03.01.2013 Views

C Thermo

C Thermo

C Thermo

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

5<br />

5<br />

4<br />

4<br />

3<br />

D D<br />

SCAN+<br />

SCAN-<br />

SCAN_STRB<br />

C C<br />

/SCAN_LED_ON<br />

D<br />

R27<br />

1K<br />

R26<br />

1K<br />

+5V<br />

+5V<br />

R25<br />

301<br />

R24<br />

1K<br />

+5V<br />

FPGA on Source PCB provides /SCAN LED ON<br />

signal when firmware toggles SCAN ON function.<br />

R28<br />

1K<br />

+5V<br />

+5V<br />

TP2<br />

1<br />

TP3<br />

1<br />

+5V<br />

B B<br />

C1<br />

.1uF<br />

U1A<br />

2<br />

IN+<br />

1<br />

IN-<br />

4<br />

CON<br />

12<br />

CON<br />

DS26C32ATN<br />

C2<br />

.1uF<br />

OUT<br />

3<br />

D<br />

SCAN_STRB<br />

COUNTER is advanced at the beginning of each<br />

SCAN event.<br />

U2<br />

14<br />

CLK Q0<br />

3<br />

Q1<br />

2<br />

13<br />

CKE Q2<br />

4<br />

15<br />

RST Q3<br />

7<br />

Q4<br />

10<br />

Q5<br />

1<br />

Q6<br />

5<br />

Q7<br />

6<br />

Q8<br />

9<br />

16<br />

VDD Q9<br />

11<br />

COUT<br />

CD4017BE<br />

12<br />

LED's illuminate in sequence, with previous LED<br />

Extinguishing as the next is Driven.<br />

A A<br />

3<br />

2<br />

2<br />

2<br />

2<br />

2<br />

3<br />

1<br />

3<br />

1<br />

3<br />

1<br />

3<br />

1<br />

3<br />

1<br />

Q2<br />

2N3904<br />

Q3<br />

2N3904<br />

Q4<br />

2N3904<br />

Q1<br />

2N3904<br />

Q5<br />

2N3904<br />

R20<br />

31.6<br />

R21<br />

31.6<br />

R22<br />

31.6<br />

R19<br />

31.6<br />

R23<br />

31.6<br />

D15<br />

BLUE<br />

D18<br />

BLUE<br />

D25<br />

BLUE<br />

DRN<br />

CHK<br />

DSN<br />

ENGR<br />

MFG<br />

2<br />

D21<br />

BLUE<br />

D22<br />

BLUE<br />

2<br />

D14<br />

BLUE<br />

D17<br />

BLUE<br />

BY<br />

D20<br />

BLUE<br />

D23<br />

BLUE<br />

D26<br />

BLUE<br />

Steve Fenske<br />

<br />

Steven Fenske<br />

<br />

<br />

Thursday, March 20, 2003<br />

D13<br />

BLUE<br />

D16<br />

BLUE<br />

D19<br />

BLUE<br />

D24<br />

BLUE<br />

D27<br />

BLUE<br />

DATE<br />

03-20-03<br />

<br />

03-20-03<br />

<br />

<br />

Size<br />

Scale<br />

D<br />

<strong>Thermo</strong>Finnigan<br />

SAN JOSE CA 95134-1991<br />

<br />

<br />

Schematic, Front Panel Display<br />

C<br />

*<br />

*<br />

*<br />

*<br />

CAGE Code DWG NO Rev<br />

<br />

3<br />

97055-91110<br />

1<br />

THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF THERMO FINNIGAN CORPORATION AND IS TENDERED<br />

SUBJECT TO THE CONDITION THAT THE INFORMATION (A) BE RETAINED IN CONFIDENCE (B) NOT BE REPRODUCED<br />

OR COPIED IN WHOLE OR IN PART AND (C) NOT BE USED OR INCORPORATED IN ANY PRODUCT, EXCEPT UNDER AN EXPRESS<br />

WRITTEN AGREEMENT WITH THERMO FINNIGAN<br />

Rev ECO NO. Date: BY CHK<br />

3 01-24-03 Steven F. Mark S.<br />

1<br />

Sheet<br />

1 of 1

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!