5361- Kilmainhamwood Compost Facility Extension- EIS<br />

Table 9.7 Predicted Overall Odour Emission Rate from Proposed Kilmainhamwood Composting Facility Design (Ref Scenario 2).<br />

Odour emission rate<br />

(OuE/s)<br />

Volumetric airflow rate<br />

(m 3 Odour threshold concentration<br />

/s)<br />

(OuE/m 3 )<br />

BF 1 30,000 8.33 800 6,664<br />

Volumetric airflow rate<br />

(m 3 /hr)<br />

Emission source<br />

BF2-1 25,000 6.94<br />

BF2-2 25,000 6.94<br />

Subtotal BF2 50,000 2 13.89 800 11,112<br />

22.23 800 17,776<br />

80,000 3<br />

Total 1<br />

Notes:<br />

1<br />

denotes that all waste handling and <strong>compost</strong>ing operations are carried out indoors. This includes waste reception, shredding, addition of amendment<br />

and mixing of feedstocks, loading of material into first stage and second stage enclosed <strong>compost</strong>ing bays, screening of <strong>compost</strong> and loading of<br />

<strong>compost</strong> into Animal By-Product treatment tunnels. The containment principle applies here to ensure no emissions of odours escape to atmosphere.<br />

2<br />

denotes that process air will be collected directly from the enclosed <strong>compost</strong>ing bays and directed to an acid scrubber for ammonia removal and then<br />

be ducted directly to the optimised biofiltration system for treatment.<br />

3 3<br />

denotes that in order to ensure negative pressure within the building a total volumetric airflow rate of 30,000 m /hr of air will be ventilated from the<br />

<strong>compost</strong>ing building headspace. Makeup aeration air for the <strong>compost</strong>ing tunnels will be taken from the building while additional building ventilation air<br />

will be extracted to ensure effective negative ventilation.<br />