Trident*<br />

7.4mm diameter<br />

The Trident Resection Ablator combines the mechanical resection capability of a<br />

standard 4.2mm Gator shaver blade with the ablation and coagulation action of an<br />

electrosurgical ablator electrode. Can be used with C7312 or C7313 cannulas.<br />

The shaver blade resection action is powered by the Linvatec Advantage ® console<br />

and shaver handpiece, while the ablation and coagulation features are activated, via<br />

the footswitch of a variety of different electrosurgical generators currently available<br />

on the market.<br />

Cat. No.<br />

Alpha 90º angle, 13cm long........................................................................ ES-9263A<br />

Delta 90º angle, 13cm long......................................................................... ES-9247A<br />

Omega 90º angle, 13cm long ..................................................................... ES-9298A<br />

U.S. Patent 5,364,395<br />

*Developed in cooperation with Hugh West, M.D., Salt Lake City, UT.<br />

LightWave, LightWave Foot Control and LightWave<br />

Suction Ablators<br />

The LightWave design incorporates a one-piece molded handle, which is plugged<br />

directly into the monopolar port of a standard electrosurgical generator. The<br />

LightWave Foot Control utilizes a generator adapter to connect to the monopolar<br />

“foot control” port of the generator. The LightWave Suction Ablator features hand<br />

controls, adjustable roller clamp suction control and universal suction tubing adapter.<br />

3.2 mm dia. x 150 mm length, 90 angle ....................................................... IA-2379<br />

3.2 mm dia. x 150 mm length, 90 angle.................................................. IA-2379-FC<br />

4.5 mm dia. x 142 mm length, multi-angle ................................................ IA-2000-S<br />

Trident ® Resection Ablators<br />

and LightWave Ablators<br />

Alpha<br />

(Gator)<br />

Delta<br />

(Full Radius)<br />

Omega<br />

(Mako)<br />

Ablation<br />

Opposite side<br />

of cutting<br />

window<br />

Customer Service: (within U.S.) Phone: 800.237.0169 • Fax 727.399.5256 • Customer Service: (outside U.S.) Phone: 727.392.6464 • Fax: 727.397.4540 <strong>ESA</strong> <strong>ELECTROSURGICAL</strong> <strong>ARTHROSCOPY</strong> PRODUCTS, F.7