Fire Alarm Cables - West Penn Wire
Fire Alarm Cables - West Penn Wire Fire Alarm Cables - West Penn Wire
Communication & Control Cables manufactures one of the largest, economical and reliable Communications and Control Cables in the Market. Low Voltage Circuitry cables are typically used for control purposes such as remote signalling, as well as communication applications. Typical systems could include sound audio, security, and intercom. These cables are designed and manufactured to meet NEC Article 725 and 800 requirements. All NEC rated cables are verified by an Independent Testing Laboratory. For more detailed information on our Communication cables, contact our Customer Service Department at , or e-mail us at: Information can also be found on our website: Mini Index Unshielded Cables - Audio and Control Cables Two Conductor/ Unshielded………………………………………………………… 2 Three Conductor/ Unshielded ……………………………………………………… 3 Four Conductor/ Unshielded………………………………………………………… 4 Multiple Conductor/ Unshielded…………………………………………………… 5-7 Multiple Pair/ Unshielded…………………………………………………………… 15-17 Shielded Cables - Audio and Control Cables Multiple Conductor/ Overall Shield……………………………………………… 8-10 Two Conductor/ Twisted Pair Overall Shielded ………………………………11 Three Conductor/ Overall Shield ………………………………………………… 12 Miniature Audio Cable/ Overall Shield ………………………………………… 13 Multiple Pair/ Overall Shield ……………………………………………………… 18-20 Multiple Pair/ Each Pair Shielded ………………………………………………… 21-23 Special Purpose Cables - Audio and Control Cables Sound and Audio/ Special Cable…………………………………………………… 14 Special Purpose Cable/ Shielded-Unshielded …………………………………24 Cluster Speaker Cable ………………………………………………………… 25-26 Special Purpose Cables - Audio and Control Cables Burglar Cables 2 Conductor……………………………………….….……… Burglar Cables 4 Conductor………………………………………..………… Over 95% of West Penn Wire cables are RoHS Compliant. For a detailed specification on individual products, contact our engineering department. 2 4 1
Catalog No. Communication & Control Cables Description: • ASTM Bare Copper • PVC insulation • Short overall twist lengths • Overall PVC jacket Rating: • NEC Type CMR or CL2R • (UL)-C(UL) Listed or (ETL)us - c(ETL)us Listed • Meets 300V requirements as specified in the NEC • Flame Rating: UL1666 No. of Cond. 220 2 221 2 222 2 224 2 225 2 226 2 227 2 Conductor Type & Nom. D.C.R 22 AWG Solid 17.5 Ω/Mft 22 AWG (7x30) 17 Ω/Mft 20 AWG (7x28) 10.5 Ω/Mft 18 AWG (7x26) 6.2 Ω/Mft 16 AWG (19x29) 4.2 Ω/Mft 14 AWG (19x27) 2.7 Ω/Mft 12 AWG (19x25) 1.7 Ω/Mft Insulation Type & Shielding Jacket Type Nom. Thickness & Thickness O.D. Inches Inches Inches PVC .010 PVC .010 PVC .010 PVC .010 PVC .010 PVC .014 PVC .014 None None None None None None None Burglar Wire Rating: • NEC Type CM 2 S221 2 22 AWG (7x30) 17 Ω/Mft Polypropylene .008 Special Notes: • Selected Plenum Versions see pages 28 • Selected Indoor/Outdoor Aquaseal Water Resistant® Versions see pages 40 & 43 • Select cables are available in our Easybox® • *- CL2R Meets 150V requirements for Low Voltage Circuits None Catalog Number Primary Color Code PVC .015 PVC .015 PVC .015 PVC .015 PVC .015 PVC .015 PVC .015 Communication & Control Cable Two Conductor / Unshielded PVC .015 220, 221,222, 224,225 1. Black, 2. Red NEC Type Applications: Indoor for: • Intercom Systems • Security Systems • Sound and Audio • Background Music • Power-limited Control Circuits Nom. Capacitance Jacket Color .118 -- Gray .127 -- .141 -- .155 -- .189 -- .234 -- .269 -- Color Code Standard spool size 1000ft. 226, 227 S221 1. Black, 2. White 1. Black, 2. Red Jacket: GY-Gray, BK-Black, BN-Brown, WH- White, RD-Red, YE- Yellow, BL-Blue GY, BN, WH GY, BN, WH GY, BK, BN, WH, BL, YE GY, BN, WH, BK, YE GY, BN, WH, BK, YE GY, BK, YE .102 -- GY, WH
