Commissioning<br />

In the graph below, the curves have been divided into<br />

two groups:<br />

– Low-temperature systems<br />

– High temperature systems<br />

The two groups are divided according to the different<br />

point of origin of the curves, which for high-temperature<br />

systems is higher than 10°C, a correction usually made to<br />

the delivery temperature in these types of systems during<br />

climatic adjustment.<br />

4.2.4 Room Influence Proportional<br />

Turn the selector and set the most suitable value, then press<br />

the selector to confirm. The influence of the room sensor<br />

can be adjusted to a value between 20 (maximum influence)<br />

and 0 (no influence). In this way, the contribution of the room<br />

temperature to the delivery temperature calculation can be<br />

adjusted.<br />

4.2.5 Max T<br />

Turn the selector<br />

press the selector<br />

4.2.6 Min T<br />

Turn the selector<br />

press the selector<br />

then set the most suitable value and<br />

to confirm.<br />

then set the most suitable value and<br />

to confirm.<br />

4.2.7 Thermoregulation logic<br />

Turn the selector then set the most suitable value and<br />

press the selector to confirm.<br />

Turn the selector and select:<br />

0 Classic.<br />

1 Smart Smart temperature control (in this mode, the water<br />

flow set-point is calculated using the information provided<br />

in parameter 4.7 Zone regulation parameters)<br />

4.2.8 Quick night setback<br />

Turn the selector then set the most suitable value and<br />

press the selector to confirm.<br />

Turn the selector and select:<br />

0 OFF.<br />

1 ON.<br />

4.2.9 Heat request mode<br />

Turn the selector then set the most suitable value and<br />

press the selector to confirm.<br />

Turn the selector and select:<br />

0 Standard.<br />

1 RT Time Programs Exclusion (In this mode, the heat requests<br />

generated by the RT remain active also during the<br />

night-time period in programmed mode).<br />

2 Forcing Heat Demand (The activation of this function generates<br />

a constantly active heat request).<br />

Repeat the steps described previously to set the values for zone<br />

2 (where present), by selecting the 5 Zone 2 parameters menu.<br />

NOTE:<br />

For correct operation of the temperature adjustment types: 2.<br />

Room sensor only: 3. Outdoor sensor only: 4. Room sensor plus<br />

external sensor, parameter 1.0.6 Thermoregulation should be<br />

set to value 1, or the AUTO function must be activated.<br />

4.3 DIAGNOSTICS<br />

4.4 ZONE MODULE SETTINGS<br />

4.4.0 Zone pump modulation<br />

Press the selector . Turn the selector to choose the desired<br />

item.<br />

0 Fixed.<br />

1 Modulating on DeltaT.<br />

2 Modulating on pressure.<br />

Press the selector to confirm.<br />

4.4.1 Delta T pump setpoint<br />

4.4.2 Pump fixed speed<br />

4.5 COOL<br />

4.5.0 T Set Cool<br />

Press the selector . Turn the selector and set the delivery setpoint<br />

temperature value, if temperature control is deactivated<br />

or with fixed point.<br />

4.5.1 Cooling Temp Range<br />

Press the OK button. Turn the selector and select the temperature<br />

range:<br />

0 Fan Coil.<br />

1 Underfloor.<br />

4.5.2 Thermoregulation<br />

Press the selector , turn the selector and set the type of temperature<br />

control installed:<br />

0 ON/OFF Thermostat (Fixed water flow set-point specified<br />

in Par. 4.5.0 T Set Cool).<br />

1 Fix Flow T (Fixed water flow set-point specified in Par. 4.5.0<br />

T Set Cool).<br />

2 Outdoor T Only (Water flow set-point according to the outdoor<br />

temperature).<br />

4.5.3 Slope<br />

Press the selector . Turn the selector and set the curve on<br />

the basis of the type of cooling system.<br />

Press the selector to confirm.<br />

– Fan coil units (curve from 18 to 33).<br />

– Underfloor heating system (curve from 0 to 60).<br />

EN / 59