User's Guide, Kodak s1220 Photo Scanning System, A ... - Database

User's Guide, Kodak s1220 Photo Scanning System, A ... - Database User's Guide, Kodak s1220 Photo Scanning System, A ... - Database

A-61601<br />

Part No. 9E4780<br />

<strong>s1220</strong> <strong>Photo</strong> <strong>Scanning</strong> <strong>System</strong><br />

User’s <strong>Guide</strong>


This product contains portions of imaging code owned and copyrighted by Pegasus Imaging Corp., Tampa, FL,<br />

(www.pegasustools.com). ALL RIGHTS RESERVED.


Contents<br />

1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1<br />

Supporting documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1<br />

Product features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1<br />

<strong>System</strong> requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2<br />

Installing the software. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3<br />

Using this manual. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9<br />

Starting the application software. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10<br />

Exiting the application software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10<br />

2 Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1<br />

Customer & Order Information screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1<br />

Scan Images screen. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3<br />

Continue Scan Images screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4<br />

Enhance Picture screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5<br />

Order Preview screen. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7<br />

Preview Details screen. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8<br />

Order Summary & Creation screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9<br />

3 Using the Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1<br />

Handling guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1<br />

Starting the software and using the scanning system . . . . . . . . . . . . . . . . 3-2<br />

4 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1<br />

Error code listing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2<br />

Problem solving . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3<br />

Getting service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3<br />

A-61601 July 2007 i


1 Introduction<br />

Supporting<br />

documentation<br />

The <strong>Kodak</strong> <strong>s1220</strong> <strong>Photo</strong> <strong>Scanning</strong> <strong>System</strong> allows you to make<br />

digitizing photos easy! The <strong>Kodak</strong> <strong>Photo</strong> <strong>Scanning</strong> Software combined<br />

with the <strong>Kodak</strong> <strong>s1220</strong> Scanner allows you to scan photos, remove red<br />

eye, retouch and rotate images, and apply image sharpening if desired.<br />

Once the images are scanned, the images can be used in a variety of<br />

ways; e.g., printed, emailed, written to a CD/DVD, or uploaded to<br />

<strong>Kodak</strong> Easyshare Gallery or other photo management system for<br />

sharing and printing.<br />

This chapter provides a brief overview of product features, system<br />

requirements, instructions for installing the software, an overview of<br />

what information you will find in other chapters of this User’s <strong>Guide</strong> and<br />

procedures for logging into and exiting the software.<br />

This User’s <strong>Guide</strong> provides information on how to use the <strong>Kodak</strong> <strong>s1220</strong><br />

<strong>Photo</strong> <strong>Scanning</strong> <strong>System</strong>.<br />

The User’s <strong>Guide</strong> for the <strong>Kodak</strong> i1200/i1300 Series Scanners, A-61560<br />

(included with the <strong>Kodak</strong> s1200 <strong>Photo</strong> <strong>Scanning</strong> <strong>System</strong>) provides<br />

information and procedures for using the <strong>Kodak</strong> <strong>s1220</strong> Scanner. Refer<br />

to the <strong>Kodak</strong> i1200/i1300 Series Scanners User’s <strong>Guide</strong> for any<br />

maintenance and troubleshooting information you need for the scanner.<br />

Periodically, you will have to clean the scanner and change the<br />

separation module. Chapter 5, in the scanner User’s <strong>Guide</strong> (A-61560)<br />

provides maintenance information.<br />

Product features The <strong>Kodak</strong> <strong>s1220</strong> <strong>Photo</strong> <strong>Scanning</strong> <strong>System</strong> provides the following<br />

features:<br />

• captures both the front and back of photos at the same time or just<br />

fronts or backs<br />

• scans up to 30 (front and back), 4 x 6” photos per minute at 300 dpi<br />

resolution<br />

• handles photos from 2.5 x 3.5” (wallet size) to 8 x 10”<br />

• can use the <strong>Kodak</strong> A4 Flatbed Accessory to safety scan fragile and<br />

precious photos<br />

• provides a user friendly interface which allows you to scan and<br />

enhance your photos<br />

• allows you to rotate images 90, 180 or 270 degrees<br />

• allows you to remove red eye<br />

• provides a choice of resolutions: 300, 600 or 1200 dpi<br />

• stores JPEG compressed images as .jpg files for printing, emailing or<br />

uploading to a photo management system<br />

• supports the optional flatbed accessory<br />

A-61601 July 2007 1-1


<strong>System</strong> requirements Following is the minimum recommended system configuration to run<br />

the <strong>Kodak</strong> <strong>s1220</strong> <strong>Photo</strong> <strong>Scanning</strong> <strong>System</strong>:<br />

