Contents<br />

1. Safety advices<br />

1.1 General warnings and safety instructions 4<br />

1.2 Use of the <strong>R32</strong> refrigerant 6<br />

1.3 Symbols affixed to the appliance 7<br />

2. Description of the system<br />

2.1 Outdoor unit (ODU) 8<br />

2.1.1 Structure 8<br />

2.1.2 Dimensions and weights 9<br />

2.1.3 Hydraulic and drainage fittings 10<br />

2.1.4 Accessories 10<br />

2.2 Indoor unit (IDU) 11<br />

2.2.1 Structure 11<br />

2.2.2 Dimensions and weights 13<br />

2.2.3 Hydraulic and drainage fittings 13<br />

2.3 Operational limits 14<br />

2.3.1 Compressor frequency table 14<br />

2.3.2 DHW Safety device intervention order 14<br />

2.4 Identification 15<br />

2.5 System interface SENSYS HD 16<br />

2.5.1 Technical data 17<br />

2.6 External probe 17<br />

3. <strong>Installation</strong><br />

3.1 Preliminary warnings 18<br />

3.2 Receiving the product 19<br />

3.3 Installing the outdoor unit 19<br />

3.3.1 Place of installation 19<br />

3.3.2 Noise level 20<br />

3.3.3 Handling 20<br />

3.3.4 <strong>Installation</strong> 21<br />

3.3.5 Arranging the connections 22<br />

3.3.6 Installing the accessory kit 22<br />

3.4 Installing the indoor unit 23<br />

3.4.1 Place of installation 23<br />

3.4.2 Handling 24<br />

4. Hydraulic connections<br />

4.1 Indoor unit hydraulic connections 25<br />

4.1.1 Safety valve drain 26<br />

4.1.2 Minimum water content 26<br />

4.1.3 Expansion vessel 26<br />

4.1.4 Rated and minimum flow rate 26<br />

4.1.5 Available pressure 27<br />

4.1.6 Characteristics of the supply water 28<br />

4.1.7 Filling the system 28<br />

4.2 <strong>Installation</strong> of the Hydraulic KIT 29<br />

4.2.1 Safety inlet assembly 29<br />

4.2.2 Exspansion vessel 29<br />

4.2.3 Tundish 29<br />

4.2.4 Safety device connection 29<br />

4.2.5 Hydraulic connections 30<br />

4.3 Example of schematic hydraulic diagram 31<br />

5. Electrical connections<br />

5.1 Outdoor unit electrical connections 35<br />

5.2 Indoor unit electrical connections 37<br />

5.3 Example of electrical connection between<br />

indoor and outdoor units 40<br />

5.4 Installing the system interface 41<br />

5.4.1 Wall installation 41<br />

5.4.2 On-board installation 41<br />

5.5 Installing the Light Gateway 43<br />

6. Commissioning<br />

6.1 Checking for electrical dispersions and gas<br />

leakages 45<br />

6.1.1 Electrical safety checks 45<br />

6.1.2 Check for gas leakages 45<br />

6.2 Preliminary checks 45<br />

6.3 Initial start-up 46<br />

6.3.1 Start-up procedure 46<br />

6.4 Basic functions 47<br />

6.5 Access to technical area 47<br />

6.6 Technical parameters 48<br />

6.7 Temperature adjustment 58<br />

6.8 Standard SG ready 62<br />

6.9 Parameter table 63<br />

7. Service<br />

7.1 Cleaning and inspecting the indoor unit 74<br />

7.2 Cleaning and inspecting the outdoor unit 74<br />

7.3 Error list 75<br />

8. Decommissioning<br />

8.1 Draining the circuit and recovering the<br />

refrigerant 78<br />

8.2 Disposal 79<br />

9. Technical information<br />

9.1 Data plate 80<br />

9.2 Technical data table for refrigerant 80<br />

10. Annexes<br />

EN / 3