britec - Surge Protection Device
britec - Surge Protection Device britec - Surge Protection Device
BRITEC BRM6 MCCB
- Page 2 and 3: 1 Application Type and its meaning
- Page 4 and 5: Wiring Frame rated current 63A 125A
- Page 6 and 7: 5 Main technical parameters 5 Inm I
- Page 8 and 9: Protection characteristic 1.Variabl
- Page 10 and 11: 6.3Microprocessor Control Panel Loa
- Page 12 and 13: Protection performance of residual
- Page 14 and 15: Overall and installation dimension
- Page 16 and 17: Installation Dimension Plug-in vers
- Page 18 and 19: Installation dimension Draw-out ver
- Page 20 and 21: 8 Motor Operator 8.1 Motor operator
- Page 22 and 23: 8.2 Rotary handle operation Mechani
- Page 24 and 25: 9 Accessory Left side of breaker In
- Page 26: 9.3 Auxiliary contact & warning con
BRITEC<br />
BRM6 MCCB
1<br />
Application<br />
Type and its meaning<br />
1<br />
BRM6 Moulded Case Circuit Breaker<br />
As one of the Britec most important products, BRM6 moulded case low-voltage circuit breakers offer good<br />
performance that meets the full spectrum of application requirements, from small users to large industrial electricity<br />
distribution installations. It is high quality, reliability, and performance under all conditions, simple for installation<br />
and safety of operation.<br />
Innovation, technology and quality have always been the principles of guiding the development of BRM6.The<br />
continual and constant evolution of the BRM6 has led to further extending the range of products.<br />
Special technical solutions, such as two fixed contacts for each arcing chamber, offers excellent performance in<br />
terms of breaking, fault current limiting and specific let-through current capacity.<br />
BRM6 has variety applications in industrial and civil sectors. It can be used for motor protection, switchdisconnecting,<br />
circuit-breaking, and residual current circuit breaking, as well as specific ranges (for motor protection<br />
and switch-disconnecting) complying with the standard of IEC60947-1, IEC60947-2, IEC60947-4-1.<br />
This means wider application possibilities both in industrial and civil sectors. They can therefore be mounted in<br />
primary Power Center and secondary Panel Board distribution switchboards, for motor protection and control<br />
Motor Control Center, in generators and for end users. Their performances are, however, of particular interest where<br />
critical situations arise (very high rated and fault currents), or where complex plant engineering solutions are needed<br />
(special coordination requirements and plant automation). They also guarantee total selectivity of the protections up<br />
to full breaking capacity of the circuit-breaker installed on the load side.<br />
2<br />
●<strong>Protection</strong><br />
and control in installations for circuit protection<br />
●Particularly<br />
severe environmental conditions such as mines and steelworks<br />
●Refineries<br />
and chemical plants as well as gas pipelines, water pipelines.<br />
●Installation<br />
on-board ships<br />
●Offices,<br />
theaters, shopping malls and residential complexes<br />
●Underground<br />
railway stations<br />
●Off-shore<br />
drilling rigs<br />
BR M 6<br />
Usage code*<br />
Release and accessory code (table 2)<br />
Number of poles: 3for 3 poles ; 4 for 4 poles;<br />
4A: N pole always connected<br />
4B: N poles without protection, 4C: N pole with protection<br />
Operation mode code**<br />
Rated current In<br />
Rated current of frame Inm<br />
Rated limit short-circuit breaking capacity<br />
code (table 1)<br />
Design code<br />
Moulded case circuit breaker<br />
Note: * No code for circuit protection breaker , 2 for motor protection breaker.<br />
** No code for direct handle operation, 2 for handle operation, D for motor operation.<br />
1
3<br />
Breaker's Main Technical Parameters<br />
Complete current range<br />
16A<br />
20A<br />
25A<br />
32A<br />
High-breaking capacity<br />
40A<br />
50A<br />
(1) B: Basic breaking capacity type<br />
63A<br />
(2) N: Normal breaking capacity type<br />
(3) S: Standard breaking capacity type<br />
Frame Rated current<br />
63A<br />
125A<br />
160A<br />
250A<br />
400A<br />
630A<br />
800A<br />
1250A<br />
1600A<br />
100A<br />
80A<br />
160A<br />
125A<br />
2<br />
630A<br />
400A<br />
350A<br />
315A<br />
250A<br />
225A<br />
200A<br />
180A<br />
1600A<br />
1250A<br />
1000A<br />
800A<br />
700A<br />
20kA 35kA 50kA 65kA 85kA 100kA<br />
B<br />
B<br />
B<br />
N<br />
N<br />
N<br />
N<br />
N<br />
N<br />
N<br />
(4) H: High-breaking capacity type<br />
(5) G: The highest breaking capacity type<br />
(6) X : Current limit type<br />
Rated ultimate short circuit breaking capacity class<br />
Rated ultimate short circuit breaking capacity Icu<br />
S<br />
S<br />
S<br />
S<br />
S<br />
S<br />
S<br />
H<br />
H<br />
H<br />
H<br />
H<br />
H<br />
S H<br />
G<br />
G<br />
X<br />
X<br />
X<br />
Table 1