• Intel Pentium IV, 3.2 GHz processor, 250 MB free hard disk space, 1<br />

GB RAM for 300 dpi or 3 GB RAM for 600 and 1200 dpi<br />

• Two USB 2.0 ports (1 for the scanner, 1 for the WIBU key)<br />

• Microsoft Windows XP, Service Pack 2; Windows 2000 Professional;<br />

Windows Vista — all supporting USB 2.0 with administrator privileges<br />

for installation<br />

• Microsoft .Net Framework 2.0 (included on the installation CD)<br />

NOTE: Depending on how you choose to manage the images after<br />

scanning, you will need supporting devices such as CD/DVD<br />

Writers, photo printers, etc.<br />

1-2 A-61601 July 2007


Installing the<br />

software<br />

• Install the software before connecting the scanner to the PC.<br />

• Be sure you have administrator rights. The <strong>s1220</strong> <strong>Photo</strong> <strong>Scanning</strong><br />

<strong>System</strong> application must be installed under Administrator and run<br />

under Administrator or Standard groups.<br />

• Close any currently running applications that use a WIBU security<br />

key before starting the <strong>s1220</strong> <strong>Photo</strong> <strong>Scanning</strong> <strong>System</strong> installation.<br />

1. Place the <strong>s1220</strong> <strong>Photo</strong> <strong>Scanning</strong> <strong>System</strong> installation CD in the<br />

CD-ROM drive. The software installation will automatically start. If<br />

the software does not auto start, access the drive where the<br />

installation and application CD is inserted and browse to the<br />

INSTALLSTW.exe file on the root directory of the CD.<br />

NOTE: If a security software application is installed on the PC, you<br />

will be asked to Allow or Deny the <strong>s1220</strong> <strong>Photo</strong> <strong>Scanning</strong><br />

<strong>System</strong> from installing or running, select Allow or Yes. If<br />

you inadvertently select Deny or No, open the security<br />

software application and set the permission to Allow the<br />

application to install and run.<br />

A-61601 July 2007 1-3


2. Click Next. The Software Licence screen will be displayed.<br />

3. Read the License Agreement and click Next.<br />

The Select Destination Directory screen will be displayed.<br />

4. Click Next or click Browse if you want to install the software in a<br />

directory other than the default.<br />

1-4 A-61601 July 2007


The installation will begin.<br />

During the installation, the Browse dialog box will be displayed.<br />

5. If you want to store the scanned images in the default C:/<br />

Scanned_Pictures default directory, click Next. Otherwise, click<br />

Browse to go to the directory where you want to store your scanned<br />

images, or enter a new folder name where you want to store the<br />

images, then click OK. See Chapter 4, “Application configuration”<br />

for information on changing the Scanned Images folder after<br />

installation.<br />

The following messages will be displayed.<br />

A-61601 July 2007 1-5


The WIBU-KEY Setup screen will be displayed.<br />

NOTE: Do not install the WIBU key at this time.<br />

6. Click Next.<br />

The Language screen will be displayed.<br />

7. Select the desired language and click Next.<br />

1-6 A-61601 July 2007


The following screen will be displayed.<br />

8. Click Next. A message will be displayed asking if you want to create<br />

the folder, click Yes to continue. The following screen will be<br />

displayed.<br />

9. Click Next. The following screen will be displayed.<br />

A-61601 July 2007 1-7


10.Click Next. The following screen will be displayed.<br />

11. Click Finish.<br />

12.Click OK on the Setup screen when the installation is complete.<br />

When WIBU has been installed, the Installation Complete screen<br />

will be displayed.<br />

13.Insert the WIBU key into the USB port of the PC.<br />

1-8 A-61601 July 2007


14.Connect the USB cable to the scanner and the PC.<br />

15.If you have an optional <strong>Kodak</strong> A4 Flatbed, connect the flatbed cable<br />

to scanner.<br />

16.Turn on the scanner.<br />

The PC will recognize the scanner and optional flatbed. Follow any<br />

prompts.<br />

Using this manual This User’s <strong>Guide</strong> describes the functions and procedures of the <strong>Kodak</strong><br />

<strong>s1220</strong> <strong>Photo</strong> <strong>Scanning</strong> <strong>System</strong>.<br />

Chapter 2, Getting Started — describes the screens and tools that are<br />

available when using the <strong>s1220</strong> <strong>Photo</strong> <strong>Scanning</strong> <strong>System</strong>.<br />

Chapter 3, Using the Software — provides procedures for using the<br />

features and functionality of the <strong>s1220</strong> <strong>Photo</strong> <strong>Scanning</strong> <strong>System</strong>.<br />

