simatic<br />

SIMATIC PCS 7<br />

Process Control <strong>System</strong><br />

Catalog ST PCS 7 · October 2004


Related catalogs<br />

SIMATIC<br />

Add-Ons for the SIMATIC PCS 7<br />

Process Control <strong>System</strong><br />

Order No.:<br />

E86060-K4678-A121-A4-7600<br />

SIMATIC<br />

Products for<br />

Totally Integrated <strong>Automation</strong><br />

<strong>and</strong> Micro <strong>Automation</strong><br />

Order No.:<br />

E86060-K4670-A101-A9-7600<br />

SIMATIC HMI<br />

Human Machine Interface<br />

<strong>System</strong>s<br />

Order No.:<br />

E86060-K4680-A101-B2-7600<br />

Industrial Communication<br />

Industrial Communication for<br />

<strong>Automation</strong> <strong>and</strong> <strong>Drives</strong><br />

Order No.:<br />

E86060-K6710-A101-B4-7600<br />

TELEPERM M<br />

AS 488/TM<br />

<strong>Automation</strong> <strong>System</strong>s<br />

Order No.:<br />

E86060-W3812-A100-A3-7600<br />

Field instruments for<br />

Process <strong>Automation</strong><br />

Order No.:<br />

E86060-K6201-A101-A6-7600<br />

Trademarks<br />

ST PCS 7.A<br />

ST 70<br />

ST 80<br />

IK PI<br />

PLT 112<br />

FI 01<br />

All product designations may be trademarks or product<br />

names of <strong>Siemens</strong> AG or supplier companies whose<br />

use by third parties for their own purposes could violate<br />

the rights of the owners.<br />

SITRAIN ITC<br />

Training for <strong>Automation</strong> <strong>and</strong><br />

Industrial Solutions<br />

Order No.:<br />

E86060-K6850-A101-B5<br />

CD-ROM: E86060-D6850-A100-C2-7400<br />

Components<br />

for <strong>Automation</strong><br />

Order No.:<br />

E86060-D4001-A100-C2-7600<br />

A&D Mall<br />

CA 01<br />

Internet:<br />

www.siemens.com/automation/mall


SIMATIC PCS 7<br />

Process Control <strong>System</strong><br />

Catalog<br />

ST PCS 7 · October 2004<br />

Online Edition<br />

The products listed in this catalog<br />

are also available in the electronic<br />

Catalog CA 01 on CD-ROM<br />

Order No.:<br />

E86060-D4001-A100-C3-7600<br />

Please contact your nearest<br />

<strong>Siemens</strong> branch office<br />

© <strong>Siemens</strong> AG 2004<br />

The products <strong>and</strong> systems<br />

described in this<br />

catalog are manufactured/distributed<br />

under<br />

application of a certified<br />

quality management<br />

system in accordance<br />

with DIN EN ISO 9001<br />

(Certified Registration<br />

No. 1323-03). The certificate<br />

is recognized by<br />

all IQNet countries.<br />

s<br />

Introduction<br />

<strong>System</strong>-neutral components<br />

SIMATIC PCS 7 BOX<br />

<strong>Engineering</strong> <strong>System</strong><br />

Operator <strong>System</strong><br />

Batch automation<br />

SIMATIC Route Control<br />

IT world<br />

Communication<br />

<strong>Automation</strong> systems<br />

Process I/O<br />

Migration to SIMATIC PCS 7<br />

Appendix<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

11<br />

12<br />

13


1/2<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

Welcome to<br />

<strong>Automation</strong> <strong>and</strong> <strong>Drives</strong><br />

We would like to welcome you to <strong>Automation</strong> <strong>and</strong><br />

<strong>Drives</strong> <strong>and</strong> our comprehensive range of products,<br />

systems, solutions <strong>and</strong> services for production <strong>and</strong><br />

process automation <strong>and</strong> building technology<br />

worldwide.<br />

With Totally Integrated <strong>Automation</strong> <strong>and</strong> Totally<br />

Integrated Power, we deliver solution platforms based<br />

on st<strong>and</strong>ards that offer you a considerable savings<br />

potential.<br />

Discover the world of our technology now. If you need<br />

more detailed information, please contact one of your<br />

regional <strong>Siemens</strong> partners.<br />

They will be glad to assist you.


<strong>Siemens</strong> ST PCS 7 · October 2004<br />

1/3


1/4<br />

Industrial<br />

Industrial<br />

Ethernet<br />

PROCESS FIELD<br />

PROFIBUS<br />

Ethernet<br />

AS-Interface<br />

GAMMA instabus<br />

Control<br />

Safety Integrated<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

Totally Integrated <strong>Automation</strong> –<br />

innovations for more productivity<br />

With the launch of Totally Integrated <strong>Automation</strong>, we were<br />

the first ones on the market to consistently implement the<br />

trend from equipment to an integrated automation solution,<br />

<strong>and</strong> have continuously improved the system ever since.<br />

Whether your industry is process- <strong>and</strong> production-oriented or<br />

a hybrid, Totally Integrated <strong>Automation</strong> is a unique "common<br />

solution" platform that covers all the sectors.<br />

Totally Integrated <strong>Automation</strong> is an integrated platform for the<br />

entire production line - from receiving to technical processing<br />

SIMATIC NET<br />

Industrial<br />

Communication<br />

ERP<br />

Enterprise<br />

Resource<br />

Planning<br />

MES<br />

Manufacturing<br />

Execution<br />

<strong>System</strong>s<br />

SINAUT Telecontrol<br />

<strong>System</strong><br />

PC-based <strong>Automation</strong><br />

Building<br />

Technology<br />

Ethernet<br />

Production<br />

Order<br />

Management<br />

Production<br />

Operations<br />

Recording<br />

SIMATIC<br />

Machine Vision<br />

Ethernet<br />

SIMATIC<br />

Software<br />

Micro-<strong>Automation</strong><br />

<strong>and</strong><br />

Actuator-Sensor<br />

Interface Level<br />

Material<br />

Management<br />

Equipment<br />

Management<br />

Industrial Wireless<br />

Communication/<br />

MOBIC<br />

ECOFAST IP65<br />

Decentral<br />

<strong>Automation</strong> <strong>System</strong>


SIMATIC<br />

Controller/<br />

<strong>Automation</strong><br />

<strong>System</strong><br />

SIMATIC IT Framework<br />

Production Modeler<br />

SENTRON<br />

Circuit<br />

Breakers<br />

SIMATIC<br />

Distributed<br />

I/O<br />

<strong>and</strong> production areas to shipping. Thanks to the system-oriented<br />

engineering environment, integrated, open communications<br />

as well as intelligent diagnostics options, your plant now<br />

benefits in every phase of the life cycle.<br />

In fact, to this day we are the only company worldwide that<br />

can offer a control system based on an integrated platform<br />

for both the production <strong>and</strong> process industry.<br />

SIMATIC PCS 7<br />

Process Control<br />

<strong>System</strong><br />

Field Instrumentation/<br />

Analytics<br />

Plant<br />

Information<br />

Management<br />

Detailed<br />

Production<br />

Scheduling<br />

SINUMERIK<br />

Numeric<br />

Control<br />

Product Specification<br />

Management <strong>System</strong><br />

Laboratory Information<br />

Management <strong>System</strong><br />

SIMOTION<br />

Motion Control<br />

<strong>System</strong><br />

Sensor<br />

Technology<br />

IQ-Sense<br />

HART<br />

SIMOCODE-DP<br />

Motor<br />

PROFIBUS PA<br />

Protection<br />

<strong>and</strong> Control<br />

SIWAREX<br />

Weighing<br />

Technology<br />

SIMODRIVE SINAMICS<br />

SIMATIC HMI<br />

Human Machine<br />

Interface<br />

Drive <strong>System</strong>s/<br />

SINAMICS<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

1/5


1/6<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

Totally Integrated Power –<br />

energy distribution <strong>and</strong> management<br />

from one source<br />

Totally Integrated Power by <strong>Siemens</strong> offers integrated<br />

solutions for energy distribution in functional <strong>and</strong> industrial<br />

buildings covering everything from medium-high voltage to<br />

power outlets.<br />

Totally Integrated Power is based on integration in<br />

planning <strong>and</strong> configuration as well as coordinated products<br />

<strong>and</strong> systems. In addition, it features communications <strong>and</strong><br />

software modules for connecting power distribution systems<br />

to industrial automation <strong>and</strong> building automation, thereby<br />

offering a substantial savings potential.<br />

Communications<br />

Process/production<br />

automation<br />

Products <strong>and</strong> systems<br />

Planning <strong>and</strong> configuration<br />

PROCESS FIELD BUS<br />

HMI Load<br />

Graphs Prognoses<br />

management<br />

U<br />

I<br />

cos o<br />

P<br />

W<br />

£ 110 kV


Maintenance<br />

Substation<br />

Distribution<br />

Maintenance<br />

task<br />

Hall 1 Air conditioning system<br />

checkup<br />

Distribution 3 Replacing circuit<br />

breaker contacts<br />

Infeed II Replacing meters<br />

Message/<br />

error<br />

management<br />

central ON<br />

OFF<br />

local ON<br />

OFF<br />

tripped<br />

Selective<br />

protection<br />

Protocols Power<br />

DATE:<br />

quality<br />

EMPLOYEE<br />

COST CENTER<br />

PAY PERIOD BEGINNING<br />

PAY PERIOD ENDING<br />

DATE<br />

SUN MON TUE WED THUR FRI SAT SUN TOTAL<br />

IN<br />

OUT<br />

IN<br />

OUT<br />

OVERTIME<br />

TOTAL HOURS<br />

DATE<br />

SUN MON TUE WED THUR FRI SAT SUN TOTAL<br />

IN<br />

OUT<br />

IN<br />

OUT<br />

OVERTIME<br />

TOTAL HOURS<br />

DATE<br />

SUN MON TUE WED THUR FRI SAT SUN TOTAL<br />

IN<br />

OUT<br />

IN<br />

OUT<br />

OVERTIME<br />

TOTAL HOURS<br />

CODES<br />

V=VACATION<br />

H=HOLIDAY<br />

S=SICK<br />

REGULAR HOLIDAY OTHER<br />

OVER THE HOURS<br />

SICK VACATION<br />

TIME & ONE-HALF<br />

Cost center<br />

instabus EIB<br />

Building<br />

automation<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

1/7


Introduction<br />

<strong>System</strong> architecture<br />

SIMATIC PCS 7<br />

■ Overview<br />

SIMATIC PCS 7 <strong>System</strong> Configuration<br />

SIMATIC PCS 7 – The process control system for Totally Integrated<br />

<strong>Automation</strong><br />

Using Totally Integrated <strong>Automation</strong> (TIA), <strong>Siemens</strong> provides uniform<br />

automation technology on one single platform for all applications<br />

of process automation, starting with input logistics, covering<br />

production or primary processes as well as downstream<br />

(secondary) processes, up to output logistics. This uniform automation<br />

technology also facilitates the optimization of all company<br />

operations, covering the enterprise resource planning<br />

(ERP) level, the management execution system (MES) level, the<br />

process control level, down to the field level.<br />

Horizontal integration<br />

Horizontal integration means that common <strong>and</strong> st<strong>and</strong>ard hardware/software<br />

components from the SIMATIC product portfolio<br />

are used for the complete production process - covering input<br />

logistics, primary <strong>and</strong> secondary processes, up to output logistics.<br />

As the process control system component of Totally Integrated<br />

<strong>Automation</strong>, SIMATIC PCS 7 uses st<strong>and</strong>ard hardware <strong>and</strong> software<br />

components from the SIMATIC TIA range. The uniform data<br />

management, communication <strong>and</strong> configuration capabilities of<br />

TIA offer an open platform for advanced, future-oriented <strong>and</strong><br />

economical automation solutions in all sectors of the process industry,<br />

manufacturing industry <strong>and</strong> hybrid industries (which include<br />

a mixture of continuous/batch/discrete processes such as<br />

in the glass or pharmaceuticals industries).<br />

While secondary <strong>and</strong> logistics processes in the process <strong>and</strong> hybrid<br />

industries are often automated by Motion Control <strong>and</strong><br />

SIMATIC components, the primary processes are a domain of<br />

the SIMATIC PCS 7 process control system.<br />

1/8<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

Within the TIA network, SIMATIC PCS 7 not only h<strong>and</strong>les st<strong>and</strong>ard<br />

(primary) process control tasks, but it can also automate<br />

secondary processes (e.g. filling, packaging) or input/output logistics<br />

(e.g. raw material distribution, storage) for a production<br />

location.<br />

Vertical integration<br />

Vertical integration is characterized by uniform <strong>and</strong> transparent<br />

data communication from the ERP level, through the MES level<br />

<strong>and</strong> the Control level, down to the field level. It is reflected in the<br />

increased fusion of automation technology <strong>and</strong> information technology<br />

<strong>and</strong> their st<strong>and</strong>ards in the wake of establishing companywide<br />

information networks. This enables the modularization <strong>and</strong><br />

st<strong>and</strong>ardization of whole subprocesses, resulting in far higher<br />

flexibility of production.<br />

Vertical integration of SIMATIC PCS 7 into the company environment<br />

includes:<br />

Integration in the company-wide information network<br />

Integration of field systems<br />

By linking the automation level to the IT world, process data becomes<br />

available throughout the company for evaluation, planning,<br />

coordination <strong>and</strong> optimization of operation, production processes<br />

<strong>and</strong> commercial processes. Also taken into account are<br />

the geographical requirements of distributed production facilities,<br />

as is the case with global companies.


SIMATIC PCS 7 is optimized for integration of distributed field<br />

systems into the process control system, <strong>and</strong> is based on<br />

PROFIBUS technology. PROFIBUS is simple, rugged <strong>and</strong> reliable,<br />

<strong>and</strong> is used worldwide in all sectors of the process, manufacturing<br />

<strong>and</strong> hybrid industries – for input/output logistics as well<br />

as for primary <strong>and</strong> secondary processes. It supports redundancy<br />

<strong>and</strong> failsafe architectures, in addition to online expansions,<br />

<strong>and</strong> can be used in st<strong>and</strong>ard environments or in hazardous<br />

areas. The plant can be equipped with classical signal<br />

inputs/outputs on the ET 200 distributed I/O station, or with<br />

state-of-the-art, intelligent field devices.<br />

■ Benefits<br />

The innovative design of SIMATIC PCS 7 is based on a modular<br />

<strong>and</strong> open architecture using state-of-the-art SIMATIC technology,<br />

consistent implementation of industrial st<strong>and</strong>ards, <strong>and</strong> process<br />

control functionalities combined with high performance.<br />

This means that with the SIMATIC PCS 7 process control system,<br />

users can achieve cost-effective implementation <strong>and</strong> economical<br />

operation of process control facilities during all phases of<br />

their life cycle <strong>and</strong> with due allowance for all aspects: from planning,<br />

engineering, commissioning <strong>and</strong> training to operation,<br />

maintenance, servicing, expansion <strong>and</strong> renovation. In the process,<br />

SIMATIC PCS 7 unifies high performance <strong>and</strong> reliability<br />

with simple <strong>and</strong> safe operation <strong>and</strong> maximum convenience.<br />

Customers benefit from Totally Integrated <strong>Automation</strong> <strong>and</strong> the<br />

SIMATIC PCS 7 process control system mainly through<br />

calculable development, implementation <strong>and</strong> life cycle costs,<br />

minimization of engineering resources,<br />

process optimization options,<br />

flexibility to adapt quickly to changes in requirements,<br />

advantages resulting from the use of SIMATIC st<strong>and</strong>ard components,<br />

such as<br />

- low hardware <strong>and</strong> engineering costs,<br />

- proven quality <strong>and</strong> stability,<br />

- simple, fast definition <strong>and</strong> selection of system components,<br />

- low costs for spare parts,<br />

- short delivery times for spare parts <strong>and</strong> expansion components,<br />

- worldwide availability,<br />

- savings in logistics, maintenance <strong>and</strong> training costs.<br />

■ Function<br />

A consistent <strong>and</strong> homogeneous overall system<br />

SIMATIC PCS 7 is a modern process control system that can be<br />

used alone <strong>and</strong> in combination with Motion Control <strong>and</strong> SIMATIC<br />

as a consistent <strong>and</strong> homogeneous overall system. The appeal of<br />

SIMATIC PCS 7 is likely to increase in keeping with the dem<strong>and</strong><br />

for seamless, consistent automation engineering, fueled by unrelenting<br />

competition <strong>and</strong> pressure on prices, <strong>and</strong> the dem<strong>and</strong><br />

for production plants of increasing flexibility, <strong>and</strong> the need to enhance<br />

productivity.<br />

Against the background of increasing complexity, due in particular<br />

to the merging of automation engineering with information<br />

technology, the importance of system platforms that are uniform<br />

in both horizontal <strong>and</strong> vertical directions is growing, while that of<br />

automation solutions with so-called "best-in-class products“ is<br />

waning. As a component of Totally Integrated <strong>Automation</strong>, SI-<br />

MATIC PCS 7 is therefore ideally equipped for the challenges of<br />

the future.<br />

Introduction<br />

<strong>System</strong> architecture<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

SIMATIC PCS 7<br />

High performance <strong>and</strong> outst<strong>and</strong>ing system characteristics - together<br />

with consistent data management, communication <strong>and</strong><br />

configuration - guarantee that the typical dem<strong>and</strong>s made of a<br />

process control system are fully met by SIMATIC PCS 7:<br />

7 simple <strong>and</strong> reliable process control,<br />

7 user-friendly operation <strong>and</strong> visualization,<br />

7 powerful, fast <strong>and</strong> consistent system-wide engineering,<br />

7 system-wide online alterability,<br />

7 open system architecture at all levels,<br />

7 flexibility <strong>and</strong> scalability,<br />

7 redundancy at all levels,<br />

7 failsafe automation solutions,<br />

7 comprehensive field bus integration,<br />

7 flexible solutions for batch processes,<br />

7 direct connection to the IT world.<br />

Flexibility <strong>and</strong> scalability<br />

As a result of its modular <strong>and</strong> open architecture, which is based<br />

on selected hardware <strong>and</strong> software components from the st<strong>and</strong>ard<br />

SIMATIC range, SIMATIC PCS 7 can be applied effectively<br />

in small <strong>and</strong> large plants alike. It allows easy expansion or system<br />

modification to enable customers to meet the changing production<br />

requirements of their facility. SIMATIC PCS 7 is scalable<br />

from a small single system consisting of approx. 160 process<br />

objects (motors, valves, PID controllers), such as might be used<br />

for a laboratory system or a test center, up to a distributed multiuser<br />

system with client/server architecture <strong>and</strong> approx.<br />

60,000 process objects, such as might be used for automation<br />

of a very large production plant or for groups of connected facilities.<br />

SIMATIC PCS 7 thus covers all sizes of plant - <strong>and</strong> if the plant<br />

grows, SIMATIC PCS 7 grows with it!<br />

Open for the future<br />

SIMATIC PCS 7 is based on modular hardware <strong>and</strong> software<br />

components, which are perfectly matched to one another due to<br />

their conformance with TIA. These components are flexible <strong>and</strong><br />

exp<strong>and</strong>able, <strong>and</strong> are open for future enhancements through the<br />

use of st<strong>and</strong>ard interfaces with long-term stability. This means it<br />

is possible to provide long-term protection for customer investments<br />

despite high innovation speeds <strong>and</strong> short product life cycles.<br />

SIMATIC PCS 7 consistently applies new, powerful technologies<br />

together with internationally established industrial st<strong>and</strong>ards<br />

such as IEC, XML, PROFIBUS, Ethernet, TCP/IP, OPC,<br />

@aGlance, ISA 88 <strong>and</strong> ISA 95, just to mention a few.<br />

SIMATIC PCS 7’s openness covers all levels <strong>and</strong> applies as<br />

much to automation system <strong>and</strong> process peripherals as to operator<br />

<strong>and</strong> engineering systems, industrial communication networks<br />

or the SIMATIC IT framework as a link to information, coordination<br />

<strong>and</strong> planning tools for company management.<br />

However, this openness is not only characterized by the system<br />

architecture, horizontal/vertical integration <strong>and</strong> communication,<br />

but also by programming <strong>and</strong> data exchange interfaces for user<br />

programs as well as import/export functions for graphics, text<br />

<strong>and</strong> data, e.g. from the CAD/CAE world.<br />

SIMATIC PCS 7 can therefore also be combined with components<br />

from other vendors, <strong>and</strong> integrated in existing infrastructures.<br />

1/9


1/10<br />

Introduction<br />

<strong>Siemens</strong> ST PCS 7 · October 2004


<strong>System</strong>-neutral<br />

components<br />

2/2 <strong>System</strong> documentation<br />

2/3 Administration<br />

2/4 Software Update Service<br />

2/5 ES/OS/BATCH/IT basic devices<br />

2/5 Introduction<br />

2/6 Basic hardware<br />

2/10 Multi-VGA graphic cards<br />

2/11 Operating devices/monitors<br />

2/12 Operating system<br />

<strong>Siemens</strong> ST PCS 7 · October 2004


<strong>System</strong>-neutral components<br />

2 <strong>System</strong> documentation<br />

■ Overview<br />

Complete documentation for the SIMATIC PCS 7 process control<br />

system is available on CD-ROM. The documentation comes in<br />

3 languages (German/English/French) <strong>and</strong> includes all essential<br />

manuals: from system-wide documentation to individual descriptions<br />

of engineering tools, distributed I/Os, automation systems,<br />

operator systems <strong>and</strong> communication components. Getting<br />

Started items with sample projects are available by way of<br />

practical introduction.<br />

A separate programming guide for creating driver blocks is also<br />

available. This programming guide helps the advanced<br />

SIMATIC PCS 7 user to create system-conform driver blocks,<br />

which can be placed like st<strong>and</strong>ard components on system plans<br />

<strong>and</strong> automatically parameterized <strong>and</strong> configured in HW Config.<br />

In addition there is a multilingual S7 Manual Collection, which includes<br />

manuals for SIMATIC S7-200/300/400, SIMATIC C7, the<br />

LOGO! logic module, SIMATIC DP, SIMATIC PC, SIMATIC programming<br />

units, STEP 7, <strong>Engineering</strong> Software, Runtime Software,<br />

SIMATIC PCS 7, SIMATIC HMI <strong>and</strong> SIMATIC NET. Comprehensive<br />

documentation is thus available for all SIMATIC S7<br />

components used in context with SIMATIC PCS 7.<br />

The TELEPERM M Manual Collection is a bilingual (German <strong>and</strong><br />

English) collection of TELEPERM M manuals on CD-ROM. It replaces<br />

the complete documentation for the SIMATIC PCS 7 with<br />

all the relevant manuals for TELEPERM M migration.<br />

■ More information<br />

The "SIMATIC Technical Documentation Guide" on the Internet<br />

directs you straight to the technical documentation available for<br />

the various SIMATIC products <strong>and</strong> systems in the languages<br />

German, English, French, Italian <strong>and</strong> Spanish.<br />

Additional information is available in the Internet under:<br />

http://www.siemens.com/simatic-docu<br />

2/2<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

SIMATIC PCS 7<br />

Documentation CD<br />

SIMATIC PCS 7 documentation<br />

on CD-ROM, trilingual (German,<br />

English, French)<br />

Contents include:<br />

General documentation for<br />

SIMATIC PCS 7, e.g.<br />

- What’s new in PCS 7 V6.0<br />

- Outline description of SIMATIC<br />

PCS 7<br />

- Getting Started with PCS 7<br />

First Contact<br />

Part 1 – Basic Functions<br />

Part 2 – Rational <strong>Engineering</strong><br />

- ES Configuration Manual<br />

- OS Configuration Manual<br />

- Fault-Tolerant Process Control<br />

<strong>System</strong>s<br />

- PC Configuration <strong>and</strong> Authorization<br />

- 10 ms Time Stamp<br />

- Service Support <strong>and</strong> Diagnostics<br />

- PCS 7 Block Library<br />

Distributed I/Os<br />

- ET 200M<br />

- ET 200S<br />

- ET 200iS<br />

SIMATIC Operator <strong>System</strong> –<br />

Basic Process Control<br />

SIMATIC PDM<br />

SIMATIC <strong>Engineering</strong> Tools<br />

(STEP 7, CFC, SFC, S7-SCL,<br />

DOCPRO, BATCH, @PCS 7)<br />

Communication<br />

- S7-300 Communication<br />

- General Communication with<br />

SIMATIC<br />

- Bus Links<br />

- Couplers<br />

- SIMATIC NET Manuals<br />

SIMATIC Controls (<strong>Automation</strong><br />

<strong>System</strong>s)<br />

- S7-300, S7-400 Module Data<br />

- S7-300 Central Modules<br />

- S7-400H Fault-Tolerant <strong>System</strong>s<br />

- S7-400F/FH Failsafe <strong>System</strong>s<br />

6ES7 650-0XX06-8YX8 D)<br />

SIMATIC PCS 7 Programming<br />

Instructions for Creating Driver<br />

Blocks<br />

for SIMATIC PCS 7 V6.0 <strong>and</strong> V5.2,<br />

in Acrobat Reader Format (PDF)<br />

on CD-ROM, German/English<br />

SIMATIC S7 Manuals<br />

6ES7 653-1XD06-8YX8<br />

S7 Manual Collection<br />

Electronic manuals on CD, in<br />

5 languages (German, English,<br />

French, Italian, Spanish)<br />

6ES7 998-8XC01-8YE0 C)<br />

S7 Manual Collection - Maintenance<br />

Service for 1 Year<br />

Scope of supply: Current CD<br />

"S7 Manual Collection" <strong>and</strong> the<br />

three subsequent updates<br />

TELEPERM M Migration<br />

Manuals<br />

6ES7 998-8XC01-8YE2 C)<br />

TELEPERM M Manual Collection<br />

Electronic manuals on CD-ROM,<br />

bilingual (German, English)<br />

6DL5 900-8AX03-8YX8 C)<br />

C) Subject to export regulations: AL: N, ECCN: EAR99S<br />

D) Subject to export regulations: AL: N, ECCN: 5D992B1


■ Overview<br />

<strong>System</strong>-neutral components<br />

SIMATIC Electronic Signature<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

Administration<br />

Central user management, access control <strong>and</strong> electronic<br />

signature<br />

The SIMATIC Electronic Signature ensures that operations cannot<br />

be performed until enabled by previously assigned Windows<br />

users/user groups. Users/user groups are assigned to the operations<br />

in the respective application. The SIMATIC Electronic Signature<br />

has to be installed on all clients/single stations of the plant<br />

SIMATIC Logon offers central user administration with security that access this application.<br />

<strong>and</strong> access control based on Windows 2000/XP <strong>and</strong> Windows At the moment this function is implemented as a system function<br />

