Electrical connections<br />

5. Electrical connections<br />

a<br />

a<br />

Carry out the electrical connections after having<br />

completed all the hydraulic connections.<br />

After the outdoor unit is switched off, it is necessary<br />

to wait at least 5 minutes to switch it on<br />

again.<br />

The indoor and outdoor units must be powered separately by<br />

observing the indications of the table.<br />

Moreover, a ATG BUS-type connection must be made between<br />

the indoor and outdoor units.<br />

This connection can be made using a cable with reduced<br />

cross-sectional size (0.75 mm 2 recommended cross-sectional<br />

size).<br />

Electrical circuit<br />

– The electrical system must satisfy all the requirements<br />

of the law in force.<br />

– Check that the mains power supply voltage and frequency<br />

are in line with the data indicated on the system’s<br />

data plate (see table).<br />

– For greater safety, ask a qualified technician to perform<br />

a thorough check of the electrical system.<br />

– We recommend verifying the presence of surge protection<br />

devices (SPDs) on the power supply line, in order to<br />

comply with the IEC 60364 standard and the national<br />

standards in force, and the presence of safety switches<br />

and residual-current circuit breakers in the electrical<br />

panels that power the indoor and outdoor units separately.<br />

– For the machine’s power supply we recommend using<br />

properly sized disconnection devices in compliance<br />

with the applicable regulations.<br />

– The power supply connection is a type-Y system and<br />

the connection cable should only be replaced by a<br />

qualified technical support centre, in order to avoid any<br />

damages.<br />

– Check that the electrical installation is adequate for supporting<br />

the power consumption of the installed units,<br />

as indicated on the appliances’ data plate.<br />

– The electrical connections must be made with the help<br />

of a fixed support (do not use portable socket-outlets)<br />

and fitted with a double pole switch, with a contact gap<br />

of at least 3 mm.<br />

– The system must be connected to an electrical system<br />

with an earthing device capable of ensuring the safety<br />

of the installation.<br />

– It is forbidden to use hydraulic connection pipes and<br />

pipes of the space heating system to earth the system.<br />

– The manufacturer is not liable for any damage caused<br />

by a system with inadequate earthing or electrical system<br />

anomalies.<br />

– Connect the power supply cable to a 230 V- 50 Hz (1<br />

ph) or 400 V - 50 Hz (3 ph) network, while verifying<br />

that the pole markings match and the connections to<br />

earth (see table).<br />

EN / 33