Chapter 4, Troubleshooting — provides an error code listing, a list of<br />

potential problems you may encounter when using the <strong>Kodak</strong> <strong>Photo</strong><br />

<strong>Scanning</strong> Software and instructions on how to contact <strong>Kodak</strong> Service.<br />

NOTE: For information on how to use the <strong>Kodak</strong> <strong>s1220</strong> Scanner, Scan<br />

Validation Tool or smart touch functionality, refer to the User’s<br />

<strong>Guide</strong> for the <strong>Kodak</strong> i1200/i1300 Series Scanners, A-61560<br />

(included with your <strong>s1220</strong> <strong>Photo</strong> <strong>Scanning</strong> <strong>System</strong>).<br />

A-61601 July 2007 1-9


Starting the<br />

application software<br />

Exiting the<br />

application software<br />

• Double-click on the application shortcut on your desktop or select<br />

Programs><strong>Kodak</strong>>Document Imaging><strong>s1220</strong> <strong>Photo</strong> <strong>System</strong>><br />

<strong>s1220</strong> <strong>Photo</strong> Scanner. The Customer Information screen will be<br />

displayed.<br />

To exit the software:<br />

• Click the Exit icon in the lower-right hand corner on any screen or<br />

click the Close box in the upper right-hand corner.<br />

1-10 A-61601 July 2007


2 Getting Started<br />

Customer & Order<br />

Information screen<br />

This chapter describes the screens and icons that are available when<br />

using the <strong>Kodak</strong> <strong>s1220</strong> <strong>Photo</strong> <strong>Scanning</strong> <strong>System</strong>.<br />

All screens within the <strong>Kodak</strong> <strong>s1220</strong> <strong>Photo</strong> <strong>Scanning</strong> <strong>System</strong> provide the<br />

following icons:<br />

About: displays the software version and copyright information.<br />

Exit: closes the <strong>Kodak</strong> <strong>s1220</strong> <strong>Photo</strong> <strong>Scanning</strong> <strong>System</strong>.<br />

A message area is provided on all screens in the title bar.<br />

Messages are displayed in this area<br />

When you launch the <strong>s1220</strong> <strong>Photo</strong> <strong>Scanning</strong> <strong>System</strong> application<br />

software, the Customer & Order Information screen will be displayed.<br />

Order # — this number is prefixed with the date and time and is<br />

appended with any text you want to add for your own reference. An<br />

entry must be made in this field. Up to 51 alphanumerical characters<br />

are allowed in this field.<br />

A-61601 July 2007 2-1


Customer Information — enter the customer name, address and<br />

email address information. You do not need to make an entry in these<br />

fields.<br />

• Up to 64 characters are allowed in the Last, First, Street, and City<br />

fields.<br />

• Up to 20 characters are allowed in the State/County/Country and<br />

Phone fields.<br />

• If you enter an email address, it must be a valid email address<br />

format.<br />

• Up to 10 numeric characters are allowed in the Zip/Post Code field.<br />

Continue — displays the next screen and allows you to proceed to the<br />

next set of scanning options.<br />

Resolution — allows you to select the dots per inch (dpi), which<br />

determines the image quality. The options are: 300, 600 and 1200 dpi.<br />

The default is 300 dpi. In most cases, 300 dpi is sufficient. Selecting<br />

600 dpi or 1200 dpi increases scanning time and image size.<br />

Mode — select one of the following:<br />

• <strong>Photo</strong> Face Up — captures the picture side facing upward. When<br />

scanning, place the stack of photos in the feeder so the front side is<br />

facing you.<br />

• <strong>Photo</strong> Face Down — captures the picture side facing downward.<br />

When scanning, place the photo in the feeder facing away from you.<br />

• Two Sided - <strong>Photo</strong> Face Up — captures both sides of the photo.<br />

Sharpen Image — sharpens the focus and edges of the scanned<br />

image. If this option is selected, all photos within the order (the stack of<br />

photos to be scanned) will be sharpened. This option is turned off, by<br />

default. You should not need to use Sharpen Images when scanning<br />

good quality images.<br />

2-2 A-61601 July 2007


Scan Images screen When you click Continue on the Customer & Order Information screen,<br />