2003 Server for the SIMATIC PCS 7 system components as well only on SIMATIC BATCH. However, the Electronic Signature can<br />

as non-SIMATIC components connected through an interface. It be used on any products in the specific applications.<br />

can be used to fulfill the validation requirements of 21 CFR<br />

Part 11. An electronic signature function can also be used in ■ Selection <strong>and</strong> Ordering Data Order No.<br />

conjunction with SIMATIC Logon.<br />

SIMATIC Logon Admin Tool 6ES7 658-7AX21-2YB5 C)<br />

The optional Chipcard Reader can be used for access control in Floating license for 1 user<br />

addition to the keyboard. It is also possible, however, to connect<br />

other logon devices with their corresponding drivers, e.g. a Fingerprint<br />

Mouse.<br />

<strong>Engineering</strong> software on CD-ROM<br />

(German, English, French, Spanish,<br />

Italian) <strong>and</strong> authorization diskette<br />

■ Function<br />

SIMATIC Logon Service<br />

Single license for 1 installation<br />

6ES7 658-7BX21-2YA0 C)<br />

SIMATIC Logon Admin Tool<br />

Runtime software on CD-ROM<br />

(German, English, French, Span-<br />

Using the SIMATIC Logon Admin Tool it is possible to assign the<br />

roles defined in the SIMATIC PCS 7 applications (e.g. <strong>Automation</strong><br />

License Manager <strong>and</strong> SIMATIC BATCH) to the Windows users/user<br />

groups. Administrators with the necessary Windows administrator<br />

privileges can also use the SIMATIC Logon Admin<br />

Tool to edit Windows users <strong>and</strong> user groups.<br />

ish, Italian) <strong>and</strong> authorization diskette<br />

SIMATIC Electronic Signature<br />

Single license for 1 installation<br />

Runtime software on CD-ROM<br />

(German, English, French, Spanish,<br />

Italian) <strong>and</strong> authorization dis-<br />

6ES7 658-7CX21-2YB0 C)<br />

The SIMATIC Logon Admin Tool is required once per plant (floatketteing<br />

license).<br />

Option<br />

SIMATIC Logon Service<br />

Chipcard reader<br />

Chipcard reader as desktop ver-<br />

6ES7 652-0XX01-1XC0<br />

The login dialog of the SIMATIC Logon Service is activated when<br />

an application is started which is managed by SIMATIC Logon.<br />

The user receives his specific privileges after making the login,<br />

password <strong>and</strong> domain entries. The SIMATIC Logon Service dialog<br />

for logoff, user change or password edit can be called in the<br />

applications.. The SIMATIC Logon Service is required on all clients/single<br />

stations that access applications for which SIMATIC<br />

sion, V.24 connection, PS/2 power<br />

supply with 1.8 m cable, instruction<br />

manual<br />

Chipcard<br />

Chipcard for chipcard reader;<br />

1 card required per user;<br />

package with 10 chipcards<br />

6ES7 652-0XX05-1XD1<br />

Logon is used for access protection.<br />

C) Subject to export regulations: AL: N, ECCN: EAR99S<br />

■ Options<br />

Access security by means of chipcard reader<br />

A chipcard reader can be used to check a person’s authorization<br />

to access <strong>and</strong> operate a single station or a client. This method of<br />

access security uses the chipcard as a "key" to the operator terminals.<br />

Operations are only allowed when the card is actually inserted<br />

in the reader.<br />

The unmistakable identification of access rights is required in<br />

particular for plants which have to meet validation requirements.<br />

The chipcard reader is compliant with EN 55022 Class B <strong>and</strong><br />

EN 50082-1 st<strong>and</strong>ards.<br />

The reader is connected to a serial interface (COM1 or COM2)<br />

of the operator station.<br />

2/3<br />

2


<strong>System</strong>-neutral components<br />

2 Software Update Service<br />

■ Overview<br />

<strong>Siemens</strong> offers a SIMATIC PCS 7 Software Update Service. At a<br />

charge this subscription will automatically provide you with all<br />

ServicePacks issued within a year for the SIMATIC PCS 7 software<br />

products listed in the confirmation of order / software product<br />

certificate. Delivery is to the address entered in the order.<br />

The subscription is automatically extended for a further year unless<br />

canceled no later than 3 months prior to expiration.<br />

2/4<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

SIMATIC PCS 7 Software<br />

Update Service<br />

Subscription for 1 year with automatic<br />

extension; Requirements:<br />

current software version<br />

6ES7 658-4XX00-0YL0 D)<br />

D) Subject to export regulations: AL: N, ECCN: 5D992B1


■ Overview<br />

For engineering systems (ES), operator systems (OS) <strong>and</strong><br />

SIMATIC BATCH <strong>and</strong> SIMATIC Route Control we provide a range<br />

of modern, powerful basic devices that can also be used for<br />

connecting SIMATIC PCS 7 to the IT world. These basic devices<br />

can be exp<strong>and</strong>ed for system-specific purposes, are already optimized<br />

for use as single stations, clients or servers, <strong>and</strong> come<br />

equipped with the corresponding multi-lingual version of the operating<br />

systems Microsoft Windows 2000 (German, English,<br />

French, Italian <strong>and</strong> Spanish).<br />

The basic hardware (basic PC unit) can be combined with the<br />

color monitors recommended for SIMATIC PCS 7 in the catalog<br />

"PC-based <strong>Automation</strong>" to suit the operating environment <strong>and</strong><br />

the customer’s requirements.<br />

The system test confirms that the system software of the<br />

SIMATIC PCS 7 process control system can be run on the basic<br />

hardware offered in this catalog. <strong>Siemens</strong> guarantees the compatibility<br />

of hardware <strong>and</strong> software for system configurations<br />

based on components in this catalog.<br />

The use of basic software that is not offered in this catalog is at<br />

the user’s own risk <strong>and</strong> does not qualify for free support in the<br />

event of any compatibility problems.<br />

<strong>System</strong>-neutral components<br />

ES/OS/BATCH/IT basic devices<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

Introduction<br />

Minimum features of basic devices for ES, OS <strong>and</strong><br />

SIMATIC BATCH<br />

Programming device or personal computer with:<br />

- Pentium 4 processor or higher<br />

- min. 512 Mbyte RAM<br />

- min. 40 Gbyte hard disk memory<br />

Recommended features:<br />

- Programming device or personal computer with:<br />

- Pentium 4 processor with 2 GHz <strong>and</strong> higher<br />

- 1 Gbyte RAM für server/single stations, 512 Mbyte for clients<br />

- min. 60 Gbyte hard disk memory<br />

graphics card <strong>and</strong> monitor with 1280 x 1024 resolution<br />

(min. 1024 x 768)<br />

2/5<br />

2


<strong>System</strong>-neutral components<br />

ES/OS/BATCH/IT basic devices<br />

2 Basic hardware<br />

■ Overview<br />

The basic devices available for engineering systems, operator<br />

systems, SIMATIC BATCH <strong>and</strong> SIMATIC Route Control are<br />

based on a SIMATIC Rack PC in 19“ design, which is certified<br />

with the CE marking for use in industrial <strong>and</strong> office environments.<br />

This industrial PC meets the specific requirements of the process<br />

instrumentation <strong>and</strong> control system, <strong>and</strong> has a powerful innovative<br />

Intel PC architecture. Its service-friendly all-metal housing<br />

is mechanically robust, electromagnetically resistant, <strong>and</strong><br />

specially protected from dust by filters <strong>and</strong> pressurized cooling.<br />

Reliable 24-hour continuous operation at ambient temperatures<br />

between 5 <strong>and</strong> 40°C is made possible by the use of high-grade<br />

components with high MTBF values <strong>and</strong> monitoring functions for<br />

the inner housing temperature, fan <strong>and</strong> program execution.<br />

Specially optimized versions of the st<strong>and</strong>ard device are available<br />

for operation as single stations, servers or clients. The operating<br />

system <strong>and</strong> SIMATIC PCS 7 software are delivered in<br />

preinstalled form.<br />

Single stations <strong>and</strong> servers can be connected in two ways to the<br />

Industrial Ethernet bus:<br />

through a CP 1613 communications processor for communication<br />

with max. 64 automation systems (incl. redundant systems)<br />

or<br />

through a simple LAN card (Basic Communication Ethernet for<br />

communication with max. 8 non-redundant automation systems).<br />

A FastEthernet RJ45 port is already on board in all basic devices<br />

<strong>and</strong> can be used for connecting to an OS LAN (terminal bus).<br />

2/6<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

■ Design<br />

The SIMATIC Rack PC, used as the basic device for engineering<br />

systems, operator systems, SIMATIC BATCH <strong>and</strong> SIMATIC<br />

Route Control, can be installed in both a vertical <strong>and</strong> a horizontal<br />

arrangement. It has a robust <strong>and</strong> service-friendly, flush-mounting<br />

metal housing for 19" racks (4 HE) <strong>and</strong> comes with the following<br />

features:<br />

Pentium 4 motherboard with future-oriented Intel architecture<br />

based on an Intel 865G chip set<br />

Powerful AGP graphics with Dynamic Video Memory, sound<br />

(Line In, Line Out, Mic.) <strong>and</strong> FastEthernet RJ45 port integrated<br />

on board<br />

Expansion reserves provided by a total of 6 PCI slots<br />

6 slots for drives:<br />

- 3x 5.25“ slots on the front (1 occupied by DVD-ROM on client<br />

<strong>and</strong> server or by DVD±RW on single station);<br />

- 2x 3.5" slots on the inside (occupied by 1 hard disk on the<br />

client, <strong>and</strong> 2 hard disks on the server <strong>and</strong> single station)<br />

Enhanced system availability through RAID 1 with 2 EIDE hard<br />

disks on the server <strong>and</strong> single station<br />

Second serial interface for server available (COM 2)<br />

4 USB 2.0 interfaces on the back<br />

High electromagnetic compatibility (CE-certified for industrial<br />

<strong>and</strong> office environments)<br />

Dust protection by means of pressurized ventilation in conjunction<br />

with a front fan <strong>and</strong> a dust filter<br />

PC front complies with IP30 degree of protection when the<br />

front door is closed<br />

Front door can be locked to prevent unauthorized access to<br />

removable media, control elements <strong>and</strong> interfaces located at<br />

the front<br />

Easy <strong>and</strong> fast installation <strong>and</strong> maintenance of PC components:<br />

access to the front drives through a hinged front door;<br />

only 3 screws to open the device<br />

3 LED indicators on the front of the PC visualize the operating<br />

status: Power (activated), HD (access to hard disk), Status<br />

(monitoring the fan / temperature)<br />

Prepared for easy mounting with telescopic rails<br />

Easy to remove fixing bracket with h<strong>and</strong>les<br />

Card hold-down device to secure PC modules during transportation<br />

<strong>and</strong> to protect them from vibration <strong>and</strong> shock<br />

Power supply unit with temperature-controlled fan<br />

Power connector lock for the power supply cable<br />

The operating system <strong>and</strong> SIMATIC PCS 7 software are preinstalled<br />

on the basic devices. A restore DVD is supplied for<br />

quickly restoring the original status if required.


<strong>System</strong>-neutral components<br />

ES/OS/BATCH/IT basic devices<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

Basic hardware<br />

■ Technical specifications<br />

Interface modules/interfaces<br />

Basic hardware for single stations, servers <strong>and</strong> clients<br />

OS-LAN interface module 10/100/1000 Mbit/s (RJ45<br />

on board)<br />

Packaging 19" rack, 4 HE, for horizontal <strong>and</strong><br />

vertical installation, prepared for<br />

easy mounting with telescopic<br />

Plant bus interface module (single<br />

station/server)<br />

rails,<br />

IL 40 S V2 BCE FastEthernet RJ45 (PCI card)<br />

19" fixing bracket fixture with h<strong>and</strong>le,<br />

easy to remove<br />

IL 40 S V2 IE CP 1613 communications processor<br />

with licence<br />

CPU<br />

Interfaces<br />

Processor base<br />

Processor<br />

Front Side Bus (FSB)<br />

Second Level Cache<br />

mPGA478<br />

Intel Pentium 4, 2.8 GHz <strong>and</strong><br />

higher<br />

800 MHz<br />

USB<br />

Serial<br />

4 x at rear (high current),<br />

Hi-Speed USB 2.0<br />

Server: 1 x COM1 <strong>and</strong> 1 x COM2<br />

(each V.24)<br />

512 Kbyte<br />

Single station/client: 1 x COM1<br />

Main memory<br />

(V.24)<br />

Type Dual/Single Channel DDR 400 Parallel 1 x LPT1 (25-pin, EPP <strong>and</strong> ECP)<br />

SDRAM (PC 3200)<br />

Audio 1 x Line In; 1 x Line Out;<br />

Maximum configuration 4 memory bases in total (exp<strong>and</strong>-<br />

1 x Micro In<br />

able to 4 Gbyte)<br />

VGA 1 x<br />

St<strong>and</strong>ard configuration Single station/server: 1 Gbyte (2 x<br />

512 Mbyte)<br />

Keyboard 1 x PS/2<br />

Client: 512 Mbyte (2 x 256 Mbyte)<br />

Mouse 1 x PS/2<br />

Motherboard slots 6 x PCI (long), 1 x AGP 8x<br />

Monitoring functions<br />

Slots for drives<br />

Temperature Overshooting of the permissible<br />

operating temperature<br />

On the front 1 x 3.5“ (occupied by diskette<br />

drive)<br />

Fan Speed monitoring<br />

3 x 5.25“ (1 occupied by DVD-<br />

ROM on client <strong>and</strong> server or by<br />

DVD±RW on single station)<br />

Watchdog Monitoring the program flow<br />

(monitoring time can be parameterized<br />

per software)<br />

On the inside 2 x 3.5“ (2 occupied by HDD on<br />

server/single station; 1 occupied<br />

by HDD on client)<br />

Front LEDs Power (PC activated)<br />

HD (access to hard disk)<br />

Status (monitoring the fan / tem-<br />

Hard disk memory<br />

perature)<br />

Single station/server EIDE-RAID 1 (mirror) with two<br />

Ambient conditions<br />

120 Gbyte hard disks, 7200 rpm Degree of protection according to IP20;<br />

Client 80 Gbyte EIDE hard disk,<br />

EN 60529<br />

front IP30 (with closed front door)<br />

7200 rpm<br />

Protection class Protection class I compliant with<br />

Interchangeable drives Diskette drive<br />

IEC 61140<br />

Single station: DVD writer<br />

(DVD±RW), 16/8/4x (DVD media),<br />

48/24/48x (CD media), incl.<br />

Ambient temperature during operation<br />

5...40 °C for full expansion<br />

Note: Restrictions in use of<br />

DVD-ROM/CD-RW or DVD±RW<br />

burning software<br />

Humidity 5...80% at 25 °C (no condensa-<br />

Server/Client: DVD-ROM (16x<br />

tion)<br />

48x)<br />

Vibration during operation compli- 20...200 Hz: 2 m/s2 (approx.<br />

Graphics card 2D/3D graphics controller on ant with IEC 60068-2-6<br />

0.2 g)<br />

board, integrated in Intel 865G<br />

Note: Restrictions in use of<br />

chip set, on AGP bus with<br />

DVD-ROM/CD-RW or DVD±RW<br />

Dynamic Video Memory, 1600 x<br />

<strong>and</strong> interchangeable frames<br />

1200 pixel at 100 Hz image<br />

refresh rate <strong>and</strong> 64 k colors<br />

Shock load during operation compliant<br />

with IEC 60068-2-27<br />

9.8 m/s2, 20 ms (approx. 1.0 g)<br />

Note: Restrictions in use of<br />

Mouse Optical mouse<br />

DVD-ROM/CD-RW or DVD±RW<br />

Power supply<br />

Operating system<br />

300 W 120/230 V AC, 50/60 Hz,<br />

autorange<br />

<strong>and</strong> interchangeable frames<br />

Single station/client Microsoft Windows 2000 Professional<br />

MUI, preinstalled <strong>and</strong> on<br />

restore DVD,<br />

switch-selectable: German,<br />

English, French, Italian, Spanish<br />

Server Microsoft Windows 2000 Professional<br />

MUI, incl. 5 CAL (Client<br />

Access Licences), preinstalled<br />

<strong>and</strong> on restore DVD,<br />

switch-selectable: German,<br />

English, French, Italian, Spanish<br />

2/7<br />

2


2<br />

<strong>System</strong>-neutral components<br />

ES/OS/BATCH/IT basic devices<br />

Basic hardware<br />

Electromagnetic compatibility (EMC)<br />

Emitted interference EN 55022 Class B, FCC Class A<br />

Immunity to conducted interference ± 2 kV (IEC 61000-4-4, burst)<br />

on the supply lines<br />

± 1 kV (IEC 61000-4-5, surge<br />

symm.)<br />

± 2 kV (IEC 61000-4-5, surge<br />

unsymm.)<br />

Immunity to interference on signal ± 1 kV (IEC 61000-4-4, burst,<br />

lines<br />

length 30 m)<br />

± 2 kV (IEC 61000-4-5, surge<br />

unsymm., length > 30 m)<br />

Immunity to static discharge ± 4 kV, contact discharge<br />

(IEC 61000-4-2)<br />

± 8 kV, air discharge<br />

(IEC 61000-4-2)<br />

Immunity to high-frequency immis- 10 V/m 80% AM; 80 MHz to<br />

sion<br />

1 GHz (IEC 61000-4-3);<br />

10 V/m 50% ED; 900 MHz <strong>and</strong><br />

1.89 GHz (IEC 61000-4-3)<br />

10 V, 9 kHz to 80 MHz<br />

(IEC 61000-4-6)<br />

Immunity to magnetic fields 30 A/m, 50/60 Hz (IEC 61000-4-8)<br />

Approvals<br />

Safety directives IEC 60950-1; UL 60950; CSA<br />

Approvals UL 60950, cULus<br />

CE marking Use in the office <strong>and</strong> industrial<br />

sectors<br />

Emitted intereference: EN 61000-<br />

6-3<br />

Immunity to interference:<br />

EN 61000-6-2<br />

Dimensions <strong>and</strong> weights<br />

Overall dimensions in mm<br />

430 x 177 x 444<br />

(WxHxD)<br />

Weight approx. 19 kg<br />

2/8<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

■ Accessories<br />

Keyboards<br />

The PCS 7 basic devices for ES/OS/BATCH/IT are supplied with<br />

a keyboard. The TK 200 keyboard with PS/2 connection is available<br />

as an additional <strong>and</strong> expansion component. It is particularly<br />

well suited for process operation with SIMATIC PCS 7 <strong>and</strong><br />

comes with German or international key assignment.<br />

Image & Partition Creator<br />

"SIMATIC PC/PG Image & Partition Creator" is available as an optional<br />

utility software package for creating regular backups of a<br />

hard disk’s contents <strong>and</strong> for quickly restoring a saved software<br />

status. Existing software installations are easily duplicated on<br />

devices with the same features <strong>and</strong> the same purpose. It is<br />

therefore easier <strong>and</strong> faster to carry out plant expansions <strong>and</strong> to<br />

completely replace a basic device during servicing. The tool can<br />

also be used to create, change <strong>and</strong> delete hard disk partitions.<br />

SIMATIC PC/PG Image & Partition Creator supports:<br />

the saving of hard disk images on a second hard disk, an internal<br />

CD-RW/DVD±RW or an external hard disk drive connected<br />

by USB, <strong>and</strong> the restoring of existing images on the<br />

hard disk<br />

the menu-prompted creation of a LAN connection to a server<br />

drive or to a PC that is directly connected by crosslink cable


■ Selection <strong>and</strong> Ordering Data<br />

Single station<br />

SIMATIC PC in rack of 19“ design,<br />

Pentium 4 with 2.8 GHz <strong>and</strong> more,<br />

1 Gbyte RAM (2 x 512 Mbyte),<br />

sound, EIDE-RAID 1 with 2 hard<br />

disks of 120 Gbyte, graphics controller<br />

on board with Dynamic<br />

Video Memory, DVD±RW IDE,<br />

optical mouse,<br />

FastEthernet RJ45 on board for<br />

connection to OS-LAN,<br />

without monitor, keyboard <strong>and</strong><br />

printer,<br />

Windows 2000 Professional MUI<br />

(German, English, French, Italian,<br />

Spanish); SIMATIC PCS 7 preinstalled<br />

<strong>and</strong> on restore DVD<br />

Order No.<br />

PCS 7 ES/OS IL 40 S V2 BCE<br />

Connection to plant bus through<br />

Basic Communication Ethernet<br />

(BCE) with FastEthernet RJ45<br />

network card (PCI card)<br />

6ES7 650-0GC06-0YX0 D)<br />

PCS 7 ES/OS IL 40 S V2 IE<br />

Connection to plant bus through<br />

Industrial Ethernet with CP 1613<br />

communications processor<br />

Server<br />

SIMATIC PC in rack of 19“ design,<br />

Pentium 4 with 2.8 GHz <strong>and</strong> more,<br />

1 Gbyte RAM (2 x 512 Mbyte),<br />

sound, EIDE-RAID 1 with 2 hard<br />

disks of 120 Gbyte, graphics controller<br />

on board with Dynamic<br />

Video Memory, DVD-ROM IDE,<br />

optical mouse,<br />

FastEthernet RJ45 on board for<br />

connection to OS-LAN,<br />

without monitor, keyboard <strong>and</strong><br />

printer,<br />

Windows 2000 Server MUI (German,<br />

English, French, Italian,<br />

Spanish); SIMATIC PCS 7 preinstalled<br />

<strong>and</strong> on restore DVD<br />

6ES7 650-0GC16-0YX0 D)<br />

PCS 7 OS Server IL 40 S V2<br />

BCE<br />

Connection to plant bus through<br />

Basic Communication Ethernet<br />

(BCE) with FastEthernet RJ45<br />

network card (PCI card)<br />

6ES7 650-0GE06-0YX0 D)<br />

PCS 7 OS Server IL 40 S V2 IE<br />

Connection to plant bus through<br />

Industrial Ethernet with CP 1613<br />

communications processor<br />

Client<br />

6ES7 650-0GE16-0YX0 D)<br />

PCS 7 OS Client IL 40 S V2<br />

SIMATIC PC in rack of 19“ design,<br />

Pentium 4 with 2.8 GHz <strong>and</strong> more,<br />

512 Mbyte RAM (2 x 256 Mbyte),<br />

sound, EIDE hard disk of<br />

80 Gbyte, graphics controller on<br />

board with Dynamic Video Memory,<br />

DVD-ROM IDE, optical<br />

mouse,<br />

FastEthernet RJ45 on board for<br />

connection to OS-LAN,<br />

without monitor, keyboard <strong>and</strong><br />

printer,<br />

Windows 2000 Professional MUI<br />

(German, English, French, Italian,<br />

Spanish); SIMATIC PCS 7 preinstalled<br />

<strong>and</strong> on restore DVD<br />

6ES7 650-0GD06-0YX0 D)<br />

<strong>System</strong>-neutral components<br />

ES/OS/BATCH/IT basic devices<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

Basic hardware<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

Additional <strong>and</strong> expansion components<br />

Utility software<br />

SIMATIC PC/PG Image & Partition<br />

Creator<br />

Software for creating hard disk<br />

images <strong>and</strong> for configurating hard<br />

disk partitions<br />

6ES7 648-6AA02-0YX0 B)<br />

Memory modules for exp<strong>and</strong>ing<br />

the main memory<br />

Memory expansion kit 512<br />

Mbyte (Dual Channel) for SI-<br />

MATIC Rack PC IL 40 S V2 (2 x<br />

256 Mbyte DDR SDRAM)<br />

Memory expansion kit 1 Gbyte<br />

(Dual Channel) for SIMATIC<br />

Rack PC IL 40 S V2 (2 x<br />

512 Mbyte DDR SDRAM)<br />

Memory expansion kit 2 Gbyte<br />

(Dual Channel) for SIMATIC<br />

Rack PC IL 40 S V2 (2 x 1 Gbyte<br />

DDR SDRAM)<br />

6ES7 648-2AD30-0FB0 B)<br />

6ES7 648-2AD40-0FB0 B)<br />

6ES7 648-2AD50-0FB0 B)<br />

TK 200 keyboard (PS/2 connection)<br />

German key assignment 6GF6 710-1AA<br />

International key assignment 6GF6 710-1BA<br />

SIMATIC PC keyboard (USB<br />

connection)<br />

International key assignment 6ES7 648-0CB00-0YA0<br />

3-m power cable for Rack PC 1)<br />

For Great Britain 6ES7 900-0BA00-0XA0<br />

For Switzerl<strong>and</strong> 6ES7 900-0CA00-0XA0<br />

For USA 6ES7 900-0DA00-0XA0<br />

For Italy 6ES7 900-0EA00-0XA0<br />

B) Subject to export regulations: AL: N, ECCN: EAR99H<br />

D) Subject to export regulations: AL: N, ECCN: 5D992B1<br />

1) The PCS 7 systems are delivered as st<strong>and</strong>ard with a "European power<br />

cable". The country-specific versions listed above are required for some<br />

countries.<br />

2/9<br />

2


<strong>System</strong>-neutral components<br />

ES/OS/BATCH/IT basic devices<br />

2 Multi-VGA graphic cards<br />

■ Overview<br />

The ES/OS/BATCH/IT basic devices available for SIMATIC<br />

PCS 7 are supplied as st<strong>and</strong>ard with a graphics interface for<br />

controlling a process monitor. The Multi-VGA graphics cards<br />

"2 Screens" <strong>and</strong> "4 Screens" are available for multichannel operation<br />

with 2 or as many as 4 process monitors.<br />

With a special Multi-VGA graphics card, the visualization of a<br />

project/subproject during engineering or of a plant/unit in process<br />

mode can be shared among as many as 4 process monitors<br />

per operator terminal using various views. These<br />

project/plant sections can all be operated using just one keyboard<br />

<strong>and</strong> one mouse. The efficiency, user-friendliness <strong>and</strong> ergonomics<br />

of engineering <strong>and</strong> process control can thus be<br />

greatly improved compared to the single-channel mode of operation.<br />

■ Technical specifications<br />

Multi-VGA graphics cards<br />

Memory 32 Mbyte DDRAM per output<br />

Graphics card "2 Screens" 2 x 32 Mbyte<br />

Graphics card "4 Screens" 4 x 32 Mbyte<br />

Clock frequency 360 MHz integrated RAMDAC<br />

Max. analog resolution per channel 2048 x 1536 at 24 bpp <strong>and</strong> 85 Hz<br />