- Page 2 and 3: West Penn Wire Cables Communication
- Page 4 and 5: Aquaseal® Cable.........pages 37-4
- Page 8 and 9: Communication & Control Cables Comm
- Page 10 and 11: Communication & Control Cable Multi
- Page 12 and 13: Communication & Control Cables Comm
- Page 14 and 15: Communication & Control Cables Comm
- Page 16 and 17: Communication & Control Cables Comm
- Page 18 and 19: Communication & Control Cables Comm
- Page 20 and 21: Communication & Control Cables Comm
- Page 22 and 23: Communication & Control Cables Comm
- Page 24 and 25: Communication & Control Cables Comm
- Page 26 and 27: Communication & Control Cables Comm
- Page 28 and 29: Communication & Control Cables Comm
- Page 30 and 31: Communication & Control Cables Comm
- Page 32 and 33: Communication & Control Plenum Cabl
- Page 34 and 35: Communication & Control Plenum Cabl
- Page 36 and 37: Communication & Control Plenum Cabl
- Page 38 and 39: Communication & Control Plenum Cabl
- Page 40 and 41: Communication & Control Plenum Cabl
- Page 42 and 43: Aquaseal Cables Over 95% of West Pe
- Page 44 and 45: Aquaseal® Water Blocking Cable Two
- Page 46 and 47: Aquaseal® Water Blocking Cable Mul
- Page 48 and 49: Aquaseal® Water Blocking Cable Mul
- Page 50 and 51: Tray Cable/ Class 1 600V Multiple C
- Page 52 and 53: Fire Alarm Cables Power-Limited Cab
- Page 54 and 55: Fire Alarm Cables Power-Limited Mul
Communication & Control <strong>Cables</strong><br />
manufactures one of the largest,<br />
economical and reliable Communications and Control<br />
<strong>Cables</strong> in the Market. Low Voltage<br />
Circuitry cables are typically used for control purposes<br />
such as remote signalling, as well as communication<br />
applications. Typical systems could include sound<br />
audio, security, and intercom.<br />
These cables are designed and manufactured to meet<br />
NEC Article 725 and 800 requirements. All NEC rated<br />
cables are verified by an Independent Testing<br />
Laboratory.<br />
For more detailed information on our Communication<br />
cables, contact our Customer Service Department at<br />
, or e-mail us at:<br />
Information can also be<br />
found on our website:<br />
Mini Index<br />
Unshielded <strong>Cables</strong> - Audio and Control <strong>Cables</strong><br />
Two Conductor/ Unshielded………………………………………………………… 2<br />
Three Conductor/ Unshielded ……………………………………………………… 3<br />
Four Conductor/ Unshielded………………………………………………………… 4<br />
Multiple Conductor/ Unshielded…………………………………………………… 5-7<br />
Multiple Pair/ Unshielded…………………………………………………………… 15-17<br />
Shielded <strong>Cables</strong> - Audio and Control <strong>Cables</strong><br />
Multiple Conductor/ Overall Shield……………………………………………… 8-10<br />
Two Conductor/ Twisted Pair Overall Shielded ………………………………11<br />
Three Conductor/ Overall Shield ………………………………………………… 12<br />
Miniature Audio Cable/ Overall Shield ………………………………………… 13<br />
Multiple Pair/ Overall Shield ……………………………………………………… 18-20<br />
Multiple Pair/ Each Pair Shielded ………………………………………………… 21-23<br />
Special Purpose <strong>Cables</strong> - Audio and Control <strong>Cables</strong><br />
Sound and Audio/ Special Cable…………………………………………………… 14<br />
Special Purpose Cable/ Shielded-Unshielded …………………………………24<br />
Cluster Speaker Cable ………………………………………………………… 25-26<br />
Special Purpose <strong>Cables</strong> - Audio and Control <strong>Cables</strong><br />
Burglar <strong>Cables</strong> 2 Conductor……………………………………….….………<br />
Burglar <strong>Cables</strong> 4 Conductor………………………………………..…………<br />
Over 95% of <strong>West</strong> <strong>Penn</strong> <strong>Wire</strong> cables are RoHS<br />
Compliant. For a detailed specification on individual<br />
products, contact our engineering department.<br />
2<br />
4<br />