Fire Alarm Cables - West Penn Wire
Fire Alarm Cables - West Penn Wire Fire Alarm Cables - West Penn Wire
Data Grade Cable Multiple Pair Series / Overall Shielded RS-485 Data Cables Applications: Indoor for: • Computer Application • Low Capacitance Data • RS-485 Data Applications Standard spool size 1000ft. Catalog No. No. of Pairs D4851 1 D4852 2 D4853 3 D4854 4 Conductor Type & Nom. D.C.R 24 AWG (7x32) 26 Ω/Mft Color Code Pair No. Colors Insulation Type & Thickness Polyolefin .020 1 Blue- White 2 Orange- White 3 Green- White 4 Brown- White Data Grade Cable 24 AWG (7x32) 26 Ω/Mft 24 AWG (7x32) 26 Ω/Mft 24 AWG (7x32) 26 Ω/Mft JACKET: Gray Description: • ASTM Tinned Copper • Polyolefin Insulation • Twisted pair construction • Polyester wrap • Overall shield 100% coverage of aluminum polyester foil with 24 Awg. Stranded drain wire • 90% Tinned Copper Braid • Overall PVC Jacket Rating: • NEC Type CM • (UL) Listed • Meets 300V requirements as specified in the NEC • Flame Rating: UL1685 Shielding & & Coverage Jacket Type Nom. & Thickness O.D. Inches Inches Inches Al. Foil- 100% with drain wire TC Braid 90% PVC .032 .275 Polyolefin .020 Polyolefin .020 Polyolefin .020 Al. Foil- 100% with drain wire TC Braid 90% Al. Foil- 100% with drain wire TC Braid 90% Al. Foil- 100% with drain wire TC Braid 90% PVC .032 PVC .032 PVC .032 .305 .320 .345 NEC Type Nom. Capacitance 12.8 pf/ft* 23 pf/ft** 12.8 pf/ft* 23 pf/ft** 12.8 pf/ft* 23 pf/ft** 12.8 pf/ft* 23 pf/ft** Jacket Color Gray Gray Gray Gray Electrical Characteristics Nom. Vel of Propagation - 66% Nom. Impedance Ω 24 Awg.- 120Ω * Capacitance between conductors. ** Capacitance between one conductor and the other connected to the shield 109
Description: • ASTM Tinned Copper • Foam Teflon Insulation • Twisted Pair Construction • Polyester wrap • Overall shield 100% coverage of aluminum polyester foil with 24 Awg. Stranded drain wire • 90% Tinned Copper Braid • Overall Flexible Plenum Jacket Rating: • NEC Type CMP • (UL) Listed • Meets 300V requirements as specified in the NEC • Flame Rating: NFPA-262 Smoke & Flame Test Catalog No. D254851 New D254852 New 110 No. of Pairs 1 2 Conductor Type & Nom. D.C.R 24 AWG (7x32) 26 Ω/Mft 24 AWG (7x32) 26 Ω/Mft Insulation Type & Thickness Shielding & & Coverage Jacket Type Nom. & Thickness O.D. Inches Inches Inches Foam Teflon® Foam Teflon® Color Code Pair No. Colors 1 Blue- White 2 Orange- White JACKET: Gray Data Grade Cable Al. Foil- 100% with drain wire TC Braid 90% Al. Foil- 100% with drain wire TC Braid 90% Data Grade Plenum Cable Multiple Pair Series / Overall Shielded RS-485 Data Cables Flex. Plenum .202 Flex. Plenum .305 Applications: Indoor within ducts,plenums and other spaces used for environmental air: • Computer Application • Low Capacitance Data • RS-485 Data Applications NEC Type Standard spool size 1000ft. Nom. Capacitance 12 pf/ft* 22 pf/ft** 12 pf/ft* 22 pf/ft** Electrical Characteristics Nom. Vel of Propagation - 76% Nom. Impedance Ω 24 Awg.- 120Ω Jacket Color Gray Gray * Capacitance between conductors. ** Capacitance between one conductor and the other connected to the shield Special Notes: • Teflon®- Dupont Tradename for FEP-Fluorinated Ethylene Propylene
- Page 64 and 65: Circuit Integrity/ Shielded (CI) -
- Page 66 and 67: Coaxial Cables Mini Index is one of
- Page 68 and 69: CATV/MATV RG6/U Type Applications:
- Page 70 and 71: CATV/MATV RG59/U & RG6/U Type Plene
- Page 72 and 73: CATV/MATV RG11/U Type Plenecon® PL
- Page 74 and 75: CCTV/ Security Video RG59/U Type Ap
- Page 76 and 77: CCTV/ Security Video RG59/U Type Pl
- Page 78 and 79: CCTV/ Security Video RG6/U Type Ple
- Page 80 and 81: Coaxial Cables V-Cat- Video Over UT
- Page 82 and 83: Catalog No. PTZ25825 Catalog No. PT
- Page 84 and 85: Broadcast Coaxial Cables Video Cabl
- Page 86 and 87: Broadcast Video Cable Electrical Sp
- Page 88 and 89: Broadcast Video Cable RGB 25 & 26 A
- Page 90 and 91: Broadcast Video Cable High Resoluti
- Page 92 and 93: Broadcast Video Cable Video Triaxia
- Page 94 and 95: M58813 4 Pair Broadcast Coaxial Cab
- Page 96 and 97: Broadcast Coaxial Cables Broadcast
