Hydraulic connections<br />

4.1.5 Available pressure<br />

Hydraulic circuit<br />

Make sure that the available pressure is not lower than the<br />

head loss of the entire hydraulic system.<br />

The curves in the pictures below shown the available pressure<br />

on the flow from the outdoor unit.<br />

NIMBUS M EXT <strong>R32</strong><br />

kPa<br />

90<br />

80<br />

70<br />

60<br />

50<br />

40<br />

30<br />

20<br />

10<br />

1<br />

0<br />

0 500 1000 1500 2000 2500 3000 3500<br />

Fig. l/h43<br />

1 35 M - 50 M<br />

2 80 M - 80 M-T<br />

3 120 M - 120 M-T - 150 M - 150 M-T<br />

It is possible to install a supplementary circulator pump if the<br />

one supplied is not powerful enough. For the electrical connections,<br />

refer to the paragraph "Electrical connections".<br />

a<br />

If thermostatic or zones valves are installed on<br />

all terminals, mount a by-pass to guarantee the<br />

minimum operating flow rate. Consult the table<br />

in the paragraph “Rated and minimum flow rate”.<br />

2<br />

3<br />

Indoor unit head loss<br />

kPa<br />

45<br />

40<br />

35<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

0 500 1000 1500 2000 2500 3000<br />

l/h<br />

Useful head 1 zone<br />

Fig. 44<br />

kPa<br />

90<br />

80<br />

70<br />

60<br />

1<br />

50<br />

40<br />

30<br />

20<br />

10<br />

0<br />

0 500 1000 1500 2000 2500 3000 3500<br />

l/h<br />

1 Zone 1<br />

Fig. 45<br />

It is possible to install a supplementary circulator pump if the<br />

one supplied is not powerful enough. For the electrical connections,<br />

refer to the paragraph "Electrical connections".<br />

a<br />

If thermostatic or zones valves are installed on<br />

all terminals, mount a by-pass to guarantee the<br />

minimum operating flow rate. Consult the table<br />

in the paragraph “Rated and minimum flow rate”.<br />

DHW circuit<br />

The head loss of the primary heater was tested in accordance<br />

with the BS EN 12897:2016 standard and is equal to 3 kPa.<br />

EN / 27