632.05<br />

<strong>and</strong> place two copies in a plastic envelope fastened to the inside <strong>of</strong> the controller<br />

cabinet.<br />

Identify cable <strong>and</strong> wire by tags or b<strong>and</strong>s at pull boxes <strong>and</strong> controller cabinets,<br />

with size, material, <strong>and</strong> method <strong>of</strong> marking that conform to 725.02, except ensure<br />

that the identification on the tags or b<strong>and</strong>s conforms to the wiring diagram with<br />

abbreviations according to Table 632.05-1. The Contractor may identify field<br />

wiring using an indelible pen on a plastic tag instead <strong>of</strong> embossed letters.<br />

Use spade terminals for wiring connected at signal heads <strong>and</strong> the wiring<br />

connected at terminal blocks within controller cabinets. However, for incoming<br />

power wiring, use either spade terminals or bared conductor wire connected to<br />

terminal points utilizing screw or spring applied clamping surfaces compatible<br />

with both cooper <strong>and</strong> aluminum wire <strong>and</strong> providing a positive grip. Neatly lash<br />

<strong>and</strong> fasten completed wiring to interiors with clamps <strong>and</strong>/or ties.<br />

TABLE 632.05-1 TABLE AND WIRE IDENTIFICATION<br />

Cable Tag<br />

Ground GND<br />

Power (2 wire)1∅ 120 volt AC +AC- or ACN<br />

Power (3 wire) 1∅ 120/240 volt<br />

AC + 1, AC + 2<br />

Neutral wire<br />

AC- or ACN<br />

Phase A<br />

∅ A<br />

Phase 1<br />

∅ 1<br />

Phase 1 northbound left turn lanes<br />

∅ 1 NBLT<br />

Phase A, pedestrian signal ∅ A PD<br />

Overlap, phase A + C<br />

Overlap, phase 1 + 6<br />

Detector lead-in, phase A<br />

Detector lead-in, phase 1<br />

Detector lead-in, phase 1 northbound left turn lanes<br />

Detector lead-in, phase A (call type)<br />

Detector lead-in, phase 1<br />

(call type) northbound thru lanes<br />

Detector harness [1] DET A<br />

Interconnect IC<br />

540<br />

∅ A + C<br />

∅ 1 + 6<br />

DET A<br />

DET 1<br />

DET 1 NBLT<br />

DET A CALL<br />

DET 1 CALL<br />

NB-THRU<br />

Pre-emption, fire PE FIRE<br />

Pre-emption, railroad PE RR<br />

[1] Place the tag next to the MS plug at the detector amplifier.<br />

When constructing the traffic control system, cooperate with the agency<br />

supplying the electric service. Supply 120/240 volt, single-phase, three-wire<br />

(grounded neutral) power to the disconnect switch.<br />

After completion <strong>of</strong> the 10-day performance test in compliance with 632.28 <strong>and</strong><br />

until acceptance, the Contractor is responsible for the care <strong>and</strong> maintenance <strong>of</strong><br />

traffic control equipment installed or reused as part <strong>of</strong> the Contract.