2.5.1 Technical data<br />

TECHNICAL DATA<br />

Dimensions<br />

134 mm x 96 mm x 21 mm<br />

Power supply<br />

BUS BridgeNet® 8 to 24V max<br />

Current draw<br />

≤35mA<br />

Operating temperature 0 ÷ 50°C<br />

Storage temperature -10 ÷ 45°C<br />

Humidity<br />

20% RH ÷ 80% RH<br />

Temperature reading precision<br />

+/- 0,5°C<br />

Buffer memory duration<br />

min. 2h<br />

Bus cable length and<br />

max. 50 m ø min. 0.5 mm²<br />

cross-sectional area<br />

Note: in order to avoid interference problems, use a shielded<br />

cable or twisted-pair cable.<br />

PRODUCT TECHNICAL SHEET<br />

Supplier name<br />

ARISTON<br />

Supplier identification model<br />

SENSYS HD<br />

Temperature control class<br />

V<br />

Energy efficiency contribution % for<br />

+3%<br />

space heating<br />

Addition of an ARISTON outdoor sensor:<br />

Temperature control class<br />

VI<br />

Energy efficiency contribution % for<br />

+4%<br />

space heating<br />

In a system with 3 zones with 2 ARISTON room Sensors:<br />

Temperature control class<br />

VIII<br />

Energy efficiency contribution % for<br />

+5%<br />

space heating<br />

2.6 External probe<br />

PRODUCT TECHNICAL SHEET<br />

Supplier name<br />

ARISTON<br />

Supplier identification model OUTDOOR SENSOR<br />

Temperature control class<br />

II<br />

Energy efficiency contribution<br />

+2%<br />

% for space<br />

heating<br />

A B C<br />

Fig. 21<br />

– Position the outdoor sensor on the north-facing wall of<br />

the building, at least 2.5 m from the ground and away<br />

from direct sunlight.<br />

– Remove the cover (A) and install the sensor using the<br />

rawl plug and screw provided (B).<br />

– Make the connection using a 2x0.5 mm 2 cable. Maximum<br />

connection length 50 m.<br />

– Connect the wire to the terminal (C) by introducing it<br />

from the lower part after creating a suitable passage.<br />

– Place the sensor cover back in the correct position.<br />

17,8 mm<br />

134 mm<br />

95,6 mm<br />

Fig. 20<br />

EN / 17