4.10 Restore default parameters<br />
The default parameters can be restored. The<br />
already in the non-volatile memory programmed<br />
parameters are not overwritten. Only after a new<br />
CMS Index Value: Data length<br />
SDO 1011h 6C 6F 61 64 h Unsigned 32<br />
Master to Inclinometer: Set-Parameter<br />
5. Technical Data<br />
5.1. Electrical Data<br />
store command the default parameters are<br />
stored in the non-volatile memory. To restore the<br />
default parameter the following telegram is used.<br />
FC NN Command Index Subindex Service-/Processdata<br />
SDO(tx) Download 1011h Byte 4 Byte 5 Byte 6 Byte 7<br />
1100 b 1-90 d 22 11 10 01 6C 6F 61 64<br />
Model AGS 5 AGS 15 AGS 30<br />
Measuring range +/- 5° +/- 15° +/- 30°<br />
Resolution 0,001° 0,001° 0,005°<br />
Accuracy (T = 0 °C .. +55 °C) 0,06 0,18° 0,40°<br />
Accuracy (T = -25 °C . +85 °C) 0,12 0,30° 1,00°<br />
Damping period (0° -> 15°, t=90%) typ. 1,25s<br />
Interface Transceiver according ISO 11898,<br />
Transmission rate max. 1 MBaud<br />
Device addressing Via SDO<br />
galvanically isolated by opto-couplers<br />
Supply voltage 10 - 30 V DC (absolute limits)<br />
Current consumption max. 230 mA with 10 V DC, max. 100 mA with 24 V DC<br />
Power consumption max. 2,2Watts<br />
EMC<br />
Electrical lifetime > 10 5 h<br />
Tabelle 10 Electrical data<br />
Inclinometer should be connected<br />
only to subsequent electronics<br />
whose power supplies comply with<br />
EN 50178 (protective low voltage)<br />
Emitted interference: EN 61000-6-4<br />
Noise immunity: EN 61000-6-2<br />
Version 09/04 UME-AGS-CAN Page 31