Max. digital resolution per channel<br />

Electromagnetic compatibility<br />

(EMC)<br />

1280 x 1024<br />

(1600 x 1200 is possible if supported<br />

by TFT/LCD display)<br />

Emitted interference EN 55022 Class B<br />

Immunity to interference EN 50082<br />

Slot assignment in operator station 1 PCI slot<br />

2/10<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

Multi-VGA Graphics Card<br />

"2 Screens“<br />

for operating 2 process monitors<br />

on 1 station<br />

Type of delivery:<br />

Dual graphics card, driver CD,<br />

manual, 1 dual DVI cable for<br />

2 digital outputs, 2 adapters for<br />

VGA outputs<br />

6ES7 652-0XX03-1XE0 B)<br />

Multi-VGA Graphics Card<br />

"4 Screens“<br />

for operating 4 process monitors<br />

on 1 station<br />

Type of delivery:<br />

Quad graphics card, driver CD,<br />

manual, 2 dual DVI cables for<br />

4 digital outputs, 4 adapters for<br />

VGA outputs<br />

6ES7 652-0XX03-1XE1 B)<br />

B) Subject to export regulations: AL: N, ECCN: EAR99H


Detailed technical data can be found in<br />

the catalog "PC-based <strong>Automation</strong>" or<br />

the Mall/CA 01 at "<strong>Automation</strong> systems - Monitors, printers <strong>and</strong><br />

input devices for industry"<br />

<strong>System</strong>-neutral components<br />

ES/OS/BATCH/IT basic devices<br />

Operating devices/monitors<br />

■ Overview<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

Operating devices<br />

Process Monitors<br />

A mouse <strong>and</strong> keyboard are the st<strong>and</strong>ard operating devices (see<br />

Industrial Monitors<br />

in "Basic hardware"). Additional operating devices such as a fin- LCD Color Monitor SCD 1898-I<br />

gerprint mouse, trackball, Ex PC operator control unit <strong>and</strong><br />

TS-Mobic <strong>and</strong> be found in the ST PCS 7.A Add-on Catalog .<br />

46 cm (18“) picture diagonal,<br />

desktop model, line frequency<br />

Process monitors<br />

30...97 kHz, degree of protection<br />

IP20, power supply unit 230 V AC<br />

Depending on the ambient conditions we recommend the<br />

1.8 m cable 6AV8 101-2DA00-0BA0<br />

SCD 1898-I (LCD color) or SCM 2196-I (CRT color) industrial<br />

monitors as well as the SCM 2197 (CRT color) office monitor, all<br />

from <strong>Siemens</strong>.<br />

5 m cable<br />

10 m cable<br />

6AV8 101-2DA00-0DA0<br />

6AV8 101-2DA00-0FA0<br />

The CRT monitors provide a top-quality picture throughout their 20 m cable 6AV8 101-2DA00-0JA0<br />

long service life.<br />

SCM 2196-I CRT Color Monitor 6GF6 100-1BA<br />

Outst<strong>and</strong>ing characteristics of the SCD 1898-I LCD monitor include:<br />

7 Long service life<br />

54 cm (21“) picture diameter,<br />

desktop model 115/230 V AC,<br />

line frequency up to 96 kHz,<br />

degree of protection IP30,<br />

7 Clear, high-contrast <strong>and</strong> flicker-free picture<br />

with video cable (Sub-D, BNC)<br />

7 Exact picture geometry<br />

7 Small space requirement <strong>and</strong> low weight<br />

7 Low energy consumption <strong>and</strong> heat development<br />

7 High resistance to shock <strong>and</strong> vibration<br />

7 High electromagnetic compatibility<br />

P95 Supporting Foot for<br />

SCM 2196-I<br />

Office Monitors<br />

SCM 2197 CRT Color Monitor<br />

54 cm (21“), picture diagonal<br />

degree of protection IP20, with<br />

6GF6 180-1AH<br />

6GF6 100-1PC<br />

7 No X-radiation<br />

power connection cable <strong>and</strong><br />

video cable with 15-pin/3-row<br />

Monitors suitable for installing in desks, 19" racks or switchgear<br />

cabinets can be found in:<br />

the catalog "PC-based <strong>Automation</strong>" or<br />

the A&D Mall/CA 01 at "<strong>Automation</strong> systems - Monitors, printers<br />

<strong>and</strong> input devices for industry"<br />

■ Technical specifications<br />

Sub-D connector<br />

Monitors SCD 1898-I SCM 2196-I SCM 2197<br />

Monitor 18.1“ (45 cm) 21“ (54 cm) CRT 21“ (54 cm) CRT<br />

TFT color monitor,<br />

1280 x 1024<br />

pixels<br />

color monitor color monitor<br />

Line frequency<br />

30..0.97 kHz 30..00.96 kHz 30..00.96 kHz<br />

Image refresh<br />

rate<br />

50..00.100 Hz 50..000.120 Hz 50..000.160 Hz<br />

Dimensions<br />

(WxHxD) in<br />

mm<br />

465 x 444 x 91 499 x 480 x 520 504 x 508 x 492<br />

Degree of protection<br />

IP20 IP30 IP20<br />

Weight approx. 10 kg approx. 30.5 kg approx. 26 kg<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

2/11<br />

2


<strong>System</strong>-neutral components<br />

ES/OS/BATCH/IT basic devices<br />

2 Operating system<br />

■ Overview<br />

Operating system upgrade<br />

When the SIMATIC PCS 7 is updated to Version 6.0, the NT workstation/server<br />

on PCs with the Windows NT operating system<br />

has to be upgraded to Windows 2000.<br />

The necessary upgrade packages can be ordered as follows:<br />

By fax: +49 821 804 3006<br />

By e-mail: dominikus.besserer@fujitsu-siemens.com<br />

<strong>Siemens</strong> Ordering <strong>System</strong> (Org ID: 13000054)<br />

2/12<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

Upgrade from Windows NT<br />

Workstation to Windows 2000<br />

Professional operating system<br />

SB Windows 2000 Professional<br />

incl. SP4, German, pack of 3<br />

SB Windows 2000 Professional<br />

incl. SP4, German, pack of 1<br />

SB Windows 2000 Professional<br />

incl. SP4, English, pack of 3<br />

Operating system<br />

Windows 2000 Server<br />

SB Windows 2000 Server incl.<br />

SP4, German (for up to 5 clients)<br />

SB Windows 2000 Server incl.<br />

SP4, English (for up to 5 clients)<br />

5-client access license (CAL) for<br />

SB Windows 2000 Server, German<br />

5-client access license (CAL) for<br />

SB Windows 2000 Server, English<br />

MSO:B23-03883/KIT<br />

MSO:B23-03882/KIT<br />

MSO:B23-03877/KIT<br />

MSO:C11-03150/KIT<br />

MSO:C11-03148/KIT<br />

MSO:C78-00688/KIT<br />

MSO:C78-00686/KIT


SIMATIC PCS 7 BOX<br />

3/2 SIMATIC PCS 7 BOX<br />

<strong>Siemens</strong> ST PCS 7 · October 2004


3<br />

SIMATIC PCS 7 BOX<br />

SIMATIC PCS 7 BOX<br />

■ Overview<br />

SIMATIC PCS 7 BOX extends the product spectrum of SIMATIC<br />

PCS 7 by adding a cost-effective entrance-level product that<br />

unites SIMATIC PCS 7 functionality for automation, operation, visualization<br />

<strong>and</strong> engineering in one compact PC system. In conjunction<br />

with the distributed I/Os on the PROFIBUS, SIMATIC<br />

PCS 7 BOX represents a complete SIMATIC PCS 7 process control<br />

system.<br />

■ Application<br />

SIMATIC PCS 7 BOX can be used just as readily for small applications<br />

in production or self-contained subprocesses (Package<br />

Units) as for the automation of a laboratory or test center. As a<br />

fully fledged member of the SIMATIC PCS 7 range, SIMATIC<br />

PCS 7 BOX works with the st<strong>and</strong>ard SIMATIC PCS 7 system software,<br />

is scalable <strong>and</strong> can be exp<strong>and</strong>ed without disruption of<br />

compatibility. The quantity framework is limited to<br />

2000 POs/64 K variables.<br />

SIMATIC PCS 7 BOX can be operated in st<strong>and</strong>-alone mode as<br />

well as in a plant network. Operation in a plant network is intended<br />

only as a single-station system; SIMATIC PCS 7 BOX is<br />

not suitable for server operation.<br />

A plant created with SIMATIC PCS 7 BOX can be exp<strong>and</strong>ed at<br />

any time with additional SIMATIC PCS 7 hardware <strong>and</strong> software<br />

components. And SIMATIC PCS 7 BOX can be integrated just a<br />

easily in existing SIMATIC PCS 7 plants.<br />

However, SIMATIC PCS 7 BOX has not yet been released for<br />

batch process automation with SIMATIC BATCH.<br />

3/2<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

■ Design<br />

SIMATIC PCS 7 BOX in st<strong>and</strong>-alone operation<br />

SIMATIC PCS 7 BOX integrated in the SIMATIC PCS 7 plant network<br />

SIMATIC PCS 7 BOX is based on a Box PC 620 industrial PC with<br />

an installed CPU WinAC Slot 416 V3.4; this means that the often<br />

distributed PLS functionality for automation, operation, visualization<br />

<strong>and</strong> engineering can be brought together in a single system.<br />

SIMATIC PCS 7 BOX uses st<strong>and</strong>ard system software from SI-<br />

MATIC PCS 7 V6.0 Service Pack 3 or higher <strong>and</strong> is integrated in<br />

SIMATIC PCS 7 <strong>Engineering</strong> <strong>and</strong> in the PCS 7 Project Wizard.<br />

This ensures full compatibility with SIMATC PCS 7 V6.0.<br />

Using the CPU WinAC Slot 416 means that the automation program<br />

runs in the slot CPU fully independent of the industrial PC<br />

<strong>and</strong> the Windows operating system. The PC-independent power<br />

supply to the slot CPU is arranged through a separate power<br />

supply extension board. Software errors on the PC side have no<br />

effect on the slot CPU. Like voltage failures or rebooting the PC<br />

they have no impact on the execution of the automation program<br />

in the slot CPU.<br />

SIMATIC PCS 7 BOX can be configured by using either the engineering<br />

software integrated in the system or a central engineering<br />

system. OS modifications through the central engineering<br />

system are also possible online, but the online loading of OS<br />

modifications on the SIMATIC PCS 7 BOX is not yet possible.


SIMATIC PCS 7 BOX supports not only the distributed I/O devices<br />

of the ET 200 range with an extensive selection of cost-effective<br />

signal <strong>and</strong> function modules but also the connection of<br />

intelligent field/process devices on PROFIBUS PA. The process<br />

I/Os are connected through the two PROFIBUS DP ports of the<br />

slot CPU. As SIMATIC PDM can only access field devices on the<br />

PROFIBUS DP through the onboard communications processor<br />

CP 5611, an additional cross connection between the DP port<br />

<strong>and</strong> CP 5611 is required to use SIMATIC PDM . A plug required<br />

for this purpose is supplied with the SIMATIC PCS 7 BOX.<br />

Configuration modifications during operation (CiR) are not yet<br />

supported by the current CPU WinAC Slot 416. However, plans<br />

to include this functionality in future WinAC Slot CPUs are currently<br />

in the pipeline.<br />

In a plant network with other SIMATIC PCS 7 system components<br />

such as AS, OS, ES or BATCH <strong>and</strong> MES applications, bus<br />

communication is implemented through the Ethernet interface<br />

integrated in the SIMATIC PCS 7 BOX. An additional CP 1512 is<br />

required (see "Accessories") for connecting to the SIMATIC<br />

PCS 7 terminal bus (OS-LAN).<br />

SIMATIC PCS 7 BOX is available in the form of two product bundles:<br />

as a preinstalled SIMATIC PCS 7 complete system with AS, ES<br />

<strong>and</strong> OS functionality for up to 250 process objects (POs) / 8 K<br />

OS variables<br />

as a preinstalled SIMATIC PCS 7 runtime system with AS <strong>and</strong><br />

OS functionality for up to 250 process objects (POs) / 8 K OS<br />

variables<br />

These can be further exp<strong>and</strong>ed using the following add-on/expansion<br />

components (see also Chapter "ES/OS/Batch/IT basic<br />

devices" <strong>and</strong> the catalog "PC-based <strong>Automation</strong>"):<br />

SIMATIC PCS 7 Power Packs for up to 2,000 POs / 64 K OS<br />

variables<br />

SIMATIC PDM Package for PCS 7<br />

CP 1512 for connecting to the OS-LAN (SIMATIC PCS 7 terminal<br />

bus) of a SIMATIC PCS 7 plant network<br />

TK 200 st<strong>and</strong>ard keyboard<br />

Display <strong>and</strong> CRT monitors for office <strong>and</strong> industrial environments<br />

SITOP power supply 230 V AC / 24 V DC<br />

SITOP power DC-UPS module 15 A with RS 232 interface<br />

DC-UPS software for the further processing of signals sent<br />

from the DC-UPS module using the RS 232 interface on the PC<br />

(state visualization <strong>and</strong> the definition of reactions to different<br />

operating states of the DC-UPS module), can be used with<br />

Windows NT, 2000 <strong>and</strong> XP; freeware for downloading at<br />

http://www.siemens.com/sitop<br />

SITOP power battery module 24 V DC /20 A/7 Ah for DC-UPS<br />

module 15 A<br />

■ Technical specifications<br />

SIMATIC PCS 7 BOX<br />

SIMATIC PCS 7 BOX<br />

Industrial PC: SIMATIC Box PC 620<br />

CPU Intel Pentium III 1.26 GHz<br />

Main memory 1 Gbyte<br />

Second Level Cache 512 Kbyte<br />

Hard disk memory 80 Gbyte<br />

Diskette drive 1.44 Mbyte<br />

DVD-ROM/CD-RW Combo drive 8/8/24x<br />

Graphics UXGA LCD controller on AGP<br />

bus, 1280 x 1024 at 85 Hz<br />

Ethernet integrated Ethernet interface<br />

10/100 Mbit/s (RJ45)<br />

PROFIBUS DP 12 Mbit/s (floating, CP 5611-compatible)<br />

USB 2 terminals (high current)<br />

Expansions 1 CardBus slot for PCMCIA Typ III<br />

PC card<br />

Power supply 24 V DC<br />

Operating system Microsoft Windows 2000 Professional<br />

<strong>Automation</strong>: slot PLC module<br />

CPU WinAC Slot 416 V3.4<br />

Main memory 1.6 + 1.6 Mbyte (integrated)<br />

Loading memory 256 Kbyte<br />

Memory card 2 Mbyte RAM (installed)<br />

Processing times Binary comm<strong>and</strong>: 0.08 µs,<br />

IEEE floating point: 0.48 µs<br />

PROFIBUS DP PROFIBUS DP <strong>and</strong><br />

PROFIBUS DP/MPI interface<br />

onboard<br />

Connectable distributed I/Os ET 200M, ET 200iS, ET 200S,<br />

PROFIBUS DP st<strong>and</strong>ard slaves,<br />

PROFIBUS PA devices (using<br />

DP/PA link or DP-PA coupler)<br />

Dimensions PCI plug-in card (3/4 long)<br />

Power supply Power supply extension board<br />

independent of PC;<br />

external power supply 24 V DC<br />

<strong>and</strong> battery buffer<br />

Operation <strong>and</strong> visualization<br />

Software PCS 7 OS Software Single Station<br />

V6.0 (preinstalled)<br />

Licenses 250 POs/RT 8K variables<br />

(extendable to 2000 POs/RT 64K<br />

per PowerPack)<br />

<strong>Engineering</strong><br />

Software PCS 7 <strong>Engineering</strong> Software V6.0<br />

(preinstalled)<br />

Licenses AS/OS for 250 POs/RC 8K<br />

(extendable to 2000 POs/RC 64K<br />

per Power Pack)<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

3/3<br />

3


3<br />

SIMATIC PCS 7 BOX<br />

SIMATIC PCS 7 BOX<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

SIMATIC PCS 7 BOX<br />

Complete system (ES, OS <strong>and</strong><br />

AS), assembled <strong>and</strong> preinstalled,<br />

comprising:<br />

SIMATIC Box PC 620, 24 V DC,<br />

with WinAC Slot 416<br />

Memory card 2 Mbyte<br />

WinAC power supply extension<br />

board<br />

Backup battery<br />

Mouse<br />

PCS 7 <strong>Engineering</strong> Software<br />

V6.0 for AS/OS, 250 POs/RC 8K,<br />

trilingual (German, English,<br />

French)<br />

PCS 7 Library Blocks V6.0, Runtime<br />

License<br />

trilingual (German, English,<br />

French)<br />

6ES7 650-2HA06-0YX0 G)<br />

SIMATIC PCS 7 BOX<br />

Runtime system (OS <strong>and</strong> AS),<br />

assembled <strong>and</strong> preinstalled,<br />

comprising:<br />

SIMATIC Box PC 620, 24 V DC,<br />

with WinAC Slot 416<br />

Memory card 2 Mbyte<br />

WinAC power supply extension<br />

board<br />

Backup battery<br />

Mouse<br />

PCS 7 OS Software Single Station<br />

V6.0, 250 POs/RT 8K,<br />

trilingual (German, English,<br />

French)<br />

PCS 7 Library Blocks V6.0, Runtime<br />

License<br />

trilingual (German, English,<br />

French)<br />

Additional <strong>and</strong> Expansion Components<br />

SIMATIC PCS 7 Power Packs<br />

6ES7 650-2HB06-0YX0 G)<br />

PCS 7 <strong>Engineering</strong> Power Pack<br />

AS/OS<br />

for exp<strong>and</strong>ing the engineering<br />

software for AS/OS<br />

from 250 POs/RC 8 K to<br />

2,000 POs/RC 64 K<br />

Type of delivery: Certificate of license<br />

<strong>and</strong> authorization diskette<br />

6ES7 658-5AB06-0YD0<br />

PCS 7 OS Software Single Station<br />

Power Pack V6.0<br />

for exp<strong>and</strong>ing the OS Software<br />

Single Station<br />

from 250 POs/RC 8 K to<br />

2,000 POs/RC 64 K<br />

Type of delivery: Certificate of license<br />

<strong>and</strong> authorization diskette<br />

6ES7 658-2AB06-0YD0<br />

3/4<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

■ Selection <strong>and</strong> Ordering Data<br />

SIMATIC PDM<br />

Order No.<br />

PDM Starter Package V5.2 for<br />

SIMATIC PCS 7<br />

Preferred version for<br />

SIMATIC PCS 7, in 5 languages<br />

(German, English, French, Italian<br />

<strong>and</strong> Spanish), with:<br />

Basic software for SIMATIC PDM<br />

(incl. communication through<br />

PROFIBUS DP/PA, HART modem<br />

<strong>and</strong> RS 232)<br />

Integration in STEP 7 / PCS 7<br />

Routing through S7-400<br />

128 TAGs<br />

SIMATIC PDM documentation<br />

TAG options in form of Power<br />

Packs <strong>and</strong> supplementary software,<br />

see the chapter "ES Software<br />

SIMATIC PDM", section<br />

"PDM Package for PCS 7"<br />

6ES7 658-3PX05-0YC0 C)<br />

Connection to OS-LAN<br />

(SIMATIC PCS 7 terminal bus)<br />

CP 1512<br />

6GK1 151-2AA00<br />

PC card for CardBus slot, for connecting<br />

the SIMATIC PCS 7 BOX<br />

to Industrial Ethernet<br />

(10/100 Mbit/s), incl. RJ45 connection<br />

TK 200 keyboard (PS/2 connection)<br />

German key assignment 6GF6 710-1AA<br />

International key assignment 6GF6 710-1BA<br />

SIMATIC PC keyboard<br />

(USB connection)<br />

International key assignment 6ES7 648-0CB00-0YA0<br />

Power supply 230 V AC /<br />

24 V DC<br />

Power supply SITOP power 10 6EP1 334-2AA00<br />

stabilized load power supply, industry<br />

version,<br />

input: 120/230 V AC, output:<br />

24 V DC/10 A<br />

SITOP power DC-UPS module<br />

24 V DC/15 A 1)<br />

6EP 1931-2EC31<br />

with RS 232 interface <strong>and</strong><br />

charging unit for 24 V lead-acid<br />

battery<br />

input: 24 V DC/16 A, output 24 V<br />

DC/15 A<br />

SITOP power battery module 6EP1 935-6ME21<br />

24 V DC /20 A/7 Ah<br />

for DC-UPS module 15 A<br />

1) Add-on DC-UPS software<br />

(can be used with Windows<br />

NT, 2000 <strong>and</strong> XP) for further<br />

processing of signals sent<br />

from the DC-UPS module<br />

using the RS 232 interface<br />

on the PC; avaialable as<br />

freeware for downloading at<br />

http://www.siemens.de/sitop<br />

C) Subject to export regulations: AL: N, ECCN: EAR99S<br />

G) Subject to export regulations: AL: N, ECCN: 5D002ENC3


<strong>Engineering</strong> <strong>System</strong><br />

4/2 Introduction<br />

4/3 ES hardware<br />

4/4 ES software<br />

4/4 Introduction<br />

4/5 <strong>Engineering</strong> st<strong>and</strong>ard software<br />

4/8 <strong>Engineering</strong> H systems<br />

4/8 Version cross checker<br />

4/9 Import/export assistant<br />

4/10 <strong>Engineering</strong> Process Safety<br />

4/10 Introduction<br />

4/11 <strong>Engineering</strong> F/FH systems<br />

4/12 SIMATIC safety matrix<br />

4/14 SIMATIC Route Control<br />

4/14 SIMATIC Route Control<br />

<strong>Engineering</strong><br />

4/15 ES software SIMATIC PDM<br />

4/15 Introduction<br />

4/17 SIMATIC PDM package for PCS 7<br />

4/18 SIMATIC PDM st<strong>and</strong>-alone version<br />

4/20 Supplementary ES software<br />

4/20 Controller optimization<br />

4/20 Simulation with S7-PLCSIM<br />

<strong>Siemens</strong> ST PCS 7 · October 2004


4<br />

<strong>Engineering</strong> system<br />

Introduction<br />

■ Overview<br />

The SIMATIC PCS 7 <strong>Engineering</strong> <strong>System</strong> contains tools which<br />

are compatible with all <strong>Siemens</strong> system components <strong>and</strong> can be<br />

used for:<br />

Hardware <strong>and</strong> field devices<br />

Communication networks<br />

Continuous <strong>and</strong> sequential process operations<br />

Operation <strong>and</strong> monitoring strategies<br />

SIMATIC BATCH <strong>and</strong> SIMATIC Route Control.<br />

These combine the engineering of st<strong>and</strong>ard automation <strong>and</strong> the<br />

configuration of consistent safety functions for safe, fault-tolerant<br />

<strong>and</strong> high-availability process applications.<br />

Technologists as well as process <strong>and</strong> production engineers can<br />

plan <strong>and</strong> configure in the environment they are familiar with by<br />

utilizing the <strong>Engineering</strong> Toolset designed for technological<br />

needs <strong>and</strong> the predefined blocks <strong>and</strong> plans.<br />

4/2<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

■ Function<br />

Typical automation components such as motors, valves <strong>and</strong> PID<br />

controllers are already saved as st<strong>and</strong>ardized software objects<br />

(measuring point types) in a control engineering library <strong>and</strong><br />

need only be integrated in the process operations <strong>and</strong> graphically<br />

connected. This is easy <strong>and</strong> quick to accomplish even by<br />

technologists without any programming experience. When image<br />

objects are connected, the associated OS variables are<br />

saved (together with the associated blocks where applicable) in<br />

the block list.<br />

The uniform data base for the engineering systems ensures that<br />

data which has been entered once is available system-wide.<br />

All project modifications associated with the automation systems,<br />

the operator systems <strong>and</strong> SIMATIC BATCH can be compiled<br />

<strong>and</strong> loaded in one step. The engineering system automatically<br />

ensures the correct sequence. A central dialog displays<br />

<strong>and</strong> controls the operation.<br />

Short turnaround times result in short waiting times for the commissioning<br />

engineer <strong>and</strong> have a positive impact on the commissioning<br />

costs. Changes to the configuration can be loaded online<br />

into the system components.<br />

The engineering system supports the implementation of large<br />

projects <strong>and</strong> the related processing of bulk data by providing<br />

appropriate functions such as:<br />

Plant hierarchy (plant view)<br />

Project library for measuring point types as well as the import<br />

<strong>and</strong> export of measuring points (process object view)<br />

Multi-project engineering<br />

Branch & merge<br />

Extended rename<br />

Version cross-checker<br />

Import/export assistant<br />

SFC type


■ Overview<br />

The central engineering system of the SIMATIC PCS 7 process<br />

control system is based on the same hardware as the OS single<br />

station of the operator system. This is characterized by powerful<br />

PC technology that can be used together with the Windows 2000<br />

operating system in the office as well as industrial environments<br />

<strong>and</strong> provides an optimum basis for engineering. For more userfriendliness,<br />

the operating range can be extended by connecting<br />

up as many as 4 process monitors through a special<br />

Multi-VGA graphics card.<br />

ES/OS single station<br />

The ES/OS single station is available as the st<strong>and</strong>ard item of<br />

hardware for engineering stations. It is based on the SIMATIC<br />

Rack PC IL 40 S for installation in 19&#147; rack systems. Two<br />

versions are available <strong>and</strong> differ in the way they communicate<br />

with the plant bus:<br />

PCS 7 ES/OS IL 40 S V2 BCE<br />

Communication through Basic Communication Ethernet<br />

(BCE) for max. 8 stations<br />

PCS 7 ES/OS IL 40 S V2 IE<br />

Communication through CP 1613<br />

A FastEthernet RJ45 port is already on board <strong>and</strong> can be used<br />

for connecting to an OS LAN (terminal bus).<br />

The ES/OS single station is delivered complete with the Windows<br />

2000 Professional MUI <strong>and</strong> a mouse. The keyboard <strong>and</strong> monitor<br />

have to be ordered separately.<br />

Options/expansions<br />

A Multi-VGA card can be added to the engineering system. It enables<br />

the connection of 2 or 4 monitors per operator terminal.<br />

■ Technical specifications<br />

Detailed technical data for single stations are provided in table<br />

form in the chapter "ES/OS/BATCH/IT basic devices".<br />

<strong>Engineering</strong> system<br />

B) Subject to export regulations: AL: N, ECCN: EAR99H<br />

D) Subject to export regulations: AL: N, ECCN: 5D992B1<br />

Monitors, refer to chapter "ES/OS/BATCH/IT basic devices“<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