the Scan Images screen will be displayed.<br />

16-Up Display window — displays up to 16 images at a time.<br />

Previous — goes back to the Customer & Order Information screen.<br />

Start Over — goes back to the Customer & Order Information screen<br />

but clears all information and scanned images on the Scan Images<br />

screen. The confirmation message Do you want to start over? This<br />

will delete all the files that were scanned will be displayed.<br />

Start <strong>Scanning</strong> — scans photos.<br />

Batch Information — these values will be 0 until a batch has been<br />

scanned.<br />

• Image: displays the number of the first image shown in the 16-Up<br />

Display window.<br />

• To: displays the number of the last image shown in the 16-Up Display<br />

window.<br />

• Of: displays the total number of images scanned in the batch.<br />

Total Images: displays the total number of scanned images.<br />

Moves to the previous set of 16 images.<br />

Moves to the next set of 16 images.<br />

A-61601 July 2007 2-3


Continue Scan<br />

Images screen<br />

When you click Start <strong>Scanning</strong> on the Scan Images screen, thumbnail<br />

images will be displayed in the 16-Up Display window as they are being<br />

scanned. After the pictures are displayed you can rotate and retouch<br />

the images.<br />

16-Up Display window — displays up to 16 images at a time.<br />

Rotates the image 90 degrees counter-clockwise (left).<br />

Rotates the image 90 degrees clockwise (right).<br />

Moves to the previous set of 16 images, if any.<br />

Moves to the next set of 16 images, if any.<br />

Continue — displays the Order Preview screen.<br />

Start Over — goes back to the Customer & Order Information screen<br />

and will clear all information and scanned images. The confirmation<br />

message Do you want to start over? This will delete all the files<br />

that were scanned will be displayed.<br />

Continue <strong>Scanning</strong> — allows you to scan another batch of photos.<br />

Redo Scan Batch — replaces the last batch of scanned images.<br />

Retouch Batch — automatically retouches (e.g., color, contrast,<br />

brightness, etc.) all of the images in a batch. When this option is<br />

selected, an Image Retouch progress bar is displayed at the top of the<br />

screen.<br />

2-4 A-61601 July 2007


Enhance Picture<br />

screen<br />

Batch Information — these values will be 0 until a batch has been<br />

scanned.<br />

• Image: displays the number of the first image shown in the 16-Up<br />

Display window.<br />

• To: displays the number of the last image shown in the 16-Up Display<br />

window.<br />

• Of: displays the total number of scanned images in the batch.<br />

Total Images: displays the total number of scanned images.<br />

When you click on an image on the Scan Images screen, the image will<br />

be displayed in the Original Picture and Enhanced Picture display<br />

windows.<br />

Original Picture/Enhanced Picture — the selected photo will be<br />

displayed. The Original Picture window displays the image “as-is”.<br />

While you make changes to the displayed image, the changes will be<br />

displayed in the Enhanced Picture window. When you are finished, a<br />

message will be displayed asking if you want to save the changes.<br />

Return — goes back to the Scan Images screen.<br />

Start Over — goes back to the Customer & Order Information screen<br />

but clears all information and scanned images on the Scan Images<br />

screen. The confirmation message Do you want to start over? This<br />

will delete all the files that were scanned will be displayed.<br />

A-61601 July 2007 2-5


Enhance Picture icons<br />

Deletes the selected image.<br />

Replaces the current image with the new scanned image.<br />

Enhances the colors in the scanned image.<br />

Removes the red eye in the scanned image.<br />

Rotates the image 90 degrees to the left (counter-clockwise).<br />

Rotates the image 90 degrees to the right (clockwise).<br />

Allows you to scroll through the current batch of 16 images.<br />

Allows you to scroll through the current batch of 16 images.<br />

2-6 A-61601 July 2007


Order Preview screen This screen allows you to preview and modify your photos before<br />

