05.01.2013 Views

CANOpen Manual

CANOpen Manual

CANOpen Manual

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

4.10 Restore default parameters<br />

The default parameters can be restored. The<br />

already in the non-volatile memory programmed<br />

parameters are not overwritten. Only after a new<br />

CMS Index Value: Data length<br />

SDO 1011h 6C 6F 61 64 h Unsigned 32<br />

Master to Inclinometer: Set-Parameter<br />

5. Technical Data<br />

5.1. Electrical Data<br />

store command the default parameters are<br />

stored in the non-volatile memory. To restore the<br />

default parameter the following telegram is used.<br />

FC NN Command Index Subindex Service-/Processdata<br />

SDO(tx) Download 1011h Byte 4 Byte 5 Byte 6 Byte 7<br />

1100 b 1-90 d 22 11 10 01 6C 6F 61 64<br />

Model AGS 5 AGS 15 AGS 30<br />

Measuring range +/- 5° +/- 15° +/- 30°<br />

Resolution 0,001° 0,001° 0,005°<br />

Accuracy (T = 0 °C .. +55 °C) 0,06 0,18° 0,40°<br />

Accuracy (T = -25 °C . +85 °C) 0,12 0,30° 1,00°<br />

Damping period (0° -> 15°, t=90%) typ. 1,25s<br />

Interface Transceiver according ISO 11898,<br />

Transmission rate max. 1 MBaud<br />

Device addressing Via SDO<br />

galvanically isolated by opto-couplers<br />

Supply voltage 10 - 30 V DC (absolute limits)<br />

Current consumption max. 230 mA with 10 V DC, max. 100 mA with 24 V DC<br />

Power consumption max. 2,2Watts<br />

EMC<br />

Electrical lifetime > 10 5 h<br />

Tabelle 10 Electrical data<br />

Inclinometer should be connected<br />

only to subsequent electronics<br />

whose power supplies comply with<br />

EN 50178 (protective low voltage)<br />

Emitted interference: EN 61000-6-4<br />

Noise immunity: EN 61000-6-2<br />

Version 09/04 UME-AGS-CAN Page 31

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!