Wiring<br />
Frame<br />
rated current<br />
63A<br />
125A<br />
160A<br />
250A<br />
630A<br />
800A<br />
1250A<br />
1600A<br />
Operation Syle<br />
63A<br />
125A<br />
160A<br />
250A<br />
400A<br />
630A<br />
800A<br />
1250A<br />
1600A<br />
Front<br />
Frame rated current<br />
Microprocer controlled<br />
Fixed type<br />
Rear<br />
rotary Horizontal Vertical<br />
Direct handle operation<br />
(Code:no)<br />
Wiring and installation class<br />
Wiring and installation class<br />
Lengthen<br />
front<br />
3<br />
Plug-in type Withdrawable type<br />
Front<br />
Rear<br />
rotary Front<br />
Electromotor operation<br />
(Code:D)<br />
Table 3<br />
BRM6 series circuit breaker (Inm≧250A) adopt advanced microprocessor electronic release that<br />
can intelligentize the protection of the circuit.<br />
Convenient installation<br />
BRM6 series circuit breaker provide several installation types.<br />
rotary<br />
Rear<br />
Horizontal<br />
Fixed installation Plug-in installation Draw-out installation<br />
Vertical<br />
Table 2
4<br />
Connection type of circuit breaker<br />
Front connection<br />
Rear connection<br />
4<br />
Rear rotary connection<br />
Extended front connection Horizontal rear connection<br />
Normal working environment<br />
Ambient air temperature : -5 ℃~ +40℃<br />
Gradient : ≦22.5<br />
Resistance to salt spray and oil spray<br />
Altitude : ≦2000m<br />
Ambient environment/medium free from explosive danger, air or conductive dust which may<br />
cause corrosion of metal or influence the stability of installation<br />
Please free from erosion of rain and snow
5<br />
Main technical parameters<br />
5<br />
Inm<br />
In<br />
Icu AC 400V/50Hz O-CO kA<br />
Ics AC 400V/50Hz O-CO-CO kA<br />
Icw AC400V/50HZ<br />
L<br />
W H<br />
BRM6<br />
Moulded case circuit breaker<br />
Class of breaking capacity<br />
Frame rated current<br />
Rated current<br />
Rated insulating voltage<br />
Rated operating voltage<br />
Number of poles<br />
N-pole rated current<br />
Rated ultimate short-circuit breaking capacity<br />
Rated operating short-circuit breaking capacity<br />
Rated short-time withstand current for 1s<br />
Rated impulse withstand voltage<br />
Life<br />
Flashover distance<br />
Release<br />
W (mm)<br />
L (mm)<br />
H (mm)<br />
Total times<br />
Electrical life<br />
Mechanical life<br />
Ui<br />
Ue<br />
kA<br />
Uimp V<br />
Thermal magnetic release<br />
Electronic release<br />
Main circuit<br />
Usage category Accessorial circuit<br />
& control circuit<br />
Dimensions<br />
Weight<br />
Fixed<br />
Plug in<br />
Withdrawable<br />
3P<br />
4P<br />
3P<br />
4P<br />
3P<br />
4P<br />
3P/4P<br />
3P/4P<br />
3P/4P<br />
mm<br />
B N S<br />
125<br />
12.5 16 20 25 32 40 50<br />
63 80 100 125<br />
400V<br />
400V<br />
3/4<br />
=In<br />
20 35<br />
10 17.5<br />
76<br />
101<br />
120<br />
120<br />
70<br />
6000<br />
10000<br />
1500<br />
8500<br />
≤30<br />
A<br />
AC-15<br />
76<br />
101<br />
120<br />
120<br />
70<br />
70<br />
70<br />
0.92/1.3<br />
1.2/1.5<br />
B N<br />
160<br />
16 20 2532 40 50<br />
63 80 100 125 160<br />
690V<br />
400V<br />
3/4<br />
=In<br />
20 35 50<br />
10 17.5 25<br />
90<br />
120<br />
120<br />
120<br />
70<br />
70<br />
8000<br />
8000<br />
1000<br />
7000<br />
≤30<br />
A<br />
AC-15<br />
90<br />
120<br />
120<br />
120<br />
70<br />
70<br />
1.2/1.6<br />
1.4/1.8<br />
S<br />
90<br />
120<br />
120<br />
120<br />
79<br />
79
N S H X<br />
250<br />
125 160 (180) 200 (225) 250<br />
690V<br />
400V<br />
3/4<br />
=In<br />
35 50 65<br />
35 37.5 48.8<br />
105<br />
140<br />
170<br />
170<br />
103.5<br />
103.5<br />
2.7/3.5<br />
3.2/4.2<br />
3.6/4.6<br />
8000<br />
8000<br />
1000<br />
7000<br />
≤50<br />
A<br />
AC-15<br />
100<br />
75<br />
105<br />
140<br />
254<br />
254<br />
103.5<br />
103.5<br />
5<br />
8.2<br />
9<br />
N S<br />
630(400)<br />
250 315 (350) 400<br />
690V<br />
400V<br />
3/4<br />
=In<br />
35 50 65<br />
35 37.5 48.8<br />
5<br />
8000<br />
5000<br />
1000<br />
4000<br />
≤50<br />
A,B<br />
AC-15<br />
140<br />
184<br />
254<br />
254<br />
103.5<br />
103.5<br />
5.1/7<br />
6.2/8.5<br />
6.5/8.7<br />
H<br />
6<br />
N S H X<br />
400 500 630 (700) 800<br />
690V<br />
400V<br />
3/4<br />
=In<br />
35 50 65<br />
35 37.5 48.8<br />
210<br />
280<br />
268<br />
268<br />
103.5<br />
103.5<br />
800(630)<br />
8000<br />
5000<br />
1000<br />
4000<br />
≤80<br />
A,B<br />
AC-15<br />
9.6/12.2<br />
12.2/15.3<br />
100<br />
75<br />
S H G<br />
800 1000 1250 1600<br />
690V<br />
400V<br />
3/4<br />
=In<br />
50 65<br />
50 48.75<br />
10 20<br />
-<br />
210<br />
280<br />
406<br />
406<br />
103.5<br />
103.5<br />
1600(1250)<br />
8000<br />
3000<br />
500<br />
2500<br />
≤80<br />
B<br />
AC-15<br />
210<br />
280<br />
406<br />
406<br />
138.5<br />
138.5<br />
17.2/22.2<br />
-<br />
22/30.1<br />
Table 4<br />
100<br />
50
