Hydraulic connections<br />

Key<br />

Symbol<br />

Description<br />

System flow<br />

Symbol<br />

Description<br />

Hydraulic circuit-breaker<br />

Symbol<br />

Description<br />

CUBE<br />

System return<br />

Communication connection<br />

Electrical connection<br />

Domestic cold water inlet<br />

Domestic hot water outlet<br />

Buffer<br />

Storage active<br />

Timer-controlled thermostat<br />

Lightbox<br />

Zone manager<br />

Refrigerant circuit<br />

Gas supply<br />

Circulation pump<br />

Shutter valve<br />

DHW expansion vessel<br />

System expansion vessel<br />

NTC<br />

RF<br />

2-zone wired control<br />

module<br />

2-zone wireless control<br />

module<br />

AB<br />

B<br />

A<br />

Diverter valve<br />

DHW 3-way mixing valve<br />

System 3-way mixing<br />

valve<br />

Safety valve<br />

Differential bypass valve<br />

Non-return valve<br />

Sludge filter<br />

Y-shaped filter<br />

Discharge outlet<br />

Syphon<br />

Plate heat exchanger<br />

Manifold<br />

Low-temperature heating<br />

zone<br />

Radiator<br />

Fan coil unit<br />

Dehumidifier<br />

External probe<br />

RF external sensor<br />

Gateway<br />

Sensys <strong>NET</strong> HD<br />

CUBE S <strong>NET</strong><br />

RF receiver<br />

Heating only<br />

Cooling only<br />

Heating / Cooling<br />

Living room<br />

Sleeping area<br />

Delivery temperature<br />

sensor<br />

Return temperature<br />

sensor<br />

Anti-freeze kit<br />

Kit barrette<br />

CKZ puffer kit<br />

Thundish<br />

Hydraulic Kit<br />

CUBE RF<br />

Y-shaped filter kit<br />

Space heating supplementary<br />

heating element<br />

kit<br />

NOTE: installations with under-floor system<br />

In installations with under-floor heating, make sure that in all<br />

operating modes (the hot water switching mode in particular),<br />

the input temperature of the floor falls within the limits allowed<br />

for the application as specified in the national regulations.<br />

For installations with under-floor system, install a safety device<br />

on the heating delivery circuit, as specified in the national regulations.<br />

For the electrical connection of the thermostat, refer to the paragraph<br />

“Electrical connections”.<br />

If the delivery temperature is too high, the system stops in<br />

both domestic hot water and heating/cooling modes, and the<br />

remote control will report error code 936 “Under-floor safety<br />

thermostat open”. The system will start again when the manual-reset<br />

thermostat is closed.<br />

The input to be used as a connection to the under-floor safety<br />

thermostat is IN AUX 2 STE by default (function set through<br />

parameter 1.1.4).<br />

If the safety thermostat is connected to STE and the safety device<br />

intervenes, the circulation pump will continue to be fed<br />

and the anti-freeze protection is always guaranteed.<br />

If the safety thermostat is connected to STT and the safety device<br />

intervenes, the circulation pump will no longer be fed and<br />

the anti-freeze protection is not guaranteed.<br />

32 / EN