630.14 The Department will measure Overhead Sign Support by the number of each, and will include anchor bolts and conduit ells furnished for the foundation, sign attachment assemblies, sign hanger assemblies, luminaire support assemblies when required, and identification stickers when specified. The Department will measure Combination Overhead Sign Support with light pole extension by the number of each, and will include anchor bolts and conduit ells furnished for the foundation, sign attachment assemblies, sign hanger assemblies, luminaire support assemblies when required, and identification stickers when specified. Bracket arms and roadway lighting luminaires are not included. The Department will measure Sign Attachment Assembly by the number of separately itemized assemblies, and will include one overhead sign bracket, Ubolts, clamps, and miscellaneous hardware. The Department will measure Luminaire Support Assembly by the number of separately itemized assemblies, and will include one support arm, other necessary structural members, and miscellaneous hardware. The Department will measure Span Wire Sign Support by the number of each support, and will include two strain poles with span wire clamps and anchor shackles, anchor bolts and conduit ells furnished for foundations, messenger wire, clamps, thimbles, and sign hanger assemblies with hangers, braces, lengths of post, and miscellaneous hardware. The Department will measure Overpass Structure Mounted Sign Support by the number of each support, and will include attachment work and hardware, to attach one individual sign. The Department will measure Sign Hanger Assembly by the number of each, and will include all parts necessary to attach one individual sign. For pole mounted sign supports, the Department will measure Sign Support Assembly by the number of each, and will include brackets, hardware, and posts sufficient to attach each sign or set of signs to an individual pole. For bridge mounted sign supports, the Department will measure Sign Support Assembly by the number of each, and will include post, hardware, and attachment work. The Department will measure Sign by the number of square feet (square meters) of signs, and will include the furnishing of identification stickers, sign backing assemblies, mounting bolts, washers, nuts, bearing plates, clips, and rivets. For square, rectangular, circular, or irregular shaped signs, the Department will determine measurement by multiplying the largest dimensions of width and height. For triangular shaped signs, the Department will determine measurement by multiplying the largest dimension of width and one-half the largest dimension of height. The Department will include the area of the glare shields for lighted signs as an integral part of the sign. The Department will measure Sign Post Reflector by the number of each, and will include the furnishing of mounting bolts, washers and nuts. 530
630.15 The Department will measure Sign, Double-Faced by the number of each, and will include mounting fittings and hardware. The Department will measure Sign Erected by the number of square feet (square meters) of signs erected, and will include mounting hardware, the assembly of signs that are in more than one piece and the installation of required sign backing assemblies. The Department will exclude the furnishing of signs. For square, rectangular, circular, or irregular shaped signs, the Department will determine measurement by multiplying the largest dimensions of width and height. For triangular shaped signs, the Department will determine measurement by multiplying the largest dimension of width and one-half the largest dimension of height. The Department will include the area of the glare shields for lighted signs as an integral part of the sign. The Department will measure Sign Backing Assembly by the number of separately itemized assemblies, and will include back bracing for each group of flat sheet signs attached to a post or posts, or a single assembly for backing posts used to attach an exit or supplemental panel to a guide sign. The Department will measure