e served in the same manner<br />

as a "stick-built" (on-site) home (per<br />

NEC Article 230).<br />

408. MOBILE<br />

HOMES AND MANUFACTURED HOMES<br />

A. MOBILE HOMES<br />

A mobile home [factory-assembled structure or structures,<br />

transportable<br />

in one or more sections, that is built on a<br />

perma nent chassis (heavy I-beams) and designed to be used as a<br />

dwelling without a permanent<br />

foundation] shall have the service<br />

equipment<br />

mounted separate from the structure in accordance<br />

with NEC<br />

Section 550.32 (A) and Illustration No.s 4, 5 or No. 9<br />

in Section<br />

XII of this handbook. Note, the term "mobile home"<br />

(for purposes of this handbook) refers to a structure built prior<br />

to<br />

June 15, 1976. <strong>Company</strong> approved prewired combination meter<br />

and service equipment may be used (See the “Supplement”<br />

located<br />

in the inside back cover of this handbook).<br />

The<br />

<strong>Company</strong> is not responsible for enforcement of<br />

the<br />

rules, e.g. NEC, beyond the service disconnecting<br />

means/overcurrent protection and service grounding; therefore, the<br />

<strong>Company</strong><br />

will not be determining whether or not<br />

an additional<br />

disconnect is required (within 30 feet of the<br />

unit) as a condition<br />

for activation of the electric service. As with any service,<br />

however, the <strong>Company</strong> reserves the right to refuse connection<br />

when doing so would create a dangerous or unsafe condition.<br />

G rounding at the disconnecting means shall be in accordance<br />

with<br />

NEC Section 250.32. The service cable installation (on the line<br />

side of the service disconnecting means) must meet all <strong>Company</strong><br />

standards for underground service, as applicable.<br />

In accordance with NEC Article 550, the service equipment<br />

shall be rated at not less than 100 amperes, and provisions shall<br />

be<br />

made for connecting a mobile home "feeder assembly" (4<br />

insulated conductors) by a permanent wiring method. <strong>Power</strong><br />