Commissioning<br />

4 Curing Heating + Functional Heating (screed heating at<br />

a variable temperature from 25°C to the temperature defined<br />

by Par. 1.12.6 Floor drying Flow Set Point T, according<br />

to the period specified as an example in the chart for an<br />

18-day period, then at a fixed temperature of 25°C for a period<br />

of 3 days, then for a further 4 days at the temperature<br />

defined by Par. 1.12.6 Floor drying Flow Set Point T)<br />

1.17 EM DIAGNOSTICS - 2 INPUT<br />

1.18 EM DIAGNOSTICS - 1 OUTPUT<br />

Displays the values of the system’s board outputs.<br />

1.19 SERVICE<br />

1.19.0 SW Version main<br />

Temperature °C<br />

60<br />

50<br />

40<br />

30<br />

20<br />

10<br />

0<br />

0 5 10 15 20 25 30<br />

Period (days)<br />

Fig. 89<br />

5 <strong>Manual</strong> (screed heating at the temperature set in Par.<br />

1.12.6 Floor drying Flow Set Point T)<br />

Press the selector to confirm.<br />

1.20 SYSTEM INTEGRATION<br />

1.20.0 PV offset DHW setpoint temperature<br />

Press the selector . Rotate the selector to set the desired<br />

value to increase the DHW set-point during integration from<br />

the photovoltaic system.<br />

Press the selector to confirm.<br />

1.20.2 Tank solar integration<br />

Activates integration of the solar heating system. In this case,<br />

the high sensor of the solar heating tank is used as a DHW tank<br />

sensor.<br />

Press the selector . Turn the selector to choose the desired<br />

item.<br />

0 Absent.<br />

1 Present.<br />

Press the selector to confirm.<br />

1.12.6 Floor drying Flow Set Point T<br />

Defines the set-point temperature of the heating delivery during<br />

the screed drying function (see Par. 1.12.5 Floor drying cycle).<br />

1.12.7 Floor drying total Remaining Days<br />

Defines the days remaining for the screed drying function.<br />

1.12.9 Exogel kit activation<br />

Enables integration of the anti-freeze kit.<br />

Press the selector . Turn the selector to choose the desired<br />

item.<br />

0 OFF.<br />

1 ON.<br />

Press the selector to confirm.<br />

1.14 ENERGY MANAGER STATISTICS<br />

Shows the duration of the system operation in hours.<br />

1.16 EM DIAGNOSTICS - 1 INPUT<br />

Displays the values of the system’s board inputs.<br />

1.20.3 OpenTherm gateway activation<br />

Activates the Opentherm gateway.<br />

Press the selector . Turn the selector to choose the desired<br />

item.<br />

0 OFF.<br />

1 ON.<br />

Press the selector to confirm.<br />

1.21 ERROR HISTORY<br />

1.21.0 Last 10 errors<br />

Displays the last 10 errors.<br />

1.21.1 Reset error list<br />

Press the selector . Turn the selector to choose the desired<br />

item.<br />

0 Do you really want to perform the reset ? If you press OK<br />

button, the reset command will be executed otherwise, by<br />

way of ESC, the previous page is shown..<br />

Press the selector to confirm.<br />

1.22 RESET MENU<br />

1.22.0 Reset factory settings<br />

Restores the default settings.<br />

Press the selector . Turn the selector to choose the desired<br />

item.<br />

0 Do you really want to perform the reset ? If you press OK<br />

button, the reset command will be executed otherwise, by<br />

way of ESC, the previous page is shown..<br />

Press the selector to confirm.<br />