<strong>Protection</strong> characteristic<br />
1.Variable parameters of thermal overload protection current setting<br />
2.Characteristics of Thermal magnetic Over-current release<br />
3.Characteristics of inverse time delay thermal releaseping-<br />
Ranges of current settings of thermal inverse time delay<br />
Fram<br />
rated<br />
current<br />
size<br />
Im(A)<br />
Circumstance temperature<br />
+10° C +20° C +30° C +40° C +50° C+60°<br />
C<br />
Rated current<br />
Current settings<br />
of inverse time delay Adjustable<br />
40° C<br />
A/B/C Phase<br />
Setting lrl<br />
Instantaneous Current<br />
(A)<br />
N Pole 5In 7.5In 10In<br />
Instantaneous<br />
releaseping<br />
Current<br />
12.5A 12.5A 12.5A - - - 500A<br />
16A 16A<br />
16A - - - 500A<br />
20A 20A<br />
20A - - - 500A<br />
25A 25A<br />
25A - - - 500A<br />
125 1.19 1.03 1.06 1.0In 0.93 0.87<br />
32A<br />
40A<br />
32A<br />
40A<br />
32A<br />
40A<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
500A<br />
500A<br />
50A 50A<br />
50A - - - 500A<br />
63A 63A<br />
63A - - - 630A<br />
80A 80A<br />
80A - - - 800A<br />
100A 100A 100A - - - 1000A<br />
125A 125A 125A - - - 1250A<br />
32A 22.4~ 32A 22.4~ 32A - - - 500A<br />
40A 28~40A 28~40A - - - 500A<br />
50A 35~ 50A 35~ 50A - - - 500A<br />
160 1.15 1.10 1.05 1.0In 0.94 0.88<br />
63A<br />
80A<br />
44.1~ 63A<br />
56~ 80A<br />
44.1~ 63A<br />
56~ 80A<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
630A<br />
800A<br />
100A 70~ 100A 70~ 100A - - - 1000A<br />
125A 87.5~ 125A 87.5~ 125A - - - 1250A<br />
160A 112~ 160A 112~ 160A - - - 1600A<br />
125A 87.5~ 125A 87.5~ 125A - - - 1250A<br />
160A 112~ 160A 112~ 160A - - - 1600A<br />
(180A) 126~ 180A 126~ 180A - - - 1800A<br />
250 1.14 1.10 1.05 1.0In 0.95 0.87 200A 140~ 200A 140~ 200A - - - 2000A<br />
(225A) 157.5~ 225A 157.5~ 225A - - - 2250A<br />
250A 175~ 225A 175~ 225A - - - 2500A<br />
250A 175~ 250A 175~ 250A 1250 1875 2500 2500A<br />
315A 220.5~ 315A 220.5~ 315A 1575 2363 3150 3150A<br />
(400)<br />
630<br />
1.13 1.11 1.04 1.0In 0.92 0.85<br />
(350A)<br />
400A<br />
500A<br />
245~ 350A<br />
280~ 400A<br />
350~ 500A<br />
245~ 350A<br />
280~ 400A<br />
350~ 500A<br />
1750<br />
1750<br />
2500<br />
2625<br />
2625<br />
3750<br />
3500<br />
4000<br />
5000<br />
3500A<br />
4000A<br />
5000A<br />
630A 441~ 630A 441~ 630A 3150 4725 6300 6300A<br />
400A 400A 400A - - - 4000A<br />
(630)<br />
800<br />
1.10 1.08 1.03 1.0In 0.84 0.77<br />
500A<br />
630A<br />
(700A)<br />
500A<br />
630A<br />
700A<br />
500A<br />
630A<br />
700A<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
5000A<br />
6300A<br />
7000A<br />
800A 800A 800A - - - 8000A<br />
800A 800A 800A - - - -<br />
(1250)<br />
1600<br />
1.08 1.06 1.02 1.0In 0.8 0.73<br />
1000A<br />
1250A<br />
1000A<br />
1250A<br />
1000A<br />
1250A<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
1600A 1600A 1600A - - - -<br />
Note: BRM6-400A instantaneous curren is not adjustable,<br />
overload with long time delay is adjustable.<br />
BRM6-630A with adjustable instantaneous current, overload with long time delay adjustable.<br />
7<br />
Table5<br />
In<br />
-<br />
10<br />
10<br />
10<br />
10<br />
10<br />
10<br />
12<br />
12<br />
12<br />
12<br />
10<br />
10<br />
10<br />
12<br />
12<br />
12<br />
12<br />
12<br />
12<br />
12<br />
12<br />
12<br />
12<br />
12<br />
12<br />
12<br />
12<br />
12<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-
6.2 releaseping Curve<br />
action time<br />
action time<br />
action time<br />
second minute<br />
minute<br />
second<br />
second minute<br />
180<br />
100<br />
50<br />
10<br />
5<br />
1<br />
40<br />
20<br />
10<br />
6<br />
4<br />
2<br />
1<br />
0.6<br />
0.4<br />
0.2<br />
0.1<br />
0.06<br />
0.04<br />
0.02<br />
����-125<br />
0.01<br />
1 1.5 2 3 4 5 6 7 8 10 15 20 30 40 50 70 100<br />
180<br />
100<br />
50<br />
10<br />
5<br />
1<br />
40<br />
20<br />
10<br />
6<br />
4<br />
2<br />
1<br />
0.6<br />
0.4<br />
0.2<br />
0.1<br />
0.06<br />
0.04<br />
0.02<br />
current(multiple of commutating current )<br />
����-250<br />
0.01<br />
1 1.5 2 3 4 5 6 7 8 10 15 20 30 40 50 70 100<br />
180<br />
100<br />
50<br />
10<br />
5<br />
1<br />
40<br />
20<br />
10<br />
6<br />
4<br />
2<br />
1<br />
0.6<br />
0.4<br />
0.2<br />
0.1<br />
0.06<br />
0.04<br />
0.02<br />
current(multiple of commutating current )<br />
����-800<br />
0.01<br />
1 1.5 2 3 4 5 6 7 8 10 15 20 30 40 50 70 100<br />
current(multiple of commutating current )<br />
8<br />
action time<br />
action time<br />
second minute<br />
second minute<br />
180<br />
100<br />
50<br />
10<br />
5<br />
1<br />
40<br />
20<br />
10<br />
6<br />
4<br />
2<br />
1<br />
0.6<br />
0.4<br />
0.2<br />
0.1<br />
0.06<br />
0.04<br />
0.02<br />
����-160<br />
0.01<br />
1 1.5 2 3 4 5 6 7 8 10 15 20 30 40 50 70 100<br />
180<br />
100<br />
50<br />
10<br />
5<br />
1<br />
40<br />
20<br />
