<strong>Installation</strong><br />

– Attach the tray using the appropriate hooks (5).<br />

– Fasten the tray with the screws (3) and (4) removed<br />

previously.<br />

5<br />

5<br />

2<br />

3<br />

4<br />

4<br />

3<br />

Fig. 36<br />

3.4 Installing the indoor unit<br />

Fig. 33<br />

– To ensure correct operation of the kit, the unit must rest<br />

on a base measuring at least 70 mm.<br />

3.4.1 Place of installation<br />

To position the system, use the template provided and a spirit<br />

level.<br />

To avoid jeopardising the product’s operation, the place of<br />

installation must be adequate in relation to the threshold operating<br />

temperature (min +5°C) and protected against direct<br />

contact with atmospheric agents.<br />

Minimum installation distances<br />

H≥70<br />

mm<br />

Fig. 34<br />

350<br />

mm<br />

Condensate collection tray heating element<br />

– Position the heating element (1) on the bottom of the<br />

unit.<br />

350<br />

mm<br />

400<br />

mm<br />

1<br />

800<br />

mm<br />

Fig. 35<br />

– Pass the power cables (2) of the heating element<br />

through collar (3), cable hole (4) and collar (5).<br />

– To connect the heating element electrically, refer to the<br />

paragraph “Electrical connections”.<br />

i<br />

Fig. 37<br />

If the DHW Expansion Vessel is installed, it is necessary<br />

to leave a gap of at least 50 mm from the<br />

rear wall.<br />

EN / 23