completing this order.<br />

Display window — displays the folder(s) of scanned photos. You can<br />

click on a folder to view the contents.<br />

Moves to the previous set of folders.<br />

Moves to the next set of folders.<br />

Continue — displays the Order Summary and Creation screen.<br />

Start Over — goes back to the Customer & Order Information screen<br />

but clears all information and scanned images on the Scan Images<br />

screen. The confirmation message Do you want to start over? This<br />

will delete all the files that were scanned will be displayed.<br />

This Order — provides a summary of the folders displayed on this<br />

screen.<br />

A-61601 July 2007 2-7


Preview Details<br />

screen<br />

This screen allows you to preview the photos within a selected folder<br />

and enhance them if necessary.<br />

16-Up Display window — displays up to 16 images from the selected<br />

folder.<br />

Rotates the image 90 degrees counter-clockwise (left).<br />

Rotates the image 90 degrees clockwise (right).<br />

Moves to the previous set of 16 images.<br />

Moves to the next set of 16 images.<br />

Continue — displays the Order Preview screen.<br />

Start Over — goes back to the Customer & Order Information screen<br />

but clears all information and scanned images on the Scan Images<br />

screen. The confirmation message Do you want to start over? This<br />

will delete all the files that were scanned will be displayed.<br />

Retouch Folder— automatically retouches all the photos within the<br />

selected folder.<br />

This Folder — provides a summary of the current images and how<br />

many images are in this folder.<br />

2-8 A-61601 July 2007


Order Summary &<br />

Creation screen<br />

This screen allows you to finalize your order.<br />

Display window — provides the order number, customer name,<br />

address and email address. It also provides the number of photos<br />

scanned. If desired, you can change the Name, Address and Email<br />

information.<br />

Finalize order — you can either print the order summary or complete<br />

the order.<br />

• Print Order Details — if selected, allows you to print the order<br />

summary. The operating system’s Print dialog box will be displayed.<br />

You may send the order summary to the default printer, or select a<br />

different printer from the list box. After you select Print, the order<br />

summary will be sent to the printer and a message will be displayed<br />

asking if you want to start another scan session.<br />

• Print Order Details — if not selected, start another scan session or<br />

exit the application software.<br />

Previous — displays the Order Preview screen.<br />

Start Over — goes back to the Customer & Order Information screen<br />

allowing you to start a new session but clears all information and<br />

scanned images on the Scan Images screen. The confirmation<br />

message Do you want to start over? This will delete all the files<br />

that were scanned will be displayed.<br />

A-61601 July 2007 2-9


3 Using the Software<br />

The <strong>Kodak</strong> <strong>s1220</strong> <strong>Photo</strong> <strong>Scanning</strong> <strong>System</strong> allows you to scan and<br />

enhance photographs using a <strong>Kodak</strong> <strong>s1220</strong> Scanner. Once the photos<br />

are scanned, each photo is saved as a .jpg file that can be written to a<br />

CD/DVD or uploaded to the <strong>Kodak</strong> Easyshare Gallery or other photo<br />

management system for sharing and printing.<br />

Chapter 2 provides an overview of the screens and tools that you will<br />

use with the <strong>s1220</strong> <strong>Photo</strong> <strong>Scanning</strong> <strong>System</strong>.<br />

This chapter provides procedures for using the <strong>Photo</strong> <strong>Scanning</strong><br />

<strong>System</strong>.<br />

Handling guidelines Before scanning a batch of photos, review the following guidelines to<br />

save time and improve efficiency.<br />

• Handle photos with care! Be sure your hands are clean or wear<br />

clean white cotton gloves. Avoid touching the photographic surface.<br />

• Fragile or precious photos should be scanned using the <strong>Kodak</strong> A4<br />

Flatbed Accessory to eliminate the risk of damage from automated<br />

handling.<br />

• Use the scanner in a clean, dust-free environment.<br />

• Avoid unnecessary bending and flexing of photos.<br />

• Due to copyright laws, any professionally taken photos that are<br />

copyrighted cannot be scanned without written permission from the<br />

owner.<br />

• Two-sided photo scanning:<br />

- If you have a batch of photos where both sides of some photos<br />

need to be scanned, group these photos together and scan them<br />

in a separate batch. This will save time deleting unwanted blank<br />

images.<br />

- If you need to rescan a two-sided photo, always put the side you<br />

want to rescan facing down.<br />

• If you have a batch of photos that need retouching, group these<br />

photos together. When you select Retouch Batch, the application<br />

software retouches the entire batch of photos at the same time.<br />

• When you delete an image in a batch of 16, the first photo in the next<br />

batch of 16 will be placed in the batch of 16 where you deleted the<br />

image. Take the time to review the batch to be sure you do not need<br />

to do any additional enhancing.<br />

• The Sharpen Image option is not necessary for good quality photos.<br />

If you use Sharpen Image, only use it at 300 dpi or processing time<br />

will be increased.<br />

A-61601 July 2007 3-1


Starting the software<br />

and using the<br />

scanning system<br />

Before you begin, be sure the <strong>s1220</strong> Scanner is on and in the Ready<br />

state.<br />

1. Double-click on the <strong>Photo</strong> <strong>Scanning</strong> <strong>System</strong> software icon. The<br />

Customer & Order Information screen will be displayed.<br />

2. Enter up to 51 alphanumeric characters in the Order # field to<br />

identify this order. You must make an entry in this field.<br />

3. If desired, enter the last name, first name, phone, street, city, state/<br />

county/country, zip/post code and email information in the available<br />

fields.<br />

4. Select the desired resolution: 300 dpi, 600 dpi or 1200 dpi.<br />

5. Select the Mode you want to scan: <strong>Photo</strong> Face Up, <strong>Photo</strong> Face<br />

Down, or Two Sided - <strong>Photo</strong> Face Up.<br />

NOTES:<br />

• If you are using an optional <strong>Kodak</strong> A4 Flatbed, you must select<br />