10<br />
6<br />
4<br />
2<br />
1<br />
0.6<br />
0.4<br />
0.2<br />
0.1<br />
0.06<br />
0.04<br />
0.02<br />
current(multiple of commutating current )<br />
����-630(400)<br />
0.01<br />
1 1.5 2 3 4 5 6 7 8 10 15 20 30 40 50 70 100<br />
current(multiple of commutating current )
6.3Microprocessor Control Panel<br />
Load<br />
indication<br />
ST110-M Intelligentized Electronic Release<br />
Test socket<br />
Ir1<br />
60% 100%<br />
test alarm<br />
Malfunction<br />
indication<br />
Power supply&<br />
self-diagnose<br />
indication<br />
Ir1<br />
60% 100%<br />
Test socket<br />
test alarm<br />
OFF<br />
0.4<br />
0.5<br />
0.6<br />
0.7<br />
0.8<br />
0.9<br />
1.0<br />
F<br />
R<br />
B<br />
M<br />
CURVE<br />
9<br />
0.7<br />
0.8<br />
0.9<br />
1.0<br />
OFF<br />
0.2<br />
0.4<br />
1.0<br />
Overload pre-warning<br />
current<br />
Ip<br />
Curve Selection<br />
Ir2,Ir3 switch<br />
0<br />
F R B M 12ln<br />
2ln 5ln 10ln<br />
ST110-H(ST110-H/F) Microprocessor electronic release's panel<br />
Load<br />
indication<br />
ST110-M(ST110-M/F) Microprocessor electronic release panel<br />
Power supply &<br />
self-diagnose<br />
indication<br />
Malfunction<br />
warning<br />
indication<br />
Against Overload Ir1<br />
Curve designation<br />
RS485 COM port<br />
Earth fault<br />
current<br />
Ir4 switch
IMicroprocess electronic release main function<br />
Main circuit load indication<br />
Power supply indication<br />
Self-diagnose indication<br />
Overload pre-warning indication<br />
Earth fault indication<br />
Thermal memory<br />
Fast set protection character curve<br />
Signal output of the transition ray contact<br />
between breaker and ST-200 Intelligentized<br />
control module<br />
releaseping test<br />
Setting panel parameter<br />
User can reset the protection character<br />
when the main circuit with or without power running<br />
2000<br />
1000<br />
500<br />
200<br />
100<br />
50<br />
20<br />
10<br />
T(S) 5<br />
2<br />
1<br />
0.5<br />
0.2<br />
0.1<br />
0.05<br />
0.02<br />
lr2=1.5lr1<br />
Main function<br />
Electronic release protection character curve<br />
lr4=(0.2~1)Xln<br />
for four pole<br />
0.01<br />
0.2 0.3 0.4 0.5 0.6 0.8 1 2 3 4 5 6 8 10 20 25<br />
XIn<br />
lr1=(0.4-1)Xln<br />
Ts=0.4S<br />
lr2=5lr1<br />
t l=10S<br />
lr2=10lr1<br />
t 6=0.4S F-Curve R-Curve B-Curve M-Curve<br />
lr3=2ln<br />
lr3=5ln lr3=10ln lr3=12ln<br />
The LED in panel indicates 60% 、 80% 、 90% 、 100%.<br />
The LED in panel indicates<br />
The LED in panel indicates<br />
The LED in panel indicates<br />
The LED in panel indicates<br />
Record over-load cumulate caloric effect<br />
Basis on different purpose ,user can choose short-circuit<br />
release's character (curve F、 R、 B、 M)<br />
10<br />
2000<br />
1000<br />
500<br />
200<br />
100<br />
50<br />
20<br />
10<br />
T(S) 5<br />
2<br />
1<br />
0.5<br />
0.2<br />
0.1<br />
0.05<br />
0.02<br />
Overload pre-warning<br />
releaseping alarm<br />
Earth fault alarm<br />
Signal of breaker's on/ off<br />
Test socket<br />
Switch commutating<br />
Switch commutating<br />
Switch commutating<br />
Switch commutating<br />
Switch commutating<br />
lr2=1.5lr1<br />
lr4=(0.2~1)Xln<br />
for four pole<br />
t 6=0.4S F-Curve R-Curve<br />
lr1=(0.4-1)Xln<br />
t =10S<br />
l<br />
lr2=5lr1 lr2=10lr1<br />
B-Curve<br />
0.01<br />
0.2 0.3 0.4 0.5 0.6 0.8 1 2<br />
XIn<br />
3 4 5 6 8 10 20 25<br />
Table 6<br />
M-Curve<br />
lr3=2ln lr3=5ln lr3=10ln lr3=12ln
<strong>Protection</strong> performance of residual current release<br />
<strong>Protection</strong> performance of circuit breaker's residual current release for power distribution:<br />
No.<br />
1<br />
2<br />
Test current type<br />
Engaged<br />
non-release current<br />
Engaged release<br />
current<br />
I/ In<br />
1.05<br />
1.30<br />
11<br />
Engaged time endurance Start state<br />
2h(In>63A)<br />
1h(In≤63A)<br />
2h(In>63A)<br />
1h(In≤63A) Protective performance of circuit breaker's residual current release for motor protection:<br />
No.<br />
1<br />
2<br />
Test current type<br />
Engaged non-release current<br />
Engaged release current<br />
I/ In<br />
1.0<br />
1.2<br />
1.5<br />
7.2<br />
>2h<br />
≤2h<br />
≤2min(In≤200A)<br />
≤4min(200A
7 installation type: Fixed , Plug-in , Draw-out type<br />
Frame rated current<br />
125A<br />
160A<br />
250A<br />
630A(400A)<br />
800A<br />
1250A<br />
1600A<br />
3p 4p<br />
7.1 Breaker’s installation dimensions<br />
7.1.1 Fixed type’s installation dimensions<br />
Fixed type BRM6-125~160<br />
Connect wire in front of board<br />
Type<br />
BRM6-125<br />
BRM6-160<br />
X<br />
D<br />
25<br />
30<br />
L1<br />
L2<br />
L1<br />
120<br />
120<br />
Y<br />
W1(4P)<br />
W2(3P)<br />
D D D<br />
L2<br />
48<br />
48<br />
Y<br />
L3<br />
102<br />
102<br />
12<br />
Installation<br />
Fixed Plug in Draw-out<br />
L4<br />
45<br />
45<br />
L5<br />
62<br />
62<br />
L3<br />
≥3<br />
