4 Final Report - Emits - ESA
4 Final Report - Emits - ESA
4 Final Report - Emits - ESA
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
4 <strong>Final</strong><br />
<strong>Report</strong><br />
board image processing. Column 7 gives the number of images requiring post-integration with LoS<br />
motion compensation. For instance, channel VNIR1 requires an accumulation of 18 images (column 6)<br />
with image motion compensation between 6 packets (column 7) of 3 simply accumulated images.<br />
Channel UV1 requires post-integration with motion compensation of 30 successive images (same<br />
value in columns 6 & 7).<br />
1 2 3 4 5 6 7 8 9<br />
Mission Channel<br />
GSD at 52°N<br />
(m)<br />
MTF at<br />
Nyquist<br />
<strong>Final</strong><br />
SNR<br />
Nb<br />
of images<br />
Post<br />
Integration<br />
Integ. Time<br />
of image (s)<br />
Channel acq.<br />
time (s)<br />
Marine UV1 80 0.156 1000 30 30 0.082 2.637<br />
Marine UV2 80 0.162 1000 10 10 0.083 0.879<br />
Marine VNIR1 80 0.146 1500 18 6 0.035 1.582<br />
Marine VNIR2 80 0.161 1300 15 5 0.031 1.318<br />
Marine VNIR3 80 0.154 943 6 3 0.050 0.527<br />
Marine VNIR4 80 0.175 748 6 3 0.041 0.527<br />
Marine VNIR5 80 0.171 557 2 2 0.085 0.176<br />
Marine VNIR6 80 0.144 418 2 No 0.059 0.176<br />
Marine VNIR8b 80 0.159 376 1 No 0.105 0.105<br />
Marine VNIR9 80 0.140 339 1 No 0.118 0.118<br />
Marine VNIR10 80 0.165 323 1 No 0.098 0.098<br />
Marine VNIR11 80 0.216 478 2 No 0.019 0.176<br />
Marine VNIR12 80 0.186 258 1 No 0.073 0.088<br />
Marine VNIR13b 80 0.193 213 1 No 0.051 0.088<br />
Marine VNIR14 80 0.137 213 1 No 0.108 0.108<br />
Marine VNIR15 80 0.201 259 1 No 0.023 0.088<br />
Marine VNIR16 80 0.164 250 1 No 0.055 0.088<br />
Marine SWIR 300 0.271 250 1 No 4.19E-04 0.025<br />
Marine MWIRb 300 0.095 378 1 No 0.017 0.025<br />
Marine TIR1b 750 0.097 1818 1 No 5.64E-04 0.016<br />
Marine TIR2b 750 0.102 2001 1 No 5.46E-04 0.016<br />
Figure 4.3-3: Performances for Marine applications<br />
4.3.2.3 Fire Monitoring<br />
Fire monitoring is based on three IR channels, a MWIR channel with 300 m resolution to monitor the<br />
fire area & location and two TIR channels with 750 m resolution to measure fire temperature.<br />
Two VNIR channels with moderate SNR are also required, for which 40m resolution is possible without<br />
post-integration if VNIR13a SNR requirement is relaxed from 213 (user requirement) to 150. This<br />
value is assumed to simplify the image acquisition scheme.<br />
1 2 3 4 5 6 7 8 9<br />
Mission Channel<br />
GSD at 52°N<br />
(m)<br />
MTF at<br />
Nyquist<br />
<strong>Final</strong><br />
SNR<br />
Nb<br />
of images<br />
Post<br />
Integration<br />
Integ. Time<br />
of image (s)<br />
Channel acq.<br />
time (s)<br />
Fire VNIR8a 40 0.112 80 1 No 0.017 0.088<br />
Fire VNIR13a 40 0.103 150 1 No 0.062 0.088<br />
Fire MWIRa 300 0.095 233 1 No 2.62E-05 0.025<br />
Fire TIR1a 750 0.097 670 1 No 4.72E-05 0.016<br />
Fire TIR2a 750 0.102 736 1 No 5.05E-05 0.016<br />
Figure 4.3-4: Performances for Fire Monitoring<br />
Page 4-32 Doc. No: GOC-ASG-RP-002<br />
Issue: 2<br />
Astrium GmbH Date: 13.05.2009