ES hardware<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

Basic hardware for ES/OS Single Station, SIMATIC PC in rack<br />

of 19“ design, Pentium 4 with 2.8 GHz <strong>and</strong> more, 1 Gbyte<br />

RAM (2 x 512 Mbyte), sound, EIDE-RAID 1 with 2 hard disks of<br />

120 Gbyte, graphics controller on board with Dynamic Video<br />

Memory, DVD±RW IDE, optical mouse,<br />

FastEthernet RJ45 on board for connection to OS-LAN,<br />

without monitor, keyboard <strong>and</strong> printer,<br />

Windows 2000 Professional MUI (German, English, French,<br />

Italian, Spanish);<br />

SIMATIC PCS 7 preinstalled <strong>and</strong> on restore DVD<br />

PCS 7 ES/OS IL 40 S V2 BCE<br />

Connection to system bus<br />

through Basic Communication<br />

Ethernet (BCE) with FastEthernet<br />

RJ45 network card (PCI card)<br />

6ES7 650-0GC06-0YX0 D)<br />

PCS 7 ES/OS IL 40 S V2 IE<br />

Connection to system bus through<br />

Industrial Ethernet with CP 1613<br />

communications processor<br />

6ES7 650-0GC16-0YX0 D)<br />

Additional <strong>and</strong> expansion components<br />

Utility software<br />

SIMATIC PC/PG Image & Partition<br />

Creator<br />

Software for creating hard disk<br />

images <strong>and</strong> for configurating hard<br />

disk partitions<br />

6ES7 648-6AA02-0YX0 B)<br />

Memory modules for exp<strong>and</strong>ing<br />

the main memory<br />

Memory expansion kit 512<br />

Mbyte (Dual Channel) for<br />

SIMATIC Rack PC IL 40 S V2<br />

(2 x 256 Mbyte DDR SDRAM)<br />

Memory expansion kit 1 Gbyte<br />

(Dual Channel) for SIMATIC<br />

Rack PC IL 40 S V2 (2 x<br />

512 Mbyte DDR SDRAM)<br />

Memory expansion kit 2 Gbyte<br />

(Dual Channel) for SIMATIC<br />

Rack PC IL 40 S V2 (2 x 1 Gbyte<br />

DDR SDRAM)<br />

6ES7 648-2AD30-0FB0 B)<br />

6ES7 648-2AD40-0FB0 B)<br />

6ES7 648-2AD50-0FB0 B)<br />

TK 200 keyboard (PS/2 connection)<br />

German key assignment 6GF6 710-1AA<br />

International key assignment<br />

SIMATIC PC keyboard (USB<br />

connection)<br />

6GF6 710-1BA<br />

International key assignment 6ES7 648-0CB00-0YA0<br />

Multi-VGA Graphics Card<br />

"2 Screens“<br />

for operating 2 process monitors<br />

on 1 station<br />

Type of delivery:<br />

Dual graphics card, driver CD,<br />

manual, 1 dual DVI cable for<br />

2 digital outputs, 2 adapters for<br />

VGA outputs<br />

6ES7 652-0XX03-1XE0 B)<br />

Multi-VGA Graphics Card<br />

"4 Screens“<br />

for operating 4 process monitors<br />

on 1 station<br />

Type of delivery:<br />

Quad graphics card, driver CD,<br />

manual, 2 dual DVI cables for<br />

4 digital outputs, 4 adapters for<br />

VGA outputs<br />

6ES7 652-0XX03-1XE1 B)<br />

4/3<br />

4


4<br />

<strong>Engineering</strong> system<br />

ES software<br />

Introduction<br />

■ Overview<br />

■ Integration<br />

The functionality of the engineering system is largely covered by The ES software can be run on the ES hardware offered in this<br />

the st<strong>and</strong>ard engineering software. The following software op- catalog <strong>and</strong> has been tested with it. <strong>Siemens</strong> guarantees the<br />

tions are offered in addition for special functions:<br />

compatibility of hardware <strong>and</strong> software for system configurations<br />

for engineering systems with st<strong>and</strong>ard engineering software based on components in this catalog.<br />

SIMATIC PCS 7 V6.0 up to Service Pack 2 (already integrated<br />

in ServicePack 3 <strong>and</strong> higher): PCS 7 Option Package (S7-<br />

400H <strong>System</strong>s) for the engineering of automation systems with<br />

H architecture (H/F/FH systems)<br />

Version cross checker<br />

Import/export assistant<br />

Should you use basic hardware other than that offered in this catalog,<br />

please note the minimum requirements quoted in the chapter<br />

"ES/OS/BATCH/IT basic devices".<br />

If you configure your own SIMATIC PCS 7 engineering system<br />

using other/own hardware components, you carry full responsibility<br />

<strong>and</strong> will not receive any free support in the event of com-<br />

<strong>Engineering</strong> Process Safety for engineering of fail-safe syspatibility problems.<br />

tems, incl. SIMATIC Safety Matrix engineering tool<br />

Despite comprehensive tests it cannot be ruled out that the func-<br />

SIMATIC Route Control engineering<br />

tion of a SIMATIC PCS 7 system may be disturbed or impaired<br />

SIMATIC PDM Process Device Manager<br />

PCS 7 PID-Tuner for controller optimization<br />

S7-PLCSIM for the functional testing of CFC/SFC programs<br />

by additional non-system software, i.e. software not explicitly released<br />

for SIMATIC PCS 7.<br />

Therefore, the use of non-system software in the SIMATIC PCS 7<br />

environment is your responsibility. You have no claims for free<br />

support in the event of compatibility problems.<br />

4/4<br />

<strong>Siemens</strong> ST PCS 7 · October 2004


■ Overview<br />

The st<strong>and</strong>ard engineering software provides the basic functionality<br />

for configuration of SIMATIC PCS 7 system components<br />

(automation systems, process I/Os, operator systems <strong>and</strong> SI-<br />

MATIC BATCH).<br />

It is available in packages of various size to match the number<br />

of configurable process objects (250, 2,000, 3,000, 5,000 or unlimited/8,500<br />

POs). The number of configurable process objects<br />

can be subsequently increased at any time by means of engineering<br />

PowerPacks.<br />

The engineering software is available in various versions to suit<br />

different requirements:<br />

only for automation systems (AS)<br />

only for operator systems (OS)<br />

for automation systems <strong>and</strong> operator systems (AS/OS)<br />

The engineering software for automation systems <strong>and</strong> operator<br />

systems is available in each case with a 10-day restricted licence<br />

as an economical solution for short-term projects.<br />

■ Function<br />

Hardware configuration in the SIMATIC manager with HW Config<br />

Essential tools of the st<strong>and</strong>ard engineering software <strong>and</strong> their<br />

functions:<br />

SIMATIC Manager<br />

The SIMATIC Manager is the integration platform for the engineering<br />

tools <strong>and</strong> configuration interface for all engineering<br />

tasks of the SIMATIC PCS 7 process control system. All aspects<br />

of the SIMATIC PCS 7 project are managed, archived <strong>and</strong> documented<br />

here. The SIMATIC Manager provides tools for configuring<br />

the automation systems, the I/Os <strong>and</strong> the communication<br />

networks, <strong>and</strong> allows selection of the required hardware from an<br />

electronic catalog.<br />

The various tasks for creating a plant project are supported by<br />

three different views within SIMATIC Manager:<br />

The component view for the configuration of hardware, such<br />

as automation systems, bus components or process I/Os<br />

The plant view for hierarchical structuring of the plant<br />

The process object view as the central development environment<br />

for all aspects of measuring points/process objects<br />

Plant view (plant hierarchy)<br />

The plant view is used to structure <strong>and</strong> display a project in accordance<br />

with technological aspects. A technologically oriented<br />

project structure enables the technologist to find his bearings<br />

quickly. The OS areas <strong>and</strong> the image hierarchy can also be derived<br />

from this type of hierarchy <strong>and</strong> it also forms the basis for<br />

the plant-oriented identification of process objects.<br />

<strong>Engineering</strong> system<br />

ES software<br />

<strong>Engineering</strong> st<strong>and</strong>ard software<br />

Plant unit overviews, in which all operable <strong>and</strong> observable CFC<br />

blocks are positioned <strong>and</strong> connected, can be generated automatically.<br />

Process object view<br />

The process object view of the SIMATIC Manager permits a universal<br />

view of the measuring point. It shows the technological hierarchy<br />

of the plant (presented in tree form) in combination with<br />

a tabular view of all aspects of the measuring point/process object<br />

(general data, parameters, signals, messages, image objects<br />

<strong>and</strong> measured value archives).<br />

All objects in the marked branch of the hierarchy are displayed<br />

in the table so that they can be directly processed with userfriendly<br />

edit, filter, replace, import <strong>and</strong> export functions.<br />

Examples of editable OS st<strong>and</strong>ard displays (faceplates) from the PCS 7<br />

Library<br />

Libraries containing process control applications<br />

Preconfigured <strong>and</strong> tested blocks, faceplates <strong>and</strong> symbols are<br />

organized in libraries <strong>and</strong> form the basic elements for the<br />

graphic configuration of automation solutions. The use of these<br />

library elements plays a major role in minimizing the engineering<br />

input <strong>and</strong> project costs.<br />

The comprehensive range of blocks includes simple logic <strong>and</strong><br />

driver blocks, technological blocks with integral alarming <strong>and</strong><br />

HMI features such as PID controllers, motors or valves, <strong>and</strong> also<br />

blocks for the integration of PROFIBUS field devices according<br />

to PROFIBUS PA Profile 3.0 (incl. st<strong>and</strong>ardized evaluation of the<br />

process value status).<br />

Documentation on the libraries for process control applications<br />

can be found on the SIMATIC PCS 7 Documentation CD (see<br />

Documentation).<br />

Multi-project engineering<br />

Multi-project engineering permits division of a large complex<br />

project into several subprojects in accordance with technological<br />

criteria in order to allow several teams to work on the project<br />

in parallel. To achieve this, a host "Multi-project" is defined in the<br />

SIMATIC Manager. Individual (sub)projects can be inserted into<br />

or removed from a multi-project at any time. Similarly, projects<br />

can be merged or divided (Branch & Merge).<br />

The (sub)projects belonging to a multi-project are all saved on a<br />

central server <strong>and</strong> can be sent to a local engineering station for<br />

editing. The engineering performance is then not affected by<br />

network access.<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

4/5<br />

4


4<br />

<strong>Engineering</strong> system<br />

ES software<br />

<strong>Engineering</strong> st<strong>and</strong>ard software<br />

Branch & Merge<br />

Branch & Merge capability is provided in conjunction with multiproject<br />

engineering <strong>and</strong> supports the effective dividing <strong>and</strong><br />

merging of projects. Charts or plant units can be copied into another<br />

project <strong>and</strong> edited there.<br />

Charts with the same name in the master project are overwritten<br />

during Branch & Merge. Interconnections which are not specific<br />

to a project, typically for interlocking, become text interconnections<br />

when branched. When merging, these text interconnections<br />

– including those entered by the user – can be closed by<br />

pressing a key.<br />

Sequential function chart<br />

Sequential function chart (SFC)<br />

SFC is used for the graphical configuration of sequence control<br />

systems for non-continuous production operations. Each SFC<br />

plan contains inputs <strong>and</strong> outputs for the control function <strong>and</strong> for<br />

status data. SFCs can be directly positioned in a CFC <strong>and</strong> interconnected.<br />

The required CFC block connections are selected<br />

by simple operations <strong>and</strong> connected to the steps or transitions<br />

of the step chains.<br />

An ISA S88-conform status manager enables the configuration<br />

of up to 8 separate sequence chains for special treatments<br />

within a single SFC, e.g. for states such as HOLDING or<br />

ABORTING, for SAFE STATE or for different operating modes.<br />

SFC configuration is supported by user-friendly editing functions<br />

<strong>and</strong> powerful test <strong>and</strong> IBS functions.<br />

4/6<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

Continuous function chart<br />

Continuous function chart (CFC)<br />

CFC is the tool for graphical configuration of continuous automation<br />

functions. Preengineered function blocks can be positioned,<br />

configured <strong>and</strong> interconnected within CFCs using powerful autorouting<br />

<strong>and</strong> the integral configuration of HMI messages. When<br />

creating a new CFC, a new runtime group with the same name<br />

as the chart is created. All the blocks that are subsequently entered<br />

in the chart are automatically added to this runtime group.<br />

The order of the run sequence can be optimized during compilation.<br />

An algorithm first determines the optimal order of the<br />

blocks <strong>and</strong> then the order of the run-time groups.<br />

SFC type<br />

An SFC type can be placed, parameterized <strong>and</strong> interconnected<br />

as an instance in a CFC just like a normal function block. It can<br />

therefore be reused, <strong>and</strong> a change to the master causes all instances<br />

to be automatically updated accordingly.<br />

Automatic interconnection of blocks<br />

The function "Generate module driver" can be used to automatically<br />

generate <strong>and</strong> place diagnostics blocks for the I/O components<br />

of the S7-400 automation system, the ET 200M, ET 200iS<br />

<strong>and</strong> ET 200S distributed I/O systems, <strong>and</strong> for PROFIBUS field<br />

devices according to the PROFIBUS PA Profile 3.0 <strong>and</strong> field devices<br />

with HART communication. The blocks are interconnected<br />

by a wizard on the basis of the symbolic addresses.<br />

Graphics designer <strong>and</strong> faceplate designer<br />

The project data for the engineering of the operator systems are<br />

organized using SIMATIC Manager. All the data relevant to operation<br />

<strong>and</strong> monitoring of a control element, such as messages<br />

<strong>and</strong> HMI variables, are generated automatically during definition<br />

of the automation function. A powerful graphics designer is<br />

available for the generation of process displays.<br />

Customer-specific faceplates can be created in addition to the<br />

st<strong>and</strong>ard faceplates for operation <strong>and</strong> monitoring of control elements<br />

or parts of the plant. With the faceplate designer it is easy<br />

<strong>and</strong> quick to generate such customer-specific faceplates.<br />

DOCPRO<br />

DOCPRO generates plant documentation for SIMATIC PCS 7<br />

projects in accordance with defined st<strong>and</strong>ards, as well as a circuit<br />

manual in which special requirements can be entered.


■ Selection <strong>and</strong> Ordering Data<br />

PCS 7 <strong>Engineering</strong> Software<br />

Single license<br />

trilingual (German, English,<br />

French)<br />

Electronic documentation on<br />

PCS 7 Toolset CDs <strong>and</strong> PCS 7<br />

Documentation CD<br />

Type of delivery:<br />

Certificate of license, authorization<br />

diskette, PCS 7 Toolset CDs<br />

<strong>and</strong> additional CDs with Service<br />

Pack 3 for Microsoft Windows<br />

2000 (in 5 languages), Microsoft<br />

Internet Explorer, Microsoft SQL<br />

Server 2000 <strong>and</strong> PC Anywhere<br />

Order No.<br />

AS, for 250 POs (process objects)<br />

6ES7 658-1AA06-0YA0 D)<br />

AS, for 2,000 POs 6ES7 658-1AB06-0YA0 D)<br />

AS, for 3,000 POs 6ES7 658-1AC06-0YA0 D)<br />

AS, for 5,000 POs 6ES7 658-1AD06-0YA0 D)<br />

AS, POs unlimited 6ES7 658-1AE06-0YA0 D)<br />

AS, POs unlimited, 10 days 6ES7 658-1AE06-3YA0 D)<br />

OS, for 250 POs/RC 8K 6ES7 658-2DA06-0YA0 D)<br />

OS, for 2,000 POs/RC 64K 6ES7 658-2DB06-0YA0 D)<br />

OS, for 3,000 POs/RC 100K 6ES7 658-2DC06-0YA0 D)<br />

OS, for 5,000 POs/RC 150K 6ES7 658-2DD06-0YA0 D)<br />

OS, for 8,500 POs/RC 256K 6ES7 658-2DE06-0YA0 D)<br />

OS, for 8,500 POs/RC 256K,<br />

10 days<br />

6ES7 658-2DE06-3YA0 D)<br />

AS/OS, for 250 POs/RC 8K 6ES7 658-5AA06-0YA0 D)<br />

AS/OS, for 2,000 POs/RC 64K 6ES7 658-5AB06-0YA0 D)<br />

AS/OS, for 3,000 POs/RC 100K 6ES7 658-5AC06-0YA0 D)<br />

AS/OS, for 5,000 POs/RC 150K 6ES7 658-5AD06-0YA0 D)<br />

AS/OS, POs unlimited/RC 256K<br />

PCS 7 <strong>Engineering</strong><br />

PowerPack AS<br />

for extending the <strong>Engineering</strong><br />

Software for AS<br />

Type of delivery:<br />

Certificate of license <strong>and</strong> authorization<br />

diskette<br />

6ES7 658-5AE06-0YA0 D)<br />

from 250 POs to 2,000 POs 6ES7 658-1AB06-0YD0<br />

from 2,000 POs to 3,000 POs 6ES7 658-1AC06-0YD0<br />

from 3,000 POs to 5,000 POs 6ES7 658-1AD06-0YD0<br />

from 5,000 POs to POs unlimited<br />

PCS 7 <strong>Engineering</strong><br />

PowerPack OS<br />

for extending the <strong>Engineering</strong><br />

Software for OS<br />

Type of delivery:<br />

Certificate of license <strong>and</strong> authorization<br />

diskette<br />

6ES7 658-1AE06-0YD0<br />

from 250 POs/RC 8K to<br />

2,000 POs/RC 64K<br />

6ES7 658-2DB06-0YD0<br />

from 2,000 POs/RC 64K to<br />

3,000 POs/RC 100K<br />

6ES7 658-2DC06-0YD0<br />

from 3,000 POs/RC 100K to<br />

5,000 POs/RC 150K<br />

6ES7 658-2DD06-0YD0<br />

from 5,000 POs/RC 150K to<br />

8,500 POs/RC 256K<br />

6ES7 658-2DE06-0YD0<br />

<strong>Engineering</strong> system<br />

ES software<br />

<strong>Engineering</strong> st<strong>and</strong>ard software<br />

■ Selection <strong>and</strong> Ordering Data<br />

PCS 7 <strong>Engineering</strong> PowerPack<br />

AS/OS<br />

for extending the <strong>Engineering</strong><br />

Software for AS/OS<br />

Type of delivery:<br />

Certificate of license <strong>and</strong> authorization<br />

diskette<br />

Order No.<br />

from 250 POs/RC 8K to<br />

2,000 POs/RC 64K<br />

6ES7 658-5AB06-0YD0<br />

from 2,000 POs/RC 64K to<br />

3,000 POs/RC 100K<br />

6ES7 658-5AC06-0YD0<br />

from 3,000 POs/RC 100K to<br />

5,000 POs/RC 150K<br />

6ES7 658-5AD06-0YD0<br />

from 5,000 POs/RC 150K to<br />

POs unlimited/RC 256K<br />

<strong>Engineering</strong> Software Upgrade<br />

from V5.x to V6.0<br />

Electronic documentation on<br />

PCS 7 Toolset CDs <strong>and</strong> PCS 7<br />

Documentation CD<br />

Type of delivery:<br />

Certificate of license, authorization<br />

diskette, PCS 7 Toolset CDs<br />

<strong>and</strong> additional CDs with Service<br />

Pack 3 for Microsoft Windows<br />

2000 (in 5 languages), Microsoft<br />

Internet Explorer, Microsoft SQL<br />

Server 2000 <strong>and</strong> PC Anywhere<br />

Can be exp<strong>and</strong>ed with PCS 7<br />

<strong>Engineering</strong> Power Packs<br />

Upgrade PCS 7 Starter Package<br />

6ES7 658-5AE06-0YD0<br />

AS/OS upgrade, for<br />

250 POs/RC 8K<br />

ES Software <strong>Engineering</strong> upgrade<br />

6ES7 658-5AA06-0YE0 D)<br />

AS upgrade for 3,000 POs 6ES7 658-1AC06-0YE0 D)<br />

AS upgrade for POs unlimited<br />

OS Software <strong>Engineering</strong><br />

upgrade<br />

6ES7 658-1AE06-0YE0 D)<br />

OS upgrade for<br />

2,000 POs/RC 64K<br />

6ES7 658-2DB06-0YE0 D)<br />

OS upgrade for<br />

5,000 POs/RC 150K<br />

6ES7 658-2DD06-0YE0 D)<br />

D) Subject to export regulations: AL: N, ECCN: 5D992B1<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

4/7<br />

4


4<br />

<strong>Engineering</strong> system<br />

ES software<br />

<strong>Engineering</strong> H systems<br />

■ Overview<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

In the case of engineering systems with st<strong>and</strong>ard engineering S7-400H V5.2 Option Package 6ES7 833-2AC01-0YB0<br />

software SIMATIC PCS 7 V6.0 up to Service Pack 2 you must in- For STEP 7 <strong>and</strong> SIMATIC PCS 7<br />

stall the S7-400H option package in order to be able to configure<br />

automation systems with H architecture (H/F/FH systems). With<br />

Service Pack 3 <strong>and</strong> higher, the functionality of the S7-400H op-<br />

Note: Only for engineering systems<br />

with st<strong>and</strong>ard engineering<br />

software SIMATIC PCS 7 V6.0 up<br />

tion package is already integrated in the st<strong>and</strong>ard engineering to Service Pack 2<br />

software.<br />

Type of delivery:<br />

The F-Tool engineering tool (S7 F <strong>System</strong>s) is required in addition<br />

for F/FH systems.<br />

Certificate of license <strong>and</strong> authorization<br />

diskette<br />

Version Cross Checker<br />

■ Overview<br />

The version cross-checker tool determines the differences between<br />

various versions of a project by:<br />

Comparison of CFCs/SFCs, block types, signals <strong>and</strong> sequences<br />

in order to determine what is new, what has been deleted,<br />

<strong>and</strong> what has been changed<br />

Graphic display of comparison results in a combination of tree<br />

<strong>and</strong> tabular format<br />

Color-coded identification of objects <strong>and</strong> attribute values<br />

4/8<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

PCS 7 Version Cross Checker 6ES7 658-1CX06-2YA0<br />

V6.0<br />

Single license<br />

trilingual (German, English,<br />

French)<br />

Software on PCS 7 Toolset CDs,<br />

electronic documentation as<br />

online help integrated in the software<br />

Type of delivery:<br />

Certificate of license <strong>and</strong> authorization<br />

diskette


■ Overview<br />

The import/export assistant is a large plant engineering tool for<br />

replicating common configuration elements, e.g. based on st<strong>and</strong>ardized<br />

types of control element. It can significantly shorten the<br />

time required for configuration by allowing users to import plant<br />

data which have already been configured (such as control element<br />

lists or charts from the CAD/CAE world) directly into the engineering<br />

system <strong>and</strong> automatically generating the corresponding<br />

user program. Existing PCS 7 projects can be both exported<br />

<strong>and</strong> reimported.<br />

<strong>Engineering</strong> system<br />

ES software<br />

Import/export assistant<br />

■ Benefits<br />

The import/export wizard offers the following benefits:<br />

Importing of pre-existing plant layout data, such as control element<br />

lists from the higher-level CAD/CAE world<br />

- No multiple inputs, minimized configuration errors<br />

- Simple h<strong>and</strong>ling, easy-to-use graphic environment<br />

Automatic generation of control elements based on the imported<br />

control element lists <strong>and</strong> typicals<br />

- Generation of technological hierarchy<br />

- Charts of the individual control elements<br />

- Drastic reduction of time, <strong>and</strong> avoidance of errors through<br />

automatic/reproducible generation<br />

Automatic derivation of the OS display hierarchy, automatic interconnecting<br />

of blocks <strong>and</strong> placing in displays<br />

- Considerable reduction of time <strong>and</strong> costs<br />

Commissioning the individual control elements with the userfriendly<br />

CFC <strong>and</strong> SFC graphic tools<br />

Exporting of parameters optimized during commissioning<br />

back to the CAD/CAE world<br />

- Consistent data in the higher-level planning tools<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

PCS 7 Import/Export Assistant 6ES7 658-1DX06-2YB0<br />

V6.0<br />

Single license<br />

trilingual (German, English,<br />

French)<br />

Software on PCS 7 Toolset CDs,<br />

electronic documentation on<br />

PCS 7 Documentation CD<br />

Type of delivery: Certificate of<br />

Efficient bulk engineering using the import/export assistant license <strong>and</strong> authorization diskette<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

4/9<br />

4


4<br />

<strong>Engineering</strong> system<br />

<strong>Engineering</strong> Process Safety<br />

Introduction<br />

■ Overview<br />

Today’s process industry is often characterized by complex<br />

technological sequences with high safety dem<strong>and</strong>s, in which<br />

any failures <strong>and</strong> errors in process automation could have fatal<br />

consequences for man, machine, plants or the environment.<br />

This is where Process Safety comes into its own. The implemented<br />

safety engineering must reliably detect both errors in the<br />

process <strong>and</strong> internal errors, <strong>and</strong> automatically place the<br />

plant/application in a safe state in the event of a fault.<br />

With SIMATIC Safety Integrated, SIMATIC PCS 7 combines st<strong>and</strong>ard<br />

automation <strong>and</strong> safety engineering in an innovative overall<br />

system, which offers consistent safety engineering for reliable,<br />

failsafe, high-availability applications in the process industry:<br />

AS 414F/FH <strong>and</strong> AS 417F/FH automation systems<br />

PROFIBUS communication with PROFIsafe profile<br />

Distributed I/Os ET 200M <strong>and</strong> ET 200S with special failsafe<br />

modules<br />

Convenient process visualization, incl. safety-oriented fault indications<br />

over the operator system<br />

<strong>Engineering</strong> system with software package S7 F <strong>System</strong>s,<br />

CFC <strong>and</strong> SIMATIC Safety Matrix<br />

4/10<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

The SIMATIC PCS 7 engineering system offers you a consistent<br />

engineering tool for st<strong>and</strong>ard <strong>and</strong> safety applications. Continuous<br />

Function Chart (CFC) <strong>and</strong> S7 F <strong>System</strong>s allows the simple,<br />

efficient <strong>and</strong> cost-effective configuration of safety functions for<br />

failsafe I/Os modules <strong>and</strong> AS 414F/FH <strong>and</strong> AS 417F/FH. The<br />

SIMATIC Safety Matrix offers even more advantages. The convenient<br />

configuration tool automatically creates complex failsafe<br />

programs on the basis of a cause & effect matrix, with which it is<br />

possible to assign exactly defined reactions (effect) to events<br />

ocurring in the course of a process (cause).


