4 Final Report - Emits - ESA
4 Final Report - Emits - ESA
4 Final Report - Emits - ESA
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
4 <strong>Final</strong><br />
<strong>Report</strong><br />
Microbolometers measure changes of electrical resistances with the help of pulsed currents. The<br />
major advantages are the possibility to operate at room temperature and the monolithic silicon<br />
structure which allows cheap production. Microbolometers are sensitive between 7 and 14 µm, but the<br />
responsivity is much lower than for quantum detectors. Microbolometers are not retained in the<br />
baseline for Fire Monitoring because the performances and the maturity level for GEO applications<br />
needs to be consolidated.<br />
The TIR detector architecture is similar to the MWIR one, but simpler thanks to the reduced number of<br />
pixels: two 400x800 pixels sub-arrays read out via 2 10 Mpixels/s video outputs, so the read out period<br />
is 16 ms, much larger than the max. integration time (