- Page 98 and 99: Broadcast Cable Install Kits/ HD15
- Page 100 and 101: Broadcast Audio Professional Audio
- Page 102 and 103: Broadcast Audio Plenum Cable Two Co
- Page 104 and 105: Broadcast Audio Plenum Cable Multip
- Page 106 and 107: Broadcast Audio Miniature Dual Audi
- Page 108 and 109: Broadcast Audio AES/ EBU Digital Au
- Page 110 and 111: Data Grade Cable Mini Index Non-Ple
- Page 112 and 113: Data Grade Cable Multiple Pair Seri
- Page 116 and 117: LAN Cable Local Area Network (LAN)
- Page 118 and 119: LAN Cables 2 & 3 Pair Category 5 Ap
- Page 120 and 121: LAN Cables Category 6- Digital Inte
- Page 122 and 123: LAN Cables High Pair Count Category
- Page 124 and 125: Fiber Optic Cable Indoor Fiber Opti
- Page 126 and 127: Fiber Optic Cables Simplex and Dupl
- Page 128 and 129: Fiber Optic Cables Distribution Cab
- Page 130 and 131: Fiber Optic Cables Breakout Cable/
- Page 132 and 133: Fiber Optic Cables Indoor/Outdoor T
- Page 134 and 135: Fiber Optic Cables Armored Loose-Tu
- Page 136 and 137: Fiber Optic Cables Riserlite Armore
- Page 138 and 139: Residential Cables takes great prid
- Page 140 and 141: Home Speaker Cable Four Conductor /
- Page 142 and 143: Media Control Cable Specialized Con
- Page 144 and 145: Special Application Cables Special
- Page 146 and 147: Special Application Cables V-Cat- V
- Page 148 and 149: Catalog No. NEC Type Catalog No. NE
- Page 150 and 151: West Penn Wire has developed the Ac
- Page 152 and 153: SVHS ECONOMY CABLE ASSEMBLIES CAT.
- Page 154 and 155: HDMI TO HDMI with REPEATERS CAT. NO
- Page 156 and 157: VGA Install Kits- 26 AWG - WP258265
- Page 158 and 159: VGA Install Kits- 25 AWG - 5CRGB No
- Page 160 and 161: 75 Ω BNC Connectors CAT. NO. Camb
- Page 162 and 163: “F” Type Compression Connectors
Data Grade Cable<br />
Multiple Pair Series / Overall Shielded<br />
RS-485 Data <strong>Cables</strong><br />
Applications:<br />
Indoor for:<br />
• Computer Application<br />
• Low Capacitance Data<br />
• RS-485 Data Applications<br />
Standard spool size 1000ft.<br />
Catalog<br />
No.<br />
No. of<br />
Pairs<br />
D4851 1<br />
D4852 2<br />
D4853 3<br />
D4854 4<br />
Conductor<br />
Type &<br />
Nom. D.C.R<br />
24 AWG<br />
(7x32)<br />
26 Ω/Mft<br />
Color Code<br />
Pair No. Colors<br />
Insulation<br />
Type &<br />
Thickness<br />
Polyolefin<br />
.020<br />
1 Blue- White<br />
2 Orange- White<br />
3 Green- White<br />
4 Brown- White<br />
Data Grade Cable<br />
24 AWG<br />
(7x32)<br />
26 Ω/Mft<br />
24 AWG<br />
(7x32)<br />
26 Ω/Mft<br />
24 AWG<br />
(7x32)<br />
26 Ω/Mft<br />
JACKET: Gray<br />
Description:<br />
• ASTM Tinned Copper • Polyolefin Insulation • Twisted pair<br />
construction • Polyester wrap • Overall shield 100% coverage of<br />
aluminum polyester foil with 24 Awg. Stranded drain wire<br />
• 90% Tinned Copper Braid • Overall PVC Jacket<br />
Rating:<br />
• NEC Type CM<br />
• (UL) Listed<br />
• Meets 300V requirements as specified in the NEC<br />
• Flame Rating: UL1685<br />
Shielding<br />
&<br />
& Coverage<br />
Jacket Type Nom.<br />
& Thickness O.D.<br />
Inches Inches Inches<br />
Al. Foil-<br />
100% with<br />
drain wire<br />
TC Braid<br />
90%<br />
PVC<br />
.032<br />
.275<br />
Polyolefin<br />
.020<br />
Polyolefin<br />
.020<br />
Polyolefin<br />
.020<br />
Al. Foil-<br />
100% with<br />
drain wire<br />
TC Braid<br />
90%<br />
Al. Foil-<br />
100% with<br />
drain wire<br />
TC Braid<br />
90%<br />
Al. Foil-<br />
100% with<br />
drain wire<br />
TC Braid<br />
90%<br />
PVC<br />
.032<br />
PVC<br />
.032<br />
PVC<br />
.032<br />
.305<br />
.320<br />
.345<br />
NEC<br />
Type<br />
Nom.<br />
Capacitance<br />
12.8 pf/ft*<br />
23 pf/ft**<br />
12.8 pf/ft*<br />
23 pf/ft**<br />
12.8 pf/ft*<br />
23 pf/ft**<br />
12.8 pf/ft*<br />
23 pf/ft**<br />
Jacket<br />
Color<br />
Gray<br />
Gray<br />
Gray<br />
Gray<br />
Electrical Characteristics<br />
Nom. Vel of Propagation - 66%<br />
Nom. Impedance Ω 24 Awg.- 120Ω<br />
* Capacitance between conductors.<br />
** Capacitance between one conductor and the<br />
other connected to the shield<br />
109