</strong> combinations required.<br />

Cut an extension from the loop to the pavement edge to allow wire routing to an<br />

adjacent pull box.<br />

Furnish slots 1/16 to 1/8-inch (1.6 to 3 mm) wider than the outside diameter <strong>of</strong><br />

the loop wire or tubing. Ensure that the slot depth provides a covering <strong>of</strong> not less<br />

than 3/4-inch (19 mm) above the uppermost detector wire tubing after the loop<br />

installation is completed. Before installing loop detector wire, brush <strong>and</strong> blow all<br />

slots clean <strong>of</strong> loose material <strong>and</strong> completely dry. Install loop detector wire<br />

according to 632.23.<br />

Fill the slots completely with a flexible embedding sealant, prequalified<br />

according to Supplement 1048. Do not disturb slots until sealant has cured. Cured<br />

sealant shall be level with or higher than the pavement surface.<br />

For loop detector wire installations in new asphalt, the Contractor may saw slots<br />

<strong>and</strong> embed sealant in a subsurface course with subsequent covering by the surface<br />

course, subject to the Engineer’s approval.<br />

632.14 Foundations. Locate support foundations, <strong>and</strong> stake with the proper<br />

elevation. If underground or overhead obstacles are encountered during stakeout,<br />

or to correct slope <strong>and</strong> subsurface difficulties, change foundation location <strong>and</strong><br />

orientation with the approval <strong>of</strong> the Engineer. Ensure that the approved location<br />

provides a safe clearance from overhead power lines for construction operations, in<br />

compliance with the National Electric Safety Code. The Contractor is responsible<br />

for the correct location, elevation, <strong>and</strong> orientation for all poles <strong>and</strong> pedestals<br />

installed on the foundations.<br />

Excavate for foundations using an earth auger to specified dimensions<br />

according to 503.04. Exercise caution when excavating in areas <strong>of</strong> underground<br />

installations to avoid their disturbance or damage. When a cave-in occurs,<br />

excavate using casing, sleeving, or other methods, with the Engineer’s approval. If<br />

subsurface obstructions are encountered, remove the obstructions, or replace the<br />

excavated material <strong>and</strong> relocate the foundation, with the Engineer’s approval. If<br />

bedrock is encountered, the Contractor may reduce that portion <strong>of</strong> the specified<br />

foundation depth within the bedrock up to 50 percent. Perform all necessary<br />

dewatering <strong>of</strong> the excavation.<br />

Perform foundation concrete work according to Item 511, except that the<br />

loading restrictions in 511.17 are modified by this subsection. Place the concrete<br />

542