■ Overview<br />

The S7 F <strong>System</strong>s <strong>Engineering</strong> Tool, which is integrated in the<br />

SIMATIC Manager, can be used to configure an F system (F/FH).<br />

This tool enables<br />

parameterization of the CPU <strong>and</strong> F signal modules <strong>and</strong><br />

generation of failsafe applications in the CFC.<br />

Predefined, TÜV-approved blocks are available for this purpose.<br />

The failsafe blocks relieve the user of having to perform the diverse<br />

programming tasks for the detection of errors <strong>and</strong> reaction<br />

to errors.<br />

The application program may contain failsafe (F) <strong>and</strong> non-failsafe<br />

st<strong>and</strong>ard programs (S), where strict separation of F <strong>and</strong> S<br />

program components together with data exchange by means of<br />

special conversion blocks prevent conflicts.<br />

S7 F <strong>System</strong>s supports the acceptance testing <strong>and</strong> comparison<br />

of F programs using a checksum that enables every minor<br />

change to be detected. This checksum is recorded during the<br />

TÜV acceptance test. A password prevents access to non-authorized<br />

persons.<br />

<strong>Engineering</strong> system<br />

<strong>Engineering</strong> Process Safety<br />

<strong>Engineering</strong> F/FH systems<br />

An S7 F Configuration Pack is required for the engineering when<br />

using the failsafe I/Os SM 326F/336F (AI, DI, DO) as st<strong>and</strong>ard<br />

I/Os (without F functionality). This is a component of the F programming<br />

tool S7 F <strong>System</strong>s V5.2 <strong>and</strong> can also be downloaded<br />

from the Internet (as part of product support provided by <strong>Automation</strong><br />

<strong>and</strong> <strong>Drives</strong> Service & Support: S7 F Configuration Pack<br />

V5.3).<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

S7 F <strong>System</strong>s V5.2<br />

6ES7 833-1CC00-0YX0<br />

F program software <strong>and</strong> function<br />

block library, single license<br />

Bilingual (German, English)<br />

Type of delivery:<br />

Certificate of license <strong>and</strong> authorization<br />

diskette;software <strong>and</strong> electronic<br />

documentation on CD<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

4/11<br />

4


4<br />

<strong>Engineering</strong> system<br />

<strong>Engineering</strong> Process Safety<br />

SIMATIC safety matrix<br />

■ Overview<br />

■ Design<br />

With the Safety Matrix, we offer an innovative configuration tool In the context of SIMATIC PCS 7, the following individual prod-<br />

for processes that require safety reactions to defined states. The ucts are available for the SIMATIC Safety Matrix:<br />

Safety Matrix is based on the proven principle of a cause & effect<br />

matrix with which it is possible to assign exactly defined reactions<br />

(effect) to events ocurring in the course of a process<br />

(cause). This is an integral part of the risk analysis of a plant. The<br />

specification of the safety program also corresponds to the input<br />

parameters for the safety matrix. Using these parameters, the<br />

Safety Matrix automatically generates failsafe CFC programs for<br />

SIMATIC PCS 7.<br />

Compared to conventional programming, safety logic can thus<br />

be configured significantly faster <strong>and</strong> with considerably less<br />

cost/input. Configurators do not require any special programming<br />

expertise <strong>and</strong> can concentrate fully on the safety requirements<br />

of their plants. If required, several matrices can also be interlinked.<br />

SIMATIC Safety Matrix Tool<br />

for the configuration of safety functions on the PCS 7 <strong>Engineering</strong><br />

<strong>System</strong><br />

SIMATIC Safety Matrix Editor<br />

for creating <strong>and</strong> checking the Safety Matrix logic in an external<br />

computer, independent of the engineering system; (can also<br />

be optionally used as an add-on to SIMATIC Safety Matrix<br />

Tool)<br />

SIMATIC Safety Matrix Viewer for SIMATIC PCS 7<br />

for the operation <strong>and</strong> monitoring Safety Matrix using the SI-<br />

MATIC PCS 7 operator system (for order date, please also refer<br />

to the section "OS Software" in the Chapter "Operator <strong>System</strong>")<br />

■ Benefits<br />

<strong>System</strong> requirements<br />

Hardware require- Software requirements<br />

The advantages of Safety Matrix at a glance:<br />

7 Configuration of safety functions (logic) using the proven<br />

cause & effect method – i.e. on the basis of process events<br />

<strong>and</strong> process reactions<br />

ments<br />

SIMATIC Safety Matrix SIMATIC PCS 7<br />

Tool<br />

AS 414H or<br />

AS 417H<br />

PCS 7 V6.0, SP2 or<br />

higher,<br />

S7 F <strong>System</strong>s V5.2 , HF 2<br />

or higher with S7 F-Lib<br />

7 Automatic generation of the safety-oriented SIMATIC PCS 7<br />

V1.2<br />

program<br />

SIMATIC Safety Matrix<br />

Windows 2000 Profes-<br />

7 Minimization of sources of error due to easy <strong>and</strong> clearly presented<br />

configuration<br />

Editor<br />

sional, SP2 or higher or<br />

Windows XP Professional<br />

7 Automatic creation of documentation after safety checks<br />

7 Shortened configuration times <strong>and</strong> no need for special programming<br />

skills<br />

7 Automatic generation of visualization <strong>and</strong> convenient display<br />

SIMATIC Safety Matrix SIMATIC PCS 7<br />

Viewer<br />

AS 414H or<br />

AS 417H<br />

PCS 7-OS V6.0, SP2 or<br />

higher<br />

of the Safety Matrix on the SIMATIC PCS 7 operator station The SIMATIC Safety Matrix Editor has the added benefit that the<br />

7 Automatic management of project versions of the program<br />

7 User-friendly tracking of changes<br />

Safety Matrix can also be created, processed <strong>and</strong> checked outside<br />

the SIMATIC PCS 7 engineering system. The SIMATIC<br />

Safety Matrix Editor can be used on any computer with Windows<br />

7 Easy modification of safety functions <strong>and</strong> simple adaptation of 2000 Professional, SP2 or higher or Windows XP Professional.<br />

the specification in test mode, as well as bypass, reset <strong>and</strong> However, generating the failsafe CFC program <strong>and</strong> compiling<br />

override functions.<br />

<strong>and</strong> loading it into the automation system is only possible using<br />

the SIMATIC engineering system with SIMATIC Safety Matrix<br />

Tool.<br />

4/12<br />

<strong>Siemens</strong> ST PCS 7 · October 2004


■ Function<br />

Safety Matrix: "Intersections" define the linking of "cause" <strong>and</strong> "effect"<br />

Configuration of analog or digital "causes" <strong>and</strong> digital "effects"<br />

The matrix table is similar to a conventional spreadsheet. In the<br />

horizontal lines, the user first enters possible process events (inputs)<br />

<strong>and</strong> configures the type <strong>and</strong> number of inputs, possible<br />

delays, interlockings <strong>and</strong> logical operations. The user also defines<br />

here if <strong>and</strong> which faults can be tolerated. After configuring<br />

the causes, the effects, i.e. the reactions (outputs) to a specific<br />

event are entered in the vertical columns. The interlinking of<br />

causes <strong>and</strong> effects is then implemented by simply clicking the<br />

cell at the intersection of row <strong>and</strong> column. This opens a window<br />

in which the user can select the type of link.<br />

<strong>Engineering</strong> system<br />

<strong>Engineering</strong> Process Safety<br />

C) Subject to export regulations: AL: N, ECCN: EAR99S<br />

SIMATIC safety matrix<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

SIMATIC Safety Matrix Tool<br />

Creation, configuration, compilation,<br />

loading <strong>and</strong> online monitoring<br />

of the Safety Matrix in a<br />

SIMATIC PCS 7 environment<br />

Bilingual (German, English)<br />

single license for 1 installation,<br />

type of delivery: Certificate of<br />

license <strong>and</strong> authorization diskette<br />

for Safety Matrix Tool <strong>and</strong> Safety<br />

Matrix Viewer; software <strong>and</strong> electronic<br />

documentation on CD<br />

6ES7 833-1SM00-0YA5 C)<br />

SIMATIC Safety Matrix Editor<br />

Creation <strong>and</strong> checking of the<br />

Safety Matrix logic on an external<br />

computer without a SIMATIC<br />

PCS 7/ STEP 7 environment<br />

Bilingual (German, English)<br />

single license for 1 installation,<br />

type of delivery: Certificate of<br />

license <strong>and</strong> authorization diskette;<br />

software <strong>and</strong> electronic<br />

documentation on CD<br />

6ES7 833-1SM40-0YA5 C)<br />

SIMATIC Safety Matrix Viewer<br />

for SIMATIC PCS 7<br />

Operation <strong>and</strong> monitoring of the<br />

Safety Matrix in a SIMATIC PCS 7<br />

environment with several operator<br />

control levels<br />

Bilingual (German, English)<br />

single license for 1 installation,<br />

type of delivery: Certificate of<br />

license <strong>and</strong> authorization diskette;<br />

software <strong>and</strong> electronic<br />

documentation on CD<br />

6ES7 833-1SM60-0YA5 C)<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

4/13<br />

4


4<br />

<strong>Engineering</strong> system<br />

SIMATIC Route Control<br />

SIMATIC Route Control <strong>Engineering</strong><br />

■ Overview<br />

Route Control <strong>Engineering</strong> Tool<br />

Once the RC-relevant basic data of a PCS 7 project have been<br />

adopted in a Route Control project, the next step is to configure<br />

the RC-specific objects with the Route Control <strong>Engineering</strong> Tool:<br />

Partial Routes:<br />

Dividing the transport routes into partial routes helps to increase<br />

flexibility <strong>and</strong> to minimize the amount of configuration<br />

work through grouping. Relevant partial route parameters: "bidirectional"<br />

<strong>and</strong> "priority" (when searching for a route, the lowest<br />

total of partial route priorities is decisive for the overall<br />

route)<br />

Locations:<br />

The beginning <strong>and</strong> end of each partial route - <strong>and</strong> hence the<br />

source <strong>and</strong> destination of a material transport - are marked by<br />

locations. The locations are also parameters for requesting a<br />

material transport (source, destination, intermediate locations/via).<br />

Interconnections:<br />

The RC elements are incorporated in a partial route <strong>and</strong> thus<br />

"interconnected" with it. As a result, the RC elements acquire<br />

additional properties depending on their type (e.g. "close<br />

valve" in base position). These properties can be edited in<br />

configuration windows.<br />

The configuration of Route Control builds on the basic configuration<br />

of the SIMATIC PCS 7 process control system using<br />

blocks from the PCS 7 St<strong>and</strong>ard Library. Technological elements<br />

of relevance for Route Control (RC elements) are adapted in the<br />

CFC Editor using uniform interface blocks from the Route Control<br />

Library. This means that existing plants are also easy to upgrade<br />

with SIMATIC Route Control.<br />

Detailed information, see the chapter "SIMATIC Route Control".<br />

Function Catalogs:<br />

The partial routes can be assigned to certain function catalogs,<br />

e.g. "Cleaning" or "Product Transport", according to technological<br />

<strong>and</strong> product-specific aspects. When searching for<br />

routes, function catalogs allow you to limit the results to the<br />

type of material transport.<br />

Function Steps/Sequence Functions<br />

Each function catalog includes as many as 32 configurable<br />

■ Function<br />

The SIMATIC Route Control <strong>Engineering</strong> program package with<br />

the following configuration components is available in addition to<br />

the basic tools of the SIMATIC PCS 7 <strong>Engineering</strong> <strong>System</strong> for<br />

configuring Route Control applications:<br />

technological sequence functions, e.g. base position of the<br />

control elements, open transport valves, open source valve,<br />

switch on pump. Together with the RC elements interconnected<br />

in the partial routes, the sequence functions determine<br />

the sequence of the material transport.<br />

Special configuration functions make it easier to perform repetitive<br />

routine <strong>and</strong> extend the range of options for controlling mate-<br />

Route Control Library<br />

rial transports, e.g.:<br />

The Route Control Library contains blocks for RC configuration,<br />

blocks for creating transport routes, <strong>and</strong> interface blocks for<br />

RC elements: control (actuator) elements, sensor elements, pa-<br />

Exporting configuration data in the form of CSV files to<br />

Microsoft Excel, copying <strong>and</strong> editing the data there, <strong>and</strong> then<br />

reimporting the files into Route Control<br />

rameter (RC setpoint) elements <strong>and</strong> connection elements (material<br />

data related to a partial route). It is made available in the catalog<br />

of the CFC Editor.<br />

Controlling the joint use of partial routes by configurable function<br />

IDs<br />

Checking material compatibilities <strong>and</strong> interlocking partial<br />

Route Control Wizard<br />

routes in case of incompatible material sequences based on<br />

the material ID saved in the connection element of the partial<br />

The Route Control Wizard is the interface between the RC con- route<br />

figuration <strong>and</strong> the SIMATIC PCS 7 basic configuration. The wizard,<br />

which can be called up from the SIMATIC Manager menu,<br />

Connecting to the route block in runtime the dynamic (exter-<br />

receives the RC-specific configuration data of the SIMATIC<br />

nal) setpoint values arriving from the process (e.g. weighed<br />

PCS 7 project for importing into the Route Control <strong>Engineering</strong>.<br />

quantity)<br />

In doing so it carries out a plausibility check, defines the AS-OS ■ Selection <strong>and</strong> Ordering Data Order No.<br />

<strong>and</strong> AS-AS communication connections <strong>and</strong> configures the<br />

RC server signals.<br />

SIMATIC Route Control <strong>Engineering</strong><br />

V6.0<br />

Single license for 1 installation, trilingual<br />

(German, English, French)<br />

Software <strong>and</strong> electronic documentation<br />

on the CD SIMATIC<br />

Route Control V6.0<br />

Type of delivery:<br />

CD SIMATIC Route Control V6.0,<br />

certificate of license <strong>and</strong> authorization<br />

diskette<br />

6ES7 658-7DX06-0YA0 D)<br />

4/14<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

D) Subject to export regulations: AL: N, ECCN: 5D992B1


■ Overview<br />

Configuration options with SIMATIC PDM<br />

SIMATIC PDM (Process Device Manager) is a universal, vendorindependent<br />

tool for the configuration, parameterization, commissioning,<br />

diagnosis <strong>and</strong> servicing of intelligent field devices<br />

(sensors <strong>and</strong> actuators) <strong>and</strong> field components (remote I/Os,<br />

multiplexers, control-room devices, compact controllers), which<br />

in the following sections will be referred to simply as devices. Using<br />

one software, SIMATIC PDM enables the processing of more<br />

than 1,000 devices from <strong>Siemens</strong> <strong>and</strong> over 100 vendors worldwide<br />

on one homogeneous user interface.<br />

With respect to device integration, SIMATIC PDM is the most<br />

powerful device manager available on the world market. Devices<br />

which previously were not supported can be easily integrated<br />

in SIMATIC PDM at any time by importing their device descriptions<br />

(EDD). This provides security for your investment <strong>and</strong><br />

saves you investment costs, training expenses <strong>and</strong> consequential<br />

costs.<br />

Parameters <strong>and</strong> functions for all supported devices are displayed<br />

in a consistent <strong>and</strong> uniform fashion independent of their<br />

communications interface.<br />

■ Design<br />

<strong>Engineering</strong> system<br />

ES software SIMATIC PDM<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

Introduction<br />

Product Versions<br />

SIMATIC PDM is available in two product versions:<br />

as the SIMATIC PDM Package for SIMATIC PCS 7/S7, fully integrated<br />

in the central engineering system of SIMATIC PCS 7<br />

or in STEP 7, or<br />

as the SIMATIC PDM St<strong>and</strong>-alone, on a mobile computer (Microsoft<br />

Windows 95, 98, ME, NT, 2000 or XP Professional) on<br />

PROFIBUS or with direct connection to the device.<br />

Customer-oriented product structure<br />

SIMATIC PDM is optimally adapted to the customer’s needs <strong>and</strong><br />

structured to enable the customer to put together his very own<br />

product with the functionality actually required. Which product<br />

components he selects depends on whether SIMATIC PDM is<br />

operated in the SIMATIC PCS 7 context or in st<strong>and</strong>-alone mode.<br />

Depending on the number of devices integrated in a project<br />

or diagnosed in the lifelist, SIMATIC PDM is infinitely scalable<br />

from 4 TAGs (st<strong>and</strong>-alone version) or 128 TAGs, through<br />

128/512/1.024/2.048 TAGs, to an unlimited number of TAGs.<br />

Every device (e.g. transmitter, positioner etc.) corresponds to<br />

one TAG, <strong>and</strong> the number of TAGs within a project is monitored<br />

by SIMATIC PDM.<br />

4/15<br />

4


4<br />

<strong>Engineering</strong> system<br />

ES software SIMATIC PDM<br />

Introduction<br />

SIMATIC PDM St<strong>and</strong>-alone SIMATIC PDM Package for<br />

Communication<br />

SIMATIC PCS 7 / S7<br />

SIMATIC PDM supports several communication protocols <strong>and</strong><br />

SIMATIC PDM Basic Software incl. SIMATIC PDM Starter Package<br />

4TAGs<br />

PCS 7 incl. 128 TAGs<br />

components for communicating with devices that have the following<br />

interfaces:<br />

Option: Integration in STEP 7/<br />

PROFIBUS DP/PA interface<br />

PCS 7<br />

Option: Routing through S7-400<br />

HART interface<br />

Modbus interface<br />

Option: Communication through<br />

st<strong>and</strong>ard HART multiplexer<br />

Option: Communication through<br />

st<strong>and</strong>ard HART multiplexer<br />

Special interface from <strong>Siemens</strong><br />

TAG options:<br />

TAG options:<br />

Routing<br />

128<br />

512<br />

From the central engineering system of the SIMATIC PCS 7 pro-<br />

512<br />

1.024<br />

cess control system it is possible with SIMATIC PDM to reach ev-<br />

1.024<br />

2.048<br />

unlimited<br />

2.048<br />

unlimited<br />

ery EDD-parameterizable device in the field plant-wide through<br />

the various bus systems <strong>and</strong> remote I/Os. SIMATIC PDM can<br />

thus perform the following from a central position:<br />

read diagnosis information from the devices,<br />

■ Function<br />

modify device settings,<br />

adjust <strong>and</strong> calibrate devices,<br />

Core functions<br />

monitor process values,<br />

Adjustment <strong>and</strong> modification of device parameters<br />

create simulation values or<br />

Comparing (e.g. project <strong>and</strong> device data)<br />

reparameterize devices.<br />

Plausibility testing of data input<br />

Device identification <strong>and</strong> testing<br />

■ Integration<br />

Device status indication with operating modes, alarms <strong>and</strong><br />

states<br />

Device Integration<br />

Device identification <strong>and</strong> testing<br />

Simulation<br />

SIMATIC PDM supports all devices which are defined by means<br />

of the Electronic Device Description (EDD). Based on EN 50391<br />

<strong>and</strong> IEC 61804, EDD is the most widely used st<strong>and</strong>ardized tech-<br />

Diagnosis<br />

nology for device integration. It is also a directive of the estab-<br />

Management (e.g. networks <strong>and</strong> PCs)<br />

Commissioning functions, e.g. measuring circuit tests of device<br />

data<br />

Export/import<br />

Device replacement (lifecycle management)<br />

lished organizations for PROFIBUS (PNO: PROFIBUS-Nutzerorganisation)<br />

<strong>and</strong> HART (HCF: HART Communication Foundation).<br />

In SIMATIC PDM the devices are integrated directly by means of<br />

their EDD or the current HCF catalog. In the EDD the device is<br />

described in terms of its functions <strong>and</strong> construction using the<br />

Electronic Device Description Language (EDDL) specified by<br />

Saving of user operations (audit trail)<br />

PNO. SIMATIC PDM automatically creates its graphical user in-<br />

Graphic presentations of echo envelope curves, trend display,<br />

valve diagnosis results etc.<br />

terface with the specific device information using this description.<br />

Support of system management<br />

The current SIMATIC PDM device catalog covers more than<br />

1,000 devices from over 100 manufacturers worldwide. Further-<br />

SIMATIC PDM supports the operative system management in more, the devices of all manufacturers can be integrated at any<br />

particular through:<br />

time by simply importing their EDD into the SIMATIC PDM. It is<br />

Uniform presentation <strong>and</strong> operation of devices<br />

Indicators for preventive maintenance <strong>and</strong> servicing<br />

thus possible to keep the device range up to date at all times<br />

<strong>and</strong> to add to the number of manufacturers <strong>and</strong> devices supported<br />

by SIMATIC PDM. If you would like to use any devices<br />

Detection of changes in the project <strong>and</strong> device<br />

which cannot be found in the SIMATIC PDM device catalog, we<br />

Increasing the operational reliability<br />

will be glad to help you integrate them.<br />

Reducing the investment, operating <strong>and</strong> maintenance costs Contact addresses<br />

User interface<br />

The operator interface of SIMATIC PDM satisfies the requirements<br />

of the directives VDI/VDE GMA 2187 <strong>and</strong> IEC 65/349/CD.<br />

<strong>Siemens</strong> AG, <strong>Automation</strong> <strong>and</strong> <strong>Drives</strong>,<br />

Technical Support<br />

Europe<br />

Even complex devices with several hundred parameters can<br />

thus be represented clearly <strong>and</strong> processed quickly. Using<br />

SIMATIC PDM it is very easy to navigate in highly complex stations<br />

such as remote I/Os <strong>and</strong> even connected field devices.<br />

Several views are available to the user to help him with his tasks:<br />

Hardware project view<br />

Process device network view (preferably for st<strong>and</strong>-alone application)<br />

Process device plant view as TAG-related view, also with dis-<br />

Tel.: +49 180 50 50 222<br />

Fax: +49 180 50 50 223<br />

E-mail: adsupport@siemens.com<br />

Asia/Pacific<br />

Tel.: +86 1064 719 990<br />

Fax: +86 1064 747 474<br />

E-mail: adsupport.asia@siemens.com<br />

America<br />

play of diagnosis information<br />

Tel.: +1 423 262 2522<br />

Parameter view for parameterizing the field devices<br />

Lifelist view for commissioning <strong>and</strong> service<br />

Fax: +1 423 262 2289<br />

E-mail: simatic.hotline@sea.siemens.com<br />

4/16<br />

<strong>Siemens</strong> ST PCS 7 · October 2004


<strong>Engineering</strong> system<br />

ES software SIMATIC PDM<br />

SIMATIC PDM package for PCS 7<br />

■ Overview<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

SIMATIC PDM Starter Package<br />

V5.2 for SIMATIC PCS 7<br />

Preferred version for<br />

SIMATIC PCS 7, in 5 languages<br />

(German, English, French, Italian<br />

<strong>and</strong> Spanish), with<br />

Basic software for SIMATIC PDM<br />

(incl. communication through<br />

PROFIBUS DP/PA, HART modem<br />

<strong>and</strong> RS 232)<br />

Integration in STEP 7 / PCS 7<br />

Routing through S7-400<br />

128 TAGs<br />

SIMATIC PDM documentation<br />

SIMATIC PDM TAG options<br />

6ES7 658-3PX05-0YC0 C)<br />

Parameter view of SIMATIC PDM with curve <strong>and</strong> online display<br />

Power Pack<br />

The SIMATIC PDM package for PCS 7 is integrated in the engineering<br />

system of SIMATIC PCS 7 as a tool for the configuration,<br />

From 128 TAGs to 512 TAGs<br />

From 512 TAGs to 1024 TAGs<br />

6ES7 658-3XB05-2XD5<br />

6ES7 658-3XC05-2XD5<br />

parameterization, commissioning, diagnostics <strong>and</strong> servicing of<br />

intelligent process devices. Using a SIMATIC PDM Starter Package<br />

PCS 7, the latter can be custom-configured with the option<br />

"Communication through St<strong>and</strong>ard HART Multiplexers" <strong>and</strong> ad-<br />

From 1024 TAGs to 2048 TAGs<br />

From 2048 TAGs to TAGs unlimited<br />

6ES7 658-3XD05-2XD5<br />

6ES7 658-3XH05-2XD5<br />

ditional TAG options.<br />

Supplementary Software<br />

■ Design<br />

Communication through st<strong>and</strong>ard<br />

HART multiplexer<br />

6ES7 658-3EX00-2XD0<br />

SIMATIC PDM Starter Package PCS 7<br />

This is a SIMATIC PDM bundle for projects with up to 128 TAGs,<br />

which is optimized for integration in the central engineering system<br />

of SIMATIC PCS 7 or in STEP 7. In addition to the "SIMATIC<br />

PDM Basic Software" it already contains the options "Integration<br />

in 1 language (English)<br />

Demo Software<br />

SIMATIC PDM Demo V5.2<br />

In 5 languages (German, English,<br />

French, Italian <strong>and</strong> Spanish)<br />

6ES7 658-3GX05-0YC8 C)<br />

in STEP 7/PCS 7" <strong>and</strong> "Routing through S7-400" (for details of Update<br />

these software components see the section "SIMATIC PDM<br />

St<strong>and</strong>-alone Version").<br />

SIMATIC PDM Update from V5.1<br />

to V5.2<br />

6ES7 658-3AX05-0YC3 C)<br />

SIMATIC PDM Option<br />

in 5 languages (German, English,<br />

Communication through St<strong>and</strong>ard HART Multiplexer<br />

French, Italian <strong>and</strong> Spanish),<br />

works on basic software, all com-<br />

This option enables SIMATIC PDM to use the HART OPC server binations of the supplementary<br />

for communicating with HART field devices through HART multiplexers.<br />

software <strong>and</strong> the PDM starter<br />

package<br />

TAG options<br />

With TAG options it is possible to increase the number of project<br />

TAGs already integrated in the SIMATIC PDM Basic Software. Licenses<br />

for 512, 1,024, 2,048 <strong>and</strong> unlimited TAGs are available.<br />

One TAG corresponds to one SIMATIC PDM object, which represents<br />

individual field devices or components within a project,<br />

e.g. measuring devices, positioners, switching devices or remote<br />

I/Os. TAGs are also relevant for diagnosis with the lifelist of<br />

SIMATIC PDM. In this case, TAGs are considered to be all recognized<br />

devices with diagnostics capability, whose detailed diagnosis<br />

is effected through the device description (EDD).<br />

C) Subject to export regulations: AL: N, ECCN: EAR99S<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

4/17<br />

4


4<br />

<strong>Engineering</strong> system<br />

ES software SIMATIC PDM<br />

SIMATIC PDM st<strong>and</strong>-alone version<br />

■ Overview<br />

PDM Lifelist with status <strong>and</strong> diagnostics display<br />

SIMATIC PDM can be operated as a st<strong>and</strong>-alone version on a<br />

PC/PG/notebook independently of SIMATIC PCS 7.<br />

■ Design<br />

The product structure is designed to enable you to put together<br />

the SIMATIC PDM individually in accordance with the functionality<br />

you actually need:<br />

SIMATIC PDM Basic Software<br />

This is the basic block with all the functions required for operating<br />

<strong>and</strong> parameterizing the devices <strong>and</strong> with the communication<br />

routes enabled for PROFIBUS DP/PA, HART communication<br />

(Modem, RS 232 <strong>and</strong> PROFIBUS) <strong>and</strong> Modbus. The SIMATIC<br />

PDM Basic Software can manage projects with as many as<br />

4 TAGs <strong>and</strong> provided the system requirements are met it can be<br />

used for st<strong>and</strong>-alone operation on any computers (PCs/notebooks)<br />

with local connection to bus segments or direct connection<br />

to the device.<br />

SIMATIC PDM Option Integration in STEP 7/PCS 7<br />

This option is required for using SIMATIC PDM within a SIMATIC<br />

S7 or SIMATIC PCS 7 project with local connection to the<br />

PROFIBUS. SIMATIC PDM can thus be started directly from the<br />

hardware project (HW-Config).<br />

SIMATIC PDM Option Routing through S7-400<br />

This option is required as an add-on to the option "Integration in<br />

STEP7/PCS 7" when SIMATIC PDM is to be used in a central engineering<br />

system for SIMATIC S7/PCS 7 with Ethernet bus link to<br />

the automation systems for the plant-wide configuration, parameterization,<br />

commissioning <strong>and</strong> diagnosis of the devices in the<br />

field.<br />

4/18<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

SIMATIC PDM Option Communication through St<strong>and</strong>ard<br />

HART Multiplexer<br />

This option enables SIMATIC PDM to use the HART OPC server<br />

for communicating with HART field devices through HART multiplexers.<br />

TAG options<br />

With TAG options it is possible to increase the number of project<br />

TAGs already integrated in the SIMATIC PDM Basic Software. Licenses<br />

for 128, 512, 1,024, 2,048 <strong>and</strong> unlimited TAGs are available.<br />

