DONATI SOLLEVAMENTI S.r.l. - Via Roma, 55 - 21020 Daverio (VA) - Tel. 0332 942611 - Fax. 0332 948597<br />

Quarterly check of the efficiency of the brake of the rotation arm of the crane:<br />

• Check the stability of the arms when empty and when fully loaded, at the end points and<br />

intermediate points of rotation; then checking that the arms, in any point of the rotation, keeps its<br />

position with moving spontaneously.<br />

• When necessary have the brake of the crane adjusted, as described in paragraph 6.4.1 “Adjustment<br />

of the rotation brake of the crane arm”, on page 55.<br />

• Replace the clutch plates of the brake when there is instability of the arm<br />

after adjusting the brake.<br />

IN CASE OF <strong>AN</strong>OMALIES:<br />

• It is forbidden to carry out corrective maintenance work on the brake of the<br />

rotation arm of the jib crane.<br />

• Any operation, outside normal maintenance, on the brake of the rotation<br />

arm of the crane can be done by the assistance service of DONATI<br />

SOLLEVAMENTI S.r.l. or by staff authorized by them.<br />

Quarterly check of the efficiency of the electric power supply:<br />

53<br />

TECNICO<br />

DONATI<br />

DONATI<br />

SERVICE<br />

• Check the efficiency of the power cable, check there is no peeling, cuts , lacerations or other<br />

changes in the protection sheath.<br />

• Check the seal of the protectors, the power cable, their clamps (in the connector block) and,<br />

if necessary, tighten them correctly.<br />

• Check the efficiency of the conductors and the grounding connections, carrying out a check,<br />

and, if necessary, fixing all the grounding screws.<br />

• Carry out a check of all the weather strips of the covers and the cable clamps.<br />

• Check there are warning plates and that they are visible.<br />

• Do non hesitate to replace the electrical component, if it is no<br />

longer giving sufficient guarantee of functional reliability<br />

• Never carry out improvised repairs<br />

• Use original spare parts<br />

For information about checks of all the structural, mechanical and electromechanical<br />

components of the lifting units of the jib crane, see the relevant documentation<br />

included in this technical publication<br />

.<br />

• Don’t hesitate to replace the part and /or the component in question, when it no<br />

longer gives sufficient guarantee of safety and/or functional reliability.<br />

• Never carry out improvised repairs!