<strong>Photo</strong> Face Down or Two Sided - <strong>Photo</strong> Face Up.<br />

• If you are using the flatbed, be sure there are no photos in the<br />

input tray of the scanner, otherwise the photos that are in the<br />

input tray will be scanned instead of the photo on the flatbed.<br />

Refer to the documentation included with the <strong>Kodak</strong> A4 Flatbed<br />

Accessory for setup instructions.<br />

6. If you want to use the Sharpen Images option, click the checkbox.<br />

This option is not intended to be used with good quality photos.<br />

NOTE: Only use this option at 300 dpi. Using higher dpi settings<br />

increases processing time.<br />

3-2 A-61601 July 2007


7. Select Continue. The Scan Images screen will be displayed.<br />

8. Place the first batch of photos in the scanner. The feeder can<br />

accommodate up to 30 photos at a time. Depending on your<br />

selection in Step 5, be sure the side you want to scan is facing<br />

properly.<br />

NOTES:<br />

• For best feeding performance always scan the photos with the<br />

scanner body tilted back to the 25-degree angle and with photos<br />

face up as shown in the illustration below. For more information<br />

see the section entitled “Scanner positions” in the User’s <strong>Guide</strong><br />

for the <strong>Kodak</strong> i1200/i1300 Series Scanners, A-61560.<br />

• The scanner scans photos from the bottom of the stack first.<br />

Therefore, if you want your photos scanned in a specific order,<br />

stack your photos with the first photo being closet to the input<br />

tray.<br />

9. Click Start <strong>Scanning</strong>. The message, Scanner lamps are<br />

warming, may be displayed. <strong>Scanning</strong> will start when the lamps are<br />

ready (usually within a few seconds).<br />

A-61601 July 2007 3-3


As photos are being scanned, the scanned images will be displayed<br />

in the 16-Up Display window.<br />

10.When a batch of photos has been scanned, retouch and/or rotate<br />

the photos as desired. If you do not need to make any changes and<br />

are finished scanning all photos in this order, click Continue.<br />

11. If you want to scan more photos, make enhancements, etc. these<br />

options are available:<br />

• If you want to scan another batch of photos in this order, place<br />

more photos in the feeder and click Continue <strong>Scanning</strong>. The<br />

photos will be scanned. When you are finished scanning all the<br />

photos in the order, go to Step 12.<br />

• Use the rotate arrows on each displayed image to rotate as<br />

desired. Make any other desired changes then go to Step 12.<br />

• If you want to retouch all of the photos in the scanned batch, click<br />

Retouch Batch. All the images in the batch will be retouched.<br />

Make any other desired changes then go to Step 12.<br />

• If you want to rescan all of the photos in the scanned batch, click<br />

Redo Scan Batch. The 16-Up Display window will be cleared,<br />

and the rescanned photos will be displayed on the screen. Make<br />

any other desired changes then go to Step 12.<br />

3-4 A-61601 July 2007


• If you want to use any special enhancement features, e.g.,<br />

correct red eye, delete an image, retouch a specific image, etc.),<br />

click on the image you want to enhance. The Enhanced Picture<br />

screen will be displayed. Make any other desired changes then<br />

go to Step 12.<br />

12.When finished making changes and scanning, click Continue. The<br />

following message will be displayed.<br />

A-61601 July 2007 3-5


13.Click Yes. The Order Preview screen will be displayed.<br />

14.Select the folder that you want to preview and click Continue.<br />

The Preview Details screen will be displayed.<br />

15.From the Preview Details screen you can make any final changes.<br />

When finished, click Continue.<br />

3-6 A-61601 July 2007


The Order Preview screen will be displayed.<br />

16.If you want to review the contents of the folder one more time before<br />

finishing your order, select the desired folder, otherwise, click<br />

Continue.<br />

The Order Summary & Creation screen will be displayed.<br />

17.Verify that all the information in the order summary is complete and<br />

click Finalize Order.<br />

A-61601 July 2007 3-7


If you want to print the order summary, check the Print Order<br />

Details check box. When you click Finalize Order, the Print dialog<br />

box will be displayed allowing you to print the order summary.<br />

The following message will be displayed.<br />

18.If you want to start a new scan session, click Yes. Otherwise, click<br />

No to close the <strong>Kodak</strong> <strong>Photo</strong> <strong>Scanning</strong> Software.<br />

Unless you changed the default at installation, scanned images can be<br />

found at C:\Scanned_Pictures. These images can now be handled in<br />

a variety of ways: uploaded to a photo management system, burned to<br />

CD/DVD, printed, emailed, etc. A .xml file will also be created with the<br />

print order summary. The .xml file can be found within the print order<br />

directory.<br />

3-8 A-61601 July 2007


4 Troubleshooting<br />

Use the Error Code list on the next page as a guide to check possible<br />

solutions to problems you may encounter when using the <strong>Kodak</strong> <strong>s1220</strong><br />

