The ST1 connection is bridged by default. Do not<br />

remove the jumper.<br />

If the installation involves the use of thermostats<br />

or timer-controlled thermostats to manage the<br />

heat request, it is necessary to ensure that they<br />

do not have a proportional-band control logic.<br />

This logic may indeed cause inefficient behaviour<br />

of the system and fail to guarantee the fulfilment<br />

of the room temperature set-point. We recommend<br />

using modulating thermostats, modulating<br />

timer-controlled thermostats or ON/OFF thermostats<br />

without proportional band logic.<br />

Electrical connections<br />

– Fasten the power cable (2) to the terminal board (M1).<br />

– Fasten the communication cable (3) between the outdoor<br />

and indoor units to the terminal board (M2).<br />

– To ensure adequate resistance to pulling, the power cables<br />

must be secured using the cable clamps (4).<br />

M2<br />

M1<br />

4<br />

3<br />

4<br />

2<br />

Fig. 55<br />

36 / EN