Error messages<br />
%OMNIHOME%\bin\nco_g_snmp.exe<br />
To start the gateway as a service on Windows operating systems, use the following<br />
steps:<br />
1. Register the gateway with the Service Control Manager.<br />
2. If the gateway and the ObjectServer are running on the same host, run the<br />
following command:<br />
%OMNIHOME%\bin\nco_g_snmp.exe -install -depend NCOObjectServer<br />
3. If the gateway and the ObjectServer are running on different hosts, run the<br />
following command:<br />
%OMNIHOME%\bin\nco_g_snmp.exe -install<br />
4. Start the gateway using the Microsoft Services Management Console.<br />
Error messages provide information about problems that have occurred during the<br />
operation of the gateway. You can use the information that they contain to resolve<br />
such problems.<br />
The following table describes the error messages that the gateway generates:<br />
Table 13. Error messages<br />
Error Description Action<br />
Failed to send trap for The gateway failed to Verify that the endpoint is<br />
<strong>SNMP</strong> trap forwarder with forward a trap for the reason available and reachable.<br />
error error. Retrying... specified in the error Check for any intervening<br />
message. It is trying to<br />
re-send the trap.<br />
firewalls.<br />
Failed to create session The gateway was unable to Verify that the endpoint is<br />
for <strong>SNMP</strong> trap forwarder. reconnect to the endpoint still available and that there<br />
after a previous<br />
disconnection.<br />
is no intervening firewall.<br />
Failed to initialize The gateway could not Verify that the properties file<br />
gateway properties. initialize the gateway has correct permissions.<br />
properties.<br />
Check the values set in the<br />
properties file.<br />
Invalid value specified The transport protocol field Specify the value of the<br />
for PROTOCOL attribute. is incorrectly specified and Gate.<strong>SNMP</strong>.Protocol property<br />
Ignored and using UDP. the gateway is defaulting to<br />
the UDP protocol.<br />
as either UDP or TCP.<br />
Node index not found for The gateway was unable to Verify that there is a ’Node’<br />
<strong>SNMP</strong> trap forwarder find a column entitled 'Node' = ’@’ entry in<br />
in the configured table. the mapping file that you are<br />
using.<br />
oid property has an The Gate.<strong>SNMP</strong>.OID property Ensure that the<br />
invalid value; must be a must be specified as an Gate.<strong>SNMP</strong>.OID property is<br />
string or a field<br />
object identifier (OID) string specified as an OID string or<br />
reference.<br />
or a reference to the node<br />
group field.<br />
as @NodeGroup.<br />
Snmpversion property has The <strong>SNMP</strong> writer version is Specify the value of the<br />
unknown <strong>SNMP</strong> version incorrectly specified. Gate.<strong>SNMP</strong>.<strong>SNMP</strong>Version<br />
specified in <strong>SNMP</strong> trap<br />
forwarder. Please set it<br />
to12or3<br />
property as either 1, 2, or3.<br />