<strong>Photo</strong> <strong>Scanning</strong> <strong>System</strong>.<br />

Installation Issues<br />

• Unless you changed the default at installation, scanned images can<br />

be found at C:\Scanned_Pictures. These images can now be<br />

handled in a variety of ways: uploaded to a photo management<br />

system, burned to CD/DVD, printed, emailed, etc. A .xml file will also<br />

be created with the print order summary. The .xml file can be found<br />

within the print order directory.<br />

• The <strong>s1220</strong> <strong>Photo</strong> <strong>Scanning</strong> <strong>System</strong> uses Microsoft .NET Framework<br />

2.0. If .Net Framework 2.0 is not installed on the PC, it will be<br />

installed during installation.<br />

• If a security software application is installed on the PC, you will be<br />

asked to Allow or Deny the <strong>s1220</strong> <strong>Photo</strong> <strong>Scanning</strong> <strong>System</strong> from<br />

installing or running, select Allow or Yes. If you inadvertently select<br />

Deny or No, open the security software application and set the<br />

permission to Allow the application to install and run.<br />

• Close any currently running applications that use a WIBU security<br />

key before starting the <strong>s1220</strong> <strong>Photo</strong> <strong>Scanning</strong> <strong>System</strong> installation.<br />

• The WIBU key should be plugged into a USB 2.0 port directly on the<br />

PC, not into a USB hub that is then plugged into a PC USB port.<br />

Plugging a USB 2.0 hub into a USB 1.1 port can cause the WIBU<br />

software to not load automatically (see the next issue).<br />

• If after installation of the application and plug-in of the WIBU key, the<br />

WIBU software does not automatically load, a message may be<br />

displayed asking for the WIBU installation disk. Select that you have<br />

the software disk and choose the CD drive with the <strong>s1220</strong> <strong>Photo</strong><br />

<strong>Scanning</strong> <strong>System</strong> installation CD. This will complete the WIBU<br />

software installation.<br />

A-61601 July 2007 4-1


Application issues<br />

• The <strong>Kodak</strong> <strong>s1220</strong> <strong>Photo</strong> <strong>Scanning</strong> <strong>System</strong> has a fixed screen size of<br />

1024 x 768. You may want to change the taskbar properties by<br />

unselecting "Keep the taskbar on top of other windows." This will<br />

keep the taskbar from covering the lower portion of the application<br />

when the screen resolution is set at 1024 x 768. You can also<br />

alternatively set the display properties to a higher screen resolution<br />

than 1024 x 768, such as 1280 x 960 so the application does not<br />

cover the entire desktop.<br />

• If the scanner encounters E9 Document Jams when scanning at<br />

higher resolutions (600 or 1200 dpi) and the PCs RAM is less than<br />

3GB, then the memory should be increased to the required 3GB<br />

RAM for high resolution scanning.<br />

Application Configuration<br />

• The <strong>s1220</strong> <strong>Photo</strong> <strong>Scanning</strong> <strong>System</strong> may be configured by modifying<br />

the PrintScan.ini file in the <strong>s1220</strong> <strong>Photo</strong> <strong>Scanning</strong> <strong>System</strong> installation<br />

directory. You can change the location for the output JPG files<br />

(Target_Path) and adjust the number of pictures in a folder for<br />

burning CDs or DVDs (NoFilesInFolder). The default values for<br />

SharpenIntensity, Contrast, JPGChromeFactor, JPGLumFactor, and<br />

JPGSubSampling are preset to optimal values and generally do not<br />

need to be modified.<br />

4-2 A-61601 July 2007


Error code listing Following are some error codes that you may encounter when using the<br />

<strong>Kodak</strong> <strong>s1220</strong> <strong>Photo</strong> <strong>Scanning</strong> <strong>System</strong>.<br />

Error Code Message Description<br />

251085:<br />

1220<br />

Access to destination folder XXXX could not<br />

be set exiting the application.<br />

Start error. <strong>Kodak</strong> <strong>s1220</strong> <strong>Photo</strong> <strong>Scanning</strong><br />