H<br />
L6<br />
100<br />
100<br />
3p 4p 3p<br />
4p<br />
H3<br />
H2<br />
H1<br />
H4<br />
W1<br />
101<br />
120<br />
W2<br />
76<br />
90<br />
L4<br />
H<br />
25.5<br />
27.5<br />
H1<br />
67.5<br />
68.5<br />
D<br />
D<br />
H2<br />
70<br />
71<br />
H3<br />
91<br />
93<br />
L5<br />
L6<br />
H4<br />
X<br />
75.5<br />
76.5<br />
Table:9<br />
4.5<br />
4.5
Overall and installation dimension<br />
Fixed type BRM6-250~1600<br />
Connect wire in front of board<br />
Type<br />
BRM6-250<br />
BRM6X-250<br />
X<br />
D L1 L2 L3 L4 L5 L6 W1 W2 H H1 H2 H3 H4 Φ L7 Φ1<br />
35 170 87.25 206 105 73.75 139 140 105 25 101.5 103.5 135 113 5.5 10.8 8.5<br />
Fixed type BRM6-630(500A、 630A)<br />
Connect wire in front of board<br />
L1<br />
Y<br />
W1(4P)<br />
W2(3P)<br />
D D D<br />
Y<br />
L3<br />
54<br />
183.75(4P)<br />
140(4P)<br />
54 54<br />
≥3<br />
H<br />
13<br />
H3<br />
H2<br />
H1<br />
H4<br />
L4<br />
Φ Φ<br />
D D<br />
35 255 87.25 278.5 105 154.5 224 140 105 25 101.5 103.5 135 113 5.5 10.8 8.5<br />
BRM6-630(400A) 43.75 254 124.25 281 105 107.25 214 140 183.75 25 101.5 103.5 135 113 5.5 12 14<br />
BRM6-800 70 268 142.75 241 105 109.25 237 280 210 23 101.5 103.5 167.5 115 5.5 10.0 11<br />
BRM6X-800 70 406 142.75 479 105 256.5 375 280 210 23 101.5 103.5 167.5 115 5.5 10.0 11<br />
BRM6-1600 70 406 189 513 105 203 378 280 210 39 137 138.5 204.5 152 5.5 13.5 11<br />
13<br />
304<br />
Φ12<br />
2.54<br />
31.0<br />
135.0<br />
101.5<br />
43.75<br />
Φ5.5<br />
L5<br />
L6<br />
21.4<br />
X
Iinstallation dimension<br />
Fixed type BRM6-125-800 BRM6X-250<br />
Connect wire behind board<br />
Fixed type BRM6-630(500A、 630A) BRM6-1600<br />
Connect wire in front of board<br />
X<br />
406<br />
X<br />
217<br />
D D D<br />
70<br />
Y<br />
280<br />
210<br />
105<br />
L1<br />
L2<br />
L3<br />
L4<br />
(4POL)<br />
(3POL)<br />
315<br />
171.5<br />
14<br />
L6<br />
L5<br />
85 204.5<br />
≥3<br />
138.5<br />
105<br />
378<br />
203<br />
315<br />
171.5<br />
D D D<br />
Type Φ1<br />
BRM6-125<br />
BRM6-160<br />
BRM6-250<br />
BRM6X-250<br />
BRM6-630(400)<br />
BRM6-800<br />
D<br />
25<br />
30<br />
35<br />
35<br />
43.75<br />
70<br />
L1<br />
50<br />
50<br />
85.25<br />
85.25<br />
131.25<br />
145.25<br />
70 70<br />
Y<br />
L2<br />
124<br />
124<br />
175<br />
255<br />
259<br />
273<br />
L3<br />
102<br />
102<br />
145<br />
224<br />
218<br />
241<br />
L4<br />
39<br />
39<br />
73.75<br />
123.5<br />
107.25<br />
117.25<br />
L5<br />
43<br />
43<br />
55<br />
55<br />
55<br />
55<br />
L6<br />
76<br />
76<br />
105<br />
105<br />
105<br />
74.5<br />
70<br />
Y<br />
70<br />
70 70 70<br />
Y<br />
35<br />
X<br />
18<br />
18<br />
24<br />
24<br />
30<br />
50<br />
X<br />
R40<br />
5
Installation Dimension<br />
Plug-in version BRM6-128-160<br />
Connect wire in front of board<br />
Type<br />
BRM6-125<br />
BRM6-160<br />
X<br />
L1<br />
Y<br />
D D D<br />
Y<br />
L2<br />
15<br />
H2<br />
H1<br />
D D<br />
D L1 L2 L3 L4 H1 H2<br />
25<br />
30<br />
Plug-in version BRM6-250-630<br />
Connect wire in front of board<br />
Type<br />
BRM6-250<br />
BRM6-630(400)<br />
X<br />
L5 L4<br />
L3<br />
L2<br />
L1<br />
25<br />
30<br />
163<br />
163<br />
≥3 31<br />
84<br />
84<br />
H1<br />
H2<br />
144<br />
144<br />
Ф<br />
123<br />
123<br />
W4(4P)<br />
W4(4P)<br />
Y<br />
L1 L2 L3 L4 L5 L6 L7 W1 W2 W3 W4 W5 W6 H1 H2<br />
89.7<br />
127.75<br />
175<br />
259<br />
107.25<br />
150.75<br />
210<br />
305<br />
10<br />
14<br />
52.25<br />
65.75<br />
100<br />
135<br />
140<br />
183.75<br />
105<br />
140<br />
35 105<br />
43.75 160<br />
105<br />
160<br />
Y W6<br />
25<br />
58<br />
153<br />
153<br />
L7<br />
L3<br />
L6<br />
Ф<br />
L4<br />
52<br />
52<br />
184.5<br />
184.5<br />
X<br />
X<br />
Ф<br />
5<br />
6
Installation Dimension<br />
Plug-in version BRM6-630(500A,630A)<br />
Curved patch panel<br />
Plug-in version BRM6-125-630<br />
Connect wire in front of board<br />
Type<br />
BRM6-125<br />
BRM6-160<br />
BRM6-250<br />
BRM6X-250<br />
BRM6-630<br />
X<br />
L1<br />
12<br />
332<br />
D<br />
266<br />
Y<br />
D D<br />
Y<br />
183.75(4 P)<br />
140(3 P)<br />
54 54<br />
L2<br />
L3<br />
L4<br />
54<br />
H4<br />
H3<br />
16<br />
H2<br />
33.8<br />
H4<br />
R<br />
55.0<br />
170.0<br />
35.0<br />
135.0<br />
3D<br />
2D<br />
D D<br />
D L1 L2 L3 L4 L5 L6 H1 H2 H3 H4 H5<br />
25 70 163 102 39 84 144 123 52 50 80 13<br />
30 70 163 102 39 84 144 123 52 50 80 13<br />
35 85.25 175 143 69.2 52.5 100 184.5 83 52 96 14<br />
35 85.25 175 143 69.2 52.5 100 184.5 83 52 96 14<br />
43.75 131.25 259 218 110.75 107.25 218 184.5 83 55 100 14<br />
115.0<br />
L5<br />
L6<br />
X
Installation dimension<br />
Draw-out version BRM6-250~630<br />
Connect wire in front of board<br />
Y<br />
X L6<br />
L5<br />
H1<br />
H2<br />
31 ≥3 Y<br />
L4<br />
L3<br />
L2<br />
Type L1 L2 L3 L4 L5 L6 L7 L8 L9 W1 W2 W3 W4 W5 H1 H2 Φ<br />