One TAG corresponds to one SIMATIC PDM object, which<br />

represents individual field devices or components within a<br />

project, e.g. measuring devices, positioners, switching devices<br />

or remote I/Os. TAGs are also relevant for diagnosis with the lifelist<br />

of SIMATIC PDM. In this case, TAGs are considered to be all<br />

recognized devices with diagnostics capability, whose detailed<br />

diagnosis is effected through the device description (EDD).<br />

■ Technical specifications<br />

Requirements for st<strong>and</strong>-alone operation<br />

Hardware PG/PC/notebook with processor<br />

in accordance with the operating<br />

system requirements<br />

256 Mbyte main memory <strong>and</strong><br />

higher<br />

210 Mbyte free memory on hard<br />

disk <strong>and</strong> higher<br />

Operating system (alternative) Microsoft Windows 95c<br />

Microsoft Windows 98 SE<br />

Microsoft Windows ME<br />

Microsoft Windows NT 4.0 Workstation<br />

with SP6a or higher<br />

Microsoft Windows 2000 Professional<br />

with SP1 or higher<br />

Microsoft Windows XP Professional<br />

with SP1 or higher<br />

More software components<br />

SIMATIC PDM without STEP 7 SIMATIC Manager V5.2 (included<br />

on SIMATIC PDM CD)<br />

SIMATIC PDM integrated in STEP 7 V5.0 or higher with Ser-<br />

STEP 7<br />

vice Pack 4 or higher, to be<br />

ordered separately


■ Selection <strong>and</strong> Ordering Data Order No.<br />

SIMATIC PDM Basic Software<br />

V5.2<br />

Basic software for the operation<br />

<strong>and</strong> parameterization of process<br />

devices <strong>and</strong> components, in<br />

5 languages (German, English,<br />

French, Italian <strong>and</strong> Spanish), incl.<br />

communication through HART<br />

modem,<br />

communication through RS 232,<br />

communication through<br />

PROFIBUS DP/PA<br />

4 TAGs<br />

SIMATIC PDM documentation<br />

Supplementary Software<br />

Extensions to SIMATIC PDM basic<br />

software<br />

6ES7 658-3AX05-0YC0 C)<br />

Integration in STEP 7 /<br />

SIMATIC PCS 7<br />

is only required if it is intended to<br />

use the integration of SIMATIC<br />

PDM in HW Config<br />

in 5 languages (German, English,<br />

French, Italian <strong>and</strong> Spanish)<br />

6ES7 658-3BX00-2XD0<br />

Routing through S7-400<br />

In 5 languages (German, English,<br />

French, Italian <strong>and</strong> Spanish)<br />

6ES7 658-3CX00-2XD0<br />

Communication through st<strong>and</strong>ard<br />

HART multiplexer<br />

in 1 language (English)<br />

SIMATIC PDM TAG options<br />

6ES7 658-3EX00-2XD0<br />

Up to 128 TAGs 6ES7 658-3XA00-2XD0<br />

Up to 512 TAGs 6ES7 658-3XB00-2XD0 C)<br />

Up to 1,024 TAGs 6ES7 658-3XC00-2XD0<br />

Up to 2,048 TAGs<br />

Power Packs<br />

6ES7 658-3XD00-2XD0<br />

- From 128 TAGs to 512 TAGs 6ES7 658-3XB05-2XD5<br />

- From 512 TAGs to 1024 TAGs 6ES7 658-3XC05-2XD5<br />

- From 1024 TAGs to 2048 TAGs 6ES7 658-3XD05-2XD5<br />

- From 2048 TAGs to TAGs unlimited<br />

6ES7 658-3XH05-2XD5<br />

<strong>Engineering</strong> system<br />

ES software SIMATIC PDM<br />

SIMATIC PDM st<strong>and</strong>-alone version<br />

■ Selection <strong>and</strong> Ordering Data<br />

Demo Software<br />

Order No.<br />

SIMATIC PDM Demo Version<br />

V5.2<br />

In 5 languages (German, English,<br />

French, Italian <strong>and</strong> Spanish)<br />

Update<br />

6ES7 658-3GX05-0YC8 C)<br />

SIMATIC PDM Update from V5.1<br />

to V5.2<br />

in 5 languages (German, English,<br />

French, Italian <strong>and</strong> Spanish),<br />

works on all combinations of supplementary<br />

software <strong>and</strong> options<br />

6ES7 658-3AX05-0YC3 C)<br />

C) Subject to export regulations: AL: N, ECCN: EAR99S<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

4/19<br />

4


4<br />

<strong>Engineering</strong> system<br />

Supplementary ES software<br />

Controller optimization<br />

■ Overview<br />

The PCS 7 PID-Tuner can be used for the CTRL_PID <strong>and</strong><br />

CTRL_S software controllers. With the PCS 7 PID-Tuner function<br />

integrated in the CFC it is possible to determine the optimum<br />

control parameters for the PID, PI <strong>and</strong> P controllers of a loop in<br />

defined steps.<br />

Simulation with S7-PLCSIM<br />

■ Overview<br />

Overview simulation software for SIMATIC PCS 7<br />

4/20<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

The tool can be used to optimize controlled systems with <strong>and</strong><br />

without an integral component. Optimization can be carried out<br />

in manual or automatic mode. The transient response of the controllers<br />

with the determined controller parameters can be<br />

checked by carrying out step changes. The derived parameters<br />

can be saved <strong>and</strong> recalled as required.<br />

During determination of the controller parameters, the typical<br />

controller values (actual value, setpoint, manipulated variable)<br />

can be recorded using a curve function.<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

PCS 7 PID Tuner<br />

6ES7 653-0SP06-2YB0<br />

single license<br />

Controller optimization; options<br />

package for CFC<br />

trilingual (German, English,<br />

French)<br />

Software on PCS 7 Toolset CDs,<br />

electronic documentation on<br />

PCS 7 Documentation CD<br />

Type of delivery:<br />

Certificate of license <strong>and</strong> authorization<br />

diskette;<br />

For further programs concerning controller optimization, see the catalog<br />

"Add Ons for the SIMATIC PCS 7 Process Control <strong>System</strong>“.<br />

Using the S7-PLCSIM simulation software, user programs created<br />

with CFC/SFC can be tested on a PG/PC, regardless of<br />

whether the target hardware is available. The detection <strong>and</strong><br />

elimination of errors is thus brought forward into an early phase<br />

of development. This results in faster commissioning, lower<br />

costs <strong>and</strong> better program quality.<br />

■ Function<br />

S7-PLCSIM simulates a SIMATIC S7 CPU with its associated process<br />

images. The program to be tested is loaded into the simulated<br />

S7 CPU in the same way as for a real CPU, <strong>and</strong> is executed<br />

there. S7-PLCSIM is fully integrated in STEP 7. Process values<br />

can be exchanged between S7-PLCSIM <strong>and</strong> other Windows applications<br />

through an interface.<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

S7-PLCSIM<br />

Functional testing of programs<br />

which were created with<br />

CFC/SFC, on PC/PG<br />

in 5 languages (German, English,<br />

French, Spanish, Italian)<br />

Type of delivery:<br />

Certificate of license <strong>and</strong> authorization<br />

diskette;<br />

software <strong>and</strong> electronic documentation<br />

on CD<br />

Single license 6ES7 841-0CC03-0YE0<br />

Upgrade to V5 6ES7 841-0CC03-0YE4<br />

Software Update Service 6ES7 841-0CA01-0YX2<br />

For further programs concerning testing <strong>and</strong> simulation, see the catalog<br />

"Add Ons for the SIMATIC PCS 7 Process Control <strong>System</strong>“.


Operator <strong>System</strong><br />

5/2 Introduction<br />

5/4 OS hardware<br />

5/4 Introduction<br />

5/5 OS basic hardware<br />

5/7 Signal output<br />

5/8 OS software<br />

5/8 Introduction<br />

5/10 OS software for single station/<br />

server/client<br />

5/11 OS archiving<br />

5/12 StoragePlus<br />

5/13 SFC visualization<br />

5/13 SIMATIC Safety Matrix Viewer<br />

5/14 Connectivity Pack <strong>and</strong><br />

Client Access Licences<br />

5/15 Redundant operator systems<br />

5/15 OS redundancy<br />

<strong>Siemens</strong> ST PCS 7 · October 2004


5<br />

Operator system<br />

Introduction<br />

■ Overview<br />

Operator interface of the OS process control system with freely positionable<br />

windows<br />

The operator system is the human-machine interface of the SI-<br />

MATIC PCS 7 process control system, <strong>and</strong> thus represents the<br />

user’s window into the process. It is extremely flexible, <strong>and</strong> can<br />

be easily adapted to different plant architectures <strong>and</strong> customer<br />

requirements.<br />

The basis is formed by perfectly coordinated operator stations<br />

for single-user systems <strong>and</strong> for multi-user systems with client/server<br />

architecture.<br />

The system software of the operator stations is available in different<br />

levels based on the number of process objects (PO) used:<br />

250, 2,000, 3,000 or 5,000 POs per OS single station<br />

250, 2,000, 3,000, 5,000 or 8,500 POs per OS server<br />

The number of POs can be increased at any time by means of<br />

PowerPacks to allow for higher requirements or system expansions.<br />

5/2<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

■ Benefits<br />

7 Flexible, modular architecture with scalable hardware <strong>and</strong><br />

software components for single-user <strong>and</strong> multi-user systems<br />

7 High-performance operator stations based on st<strong>and</strong>ard<br />

PC technology with Microsoft Windows 2000 can be used in<br />

office or industrial environments<br />

7 Client/server multi-user systems with up to 12 OS servers/<br />

pairs of servers, each for 5,000 process objects <strong>and</strong> up to<br />

32 OS clients per server/pair of servers<br />

7 High-performance archive system based on Microsoft SQL<br />

server with cyclic archives <strong>and</strong> integral data backup, optionally<br />

with archive server<br />

7 OS health check for monitoring important server applications<br />

7 Online modifications without interrupting runtime operations,<br />

<strong>and</strong> online testing with selective loading of redundant servers<br />

7 Optimized AS/OS communication:<br />

AS reply cycle can be 500 ms, but with data transmission only<br />

after change of data; suppression of nuisance alarms<br />

7 User-friendly process control <strong>and</strong> higher operational reliability,<br />

also in conjunction with multi-screen technology<br />

7 Extended status display through the combination of status<br />

<strong>and</strong> analog values with alarm information<br />

7 Alarm priorities as additional attribute for filtering important<br />

messages<br />

7 Central user management, access control, electronic signature<br />

7 Sign-of-life system status monitoring for subordinate systems<br />

connected to the plant bus<br />

7 <strong>System</strong>-side time synchronization based on UTC (Universal<br />

Time Coordinated)


■ Technical specifications<br />

Definitions<br />

Process object<br />

(PO)<br />

A process object (PO) is a synonym for an operable<br />

<strong>and</strong> observable block with approx. 30 OS variables. It<br />

allows comparison of the quantity framework data of<br />

the engineering system with those of the operator system.<br />

OS Variable An OS variable is a required, defined main memory<br />

location for operating <strong>and</strong> monitoring with the operator<br />

system, which values are read to <strong>and</strong> from.<br />

Measuring<br />

point<br />

The measuring point identifies all the functional units<br />

<strong>and</strong> processing functions (e.g. TIRCAS+: temperature<br />

display, registration, control, alarm <strong>and</strong> switching point<br />

up) required for implementing an automation or process<br />

control task for a process variable (e.g. temperature,<br />

filling level). It has at least one process contact<br />

point <strong>and</strong> is also the point in the plant/process at which<br />

the automation becomes effective through information<br />

acceptance, processing our output actions. In<br />

SIMATIC PCS 7, measuring points are represented by<br />

CFC plans for the basic automation of a special process<br />

control task, e.g. level control - as well as matching<br />

faceplates <strong>and</strong> block symbols for operation <strong>and</strong><br />

monitoring over an operator system.<br />

The number of OS variables belonging to a measuring<br />

point depends on the type of measuring point, i.e. on<br />

the respective process control task. By definition, a<br />

measuring point comprises an average of 50 OS variables,<br />

whereby motors, valves, etc. require fewer <strong>and</strong><br />

controls <strong>and</strong> dosing rates require more variables.<br />

Process objects Measuring points OS Variables<br />

250 160 8,192 (8K)<br />

2.000 1.300 65,536 (64K)<br />

3.000 2.000 102,400 (100K)<br />

5.000 3.000 153,600 (150K)<br />

8.500 5.000 262,144 (256K)<br />

OS quantity framework<br />

Max. number of OS servers / pairs<br />

of servers<br />

Max. number of automation systems<br />

per OS server / pair of servers<br />

Max. number of OS clients<br />

in multi-client mode 1)<br />

(per multi-user system)<br />

Max. number of monitors per operator<br />

station in multi-channel operation<br />

Operator system<br />

1) If every OS client has access to all OS servers/pairs of servers<br />

12<br />

64<br />

32<br />

4<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

Introduction<br />

Max. number of OS areas 64<br />

Number of faceplates per control 1 to 16 (adjustable)<br />

window<br />

Number of trends per trends win- 10<br />

dow<br />

Select time OS area display < 2 s<br />

(100 process symbols)<br />

Max. number of variables/process<br />

objects:<br />

per OS single station 150K / 5,000 POs<br />

per OS server 256K / 8,500 POs<br />

Max. number of configurable indi- 50.000<br />

cations per server<br />

Number of measuring points<br />

per OS single station approx. 3,000<br />

per OS server approx. 5,000<br />

per multi-user system approx. 60,000<br />

High-performance archive system<br />

(cyclic buffer), based on Microsoft<br />

SQL server, for:<br />

Process value archiving in the OS approx. 1,000/s<br />

server<br />

Process value archiving with ar- approx. 5,000/s<br />

chive server<br />

Indications (per server) Steady-state load approx. 10/s<br />

Message peak approx. 3,000 / 4 s<br />

Max. number of archive variables 80.000<br />

(with archive server)<br />

5/3<br />

5


5<br />

Operator system<br />

OS hardware<br />

Introduction<br />

■ Overview<br />

All operator stations are based on st<strong>and</strong>ard PC technology combined<br />

with the Microsoft Windows 2000 operating system. PCs<br />

are offered with different performance levels, which have been<br />

optimized for different functions such as OS single station,<br />

OS client or OS server. The use of st<strong>and</strong>ard components <strong>and</strong> interfaces<br />

from the PC world means that the operator stations are<br />

open for customer <strong>and</strong> sector-specific options <strong>and</strong> expansions.<br />

They can be used in harsh industrial environments as well as in<br />

the office. OS single stations <strong>and</strong> OS clients can be installed<br />

with Multi-VGA graphic cards to permit the process control of<br />

several different plant areas using up to 4 monitors.<br />

■ Design<br />

Single-user system (OS single station)<br />

In a single-user system architecture, all operation <strong>and</strong> monitoring<br />

functions for a complete project (plant/unit) are concentrated<br />

in one station. A FastEthernet RJ45 port is already on board <strong>and</strong><br />

can be used for connecting to an OS LAN (terminal bus). The OS<br />

single station can be connected to the Industrial Ethernet bus in<br />

two ways:<br />

through a CP 1613 communications processor (communication<br />

with max. 64 automation systems) or<br />

through a st<strong>and</strong>ard LAN card (Basic Communication Ethernet<br />

for communication with max. 8 automation systems).<br />

The OS single station can be operated on the plant bus in parallel<br />

with other single-user systems or with a multi-user system architecture.<br />

By using the WinCC/Redundancy program package<br />

it is also possible to operate two OS single stations with redundant<br />

architecture.<br />

Multi-user system with client/server architecture<br />

A multi-user system consists of operator terminals (OS clients),<br />

which receive data (project data, process values, archives,<br />

alarms <strong>and</strong> messages) from one or more OS servers through an<br />

OS LAN (Local Area Network). The OS LAN can share the transmission<br />

medium with the plant bus or it can be designed as a<br />

separate bus (Ethernet with TCP/IP).<br />

5/4<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

In this architecture, redundant OS servers may be set up to meet<br />

higher availability requirements (hot st<strong>and</strong>by). Critical applications<br />

running on the OS server are monitored by Health Check<br />

for software faults. If a fault is detected, switchover to the redundant<br />

system is triggered. Synchronization of the redundant O<br />

servers takes place automatically <strong>and</strong> at high speed.<br />

OS clients can access the data of not only one OS server/server<br />

pair, but from several OS servers/pairs of servers simultaneously<br />

(multi-client mode). This makes it possible to subdivide a plant<br />

into technological units <strong>and</strong> to distribute the data accordingly to<br />

several OS servers/pairs of servers. In addition to scalability, the<br />

advantage of distributed systems is the ability to decouple plant<br />

areas from each other, which results in higher availability.<br />

SIMATIC PCS 7 supports multi-user systems with up to<br />

12 OS servers or 12 redundant OS pairs of servers. In multi-client<br />

mode, OS clients can access data from one or more of the<br />

12 OS servers/pairs of servers in parallel (up to 32 OS clients simultaneously<br />

on all).<br />

The OS servers are designed in addition with client functions<br />

which permit them to access the data (archives, messages,<br />

tags, variables) from the other OS servers of in the multi-user<br />

system. This means that process graphics on one OS server can<br />

also be linked with variables on other OS servers (area-independent<br />

displays).<br />

Like the OS single stations, the OS servers can be connected to<br />

the Industrial Ethernet plant bus using a communications processor<br />

or a st<strong>and</strong>ard LAN card. A FastEthernet RJ45 port is already<br />

on board <strong>and</strong> can be used for connecting to an OS LAN<br />

(terminal bus).<br />

Additional Archive Server<br />

An operator system may be equipped with an additional, preferably<br />

redundant archive server for process values. Using such an<br />

archive server it is possible to archive approx. 5,000 process<br />

values/s. The archive server is a station on the OS LAN <strong>and</strong> is not<br />

connected to the plant bus. A FastEthernet RJ45 port is already<br />

on board <strong>and</strong> can be used for connecting to the OS LAN.


Operator system<br />

OS hardware<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

OS basic hardware<br />

■ Overview<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

The full range of basic hardware presented in the chapter OS Server<br />

"ES/OS/Batch/IT basic devices" is available for the configuration<br />

of operator systems. This basic hardware may be exp<strong>and</strong>ed with<br />

the following options, depending on the customer’s particular requirements<br />

<strong>and</strong> whether the hardware is used as OS single station,<br />

OS server, archive server or OS client:<br />

SIMATIC PC in rack of 19“ design,<br />

Pentium 4 with 2.8 GHz <strong>and</strong> more,<br />

1 Gbyte RAM (2 x 512 Mbyte),<br />

sound, EIDE-RAID 1 with 2 hard<br />

disks of 120 Gbyte, graphics controller<br />

on board with Dynamic<br />

Hardware <strong>and</strong> software components for redundant operations<br />

Multi-VGA graphics card for connection of up to 4 monitors<br />

Video Memory, DVD-ROM IDE,<br />

mouse,<br />

FastEthernet RJ45 on board for<br />

Display <strong>and</strong> CRT monitors for office <strong>and</strong> industrial environments<br />

(see the chapter "ES/OS/Batch/IT basic devices")<br />

Signal module for acoustic <strong>and</strong> visual signalling of messages<br />

connection to OS-LAN,<br />

without monitor, keyboard <strong>and</strong><br />

printer,<br />

Windows 2000 Server MUI (Ger-<br />

Chipcard reader for access security<br />

man, English, French, Italian,<br />

Spanish);<br />

SIMATIC PCS 7 preinstalled <strong>and</strong><br />

The archive server is only a station in the OS-LAN, <strong>and</strong> therefore<br />

available only in the st<strong>and</strong>ard version with BCE communication.<br />

on restore DVD<br />

PCS 7 OS Server IL 40 S V2<br />

BCE<br />

Connection to system bus<br />

through Basic Communication<br />

6ES7 650-0GE06-0YX0 D)<br />

Upgrading from BCE to CP 1613 communication<br />

OS single stations <strong>and</strong> OS servers with BCE communication can<br />

be subsequently upgraded for communication with CP 1613.<br />

Items required:<br />

Ethernet (BCE) with FastEthernet<br />

RJ45 network card (PCI card)<br />

PCS 7 OS Server IL 40 S V2 IE<br />

Connection to system bus<br />

through Industrial Ethernet with<br />

6ES7 650-0GE16-0YX0 D)<br />

CP 1613:<br />

PCI card for connecting to Industrial Ethernet<br />

CP 1613 communications processor<br />

S7-1613:<br />

Software for S7 communication for CP 1613<br />

Archive server<br />

SIMATIC PC in rack of 19“ design,<br />

Pentium 4 with 2.8 GHz <strong>and</strong> more,<br />

■ Technical specifications<br />

1 Gbyte RAM (2 x 512 Mbyte),<br />

sound, EIDE-RAID 1 with 2 hard<br />

disks of 120 Gbyte, graphics con-<br />

Detailed technical data for single stations, clients <strong>and</strong> servers troller on board with Dynamic<br />

are provided in table form in the chapter "ES/OS/BATCH/IT basic Video Memory, DVD-ROM IDE,<br />

devices".<br />

mouse,<br />

FastEthernet RJ45 on board,<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

without monitor, keyboard <strong>and</strong><br />

printer,<br />

Windows 2000 Server MUI (Ger-<br />

OS Single Station<br />

man, English, French, Italian,<br />

SIMATIC PC in rack of 19“ design,<br />

Spanish);<br />

Pentium 4 with 2.8 GHz <strong>and</strong> more,<br />

SIMATIC PCS 7 preinstalled <strong>and</strong><br />

1 Gbyte RAM (2 x 512 Mbyte),<br />

on restore DVD<br />

sound, EIDE-RAID 1 with 2 hard<br />

disks of 120 Gbyte, graphics controller<br />

on board with Dynamic<br />

Video Memory, DVD±RW IDE,<br />

mouse,<br />

FastEthernet RJ45 on board for<br />

PCS 7 OS Server IL 40 S V2<br />

BCE<br />

With Basic Communication Ethernet<br />

(BCE) based on FastEthernet<br />

RJ45 network card (PCI card)<br />

6ES7 650-0GE06-0YX0 D)<br />

connection to OS-LAN,<br />

without monitor, keyboard <strong>and</strong><br />

printer,<br />

Windows 2000 Professional MUI<br />

(German, English, French, Italian,<br />

Spanish);<br />

SIMATIC PCS 7 preinstalled <strong>and</strong><br />

on restore DVD<br />

B) Subject to export regulations: AL: N, ECCN: EAR99H<br />

PCS 7 ES/OS IL 40 S V2 BCE<br />

Connection to system bus<br />

through Basic Communication<br />

Ethernet (BCE) with FastEthernet<br />

RJ45 network card (PCI card)<br />

6ES7 650-0GC06-0YX0 D)<br />

PCS 7 ES/OS IL 40 S V2 IE<br />

Connection to system bus<br />

through Industrial Ethernet with<br />

CP 1613 communications processor<br />

6ES7 650-0GC16-0YX0 D)<br />

5/5<br />

5


5<br />

Operator system<br />

OS hardware<br />

OS basic hardware<br />

■ Selection <strong>and</strong> Ordering Data<br />

OS Client<br />

Order No.<br />

PCS 7 OS Client IL 40 S V2<br />

SIMATIC PC in rack of 19“ design,<br />

Pentium 4 with 2.8 GHz <strong>and</strong> more,<br />

512 Mbyte RAM (2 x 256 Mbyte),<br />

sound, EIDE hard disk 80 of<br />

80 Gbyte, graphics controller on<br />

board with Dynamic Video Memory,<br />

DVD-ROM IDE, optical<br />

mouse,<br />

FastEthernet RJ45 on board for<br />

connection to OS-LAN,<br />

without monitor, keyboard <strong>and</strong><br />

printer,<br />

Windows 2000 Professional MUI<br />

(German, English, French, Italian,<br />

Spanish);<br />

SIMATIC PCS 7 preinstalled <strong>and</strong><br />

on restore DVD<br />

Upgrade from BCE to CP 1613<br />

Communication<br />

6ES7 650-0GD06-0YX0 D)<br />

CP 1613<br />

PCI card for connection to Industrial<br />

Ethernet, with AUI/ITP <strong>and</strong><br />

RJ45 connections<br />

6GK1 161-3AA00<br />

S7-1613 for Industrial Ethernet<br />

S7 communication software for<br />

CP 1613,<br />

can be used with<br />

Windows 2000/XP<br />

Single license for 1 installation,<br />

runtime software, software <strong>and</strong><br />

electronic manual on CD-ROM,<br />

license key on diskette, Class A,<br />

bilingual (German/English)<br />

6GK1 716-1CB62-3AA0 D)<br />

5/6<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

■ Selection <strong>and</strong> Ordering Data<br />

Additional <strong>and</strong> expansion components<br />

Order No.<br />

Multi-VGA Graphics Card<br />

"2 Screens"<br />

for operating 2 process monitors<br />

on 1 station<br />

Type of delivery:<br />

Dual graphics card, driver CD,<br />

manual, 1 dual DVI cable for<br />

2 digital outputs, 2 adapters for<br />

VGA outputs<br />

6ES7 652-0XX03-1XE0 B)<br />

Multi-VGA Graphics Card<br />

"4 Screens"<br />

for operating 4 process monitors<br />

on 1 station<br />

Type of delivery:<br />

Quad graphics card, driver CD,<br />

manual, 2 dual DVI cables for<br />

4 digital outputs, 4 adapters for<br />

VGA outputs<br />

Utility software<br />

SIMATIC PC/PG Image & Partition<br />

Creator<br />

Software for creating hard disk<br />

images <strong>and</strong> for configurating hard<br />

disk partitions<br />

Memory modules for exp<strong>and</strong>ing<br />

the main memory<br />

Memory expansion kit 512<br />

Mbyte (Dual Channel) for SI-<br />

MATIC Rack PC IL 40 S V2 (2 x<br />

256 Mbyte DDR SDRAM)<br />

Memory expansion kit 1 Gbyte<br />

(Dual Channel) for SIMATIC<br />

Rack PC IL 40 S V2 (2 x<br />

512 Mbyte DDR SDRAM)<br />

Memory expansion kit 2 Gbyte<br />

(Dual Channel) for SIMATIC<br />

Rack PC IL 40 S V2 (2 x 1 Gbyte<br />

DDR SDRAM)<br />

6ES7 652-0XX03-1XE1 B)<br />

6ES7 648-6AA02-0YX0 B)<br />

6ES7 648-2AD30-0FB0 B)<br />

6ES7 648-2AD40-0FB0 B)<br />

6ES7 648-2AD50-0FB0 B)<br />

TK 200 keyboard (PS/2 connection)<br />

German key assignment 6GF6 710-1AA<br />

International key assignment 6GF6 710-1BA<br />

SIMATIC PC keyboard (USB<br />

connection)<br />

International key assignment 6ES7 648-0CB00-0YA0<br />

3-m power cable for Rack PC 1)<br />

For Great Britain 6ES7 900-0BA00-0XA0<br />

For Switzerl<strong>and</strong> 6ES7 900-0CA00-0XA0<br />

For USA 6ES7 900-0DA00-0XA0<br />

For Italy 6ES7 900-0EA00-0XA0<br />

B) Subject to export regulations: AL: N, ECCN: EAR99H<br />

D) Subject to export regulations: AL: N, ECCN: 5D992B1<br />

1) The PCS 7 systems are delivered as st<strong>and</strong>ard with a "European power<br />

cable". The country-specific versions listed above are required for some<br />

countries.<br />

Monitors, see chapter "ES/OS/BATCH/IT basic devices“


■ Overview<br />

OS single station <strong>and</strong> OS client can be exp<strong>and</strong>ed with a signal<br />

module. This signal module can operate a horn <strong>and</strong> up to 3 different<br />

lamps or buzzer sounds symbolizing different signal<br />

classes. Together with a hardware timer (watchdog) the signal<br />

module is able to detect <strong>and</strong> signal the failure of an operator station.<br />