<strong>System</strong> copy protection error. No license<br />

found.<br />

6017 Please check if the correct WIBU USB<br />

license dongle has been inserted in your<br />

PCs USB port. If this error persists, please<br />

contact support with error code 6017.<br />

6XXX Please check if the correct WIBU USB<br />

License dongle has been inserted into your<br />

PCs USB port. If this error persists, please<br />

contact support with error code 6XXX.<br />

7000 Please check if WIBU runtime has been<br />

installed. WIBU runtime (WkRuntime.exe)<br />

can be found on the CD provided with the<br />

<strong>Kodak</strong> scanner.<br />

7001 License .dat file not found. Please contact<br />

support with error code 7001.<br />

8001 Profile error. Please verify that STW default<br />

profile settings have not been altered. If this<br />

error persists, please contact support with<br />

error code 8001.<br />

8002 Scanner name not found. Please verify that<br />

STW default profile settings have not been<br />

altered. If this error persists, please contact<br />

support with error code 8002.<br />

9001, 9002,<br />

9003<br />

TWAIN drivers could not be instantiated.<br />

Please retry. If this error persists, please<br />

contact support with error code 900X.<br />

Verify that there is a valid Target_Path for the scanned<br />

photos in the PrintScan.ini file.<br />

Verify that the supplied <strong>s1220</strong> WIBU key is plugged into<br />

a USB 2.0 port on the PC.<br />

Verify that the supplied <strong>s1220</strong> WIBU key is plugged into<br />

a USB 2.0 port on the PC.<br />

Verify that the supplied <strong>s1220</strong> WIBU key is plugged into<br />

a USB 2.0 port on the PC.<br />

Contact <strong>Kodak</strong> Service.<br />

Contact <strong>Kodak</strong> Service.<br />

Reinstall the <strong>Kodak</strong> <strong>s1220</strong> <strong>Photo</strong> <strong>Scanning</strong> <strong>System</strong>.<br />

Refer to the section entitled, “Installing the software” in<br />

Chapter 1.<br />

Reinstall the <strong>Kodak</strong> <strong>s1220</strong> <strong>Photo</strong> <strong>Scanning</strong> <strong>System</strong>.<br />

Refer to the section entitled, “Installing the software” in<br />

Chapter 1.<br />

Reinstall the <strong>Kodak</strong> <strong>s1220</strong> <strong>Photo</strong> <strong>Scanning</strong> <strong>System</strong>.<br />

Refer to the section entitled, “Installing the software” in<br />

Chapter 1.<br />

9004 Could not find a <strong>Kodak</strong> scanner. Be sure that a <strong>Kodak</strong> scanner is attached, turned on and<br />

the green LED is on and steady. If the error persists,<br />

contact <strong>Kodak</strong> Service.<br />

9005 Please check if scanner is available to STW. Verify that the <strong>s1220</strong> Scanner is connected and<br />

powered on. If this error persists, contact <strong>Kodak</strong><br />

Service.<br />

A-61601 July 2007 4-3


Error Code Message Description<br />

9006, 9007,<br />

9008, 9010<br />

Could not instantiate the scanner. Please<br />

retry. If this error persists, please contact<br />

support with error code 900X.<br />

9009 Could not get the image from the scanner.<br />

Please retry. If this error persists, please<br />

contact support with error code 9009.<br />

Reinstall the <strong>Kodak</strong> <strong>s1220</strong> <strong>Photo</strong> <strong>Scanning</strong> <strong>System</strong>.<br />

Refer to the section entitled, “Installing the software” in<br />

Chapter 1.<br />

Contact <strong>Kodak</strong> Service.<br />

<strong>s1220</strong> Scanner specific errors.<br />

For more information see the User’s <strong>Guide</strong> for the <strong>Kodak</strong> i1200/i1300 Series Scanners.<br />

E0 USB cable is not connected Connect the USB cable to the PC and scanner.<br />

E6 Cover open Be sure the scanner cover is securely closed and begin<br />

scanning.<br />

E9 Document jam A document is lodged in the scanner. Clear the paper<br />

path by opening the scanner cover, removing the lodged<br />

document and closing the scanner cover.<br />

Problem solving Use the chart below as a guide to check possible solutions to problems<br />

you may encounter when using the <strong>Kodak</strong> <strong>s1220</strong> <strong>Photo</strong> <strong>Scanning</strong><br />

<strong>System</strong>.<br />

Problem Possible Solution<br />

Application display<br />

windows and screens are<br />

distorted<br />

Check the font size settings in the Display<br />

Properties. The settings should be set to Normal<br />

96 dpi with 32-bit color.<br />

Getting service If your scanner needs service, go to the website at:<br />

www.kodak.com/go/docimaging<br />

There you can find out how best to obtain service for your scanner for<br />

your region.<br />

4-4 A-61601 July 2007


Eastman <strong>Kodak</strong> Company<br />

343 State Street<br />

Rochester, NY 14650 U.S.A.<br />

© <strong>Kodak</strong>, 2007. All rights reserved.<br />

TM: <strong>Kodak</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!