CANOpen Manual
CANOpen Manual CANOpen Manual
5.2. Mechanical Data Housing Aluminum Lifetime > 10 5 h Shock (EN 60068-2-27) A=30g; t= 11ms, halfsine Vibration (EN 60068-2-6) 10 to 150 Hz, 2,5 mm amplitude, 5g const. Acceleration, Weight (standard version) 350 g Tabelle 11 Mechanical data Environmental Conditions Operating temperature -25°C.....+85°C Storage temperature -40°C.....+85°C 1 Octave /Minute (EN 60068-2-6) Humidity 98 % (without liquid state) Protection class (EN 60529) IP 67 (connected) Tabelle 12 Environmantal conditions Page 32 UME-AGS-CAN Version 09/04
5.3 Mechanical Drawings 5.3.1 Bottom View 5.3.2 Side View Version 09/04 UME-AGS-CAN Page 33
- Page 1 and 2: INCLINOMETER WITH CAN-BUS INTERFACE
- Page 3 and 4: 1. Introduction....................
- Page 5 and 6: The data communication is done via
- Page 7 and 8: 1.4 Definitions CAN Controller Area
- Page 9 and 10: 2.4 Troubleshooting 2.4.1 Power on
- Page 11 and 12: 3.1.2 The Command Byte The command
- Page 13 and 14: Index Subindex Objekt Name Datenlä
- Page 15 and 16: 3.2.3 Reset of the inclinometer If
- Page 17 and 18: 4.1.1 Programming example: Resoluti
- Page 19 and 20: 4.3 Preset Value Longitudinal The p
- Page 21 and 22: 4.4.3 Lifetime-Factor The product f
- Page 23 and 24: 4.5.2 Programming example: Heartbea
- Page 25 and 26: 4.6.1 Example: Changing the node nu
- Page 27 and 28: The changing of the baudrate is con
- Page 29 and 30: Inclinometer to Master: Confirmatio
- Page 31: 4.10 Restore default parameters The
- Page 35 and 36: Installation hints Both the cable s
5.2. Mechanical Data<br />
Housing Aluminum<br />
Lifetime > 10 5 h<br />
Shock (EN 60068-2-27) A=30g; t= 11ms, halfsine<br />
Vibration (EN 60068-2-6) 10 to 150 Hz, 2,5 mm amplitude, 5g const. Acceleration,<br />
Weight (standard version) 350 g<br />
Tabelle 11 Mechanical data<br />
Environmental Conditions<br />
Operating temperature -25°C.....+85°C<br />
Storage temperature -40°C.....+85°C<br />
1 Octave /Minute (EN 60068-2-6)<br />
Humidity 98 % (without liquid state)<br />
Protection class (EN 60529) IP 67 (connected)<br />
Tabelle 12 Environmantal conditions<br />
Page 32 UME-AGS-CAN Version 09/04