The ST1 connection is bridged by default. Do not<br />
remove the jumper.<br />
If the installation involves the use of thermostats<br />
or timer-controlled thermostats to manage the<br />
heat request, it is necessary to ensure that they<br />
do not have a proportional-band control logic.<br />
This logic may indeed cause inefficient behaviour<br />
of the system and fail to guarantee the fulfilment<br />
of the room temperature set-point. We recommend<br />
using modulating thermostats, modulating<br />
timer-controlled thermostats or ON/OFF thermostats<br />
without proportional band logic.<br />
Electrical connections<br />
– Fasten the power cable (2) to the terminal board (M1).<br />
– Fasten the communication cable (3) between the outdoor<br />
and indoor units to the terminal board (M2).<br />
– To ensure adequate resistance to pulling, the power cables<br />
must be secured using the cable clamps (4).<br />
M2<br />
M1<br />
4<br />
3<br />
4<br />
2<br />
Fig. 55<br />