A hardware acknowledge key can also be connected.<br />

The signal module occupies one PCI slot in the operator station.<br />

Operator system<br />

OS hardware<br />

B) Subject to export regulations: AL: N, ECCN: EAR99H<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

Signal output<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

PCI Signal Module<br />

PCI card for installing in an operator<br />

station<br />

6DS1 916-8RR B)<br />

Connecting cable<br />

For connecting an external audio<br />

detector to a signal module<br />

3 m 6XV2 175-8AH30<br />

10 m 6XV2 175-8AN10<br />

32 m 6XV2 175-8AN32<br />

50 m 6XV2 175-8AN50<br />

5/7<br />

5


5<br />

Operator system<br />

OS software<br />

Introduction<br />

■ Overview<br />

■ Function<br />

OS basic hardware <strong>and</strong> OS software are structured by OS single<br />

station, OS server <strong>and</strong> OS client in compliance with the architecture<br />

of the operator system <strong>and</strong> are accordingly coordinated in<br />

this regard.<br />

The optional archive server for process values is based on the<br />

starter software for OS server 250 PO/RT 8K with 512 variables.<br />

The size of the archive can be exp<strong>and</strong>ed by means of additive<br />

Archive PowerPacks to 1,500, 5,000, 30,000 or 80,000 variables.<br />

User Interface<br />

The predefined user interface of the operator system has all the<br />

features typical of a control system. It is multilingual, clearly<br />

structured, ergonomic <strong>and</strong> easy to underst<strong>and</strong>. The operator<br />

can survey the process extremely easily, <strong>and</strong> rapidly navigate<br />

between different views of the plant. He is supported by a picture<br />

tree manager, which organizes the picture hierarchy according<br />

to user requirements <strong>and</strong> permits direct selection of<br />

All operator stations can be equipped in addition with SFC visu-<br />

subordinate areas.<br />

alization.<br />

Process displays <strong>and</strong> measuring points can also be called up by<br />

■ Application<br />

name. An online language selector permits the user to change<br />

the display language dynamically during runtime.<br />

The OS software can be run on the OS basic hardware offered in<br />

this catalog <strong>and</strong> has been tested with it. <strong>Siemens</strong> guarantees the<br />

compatibility of hardware <strong>and</strong> software for system configurations<br />

based on components in this catalog.<br />

A st<strong>and</strong>ard view <strong>and</strong> a server view are available for the technological<br />

representation of a plant, each with variously designed<br />

area overviews. Features provided in both views include:<br />

Message line for display of last message<br />

Should you use basic hardware other than that offered in this cat- Date, time <strong>and</strong> name of the operator<br />

alog, please note the minimum requirements quoted in the chap- Area overview with up to 36/49/64 areas (depending on resoter<br />

"ES/OS/BATCH/IT basic devices".<br />

lution of the process monitor)<br />

If you configure your own SIMATIC PCS 7 operator station<br />

(OS single station/ OS server/ OS client) using other/own hard-<br />

Working area for plant displays <strong>and</strong> movable windows for<br />

faceplates, historic trends, etc.<br />

ware components, you carry full responsibility <strong>and</strong> will not receive<br />

any free support in the event of compatibility problems.<br />

Despite comprehensive tests it cannot be ruled out that the function<br />

of a SIMATIC PCS 7 system may be disturbed or impaired<br />

by additional non-system software, i.e. software not explicitly released<br />

for SIMATIC PCS 7. For this reason, <strong>Siemens</strong> AG warns<br />

against installing non-system software on SIMATIC PCS 7 runtime<br />

systems, <strong>and</strong> does not provide a warranty in the event of any<br />

resulting damage.<br />

Furthermore, the use of non-system software in the SIMATIC<br />

PCS 7 environment is your responsibility. You have no claims for<br />

free support in the event of compatibility problems.<br />

<strong>System</strong> function keys<br />

In a special message view it is possible to switch between control<br />

message pages such as new list, old list, cleared alarm list,<br />

operator action list, control element list <strong>and</strong> message history list.<br />

Trends can be displayed as a full-size picture or as a window in<br />

the working area. Some trends/trend groups are predefined during<br />

plant configuration. The operator is also able, however, to<br />

compile his own trends while online <strong>and</strong> to select them by measuring<br />

point name.<br />

5/8<br />

<strong>Siemens</strong> ST PCS 7 · October 2004


Messages / alarms<br />

Message priorities are issued as an additional attribute to the<br />

known signal classes in order to make it easier to assess large<br />

quantities of signals <strong>and</strong> to be better able to distinguish important<br />

messages from the less important.<br />

Active messages are signaled by group displays representing<br />

preconfigured views based on signal groups.<br />

The last message to have arrived - or the message with the highest<br />

priority when alarm priorities are utilized - is displayed at the<br />

top edge of the st<strong>and</strong>ard view. A predefined window with further<br />

messages can be called up with the "Extended message line“.<br />

The "Loop-in-alarm" <strong>and</strong> "Select display using measuring point"<br />

functions support the quick evaluation <strong>and</strong> resolution of faults.<br />

Using "Loop-in-alarm“, the operator can jump directly to the process<br />

display in which the fault has occurred, <strong>and</strong> can then call<br />

up the associated faceplate (loop display) through the measuring<br />

point.<br />

Flexible sound setting options support the audible annunciation<br />

of messages/alarms through a soundcard or by controlling external<br />

horns through a signal module.<br />

Operator system<br />

OS software<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

Introduction<br />

Central user management, access control <strong>and</strong> electronic<br />

signature<br />

(see the chapter "Administration")<br />

SIMATIC Logon offers central user administration with security<br />

<strong>and</strong> access control based on Windows 2000 for the SIMATIC<br />

PCS 7 system components as well as non-SIMATIC components<br />

connected through API. It can be used to fulfill the validation requirements<br />

of 21 CFR Part 11. An electronic signature function<br />

can also be used in conjunction with SIMATIC Logon.<br />

A chipcard reader can be used to provide an additional level of<br />

security for controlling access to the operator stations by checking<br />

the operator privileges stored on a chipcard.<br />

Sign-of-life monitoring<br />

With the "Sign-of-life monitoring function", the operator system is<br />

able to monitor the correct operation of all subordinate systems<br />

connected to the plant bus. A graphical plan configuration display<br />

shows the status of each monitored component.<br />

Time synchronization<br />

The operator system can implement time synchronization based<br />

on UTC (Universal Time Coordinated) (UTC), which is a st<strong>and</strong>ard<br />

feature within the SIMATIC PCS 7 process control system. This<br />

feature is especially beneficial for widely distributed plants<br />

present in different time zones, e.g. pipelines.<br />

Script languages<br />

Visual Basic <strong>and</strong> C are the scripting languages available for custom<br />

programming of OS applications.<br />

5/9<br />

5


5<br />

Operator system<br />

OS software<br />

OS software for single station/server/client<br />

■ Overview<br />

The OS software is adapted to the OS basic hardware (OS single<br />

station, OS server <strong>and</strong> OS client).<br />

The OS software for OS single stations <strong>and</strong> OS servers can be<br />

adapted to plants of various size by changing the number of process<br />

objects (PO). The number of POs can be increased at any<br />

time by adding more PowerPacks in order to allow for higher requirements<br />

of system expansions.<br />

The engineering of the SIMATIC PCS 7 process control system<br />

is usually concentrated in a separate engineering system. In the<br />

case of OS single stations used for small plants, engineering<br />

<strong>and</strong> operator functionality can be combined in one station, except<br />

in the case of redundant systems (engineering software,<br />

see the chapter "<strong>Engineering</strong> system").<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

OS Software Single Station V6.0<br />

Single license for 1 installation, trilingual<br />

(German/English/French)<br />

Electronic documentation on<br />

PCS 7 Toolset CDs <strong>and</strong> PCS 7<br />

Documentation CD<br />

Type of delivery:<br />

Certificate of license, authorization<br />

diskette, PCS 7 Toolset CDs<br />

<strong>and</strong> additional CDs with Service<br />

Pack 3 for Microsoft Windows<br />

2000 (in 5 languages), Microsoft<br />

Internet Explorer, Microsoft SQL<br />

Server 2000 <strong>and</strong> PC Anywhere<br />

250 POs/RT 8K<br />

D) Subject to export regulations: AL: N, ECCN: 5D992B1<br />

1) A process object (PO) is a synonym for an operable <strong>and</strong> observable block<br />

with approx. 30 variables.<br />

2) The upgrades OS Software Single <strong>and</strong> OS Software Server support a<br />

high-performance archive system for up to 512 variables. For large<br />

archives this volume can be extended using add-on OS Archive V6.0<br />

Power Packs (see OS Archiving). This applies regardless of whether a<br />

central process value archive server is used or not.<br />

1) OS Software Server Power Pack<br />

V6.0<br />

For exp<strong>and</strong>ing the OS software<br />

for servers<br />

Single license for 1 Installation<br />

trilingual (German, English,<br />

French)<br />

Type of delivery:<br />

Certificate of license <strong>and</strong> authorization<br />

diskette<br />

from 250 POs/RT 8K to 2,000<br />

POs/RT 64K<br />

6ES7 658-2BB06-0YD0<br />

from 2,000 POs/RT 64K to 3,000 6ES7 658-2BC06-0YD0<br />

POs/RT 100K<br />

from 3,000 POs/RT 100K to<br />

5,000 POs/RT 150K<br />

6ES7 658-2BD06-0YD0<br />

from 5,000 POs/RT 150K to 6ES7 658-2BE06-0YD0<br />

8,500 POs/RT 256K<br />

OS Software Client V6.0<br />

Single license for 1 installation ,<br />

trilingual (German, English,<br />

French)<br />

Electronic documentation on PCS<br />

7 Toolset CDs <strong>and</strong> PCS 7 Documentation<br />

CD<br />

6ES7 658-2CX06-0YA0 D)<br />

Type of delivery:<br />

Certificate of license, authorization<br />

diskette, PCS 7 Toolset CDs<br />

<strong>and</strong> additional CDs with Service<br />

6ES7 658-2AA06-0YA0 D)<br />

Pack 3 for Microsoft Windows<br />

2000 (in 5 languages), Microsoft<br />

2,000 POs/RT 64K<br />

3,000 POs/RT 100K<br />

5,000 POs/RT 150K<br />

6ES7 658-2AB06-0YA0<br />

6ES7 658-2AC06-0YA0<br />

6ES7 658-2AD06-0YA0<br />

D)<br />

D)<br />

D)<br />

Internet Explorer, Microsoft SQL<br />

Server 2000 <strong>and</strong> PC Anywhere<br />

Upgrade of operator software<br />

from V5.x to V6.0<br />

OS Software Single Station<br />

Single license for 1 installation ,<br />

Power Pack V6.0<br />

trilingual (German, English,<br />

For extending the OS software for<br />

French)<br />

a single station<br />

Electronic documentation on PCS<br />

Single license for 1 installation ,<br />

trilingual (German, English,<br />

7 Toolset CDs <strong>and</strong> PCS 7 Documentation<br />

CD<br />

French)<br />

Type of delivery:<br />

Type of delivery:<br />

Certificate of license <strong>and</strong> authorization<br />

diskette<br />

Certificate of license, authorization<br />

diskette, PCS 7 Toolset CDs<br />

<strong>and</strong> additional CDs with Service<br />

Pack 3 for Microsoft Windows<br />

from 250 POs/RT 8K to<br />

6ES7 658-2AB06-0YD0<br />

2000 (in 5 languages), Microsoft<br />

2,000 POs/RT 64K<br />

Internet Explorer, Microsoft SQL<br />

from 2,000 POs/RT 64K to 6ES7 658-2AC06-0YD0<br />

Server 2000 <strong>and</strong> PC Anywhere<br />

3,000 POs/RT 100K<br />

Upgrade of OS software for sin-<br />

from 3,000 POs/RT 100K to<br />

5,000 POs/RT 150K<br />

6ES7 658-2AD06-0YD0<br />

gle station with 2,000<br />

POs/RT 64K<br />

OS Software Server V6.0<br />

Single license for 1 installation ,<br />

trilingual (German, English,<br />

French)<br />

Electronic documentation on PCS<br />

7 Toolset CDs <strong>and</strong> PCS 7 Documentation<br />

CD<br />

Type of delivery:<br />

Certificate of license, authorization<br />

diskette, PCS 7 Toolset CDs<br />

<strong>and</strong> additional CDs with Service<br />

Pack 3 for Microsoft Windows<br />

2000 (in 5 languages), Microsoft<br />

Internet Explorer, Microsoft SQL<br />

Server 2000 <strong>and</strong> PC Anywhere<br />

250 POs/RT 8K 6ES7 658-2BA06-0YA0 D)<br />

2,000 POs/RT 64K 6ES7 658-2BB06-0YA0 D)<br />

3,000 POs/RT 100K 6ES7 658-2BC06-0YA0 D)<br />

5,000 POs/RT 150K 6ES7 658-2BD06-0YA0 D)<br />

8,500 POs/RT 256K 6ES7 658-2BE06-0YA0 D)<br />

2)<br />

6ES7 658-2AB06-0YE0 D)<br />

Upgrade of OS software for single<br />

station with 5,000<br />

POs/RT 150K 2)<br />

Upgrade of OS software for<br />

server 2,000 POs/RT 64K<br />

6ES7 658-2AD06-0YE0 D)<br />

2)<br />

Upgrade of OS software for<br />

server 5,000 POs/RT 150K<br />

6ES7 658-2BB06-0YE0 D)<br />

2)<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

6ES7 658-2BD06-0YE0 D)<br />

Upgrade of OS software for client 6ES7 658-2CX06-0YE0 D)<br />

5/10<br />

<strong>Siemens</strong> ST PCS 7 · October 2004


Operator system<br />

OS software<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

OS archiving<br />

■ Overview<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

A high-performance archive system based on Microsoft SQL OS Software Server V6.0<br />

6ES7 658-2BA06-0YA0 D)<br />

server technology can be configured online to save process val- Single license for 1 installation ,<br />

ues <strong>and</strong> messages in cyclic archives, <strong>and</strong> has an integral ar- trilingual (German, English,<br />

chive backup function for exporting <strong>and</strong> storing old data. The French)<br />

high-performance archive system is usually designed for up to Up to 512 variables<br />

512 variables. The number of variables can be increased with<br />

the help of add-on OS Archive Power Packs.<br />

Electronic documentation on PCS<br />

7 Toolset CDs <strong>and</strong> PCS 7 Docu-<br />

A central process value archive server based on the hardware of<br />

the OS server can be configured in addition with the st<strong>and</strong>ard<br />

software for the OS server (250 POs/RT 8K) <strong>and</strong> add-on OS Archive<br />

Power Packs.<br />

mentation CD<br />

Type of delivery:<br />

Certificate of license, authorization<br />

diskette, PCS 7 Toolset CDs<br />

<strong>and</strong> additional CDs with Service<br />

Archive servers for process values are operated preferably as<br />

redundant systems.<br />

Pack 3 for Microsoft Windows<br />

2000 (in 5 languages), Microsoft<br />

Internet Explorer, Microsoft SQL<br />

Server 2000 <strong>and</strong> PC Anywhere<br />

OS Archive V6.0 Power Pack<br />

Single license for 1 installation ,<br />

trilingual (German, English,<br />

French)<br />

Type of delivery:<br />

Certificate of license <strong>and</strong> authorization<br />

diskette<br />

from 512 to 1,500 variables 6ES7 658-2EA06-2YD0<br />

from 1,500 to 5,000 variables 6ES7 658-2EB06-2YD0<br />

from 5,000 to 30,000 variables 6ES7 658-2EC06-2YD0<br />

from 30,000 to 80,000 variables 6ES7 658-2ED06-2YD0<br />

D) Subject to export regulations: AL: N, ECCN: 5D992B1<br />

5/11<br />

5


5<br />

Operator system<br />

OS software<br />

StoragePlus<br />

■ Overview<br />

StoragePlus is a program package for the long-term archiving of<br />

measurement values, messages, reports <strong>and</strong> batch data of the<br />

SIMATIC PCS 7 V6.0 process control system. StoragePlus manages<br />

measurement values, messages <strong>and</strong> OS reports, which<br />

are swapped out of the OS archives, as well as batch data from<br />

SIMATIC BATCH in a central database. All these data can be visualized<br />

in graphic <strong>and</strong> clear manner using the Internet Explorer<br />

<strong>and</strong> be swapped out onto the storage media supported by the<br />

operating system.<br />

■ Application<br />

StoragePlus can be used for the long-term archiving of data from<br />

the SIMATIC PCS 7 V6.0 process control system. For this purpose<br />

StoragePlus has to be installed on a separate computer<br />

with Microsoft Windows 2000 (see "<strong>System</strong> Neutral Components",<br />

chapter "ES/OS/Batch/IT Basic Devices"), which is connected<br />

by OS-LAN/terminal bus to the OS <strong>and</strong> Batch Servers/<br />

single-station systems of the SIMATIC PCS 7 plant.<br />

StoragePlus manages the measurement values, messages <strong>and</strong><br />

OS reports which are swapped out of the OS archives, as well as<br />

batch data from SIMATIC BATCH, in a central database <strong>and</strong><br />

makes these data available independently of the PCS 7 runtime<br />

systems. All the data can be visualized in graphic <strong>and</strong> clear<br />

manner using the Internet Explorer. Data selection is supported<br />

by integrated filter functions. Messages <strong>and</strong> measurement values<br />

can be shown in table form, <strong>and</strong> measurement values also<br />

in graphic form. Tables of measurement values can be exported<br />

in CSV format for processing in other Windows applications, e.g.<br />

Microsoft Excel.<br />

The data managed by StoragePlus can be swapped out onto all<br />

the storage media supported by the operating system. This may<br />

require additional hardware <strong>and</strong> software, e.g. a DVD writer with<br />

suitable burning software.<br />

StoragePlus is able to read in data which were swapped out using<br />

Storage V5.2 <strong>and</strong> to convert the data into the SIMATIC PCS 7<br />

V6.0 data format.<br />

■ Function<br />

Archiving of messages, measurement values <strong>and</strong> reports of<br />

the SIMATIC PCS 7 V6.0 operator systems<br />

Archiving of batch data from SIMATIC BATCH V6.0<br />

Swapping out of all StoragePlus data onto external storage<br />

media<br />

Reading in of swapped-out StoragePlus data from external<br />

storage media<br />

Cataloging of all StoragePlus data<br />

Parameterizing of views (display windows <strong>and</strong> masks) incl. the<br />

selection criteria for displaying the data<br />

5/12<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

Visualizing of messages in table form dependent on filter functions<br />

Displaying of measurement values in table or graphic form dependent<br />

on filter functions<br />

Exporting of measurement values in CSV format, e.g. to Microsoft<br />

Excel<br />

Visualizing a batch overview (selecting the detailed protocol<br />

of a batch from the batch overview is possible)<br />

Web-based presentation of data<br />

Access protection with user-specific rights<br />

Migration of messages <strong>and</strong> measurement values from Storage<br />

V5.2<br />

■ Technical specifications<br />

StoragePlus<br />

Long-term archiving Up to 4 OS servers/server pairs<br />

simultaneously<br />

Max. data input (number of archive 400 /s<br />

values) per OS server<br />

Max. data input (number of archive 1,600 /s<br />

values) over all OS servers<br />

Max. data volume input capacity 500 Mbyte<br />

per day<br />

Hardware requirements<br />

Main memory 512 Mbyte <strong>and</strong> higher, 1 Gbyte<br />

recommended<br />

Hard disk memory recommended<br />

Security EIDE-RAID 1 with 2 hard disks for<br />

60 Gbyte <strong>and</strong> higher<br />

Capacity 2 hard disks for 60 Gbyte <strong>and</strong><br />

higher for separating database<br />

<strong>and</strong> log files<br />

Software requirements<br />

Operating system / applications Microsoft Windows 2000 incl.<br />

ServicePack 4<br />

Microsoft Internet Explorer V6.0<br />

incl. ServicePack 1<br />

Microsoft Internet Information<br />

Services (IIS) <strong>and</strong> installed Message<br />

Queuing<br />

Software included in delivery of Microsoft SQL Server 2000 incl.<br />

SIMATIC PCS 7 for which no addi- ServicePack 3<br />

tional license has to be purchased<br />

OS Client SIMATIC PCS 7 V6.0<br />

in connection with StoragePlus<br />

incl. ServicePack 3<br />

SIMATIC BATCH Client Software<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

StoragePlus V1.0<br />

Software for the long-term<br />

archiving of data from the<br />

SIMATIC PCS 7 process control<br />

system<br />

Single license for 1 installation ,<br />

trilingual (German, English,<br />

French)<br />

Type of delivery:<br />

Electronic documentation (German,<br />

English) <strong>and</strong> software on<br />

CD-ROM, certificate of license<br />

<strong>and</strong> authorization diskette<br />

6ES7 652-0XC01-2YA0 C)<br />

C) Subject to export regulations: AL: N, ECCN: EAR99S


■ Overview<br />

The SFC visualization function of the operator system enables<br />

the sequence controls configured with the SFC tool to be displayed<br />

<strong>and</strong> operated in the same way as on the engineering system.<br />

No additional configuration work is necessary. In an overview<br />

display it is possible, for example, to open step <strong>and</strong><br />

transition displays <strong>and</strong> to present step comments or dynamically<br />

supplied stepping conditions.<br />

■ Overview<br />

The SIMATIC Safety Matrix Viewer for SIMATIC PCS 7 serves the<br />

operation <strong>and</strong> monitoring of the SIMATIC Safety Matrix using the<br />

SIMATIC PCS 7 operator system.<br />

Hardware requirements: SIMATIC PCS 7 AS 414H or AS 417H<br />

Software requirements: PCS 7-OS V6.0, SP2 or higher<br />

For further details on the Safety Matrix, please refer to the section<br />

"ES Software – <strong>Engineering</strong> Process Safety" in the chapter<br />

"<strong>Engineering</strong> <strong>System</strong>".<br />

Operator system<br />

OS software<br />

C) Subject to export regulations: AL: N, ECCN: EAR99S<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

SFC visualization<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

SFC Visualization V6.0<br />

6ES7 652-0XD06-2YB0<br />

For displaying <strong>and</strong> operating SFC<br />

sequence controls on an operator<br />

station<br />

Single license for 1 installation,<br />

trilingual (German, English,<br />

French)<br />

Software on PCS 7 Toolset CDs,<br />

electronic documentation on<br />

PCS 7 Documentation CD<br />

Type of delivery: Certificate of<br />

license <strong>and</strong> authorization diskette<br />

SFC Visualization Upgrade from 6ES7 652-0XD06-2YF0<br />

SIMATIC PCS 7 V5.x to V6.0<br />

Single license for 1 installation<br />

trilingual (German, English,<br />

French)<br />

(software on PCS 7 Toolset CDs,<br />

electronic documentation on<br />

PCS 7 Documentation CD)<br />

Type of delivery: Certificate of<br />

license <strong>and</strong> authorization diskette<br />

SIMATIC Safety Matrix Viewer<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

SIMATIC Safety Matrix Viewer<br />

for SIMATIC PCS 7<br />

Operation <strong>and</strong> monitoring of the<br />

Safety Matrix in a SIMATIC PCS 7<br />

environment with several operator<br />

control levels<br />

Bilingual (German, English)<br />

single license for 1 installation,<br />

type of delivery: Certificate of<br />

license <strong>and</strong> authorization diskette;<br />

software <strong>and</strong> electronic<br />

documentation on CD<br />

6ES7 833-1SM60-0YA5 C)<br />

5/13<br />

5


5<br />

Operator system<br />

OS software<br />

Connectivity Pack <strong>and</strong> Client Access Licences<br />

■ Overview<br />

St<strong>and</strong>ardized access of process data in the OS single stations/OS<br />

servers by higher-level information systems, office applications<br />

or user-oriented applications is supported by the<br />

PCS 7 operator system with a range of specifications <strong>and</strong> interfaces.<br />

Because the PCS 7 operator system is OPC-compliant, operator<br />

stations can act as OPC servers <strong>and</strong> be the data source for other<br />

applications. The OS single stations <strong>and</strong> OS servers already<br />

have an integral OPC Data Access Server for access to all online<br />

values that correspond to st<strong>and</strong>ards OPC Data Access 1.1<br />

<strong>and</strong> 2.0. Additional open interfaces are also available as an optional<br />

WinCC/Connectivity Pack for access to archive data <strong>and</strong><br />

indications of the operator system.<br />

5/14<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

■ Function<br />

OPC HDA (Historical Data Access Server)<br />

As OPC HDA server, the PCS 7 operator station makes historical<br />

data from the WinCC archive system available to other applications.<br />

The OPC client, e.g. a reporting tool, can selectively request<br />

the required data by specifying the beginning <strong>and</strong> end of<br />

a time interval. A wide range of diverse unit functions, such as<br />

Variance, Mean Value or Integral, allow preprocessing by the<br />

HDA server, thus reducing the communication load.<br />

OPC A&E (Alarm & Events Server)<br />

As OPC A&E server, the PCS 7 operator station forwards WinCC<br />

indications, including all process-accompanying values, to subscribers<br />

at production <strong>and</strong> company management level, where<br />

they can of course also be acknowledged. Filter mechanisms<br />

<strong>and</strong> subscriptions ensure that only selected <strong>and</strong>/or changed<br />

data is transferred.<br />

OLE DB<br />

OLE DB offers easy to implement, st<strong>and</strong>ardized direct access to<br />

the archive data in the MS SQL server database of the operator<br />

system. It also provides access to all WinCC archive data with<br />

the relevant processaccompanying values, message <strong>and</strong> user<br />

texts.<br />

For further information, see catalog ST 80, section "WinCC/Connectivity<br />

Pack" in the chapter "SIMATIC WinCC options".<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