Covering of Sign by the number of square feet (square meters) of sign face covered, and will include the subsequent removal and disposal of the covering. The Department will measure Removal and Storage, Reerection, or Disposal of Sign by the number of each sign removed and stored, re-erected or disposed of. Major signs are defined for measurement as being 40 square feet (3.7 m²) or larger. The Department will measure Removal and Storage, Reerection, or Disposal of Support by the number of each support removed and stored, re-erected or disposed of, and will include removal of foundations and restoration of surfaces. With reerection, the Department will include furnishing of anchor bolts, conduit ells, necessary field drilling, and hardware. 630.15 Basis of Payment. The Department will not pay for relocating posts from their planned location without prior approval by the engineer. The Department will pay for accepted quantities at the contract prices as follows: Item Unit Description 630 Each Ground Mounted Structural Beam Support Foundation 630 Each Ground Mounted Pipe Support Foundation 630 Each Rigid Overhead Sign Support Foundation 630 Each Span Wire Sign Support Foundation 630 Foot (Meter) Ground Mounted Support, ___ Post 630 Beam Foot (Meter) Ground Mounted Structural Beam Support, ___ 630 Foot (Meter) Ground Mounted Support, Pipe 630 Foot (Meter) Ground Mounted Wooden Box Beam Support,_____Beam 630 Foot (Meter) One-Way Support, ___ Post 630 Foot (Meter) Street Name Sign Support, ___ Post 531
- Page 485 and 486: 479 614.11 passing zone and places
- Page 487 and 488: 481 614.12 approximately 4 inches (
- Page 489 and 490: Line Type Normal Spacing Feet (Mete
- Page 491 and 492: B. Work zone signal, pole, or contr
- Page 493 and 494: 615.05 specified in Item 606, excep
- Page 495 and 496: 489 616.01 616.01 Description. This
- Page 497 and 498: TABLE 617.06-1 Material Conversion
- Page 499 and 500: 493 619.02 Furnish neat, sanitary,
- Page 501 and 502: 495 620.03 620.03 Layout. Lay out a
- Page 503 and 504: 497 621.05 When a casting is insert
- Page 505 and 506: 499 621.10 The Department will meas
- Page 507 and 508: 622.09 622.09 Basis of Payment. The
- Page 509 and 510: 624.03 Method of Measurement 624.04
- Page 511 and 512: 505 625.01 625.01 Description. This
- Page 513 and 514: 625.10 Ensure that the grounding co
- Page 515 and 516: 509 625.13 grounding conductor that
- Page 517 and 518: 511 625.16 625.16 Grounding. Connec
- Page 519 and 520: 513 625.19 Measure the earth resist
- Page 521 and 522: Pull boxes include the aggregate fo
- Page 523 and 524: 517 625.23 except for a power servi
- Page 525 and 526: 519 626.04 The Contractor may vary
- Page 527 and 528: Concrete, Class C..................
- Page 529 and 530: 523 630.04 panels to achieve the si
- Page 531 and 532: 525 630.06 galvanize steel structur
- Page 533 and 534: 527 630.07 Provide for the attachme
- Page 535: Remove temporary overlay signs so a
- Page 539 and 540: 631.08 Controls 631.09 Electrical S
- Page 541 and 542: 535 631.07 install the nipple. Ensu
- Page 543 and 544: Item Unit Description 631 Each Sign
- Page 545 and 546: 539 632.04 Ensure that major items
- Page 547 and 548: 541 632.06 Upon acceptance of the p
- Page 549 and 550: 543 632.15 against undisturbed soil
- Page 551 and 552: 545 632.23 Support cables installed
- Page 553 and 554: 547 632.28 complete test records, t
- Page 555 and 556: 549 632.30 include excavation, dewa
- Page 557 and 558: 632 Each Power Service 632 Each Cov
- Page 559 and 560: 553 633.07 1. Furnish a certified t
- Page 561 and 562: 555 633.15 and software, in one or
- Page 563 and 564: 557 633.17 5. A minimum of three ti
- Page 565 and 566: 559 633.18 potential modifications
- Page 567 and 568: 633 Each Controller, Master, Traffi
- Page 569 and 570: 563 638.03 The metric equivalent pi
- Page 571 and 572: 565 638.07 L. Thrust Blocking. Furn
- Page 573 and 574: 567 638.13 Install valve boxes on a
- Page 575 and 576: 569 638.16 it to the extended branc
- Page 577 and 578: 571 638.20 638 Foot (Meter) ___ inc
- Page 579 and 580: 573 641.03 641.03 General. Apply li