BRM6-250 89.75 175 107.25 210 1.75 105 52.25 100 - 84 105 70 25 - 167 190 5<br />
BRM6-630 127.75 259 150.75 305 1.75 105 65.75 135 - 101.5 160 115 58 - 167 190 6<br />
Draw-out version BRM6-800~1600<br />
Connect wire in front of board<br />
X<br />
L4<br />
L3<br />
L9<br />
L2<br />
L1<br />
W5<br />
Y<br />
Y<br />
W1<br />
Type L1 L2 L3 L4 L5 L6 L7 L8 L9 W1 W2 W3 W4 W5 H1 H2 Φ<br />
BRM6-800 133 295 158 345 14.5 140 45.5 120 20 136.5 210 210 140 193.5 167 190 8.5<br />
BRM6-1600 211.25 406 268.25 520 8.25 140 68.25 120 - 136.5 210 210 140 193.5 218.5 241.5 8.5<br />
L1<br />
≥3<br />
Φ<br />
17<br />
31<br />
H1<br />
H2<br />
Y<br />
W1<br />
Y<br />
Φ<br />
X<br />
W2(4P)<br />
W3(3P)<br />
W4<br />
Y<br />
W2(4P)<br />
W3(3P)<br />
W4<br />
Φ<br />
Φ<br />
L8<br />
L8<br />
L7<br />
L7<br />
X<br />
X
Installation dimension<br />
Draw-out version<br />
Connect wire in front of board<br />
Type<br />
BRM6-250<br />
BRM6X-250<br />
BRM6-630<br />
X<br />
L1<br />
175<br />
175<br />
259<br />
L6<br />
L2<br />
87.75<br />
87.75<br />
127.75<br />
L5<br />
L3<br />
143<br />
143<br />
218<br />
H1<br />
H2<br />
L4<br />
73.75<br />
73.75<br />
107.25<br />
Plug-in version BRM6-800<br />
Rear connection<br />
X<br />
140<br />
14.5<br />
167<br />
190<br />
Plug-in version BRM6-1600<br />
Rear connection<br />
X<br />
140<br />
8.25<br />
L5<br />
1.75<br />
1.75<br />
1.75<br />
≥3<br />
218.5<br />
241.5<br />
≥3<br />
58<br />
L6<br />
105<br />
105<br />
105<br />
80.5<br />
145 max<br />
108<br />
145<br />
160<br />
H3<br />
H4<br />
L7<br />
52.25<br />
52.25<br />
65.75<br />
89.5<br />
143.25<br />
208<br />
270<br />
295<br />
L4<br />
L8<br />
100<br />
100<br />
135<br />
133<br />
406<br />
273<br />
211.25<br />
122<br />
L3<br />
18<br />
L1<br />
W1<br />
84<br />
84<br />
101.5<br />
70<br />
L2<br />
W2<br />
105<br />
105<br />
160<br />
193.5<br />
W3<br />
70<br />
70<br />
115<br />
280<br />
210<br />
70 70<br />
Y<br />
Y<br />
123.5 136.5<br />
Y<br />
280<br />
210<br />
140<br />
123.5 136.5<br />
193.5<br />
Y<br />
W1<br />
W4<br />
70<br />
70<br />
87.5<br />
(4P)<br />
(3P)<br />
(4P)<br />
(3P)<br />
120.5<br />
92.5<br />
76<br />
120.5<br />
W5<br />
105<br />
105<br />
131.25<br />
77.5 86.5 57.5 77.5<br />
120<br />
120<br />
H1<br />
167<br />
167<br />
167<br />
Y<br />
140<br />
210<br />
Φ8.5(M8)<br />
W2(4P)<br />
W3(3P)<br />
W4(4P)<br />
W5(3P)<br />
H2<br />
190<br />
190<br />
190<br />
Y<br />
140<br />
210<br />
70<br />
Φ8.5(M8)<br />
107<br />
214<br />
284<br />
Y<br />
107<br />
214<br />
284<br />
(4P)<br />
(3P)<br />
(4P)<br />
(3P)<br />
(3P)<br />
(4P)<br />
68.25<br />
X<br />
4<br />
L7<br />
L8<br />
Φ<br />
H3<br />
52<br />
52<br />
55<br />
45.5<br />
4<br />
(3P)<br />
(4P)<br />
X<br />
X<br />
H4<br />
96<br />
96<br />
100<br />
Φ<br />
5<br />
6<br />
6
8 Motor Operator<br />
8.1 Motor operator<br />
Frame rated current<br />
100A<br />
160A<br />
250A<br />
630(400A)<br />
800A<br />
1600A<br />
1. Motor operator is used to remote control the closing of the breaker<br />
2.The specification of motor operator (Table10)<br />
8.1.1 CD1 direct action motor operator<br />
The accessory of electric operation<br />
The range of operating voltage<br />
Rated control voltage<br />
Power<br />
supply<br />
Close time<br />
Cut off time<br />
Model of motor operator<br />
CD1 CD2 CD3<br />
-<br />
CD2-100<br />
-<br />
-<br />
CD2-160<br />
-<br />
CD1-250<br />
-<br />
-<br />
CD1-400<br />
-<br />
-<br />
-<br />
-<br />
CD3-800<br />
-<br />
-<br />
CD3-1600<br />
1.Both the opening and closing commandis controlled by<br />
the motor, which acts di-rectly on the circuit-breaker<br />
AC 50 Hz<br />
DC<br />
19<br />
motor operation device<br />
(0.85-1.1)XUs<br />
220V 380V<br />
510VA<br />
510VA<br />
360VA<br />
360VA<br />
110V<br />
220V<br />
510W<br />
510W<br />
360W<br />
360W<br />
0.1s<br />
0.1s<br />
Table10<br />
lever. Thetable shows the power supply voltage values Un [V] .<br />
2.With manual urgent cut off button.<br />
3.User can install break-position lock ,avoid the breaker being<br />
closed.<br />
4.Apply to ①Inm=250A ②Inm=630A(400A)<br />
Customer should indicate the specification in order.<br />
5. Accessories for selecting<br />
Cd1 motor operator power supply<br />
Power<br />
consumption<br />
Power<br />
consume<br />
Start Power consume<br />
Continuance Power<br />
consume<br />
Start Power consume<br />
Continuance Power<br />
consume<br />
Table11
8.1.2 CD2 motor operator<br />
Rated control voltage<br />
The accessory of electric operation<br />
The range of operating voltage<br />
Power<br />
supply<br />
Close time<br />
Cut off time<br />
Power<br />
consume<br />
Power<br />
consume<br />
1.Direct close or cut off close or cut off.<br />
2.With manual urgent cut off button.<br />
3. Apply to ①Inm=125A ②Inm=160A<br />
Customer should indicate the specification in order.<br />
4.Accessories for selecting.<br />
