board image processing. Column 7 gives the number of images requiring post-integration with LoS<br />

motion compensation. For instance, channel VNIR1 requires an accumulation of 18 images (column 6)<br />

with image motion compensation between 6 packets (column 7) of 3 simply accumulated images.<br />

Channel UV1 requires post-integration with motion compensation of 30 successive images (same<br />

value in columns 6 & 7).<br />

1 2 3 4 5 6 7 8 9<br />

Mission Channel<br />

GSD at 52°N<br />

(m)<br />

MTF at<br />

Nyquist<br />

<strong>Final</strong><br />

SNR<br />

Nb<br />

of images<br />

Post<br />

Integration<br />

Integ. Time<br />

of image (s)<br />

Channel acq.<br />

time (s)<br />

Marine UV1 80 0.156 1000 30 30 0.082 2.637<br />

Marine UV2 80 0.162 1000 10 10 0.083 0.879<br />

Marine VNIR1 80 0.146 1500 18 6 0.035 1.582<br />

Marine VNIR2 80 0.161 1300 15 5 0.031 1.318<br />

Marine VNIR3 80 0.154 943 6 3 0.050 0.527<br />

Marine VNIR4 80 0.175 748 6 3 0.041 0.527<br />

Marine VNIR5 80 0.171 557 2 2 0.085 0.176<br />

Marine VNIR6 80 0.144 418 2 No 0.059 0.176<br />

Marine VNIR8b 80 0.159 376 1 No 0.105 0.105<br />

Marine VNIR9 80 0.140 339 1 No 0.118 0.118<br />

Marine VNIR10 80 0.165 323 1 No 0.098 0.098<br />

Marine VNIR11 80 0.216 478 2 No 0.019 0.176<br />

Marine VNIR12 80 0.186 258 1 No 0.073 0.088<br />

Marine VNIR13b 80 0.193 213 1 No 0.051 0.088<br />

Marine VNIR14 80 0.137 213 1 No 0.108 0.108<br />

Marine VNIR15 80 0.201 259 1 No 0.023 0.088<br />

Marine VNIR16 80 0.164 250 1 No 0.055 0.088<br />

Marine SWIR 300 0.271 250 1 No 4.19E-04 0.025<br />

Marine MWIRb 300 0.095 378 1 No 0.017 0.025<br />

Marine TIR1b 750 0.097 1818 1 No 5.64E-04 0.016<br />

Marine TIR2b 750 0.102 2001 1 No 5.46E-04 0.016<br />

Figure 4.3-3: Performances for Marine applications<br />

4.3.2.3 Fire Monitoring<br />

Fire monitoring is based on three IR channels, a MWIR channel with 300 m resolution to monitor the<br />

fire area & location and two TIR channels with 750 m resolution to measure fire temperature.<br />

Two VNIR channels with moderate SNR are also required, for which 40m resolution is possible without<br />

post-integration if VNIR13a SNR requirement is relaxed from 213 (user requirement) to 150. This<br />

value is assumed to simplify the image acquisition scheme.<br />

1 2 3 4 5 6 7 8 9<br />

Mission Channel<br />

GSD at 52°N<br />

(m)<br />

MTF at<br />

Nyquist<br />

<strong>Final</strong><br />

SNR<br />

Nb<br />

of images<br />

Post<br />

Integration<br />

Integ. Time<br />

of image (s)<br />

Channel acq.<br />

time (s)<br />

Fire VNIR8a 40 0.112 80 1 No 0.017 0.088<br />

Fire VNIR13a 40 0.103 150 1 No 0.062 0.088<br />

Fire MWIRa 300 0.095 233 1 No 2.62E-05 0.025<br />

Fire TIR1a 750 0.097 670 1 No 4.72E-05 0.016<br />

Fire TIR2a 750 0.102 736 1 No 5.05E-05 0.016<br />

Figure 4.3-4: Performances for Fire Monitoring<br />

Page 4-32 Doc. No: GOC-ASG-RP-002<br />

Issue: 2<br />

Astrium GmbH Date: 13.05.2009