- Page 581 and 582: 575 641.05 At the end of the projec
- Page 583 and 584: 577 641.10 communication between th
- Page 585 and 586: Keep the paint thoroughly mixed dur
630.15<br />
The <strong>Department</strong> will measure Sign, Double-Faced by the number <strong>of</strong> each, <strong>and</strong><br />
will include mounting fittings <strong>and</strong> hardware.<br />
The <strong>Department</strong> will measure Sign Erected by the number <strong>of</strong> square feet (square<br />
meters) <strong>of</strong> signs erected, <strong>and</strong> will include mounting hardware, the assembly <strong>of</strong><br />
signs that are in more than one piece <strong>and</strong> the installation <strong>of</strong> required sign backing<br />
assemblies. The <strong>Department</strong> will exclude the furnishing <strong>of</strong> signs. For square,<br />
rectangular, circular, or irregular shaped signs, the <strong>Department</strong> will determine<br />
measurement by multiplying the largest dimensions <strong>of</strong> width <strong>and</strong> height. For<br />
triangular shaped signs, the <strong>Department</strong> will determine measurement by<br />
multiplying the largest dimension <strong>of</strong> width <strong>and</strong> one-half the largest dimension <strong>of</strong><br />
height. The <strong>Department</strong> will include the area <strong>of</strong> the glare shields for lighted signs<br />
as an integral part <strong>of</strong> the sign.<br />
The <strong>Department</strong> will measure Sign Backing Assembly by the number <strong>of</strong><br />
separately itemized assemblies, <strong>and</strong> will include back bracing for each group <strong>of</strong><br />
flat sheet signs attached to a post or posts, or a single assembly for backing posts<br />
used to attach an exit or supplemental panel to a guide sign.<br />
The <strong>Department</strong> will measure Covering <strong>of</strong> Sign by the number <strong>of</strong> square feet<br />
(square meters) <strong>of</strong> sign face covered, <strong>and</strong> will include the subsequent removal <strong>and</strong><br />
disposal <strong>of</strong> the covering.<br />
The <strong>Department</strong> will measure Removal <strong>and</strong> Storage, Reerection, or Disposal <strong>of</strong><br />
Sign by the number <strong>of</strong> each sign removed <strong>and</strong> stored, re-erected or disposed <strong>of</strong>.<br />
Major signs are defined for measurement as being 40 square feet (3.7 m²) or larger.<br />
The <strong>Department</strong> will measure Removal <strong>and</strong> Storage, Reerection, or Disposal <strong>of</strong><br />
Support by the number <strong>of</strong> each support removed <strong>and</strong> stored, re-erected or disposed<br />
<strong>of</strong>, <strong>and</strong> will include removal <strong>of</strong> foundations <strong>and</strong> restoration <strong>of</strong> surfaces. With<br />
reerection, the <strong>Department</strong> will include furnishing <strong>of</strong> anchor bolts, conduit ells,<br />
necessary field drilling, <strong>and</strong> hardware.<br />
630.15 Basis <strong>of</strong> Payment. The <strong>Department</strong> will not pay for relocating posts<br />
from their planned location without prior approval by the engineer.<br />
The <strong>Department</strong> will pay for accepted quantities at the contract prices as<br />
follows:<br />
Item Unit Description<br />
630 Each Ground Mounted Structural Beam Support<br />
Foundation<br />
630 Each Ground Mounted Pipe Support Foundation<br />
630 Each Rigid Overhead Sign Support Foundation<br />
630 Each Span Wire Sign Support Foundation<br />
630 Foot (Meter) Ground Mounted Support, ___ Post<br />
630<br />
Beam<br />
Foot (Meter) Ground Mounted Structural Beam Support, ___<br />
630 Foot (Meter) Ground Mounted Support, Pipe<br />
630 Foot (Meter) Ground Mounted Wooden Box Beam<br />
Support,_____Beam<br />
630 Foot (Meter) One-Way Support, ___ Post<br />
630 Foot (Meter) Street Name Sign Support, ___ Post<br />
531