AC 50 Hz<br />
Start Power consumption<br />
DC<br />
Continuance Power<br />
consumption<br />
Start Power consumption<br />
Continuance Power<br />
consumption<br />
20<br />
motor operation device<br />
(0.85-1.1)XUs<br />
220V 380V<br />
220VA<br />
200VA<br />
110VA<br />
110VA<br />
110V<br />
220V<br />
200W<br />
200W<br />
110W<br />
110W<br />
0.1s<br />
0.1s<br />
Table12<br />
8.1.3 CD3 Stored energy motor operator<br />
1.Motor pre-storage and manual pre-storage.<br />
2.Electric close.<br />
3.When user needs close the breaker, make sure the storage<br />
is finished firstly, then cut off the breaker.<br />
4.Electric cut off function<br />
5.Manual urgent cut off button<br />
6.User can install break-position lock ,avoid the breaker being<br />
closed.<br />
7. Apply to ①Inm=800A ②Inm=1250A<br />
③Inm=1600A<br />
Customer should indicate the specification in order.<br />
8. Accessories for selecting<br />
Rated control voltage<br />
The accessory of electric operation<br />
The range of operating voltage<br />
Power<br />
supply<br />
Close time<br />
Cut off time<br />
Power<br />
consume<br />
Power<br />
consume<br />
CD2 motor operatorr<br />
CD3 Stored energy motor operator<br />
AC 50 Hz<br />
DC<br />
Start Power consume<br />
Continuance Power<br />
consume<br />
Start Power consume<br />
Continuance Power<br />
consume<br />
motor operation device<br />
(0.85-1.1)XUs<br />
220V 380V<br />
660VA<br />
660VA<br />
180VA<br />
180VA<br />
110V<br />
220V<br />
600W<br />
600W<br />
180W<br />
180W<br />
0.1s<br />
0.3s<br />
Table13
8.2 Rotary handle operation Mechanism<br />
Rotary handle operation mechanism can apply to:<br />
①Use<br />
the rotary handle to close or cut off the breaker.<br />
②Use<br />
the rotary handle outside of the switch box to close or cut off the breaker.<br />
③The<br />
rotary handle operation device is interlocked with switch box ,avoid opening the box's door when<br />
breaker is closing.<br />
User can install break-position lock ,avoid the breaker closing.<br />
Supply condition:<br />
①One<br />
breaker equipped separate lock and key.<br />
②2<br />
breakers equipped 2 same locks and 1 key.<br />
③3<br />
breakers equipped 3 same locks and 2 keys.<br />
Specification of rotary handle operation device.<br />
Model of rotary handle operation mechanism<br />
Model of rotary handle operation mechanism for selection<br />
Frame<br />
rated<br />
current<br />
<strong>Device</strong> in breaker<br />
<strong>Device</strong> in switch box's door (for selecting:handle and operation device)<br />
Rotary Handle<br />
operation device<br />
CS2 CS2/L Model A(round) Model B(rectangle) Model CS1(central) Model CSS(eccentricity)<br />
with inter lock<br />
A-1 short<br />
handle<br />
A-2 long<br />
handel<br />
F1-1 short<br />
handle<br />
F1-2 short<br />
handle CS1<br />
CS1/L with<br />
interlock<br />
CSS<br />
CSS/L with<br />
interlock<br />
63A<br />
-<br />
- A-1 - F1-1 -<br />
-<br />
- CSS-63 CSS/L-63<br />
100A<br />
-<br />
-<br />
A-1 - F1-1 -<br />
-<br />
- CSS-100 CSS/L-100<br />
160A<br />
-<br />
-<br />
A-1 - F1-1 -<br />
-<br />
- CSS-160 CSS/L-160<br />
250A CS2-250 CS2/L-250 A-1 - F1-1 - CS1-250 CS1/L-250 CSS-250 CSS/L-250<br />
600A(400A) CS2-400 CS2/L-400 A-1 - F1-1 - CS1-400 CS1/L-400 CSS-400 CSS/L-400<br />
800A CS2-800 CS2/L-800 - A-2 - F1-2 CS1-800 CS1/L-800 CSS-800 CSS/L-800<br />
1600A CS2-1600 CS2/L-1600 - A-2 - F1-2 CS1-1600 CS1/L-1600 CSS-1600 CSS/S-1600<br />
8.2.1 CSS rotary handle operation device<br />
CSS-63A~160A<br />
Rotary handle operation mechanism<br />
Eccentric connecting lever. <strong>Device</strong> in breaker. Can equip model A or model F handle.<br />
Can equip interlock device with switch box's door. Accessories for selecting.<br />
21<br />
CSS-250A~1600A<br />
Rotary handle operation mechanism<br />
Table14
8.2.2 Rotary handle operation mechanism<br />
CS2<br />
Rotary handle operation device<br />
8.2.3 Model A handle<br />
Short handle.<br />
Equip in switch box's door.<br />
Can apply to model CS1\CSS operation<br />
device.<br />
Safty category :IP30<br />
Accessories for selecting.<br />
8.2.4 Model F1-1 handle<br />
Short handle.<br />
Equip in switch box's door.<br />
Can apply to model CS1\CSS operation<br />
device<br />
Safty category :IP30(can offer IP54 handle)<br />
Accessories for selecting.<br />
<strong>Device</strong> in breaker.<br />
With break-position lock.<br />
Can equip interlock device with switch box's door.<br />
Accessories for selecting.<br />
F1-1 handel A-2 handel<br />
A1-1 handel<br />
22<br />
Long handle.<br />
Equip in switch box's door.<br />
Can apply to model CS1\CSS<br />
operation device.<br />
Safty category :IP30<br />
Accessories for selecting.<br />
F1-2 handel<br />
Long handle.<br />
Equip in switch box's door.<br />
Can apply to model CS1\CSS<br />
operation device.<br />
Safty category:IP30(can offer IP54<br />
handle)<br />
Accessories for selecting.
