The benefits at a glance<br />

<strong>–</strong>Released <strong>for</strong> <strong>and</strong> coordinated<br />

with <strong>SOFTNET</strong>-S7 <strong>and</strong><br />

<strong>SOFTNET</strong>-PG <strong>for</strong> <strong>Industrial</strong><br />

<strong>Ethernet</strong><br />

<strong>–</strong> Designed <strong>for</strong> use in <strong>industrial</strong><br />

environments<br />

<strong>–</strong> Integrated into the Hardware<br />

Configuration of the STEP 7<br />

<strong>and</strong> NCM PC configuring tools<br />

<strong>–</strong>Driver software will be<br />

integrated into the Microsoft<br />

operating systems in future<br />

<strong>–</strong>Adjustable MAC address<br />

<strong>–</strong> Can be used <strong>for</strong> office <strong>and</strong><br />

automation networks<br />

<strong>–</strong> Siemens Support (Hotline)<br />

simatic net<br />

SIMATIC NET CP 1512/ CP 1612


CP 1512 communications processors<br />

<strong>for</strong> PGs (programming devices) <strong>and</strong><br />

<strong>notebooks</strong><br />

with PCMCIA slot (32-bit CardBus interface)<br />

<strong>for</strong> connecting to <strong>Industrial</strong> <strong>Ethernet</strong> at<br />

10/100 Mbit/s.<br />

The CP 1512 is an <strong>Ethernet</strong> card that can<br />

be used in conjunction with all <strong>SOFTNET</strong>®<br />

packages <strong>for</strong> <strong>Industrial</strong> <strong>Ethernet</strong> (except<br />

UNIX) in, <strong>for</strong> example, a notebook <strong>for</strong><br />

remote programming <strong>and</strong> diagnostics<br />

(PG/OPcommunications).<br />

CP 1612 communications processors<br />

<strong>for</strong> <strong>industrial</strong> PCs<br />

with PCI slot <strong>for</strong> connecting to <strong>Industrial</strong><br />

<strong>Ethernet</strong> at 10/100 Mbit/s.<br />

The CP 1612 is an <strong>Ethernet</strong> card that can<br />

be operated with all <strong>SOFTNET</strong> packages<br />

<strong>for</strong> <strong>Industrial</strong> <strong>Ethernet</strong> (except UNIX).<br />

Technical data:<br />

Communications processors<br />

Data transfer rate<br />

Interfaces<br />

Connection to<br />

<strong>–</strong> <strong>Industrial</strong> <strong>Ethernet</strong><br />

<strong>–</strong> PG/PC<br />

Supply voltage<br />

Current consumption<br />

Permissible environmental conditions<br />

<strong>–</strong> Operating temperature<br />

<strong>–</strong> Non-operating temperature<br />

<strong>–</strong> Relative humidity<br />

Design of the CP<br />

<strong>–</strong> Module <strong>for</strong>mat<br />

<strong>–</strong> Dimensions (W x H x D)<br />

<strong>–</strong> Weight<br />

<strong>–</strong> Space requirements<br />

Software/Drivers<br />

*) Thanks to the built-in auto negotiation function, the system automatically detects whether an <strong>Ethernet</strong> line with a b<strong>and</strong>width of 10 Mbit/s or 100 Mbit/s <strong>and</strong><br />

half-duplex/full-duplex mode is is connected, <strong>and</strong> the interface adjusts to this.<br />

The technical data only refer to the specification of the products. Characteristics are not warranted.<br />

Siemens AG<br />

Automation <strong>and</strong> Drives<br />

P.O. Box 48 48<br />

D-90327 Nuremberg<br />

www.siemens.de/simatic-net<br />

Configuring the CP 1512 <strong>and</strong> CP 1612<br />

The S7 Communication <strong>and</strong> S5-compatible<br />

Communication protocols are configured<br />

in STEP 7/NCM PC. The configuring tools<br />

Step7 from V5.1 Sp3 or NCM PC from<br />

V5.1 SP2 are included in the scope of supply<br />

of the <strong>SOFTNET</strong>-S7 <strong>and</strong> <strong>SOFTNET</strong>-PG<br />

software packages <strong>for</strong> <strong>Industrial</strong> <strong>Ethernet</strong>.<br />

NCM PC is a component part of Advanced<br />

PC Configuration.<br />

F O U N D A T I O N<br />

M E M B E R<br />

Advanced PC Configuration at http:<br />

//www.siemens.de/simatic-net/ik-info<br />

CP 1512 <strong>and</strong> CP 1612 <strong>for</strong> integrated<br />

communications<br />

The CP 1512 <strong>and</strong> CP 1612 offer the follow-<br />

CP 1512<br />

10/100 Mbit/s auto negotiation*)<br />

RJ45 via adapter<br />

PCMCIA Slot Type II or Type III<br />

(32-bit CardBus)<br />

DC 3,3 V ±5 %<br />

180 mA<br />

0 °C to +60 °C<br />

<strong>–</strong> 20 °C to +70 °C<br />

90 % at +25 °C<br />

PCMCIA Type II<br />

85.6 x 54 x 5 mm<br />

40 g<br />

1x PCMCIA slot Type II<br />

Windows98, NT(Cardwizard<br />

from Systemsoft from Version V5.2<br />

required), 2000, ME<br />

Subject to change without prior notice. Printed in Germany<br />

Order No. E20001-A60-P820-V1-7600<br />

41C7536 SB 04023.5<br />

ing access options: Level 2 (interface <strong>for</strong><br />

PC networks in the <strong>industrial</strong> environment),<br />

Level 4 <strong>and</strong> Level 7.<br />

Support is provided <strong>for</strong> communications<br />

services using ISO or TCP/IP transport<br />

protocols, PG/OP Communication,<br />

S7 Communication, S5-compatible<br />

Communication (SEND/RECEIVE), <strong>and</strong><br />

using the protocols <strong>for</strong> <strong>Industrial</strong> <strong>Ethernet</strong><br />

provided by the operating system.<br />

CP 1512 <strong>and</strong> CP 1612 fast installation<br />

in accordance with the plug & play<br />

mechanism of the operating system<br />

CP 1512 <strong>and</strong> CP 1612 from SIMATIC NET<br />

designed <strong>for</strong> industry<br />

Like all SIMATIC NET products from<br />

Siemens, the communications processors<br />

are consistently designed <strong>for</strong> use in<br />

dem<strong>and</strong>ing <strong>industrial</strong> environments.<br />

CP 1612<br />

10/100 Mbit/s auto negotiation*)<br />

RJ45<br />

PCI (32 bit)<br />

5 V DC ±5 %, 12 V<br />

200 mA<br />

0 °C to +50 °C<br />

<strong>–</strong> 25 °C to +55 °C<br />

95 % at +25 °C<br />

Short PCI <strong>for</strong>mat<br />

Approx. 50 x 120 mm<br />

Approx. 100 g<br />

1x PCI slot<br />

Windows98, NT, 2000, ME