Electrical connections<br />
5. Electrical connections<br />
a<br />
a<br />
Carry out the electrical connections after having<br />
completed all the hydraulic connections.<br />
After the outdoor unit is switched off, it is necessary<br />
to wait at least 5 minutes to switch it on<br />
again.<br />
The indoor and outdoor units must be powered separately by<br />
observing the indications of the table.<br />
Moreover, a ATG BUS-type connection must be made between<br />
the indoor and outdoor units.<br />
This connection can be made using a cable with reduced<br />
cross-sectional size (0.75 mm 2 recommended cross-sectional<br />
size).<br />
Electrical circuit<br />
– The electrical system must satisfy all the requirements<br />
of the law in force.<br />
– Check that the mains power supply voltage and frequency<br />
are in line with the data indicated on the system’s<br />
data plate (see table).<br />
– For greater safety, ask a qualified technician to perform<br />
a thorough check of the electrical system.<br />
– We recommend verifying the presence of surge protection<br />
devices (SPDs) on the power supply line, in order to<br />
comply with the IEC 60364 standard and the national<br />
standards in force, and the presence of safety switches<br />
and residual-current circuit breakers in the electrical<br />
panels that power the indoor and outdoor units separately.<br />
– For the machine’s power supply we recommend using<br />
properly sized disconnection devices in compliance<br />
with the applicable regulations.<br />
– The power supply connection is a type-Y system and<br />
the connection cable should only be replaced by a<br />
qualified technical support centre, in order to avoid any<br />
damages.<br />
– Check that the electrical installation is adequate for supporting<br />
the power consumption of the installed units,<br />
as indicated on the appliances’ data plate.<br />
– The electrical connections must be made with the help<br />
of a fixed support (do not use portable socket-outlets)<br />
and fitted with a double pole switch, with a contact gap<br />
of at least 3 mm.<br />
– The system must be connected to an electrical system<br />
with an earthing device capable of ensuring the safety<br />
of the installation.<br />
– It is forbidden to use hydraulic connection pipes and<br />
pipes of the space heating system to earth the system.<br />
– The manufacturer is not liable for any damage caused<br />
by a system with inadequate earthing or electrical system<br />
anomalies.<br />
– Connect the power supply cable to a 230 V- 50 Hz (1<br />
ph) or 400 V - 50 Hz (3 ph) network, while verifying<br />
that the pole markings match and the connections to<br />
earth (see table).<br />
EN / 33