9 Accessory<br />
Left side<br />
of breaker<br />
Installation position of accessory<br />
Name of accessory Code of accessory<br />
Warning contact<br />
Shunt release<br />
Shunt release & warning contact<br />
Auxiliary contact<br />
Auxiliary contact & warning contact<br />
Under-voltage release<br />
Under-voltage release & warning contact<br />
Shunt release & auxiliary contact<br />
Shunt release & auxiliary contact & warning contact<br />
2-group auxiliary contact<br />
2-group auxiliary contact & 1 warning contact<br />
(apply to 630A-1600A)<br />
Under-voltage release & auxiliary contact<br />
Under-voltage release & auxiliary contact &<br />
warning contact<br />
208 308 408<br />
210 310 410<br />
218 318 418<br />
220 320 420<br />
228 328 428<br />
230 330 430<br />
238 338 438<br />
240 340 440<br />
248 348 448<br />
260 360 460<br />
268 368 468<br />
270 370 470<br />
278 378 478<br />
23<br />
middle of<br />
breaker<br />
Right side<br />
of breaker<br />
Installation position of accessory<br />
Left Middle Right<br />
Shunt<br />
Shunt<br />
Under-voltage<br />
Under-voltage<br />
Shunt<br />
Shunt<br />
Under-voltage<br />
Under-voltage<br />
Warning<br />
Warning<br />
Auxiliary<br />
Auxiliary<br />
+<br />
warning<br />
Warning<br />
Auxiliary<br />
Auxiliary<br />
+<br />
warning<br />
2-Auxiliary<br />
Auxiliary<br />
+<br />
warning<br />
Auxiliary<br />
Auxiliary<br />
+<br />
warning<br />
Table 15
9.1 Shunt release<br />
Shunt release is used for remote controlling the<br />
breaker to cut off.<br />
There are three frames specifications of shunt release :<br />
①apply<br />
to Inm=63A-160A<br />
②apply<br />
to Inm=250A-630A<br />
③apply<br />
to Inm=800A-1600A<br />
Customer should indicate the specification in order.<br />
For instantaneous work type selecting accessory.<br />
Shunt release character<br />
The accessory of electric operation Shunt release<br />
The range of operating voltage<br />
Rated control voltage Power supply<br />
AC 50HZ<br />
Power consumption<br />
DC<br />
Power consumption<br />
24<br />
(0.7-1.1)XUs<br />
220V 380V<br />
150VA 150VA<br />
110V 220V<br />
150W 150W<br />
9.2 Under-voltage release<br />
Under-voltage release is used for protecting the circuit and power supply's under-voltage.<br />
Under-voltage release can be used as shunt release<br />
There are three frames specifications of under-voltage release :<br />
①apply<br />
to Inm=63A-160A<br />
②apply<br />
to Inm=250A-630A<br />
③apply<br />
to Inm=800A-1600A<br />
Rated work voltage Ue(V)<br />
Action voltage<br />
Guarantee close voltage<br />
Guarantee no-close voltage<br />
Power consumption<br />
Under-voltage release action character<br />
AC380 AC220 DC110<br />
Table 17<br />
DC220<br />
(0.35-0.7)XUe<br />
(0.85-1.1)XUe<br />
≤0.35Ue<br />
10VA 4W<br />
Table 16<br />
63A-160A under-voltage inlay release 63A-160A under-voltage release 250A-400A under-voltage release 630A-1600A under-voltage release
9.3 Auxiliary contact & warning contact<br />
63A<br />
125A<br />
160A<br />
250A<br />
630A(400A)<br />
800A<br />
1600A(1250A)<br />
4A<br />
8A<br />
Auxiliary contact is used for auto controlling the breaker's<br />
control loop,such as the indication of breaker's on or off.<br />
Warning contact is used for alarming of the breaker's<br />
cut off when overload、 short-circuit、 under voltage of<br />
circuit and equipment .<br />
The specification of auxiliary contact & warning contact:<br />
① 1 often-on 1 often-off<br />
② 2 often-on 2 often-off<br />
③ 1 often-on 1 often-off+ 1 warning contact<br />
④ 2 often-on 2 often-off+ 1 warning contact<br />
(only apply to 800A-1600A )<br />
There are three frames specifications of auxiliary contact & warning contact :<br />
① apply to Inm=63A-160A<br />
② apply to Inm=250A-630A<br />
③ apply to Inm=800A-1600A<br />
Customer should indicate the specification in order.<br />
9.4 Main technical parameters<br />
Frame rated current<br />
10<br />
Order instructions<br />
Stipulation heat<br />
current<br />
Rated insulation<br />
voltage<br />
24<br />
AC250V<br />
AC380V<br />
AC380V AC220V DC220V<br />
-<br />
3.5A<br />
Rated work voltage Ue<br />
3A 0.14A<br />
6A 0.2A<br />
Table 18<br />
When order, please indicate the model 、 model of release、 frame rated current、 code of breaking capacity、<br />
rated current、 number of poles、 usage、 connection type、 control device、 inside accessory、 category<br />
and quantity.