Table 6. Generic gateway properties (continued)<br />

Property name Command line option Description<br />

Gate.Reader.Debug boolean -readerdebug boolean Use this property to specify<br />

whether the gateway<br />

includes gateway reader<br />

debug messages in the debug<br />

log.<br />

Gate.Reader.Description<br />

string<br />

Gate.Reader.Details<br />

TableName string<br />

Gate.Reader.<br />

FailbackEnabled boolean<br />

Gate.Reader.<br />

FailbackTimeout integer<br />

The default is TRUE.<br />

-readerdescription string Use this property to specify<br />

the application description<br />

for the reader connection.<br />

This description is used in<br />

triggers and allows you to<br />

determine which component<br />

of the gateway attempted to<br />

perform an action.<br />

-readerdetailstblname<br />

string<br />

The default is <strong>Gateway</strong><br />

Reader.<br />

Use this property to specify<br />

the name of the details table<br />

that the gateway reads.<br />

The default is<br />

alerts.details.<br />

-failbackenabled boolean Use this property to specify<br />

whether or not the gateway<br />

attempts to fail back to the<br />

primary system following a<br />

system failover.<br />

The default is TRUE.<br />

Note: The gateway attempts<br />

to fail back with the<br />

frequency specified by the<br />

Gate.Reader.<br />

FailbackTimeout property.<br />

-failbacktimeout integer Use this property to specify<br />

the frequency (in seconds)<br />

with which the gateway<br />

attempts to fail back to the<br />

primary system following a<br />

system failover.<br />

The default is 30.<br />

Note: The gateway attempts<br />

to fail back to the primary<br />

ObjectServer only if the<br />

Gate.Reader.<br />

FailbackEnabled property is<br />

set to TRUE.<br />

<strong>IBM</strong> <strong>Tivoli</strong> <strong>Netcool</strong>/<strong>OMNIbus</strong> <strong>SNMP</strong> <strong>Writer</strong> <strong>Gateway</strong> 9