2-7. Disc Check Memory<br />
Disc Check Memory<br />
1. SL Disc check<br />
2. SL Disc check<br />
3. SL Disc check<br />
Exit: RETURN<br />
On this screen, measure the mirror time of chucked disc, and write<br />
to the EEPROM.<br />
2-8. Error Rate Display<br />
Error Rate Display<br />
UC CR ADD<br />
PI1 Err Now xx xxxx xxxxxxxx<br />
Max xx xxxx xxxxxxxx<br />
Avg xx xxxx xxxxxxxx<br />
PI2 Err Now xx xxxx xxxxxxxx<br />
Max xx xxxx xxxxxxxx<br />
Avg xx xxxx xxxxxxxx<br />
PO Err Now xx xxxx xxxxxxxx<br />
Max xx xxxx xxxxxxxx<br />
Avg xx xxxx xxxxxxxx<br />
Exit: RETURN<br />
On this screen, measure and display the error rate.<br />
UC : Incorrect value<br />
CR : Correct value<br />
Add : Address<br />
2-9. SACD Water Mark Check<br />
SACD Water Mark Check<br />
PSP AMP<br />
PSN<br />
Start: ENTER Exit: RETURN<br />
On this screen, measure the PSP AMP value and PSN value of SACD<br />
water mark.<br />
HCD-S550/S880<br />
3. MECHA AGING<br />
On the Test Mode Menu screen, selecting [3] executes the aging of<br />
the mechanism deck.<br />
### Aging Test MENU ###<br />
Operation Menu<br />
1. Open/Close Test<br />
Exit: RETURN<br />
1) On the Aging Test MENU screen, press the [1] key on the<br />
remote commander to display the Open/Close Test screen.<br />
2) Insert discs and press the [ENTER] key on the remote<br />
commander.<br />
3) Is starts the aging.<br />
During aging, the disc number, operating status and repeat cycle<br />
are displayed. Aging can be aborted at any time by pressing<br />
the x key. After the operation is stopped, press the x key or<br />
[RETURN] key aging to return to the Aging Test MENU.<br />
4. EMERGENCY HISTORY<br />
On the Test Mode Menu screen, selecting [4] displays the<br />
information such as servo emergency history.<br />
The history information from last 1 up to 10 can be scrolled with<br />
the O key or o key. Also, specific information can be displayed<br />
by directly entering that number with ten keys.<br />
### EMG. History ###<br />
Laser Hours CD xxxxhxxm<br />
DVD xxxxhxxm<br />
a. bb xx xx xx xx xx xx xx<br />
xx xx xx xx xx xx xx xx<br />
a. bb xx xx xx xx xx xx xx<br />
xx xx xx xx xx xx xx xx<br />
Select:1-9 Scroll:UP/DOWN<br />
(1.Latest EMG.) Exit: RETURN<br />
xxxxhxxm : The laser on total hours. Data below minutes are<br />
omitted.<br />
a. : Error number.<br />
bb : Error code.<br />
xx : Not used.<br />
• Clearing History Information<br />
Clearing laser hours:<br />
Press the [DVD DISPLAY] and [CLEAR] keys in this order.<br />
Then both CD and DVD data are cleared.<br />
Clearing emergency history:<br />
Press the [DVD TOP MENU] and [CLEAR] keys in this order.<br />
Initializing set up data:<br />
Press [DVD MENU] and [CLEAR] keys in this order.<br />
The data have been initialized when “Set Up Initialized”<br />
message is displayed. The EMG. History screen will be restored<br />
soon.<br />
25