WinCC/Connectivity Pack<br />

Single license for 1 installation<br />

6AV6 371-1DR06-0AX0 C)<br />

■ Design<br />

WinCC/Client Access License<br />

for (office) computers (without<br />

6AV6 371-1ES06-0AX0 C)<br />

Components of the WinCC/Connectivity Pack that can be used<br />

with SIMATIC PCS 7:<br />

WinCC installation) that access<br />

archive <strong>and</strong> alarm data of an<br />

operator station (OS single sta-<br />

OPC HDA (Historical Data Access Server):<br />

tion/ OS server) using OPC HDA,<br />

Data server for historical data from the WinCC archive system<br />

OPC A&E (Alarm & Events Server):<br />

Data server for indications from the WinCC alarm system<br />

OLE-DB<br />

For direct access to the archive data stored in the MS SQL<br />

server database<br />

OPC A&E or OLE-DB<br />

Single license for 1 installation<br />

WinCC/Client Access License<br />

per processor<br />

for client access to archive <strong>and</strong><br />

alarm data of an operator station<br />

(OS single station/ OS server)<br />

6AV6 371-1ES06-0CX0 C)<br />

A WinCC/Connectivity Pack is required for each operator station<br />

(OS single station/OS server) that makes archive <strong>and</strong> alarm data<br />

available over this interface. With SIMATIC PCS 7, however, it is<br />

using OPC HDA, OPC A&E or<br />

OLE-DB<br />

License for any number of clients<br />

per processor<br />

common to use a mulit-client operating system, with<br />

WinCC/Connectivity Pack as the central OPC server. This collects<br />

the data from the OS servers <strong>and</strong> makes it available to OPC<br />

clients. In this case, only the OPC server requires a WinCC/Connectivity<br />

Pack.<br />

A WinCC/Client Access License is also required for each (office)<br />

computer (without WinCC installation) that accesses the archive<br />

<strong>and</strong> alarm data of an operator station (OS single station/<br />

OS server) using OPC HDA, OPC A&E or OLE-DB.<br />

C) Subject to export regulations: AL: N, ECCN: EAR99S


■ Overview<br />

Redundancy for operator systems<br />

The following information should be observed if a redundant operator<br />

station is to be configured:<br />

The WinCC/Redundancy software is required for redundant<br />

OS single stations for alignment of the archives.<br />

An OS Software Redundant Server Pack is required to configure<br />

a redundant OS server.<br />

BCE communication with the FastEthernet card is generally<br />

sufficient even for redundant operator stations. Up to 8 automation<br />

systems can be connected per pair of servers.<br />

Communication using CP 1613 is only required in cases<br />

where<br />

- a subordinate fault-tolerant automation system is connected,<br />

or<br />

- the maximum number of 8 stations per OS is insufficient.<br />

Operator system<br />

Redundant operator systems<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

OS redundancy<br />

An operator station with CP 1613 is delivered with the S7-1613<br />

software. If a subordinate fault-tolerant automation system is<br />

to be connected, the S7-REDCONNECT software is required.<br />

In this case, the S7-REDCONNECT upgrade package must be<br />

ordered.<br />

If an operator station with BCE communication is to be upgraded<br />

for redundant operation with a subordinate fault-tolerant<br />

automation system, the S7-REDCONNECT software is required<br />

in addition to the CP 1613 communications processor.<br />

If the plant bus is to be designed as a redundant dual ring, two<br />

network cards must be installed per OS (2 x FastEthernet card<br />

or 2 x CP 1613).<br />

5/15<br />

5


5<br />

Operator system<br />

Redundant operator systems<br />

OS redundancy<br />

■ Selection <strong>and</strong> Ordering Data<br />

For the configuration of redundant<br />

OS single stations<br />

Order No.<br />

WinCC/Redundancy<br />

For alignment of archives following<br />

OS restart; single license for<br />

2 installations<br />

Installation required on each of<br />

the two redundant OS single stations<br />

6AV6 371-1CF06-0AX0 C)<br />

RS 232 connecting cable, 10 m 6ES7 902-1AC00-0AA0<br />

For the configuration of redundant<br />

OS servers<br />

OS Software Redundant Server<br />

Pack V6.0<br />

Single license for 2 installations,<br />

with OS software server <strong>and</strong><br />

WinCC/Redundancy as well as<br />

RS 232 connecting cable, 10 m<br />

250 POs/RT 8K 6ES7 652-3XA06-2YA0 D)<br />

2,000 POs/RT 64K 6ES7 652-3XB06-2YA0 D)<br />

3,000 POs/RT 100K 6ES7 652-3XC06-2YA0 D)<br />

5,000 POs/RT 150K 6ES7 652-3XD06-2YA0 D)<br />

8,500 POs/RT 256K<br />

Power Packs for PO expansion,<br />

see OS Software Server (2 Power<br />

Packs each required)<br />

WinCC Options V6 manual<br />

Contents: WinCC/User Archives,<br />

WinCC/Server <strong>and</strong><br />

WinCC/Redundancy<br />

6ES7 652-3XE06-2YA0 D)<br />

English 6AV6 392-1DA06-0AB0<br />

5/16<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

■ Selection <strong>and</strong> Ordering Data<br />

Upgrade package for OS single<br />

stations / OS servers with BCE<br />

for communication with faulttolerant<br />

AS<br />

Order No.<br />

CP 1613<br />

PCI card for connection to Industrial<br />

Ethernet, with AUI/ITP <strong>and</strong><br />

RJ45 connections<br />

6GK1 161-3AA00<br />

S7-REDCONNECT<br />

Software for failsafe S7 communication<br />

through redundant networks,<br />

for CP 1613, can be used<br />

with Windows 2000/XP,<br />

single license for 1 installation,<br />

runtime software, software <strong>and</strong><br />

electronic manual on CD-ROM,<br />

license key on diskette, Class A,<br />

bilingual (German/English)<br />

Upgrade package for OS single<br />

stations / OS servers with CP<br />

1613 for communication with<br />

fault-tolerant AS<br />

6GK1 716-0HB62-3AA0 D)<br />

Upgrade S7-REDCONNECT<br />

Software for expansion of<br />

S7-1613 to S7-REDCONNECT,<br />

can be used with<br />

Windows 2000/XP,<br />

single license for 1 installation,<br />

runtime software, software <strong>and</strong><br />

electronic manual on CD-ROM,<br />

license key on diskette, Class A,<br />

bilingual (German/English)<br />

6GK1 716-0HB62-3AA4 D)<br />

C) Subject to export regulations: AL: N, ECCN: EAR99S<br />

D) Subject to export regulations: AL: N, ECCN: 5D992B1


Batch automation<br />

6/2 SIMATIC BATCH<br />

6/2 Introduction<br />

6/3 SIMATIC BATCH hardware<br />

6/5 SIMATIC BATCH software<br />

6/5 Basic Package<br />

6/6 Batch Control Center<br />

6/6 Recipe <strong>System</strong><br />

6/7 Batch Planning<br />

6/7 Hierarchical Recipe<br />

6/8 ROP Library<br />

6/8 Separation Procedures/Formulas<br />

6/8 SIMATIC BATCH API<br />

6/8 Upgrade<br />

<strong>Siemens</strong> ST PCS 7 · October 2004


6<br />

Batch automation<br />

SIMATIC BATCH<br />

Introduction<br />

■ Design<br />

SIMATIC BATCH is configured either as a single-user system or<br />

as a client/server system, <strong>and</strong> can be used in plants of any size<br />

due to its modular architecture <strong>and</strong> flexible scalability in 4 steps<br />

using 150, 600, 1800 <strong>and</strong> >1800 batch process objects (instances<br />

of plant units <strong>and</strong> equipment modules).<br />

A typical batch automation process is comprised of a batch<br />

server <strong>and</strong> several batch clients, which together process a plant<br />

project. The batch server can be configured with redundancy<br />

(hot st<strong>and</strong>by) in order to increase availability.<br />

2/2<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

■ Integration<br />

SIMATIC BATCH is fully integrated in SIMATIC PCS 7. The plant<br />

data can be configured entirely using the engineering system.<br />

The engineering system passes on all data required for recipe<br />

creation to the batch server, making recipe processing possible<br />

separate from the engineering system. Changes to the configuration<br />

which are made on the engineering system are available<br />

to the batch server using an update function (online/offline).<br />

The hardware of the batch server can be separate from the<br />

OS servers. SIMATIC BATCH clients <strong>and</strong> OS clients can run on<br />

separate or common basic hardware. The PCS 7 operator systems<br />

relevant to the batch are made known to the batch server<br />

during configuration of the batch applications.<br />

SIMATIC BATCH communicates with the automation system<br />

through the PCS 7 operator systems. Operator instructions <strong>and</strong><br />

dialogs can also be integrated into the communication. These<br />

functions can be used to draw attention to necessary operator<br />

inputs, or to offer a facility for data input, e.g. for laboratory values.<br />

SIMATIC BATCH provides special st<strong>and</strong>ard faceplates for<br />

controlling <strong>and</strong> monitoring plant units <strong>and</strong> equipment modules.<br />

SFC instances derived from a SFC-type template are generally<br />

used as the interface to the subordinate automation level. The<br />

properties of the SFC-type, such as modes of operation, setpoints/actual<br />

values, instance parameters, times etc. can be defined<br />

through a properties dialog. However, it is also possible to<br />

use special batch interface blocks for communication with the<br />

processing programs in the automation systems, e.g. for plant<br />

expansions or when connecting non-SIMATIC systems.


■ Design<br />

The modularity <strong>and</strong> flexibility of SIMATIC BATCH are optimally<br />

supported by the hardware available. All the basic hardware<br />

from the chapter "ES/OS/BATCH/IT basic devices" can be used<br />

for SIMATIC BATCH.<br />

For small plants, SIMATIC BATCH can be installed together with<br />

the OS software on a single station system. The hardware for this<br />

OS/BATCH single station can be selected below or in the chapters<br />

"ES/OS/BATCH/IT basic devices" or "Operator system".<br />

Batch process automation typically has a distributed client/server<br />

configuration with one batch server <strong>and</strong> several batch<br />

clients, which together process a plant project. The batch server<br />

of such a configuration can be configured with redundancy (hot<br />

st<strong>and</strong>by) in order to increase availability.<br />

The batch server is only a station in the OS-LAN, <strong>and</strong> therefore<br />

available only in the st<strong>and</strong>ard version with BCE communication.<br />

A FastEthernet RJ45 port is already on board <strong>and</strong> can be used<br />

for connecting to the OS LAN.<br />

Batch automation<br />

SIMATIC BATCH<br />

SIMATIC BATCH hardware<br />

The batch server redundancy is supported by the SIMATIC<br />

BATCH basic package. As with OS redundancy we recommend<br />

you to connect the two redundant servers in addition through the<br />

COM interface using an RS 232 cable (see ordering data for accessories).<br />

Data transmission through this connection has a<br />

positive impact on system performance. No additional hardware<br />

<strong>and</strong> software components from the section "OS server redundancy"<br />

are required.<br />

Multi-VGA graphics card for connecting up to 4 monitors<br />

Display <strong>and</strong> CRT monitors for office <strong>and</strong> industry environments<br />

(see the chapter "ES/OS/BATCH/IT basic devices")<br />

The Multi-VGA graphics cards "2 Screens" <strong>and</strong> "4 Screens" are<br />

offered for multichannel operation of an OS/batch single station<br />

or a batch client with 2 up to 4 process monitors. Plant sections<br />

distributed over 2 or as many as 4 process monitors by means<br />

of a graphics card can be controlled using one keyboard <strong>and</strong><br />

one mouse. The Multi-VGA graphics cards are compliant with<br />

EN 55022 <strong>and</strong> EN 50082 st<strong>and</strong>ards. Each card occupies one<br />

PCI slot in the operator station.<br />

Note:<br />

All signals from SIMATIC BATCH are processed in the operator<br />

system’s signal system, hence there is no need for an additional<br />

signal module.<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

2/3<br />

6


6<br />

Batch automation<br />

SIMATIC BATCH<br />

SIMATIC BATCH hardware<br />

■ Selection <strong>and</strong> Ordering Data<br />

OS/Batch Single Station<br />

SIMATIC PC in rack of 19“ design,<br />

Pentium 4 with 2.8 GHz <strong>and</strong> more,<br />

1 Gbyte RAM (2 x 512 Mbyte),<br />

sound, EIDE-RAID 1 with 2 hard<br />

disks of 120 Gbyte, graphics controller<br />

on board with Dynamic<br />

Video Memory, DVD±RW IDE,<br />

optical mouse,<br />

FastEthernet RJ45 on board for<br />

connection to OS-LAN,<br />

without monitor, keyboard <strong>and</strong><br />

printer,<br />

Windows 2000 Professional MUI<br />

(German, English, French, Italian,<br />

Spanish); SIMATIC PCS 7 preinstalled<br />

<strong>and</strong> on restore DVD<br />

Order No.<br />

PCS 7 ES/OS IL 40 S V2 BCE<br />

Connection to plant bus through<br />

Basic Communication Ethernet<br />

(BCE) with FastEthernet RJ45<br />

network card (PCI card)<br />

6ES7 650-0GC06-0YX0 D)<br />

PCS 7 ES/OS IL 40 S V2 IE<br />

Connection to plant bus through<br />

Industrial Ethernet with CP 1613<br />

communications processor<br />

Batch server<br />

SIMATIC PC in rack of 19“ design,<br />

Pentium 4 with 2.8 GHz <strong>and</strong> more,<br />

1 Gbyte RAM (2 x 512 Mbyte),<br />

sound, EIDE-RAID 1 with 2 hard<br />

disks of 120 Gbyte, graphics controller<br />

on board with Dynamic<br />

Video Memory, DVD-ROM IDE,<br />

optical mouse,<br />

FastEthernet RJ45 on board for<br />

connection to OS-LAN,<br />

without monitor, keyboard <strong>and</strong><br />

printer,<br />

Windows 2000 Server MUI (German,<br />

English, French, Italian,<br />

Spanish); SIMATIC PCS 7 preinstalled<br />

<strong>and</strong> on restore DVD<br />

6ES7 650-0GC16-0YX0 D)<br />

PCS 7 OS Server IL 40 S V2<br />

BCE<br />

Connection to plant bus through<br />

Basic Communication Ethernet<br />

(BCE) with FastEthernet RJ45<br />

network card (PCI card)<br />

Client<br />

6ES7 650-0GE06-0YX0 D)<br />

PCS 7 OS Client IL 40 S V2<br />

SIMATIC PC in rack of 19“ design,<br />

Pentium 4 with 2.8 GHz <strong>and</strong> more,<br />

512 Mbyte RAM (2 x 256 Mbyte),<br />

sound, EIDE hard disk of<br />

80 Gbyte, graphics controller on<br />

board with Dynamic Video Memory,<br />

DVD-ROM IDE, optical<br />

mouse,<br />

FastEthernet RJ45 on board for<br />

connection to OS-LAN,<br />

without monitor, keyboard <strong>and</strong><br />

printer,<br />

Windows 2000 Professional MUI<br />

(German, English, French, Italian,<br />

Spanish); SIMATIC PCS 7 preinstalled<br />

<strong>and</strong> on restore DVD<br />

6ES7 650-0GD06-0YX0 D)<br />

2/4<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

■ Selection <strong>and</strong> Ordering Data<br />

Additional <strong>and</strong> expansion components<br />

Utility software<br />

Order No.<br />

SIMATIC PC/PG Image & Partition<br />

Creator<br />

Software for creating hard disk<br />

images <strong>and</strong> for configurating hard<br />

disk partitions<br />

6ES7 648-6AA02-0YX0 B)<br />

Memory modules for exp<strong>and</strong>ing<br />

the main memory<br />

Memory expansion kit 512<br />

Mbyte (Dual Channel) for<br />

SIMATIC Rack PC IL 40 S V2<br />

(2 x 256 Mbyte DDR SDRAM)<br />

Memory expansion kit 1 Gbyte<br />

(Dual Channel) for SIMATIC<br />

Rack PC IL 40 S V2 (2 x<br />

512 Mbyte DDR SDRAM)<br />

Memory expansion kit 2 Gbyte<br />

(Dual Channel) for SIMATIC<br />

Rack PC IL 40 S V2 (2 x 1 Gbyte<br />

DDR SDRAM)<br />

6ES7 648-2AD30-0FB0 B)<br />

6ES7 648-2AD40-0FB0 B)<br />

6ES7 648-2AD50-0FB0 B)<br />

TK 200 keyboard (PS/2 connection)<br />

German key assignment 6GF6 710-1AA<br />

International key assignment<br />

SIMATIC PC keyboard (USB<br />

connection)<br />

6GF6 710-1BA<br />

International key assignment<br />

3-m power cable for Rack PC<br />

6ES7 648-0CB00-0YA0<br />

1)<br />

For Great Britain 6ES7 900-0BA00-0XA0<br />

For Switzerl<strong>and</strong> 6ES7 900-0CA00-0XA0<br />

For USA 6ES7 900-0DA00-0XA0<br />

For Italy 6ES7 900-0EA00-0XA0<br />

RS 232 connecting cable, 10 m<br />

For connecting the redundant<br />

batch servers through the COM<br />

interface<br />

6ES7 902-1AC00-0AA0<br />

Multi-VGA Graphics Card<br />

"2 Screens“<br />

for operating 2 process monitors<br />

on 1 station<br />

Type of delivery:<br />

Dual graphics card, driver CD,<br />

manual, 1 dual DVI cable for<br />

2 digital outputs, 2 adapters for<br />

VGA outputs<br />

6ES7 652-0XX03-1XE0 B)<br />

Multi-VGA Graphics Card<br />

"4 Screens“<br />

for operating 4 process monitors<br />

on 1 station<br />

Type of delivery:<br />

Quad graphics card, driver CD,<br />

manual, 2 dual DVI cables for<br />

4 digital outputs, 4 adapters for<br />

VGA outputs<br />

6ES7 652-0XX03-1XE1 B)<br />

B) Subject to export regulations: AL: N, ECCN: EAR99H<br />

D) Subject to export regulations: AL: N, ECCN: 5D992B1<br />

1) The PCS 7 systems are delivered as st<strong>and</strong>ard with a "European power<br />

cable". The country-specific versions listed above are required for some<br />

countries.<br />

Monitors, refer to chapter "ES/OS/BATCH/IT basic devices“


Batch automation<br />

SIMATIC BATCH software<br />

SIMATIC BATCH software<br />

■ Overview<br />

■ Overview<br />

The basic software for all SIMATIC BATCH system configurations The basic package includes 150 batch POs (instances of plant<br />

is provided in the basic package consisting of 150 batch POs units <strong>and</strong> equipment modules), one BatchCC (batch control<br />

(instances of plant units <strong>and</strong> equipment modules), a BatchCC center) <strong>and</strong> one Recipe <strong>System</strong> (recipe editor). It enables a<br />

(batch control center) <strong>and</strong> a Recipe <strong>System</strong> (recipe editor). It small SIMATIC BATCH project to be implemented on the hard-<br />

provides everything needed to implement a small SIMATIC ware of a single station or on a client-server combination consist-<br />

BATCH project on the hardware of a single station or on a clienting of a batch client <strong>and</strong> a batch server.<br />

server configuration consisting of a batch client <strong>and</strong> a batch<br />

server.<br />

The capacity of the basic package can be extended by means<br />

of PO options <strong>and</strong> Power Packs to batches with 300, 600, 1,800<br />

The capacity of the basic package can be exp<strong>and</strong>ed by means or unlimited POs.<br />

of PO options <strong>and</strong> Power Packs as described in the section "Basic<br />

package". An appropriate number of BatchCC <strong>and</strong> Recipe ■ Selection <strong>and</strong> Ordering Data Order No.<br />

<strong>System</strong> option packages is needed to exp<strong>and</strong> the client/server<br />

configuration with additional batch clients. Option packages are<br />

available to exp<strong>and</strong> single stations, batch clients <strong>and</strong> batch<br />

servers in their functions as well.<br />

SIMATIC BATCH<br />

Basic Package V6.0<br />

(Batch PO 150)<br />

Option packages for single stations, batch servers <strong>and</strong> batch clients:<br />

Single station<br />

Batch<br />

server<br />

Batch client<br />

ROP Library X X<br />

Hierarchical Recipe X X<br />

Separation Procedures/Formulas<br />

SIMATIC BATCH API<br />

X<br />

X<br />

X<br />

X<br />

Batch Planning X X<br />

Batch Control Center X X<br />

Recipe <strong>System</strong> X X<br />

SIMATIC BATCH works closely with the operator system <strong>and</strong><br />

communicates through the operator system with the automation<br />

systems. For small plants, SIMATIC BATCH is therefore installed<br />

together with the OS software on a single station. The ordering<br />

data for the OS software can be found in the chapter "Operator<br />

system".<br />

Redundant SIMATIC BATCH systems cannot be installed on<br />

OS servers, only on separate BATCH servers.<br />

1)<br />

For single station <strong>and</strong> client-<br />

6ES7 657-0SA06-0YA0 D)<br />

server configuration<br />

Single license for 1 installation, trilingual<br />

(German, English, French)<br />

electronic documentation on<br />

PCS 7 Documentation CD<br />

Type of delivery:<br />

Certificate of license, authorization<br />

diskette, PCS 7 Toolset CDs<br />

<strong>and</strong> additional CDs with Service<br />

Pack 3 for Microsoft Windows<br />

2000 (in 5 languages), Microsoft<br />

Internet Explorer <strong>and</strong><br />

PC Anywhere<br />

SIMATIC BATCH<br />

PO Option V6.0<br />

For expansion of the SIMATIC<br />

BATCH Basic Package<br />

Single license for 1 installation, trilingual<br />

(German, English, French)<br />

Type of delivery:<br />

Certificate of license <strong>and</strong> authorization<br />

diskette<br />

To batch with 300 POs<br />

To batch with 600 POs<br />

6ES7 657-0XE06-2YB0<br />

6ES7 657-0XB06-2YB0<br />

To batch with 1,800 POs 6ES7 657-0XC06-2YB0<br />

To batch with unlimited POs<br />

SIMATIC BATCH<br />

Power Pack V6.0<br />

For expansion of batch POs<br />

Single license for 1 installation, trilingual<br />

(German, English, French)<br />

Type of delivery:<br />

Certificate of license <strong>and</strong> authorization<br />

diskette<br />

6ES7 657-0XD06-2YB0<br />

From batch with 300 POs to<br />

batch with 600 POs<br />

6ES7 657-0XB06-2YD0<br />

From batch with 600 POs to<br />

batch with 1,800 POs<br />

6ES7 657-0XC06-2YD0<br />

From batch with 1,800 POs to<br />

batch with unlimited POs<br />

6ES7 657-0XD06-2YD0<br />

D) Subject to export regulations: AL: N, ECCN: 5D992B1<br />

1) Whereas process objects (PO) represent operable <strong>and</strong> observable blocks<br />

with approx. 30 variables, batch process objects (batch POs) represent<br />

instances of plant units <strong>and</strong> equipment modules.<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

2/5<br />

6


6<br />

Batch automation<br />

SIMATIC BATCH software<br />

Batch Control Center<br />

■ Overview<br />

The Batch Control Center (BatchCC) is the "comm<strong>and</strong> center“<br />

for monitoring <strong>and</strong> controlling batch processes with SIMATIC<br />

BATCH. Using BatchCC it is possible to manage all data relevant<br />

to SIMATIC BATCH through a graphical user interface.<br />

2/6<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

■ Function<br />

BatchCC offers powerful functions for the following tasks:<br />

Reading in <strong>and</strong> updating the plant data of the basic automation<br />

Definition of user privileges for all functions, for clients, or for<br />

plant units of SIMATIC BATCH<br />

Definition of material names <strong>and</strong> codes<br />

Management of master recipes <strong>and</strong> starting the recipe editor<br />

in order to enter the recipe structure<br />

Management of libraries with recipe elements (library operations)<br />

Editing of formula categories <strong>and</strong> management of associated<br />

formulas (parameter sets)<br />

Creation of batches with master recipes<br />

Starting of batch processing <strong>and</strong> controlling of batches<br />

Monitoring <strong>and</strong> diagnostics of batch processing<br />

Recording <strong>and</strong> archiving of recipes <strong>and</strong> batch data<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

SIMATIC BATCH<br />

6ES7 657-0LX06-2YB0<br />

BatchCC V6.0<br />

Single license for 1 installation,<br />

trilingual (German, English,<br />

French)<br />

Software on PCS 7 Toolset CDs,<br />

electronic documentation on<br />

PCS 7 Documentation CD<br />

Type of delivery: Certificate of<br />

license <strong>and</strong> authorization diskette


■ Overview<br />

Note:<br />

The Recipe <strong>System</strong> option package is included once in the basic<br />

package.<br />

Batch automation<br />

SIMATIC BATCH software<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

Recipe <strong>System</strong><br />

■ Function<br />

The recipe editor can be used to:<br />

Create new master recipes <strong>and</strong> library operations<br />

Modify existing master recipes <strong>and</strong> library operations<br />

(changes of structure or parameters)<br />

Document new master recipes <strong>and</strong> library operations<br />

Carry out plausibility tests<br />

Assign releases for testing or production of master recipes<br />

<strong>and</strong> library operations<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

SIMATIC BATCH<br />

6ES7 657-0AX06-2YB0<br />

Recipe <strong>System</strong> V6.0<br />

Single license for 1 installation,<br />

trilingual (German, English,<br />

French)<br />

Software on PCS 7 Toolset CDs,<br />

The Recipe <strong>System</strong> option package presents itself to the user in electronic documentation on<br />

the form of a recipe editor. The recipe editor is a convenient tool PCS 7 Documentation CD<br />

for simple, intuitive creation <strong>and</strong> modification of master recipes<br />

Type of delivery: Certificate of<br />

<strong>and</strong> library operations. It has a graphical user interface, editing license <strong>and</strong> authorization diskette<br />

functions typical of those in Microsoft Windows for single <strong>and</strong><br />

group objects, <strong>and</strong> a structural syntax check function.<br />

The basis for recipe creation are the batch objects created from<br />

the batch plant configuration using the SIMATIC PCS 7 engineering<br />

system, e.g. plant units <strong>and</strong> technological functions. The<br />

batch recipe editor can be started individually, but can also be<br />

called from BatchCC.<br />

2/7<br />

6


6<br />

Batch automation<br />

SIMATIC BATCH software<br />

Batch Planning<br />

■ Overview<br />

The basic package enables the creation of individual production<br />

orders <strong>and</strong> batches. Far more planning functionality is offered by<br />

the additional Batch Planning option package. BatchCC can<br />

then be used to plan batches in advance for a large number of<br />

production orders.<br />

2/8<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

■ Function<br />

The range of functions includes not only the planning but also<br />

the modification, canceling, deleting <strong>and</strong> releasing of batches.<br />

Dividing <strong>and</strong> saving batches for a production can be performed<br />

manually or, after specifying the number of batches <strong>and</strong> the production<br />

quantity, automatically. The following batch parameters<br />

can be selected <strong>and</strong> changed before the release order is given:<br />

Quantity to be prepared<br />

Starting mode (immediately, by operator input or time-controlled)<br />

Plant unit assignment<br />

Formula (parameter set)<br />

Run sequence (interlinking with the previous or next batch)<br />

Indication of batch runtime<br />

Batch planning <strong>and</strong> control are conveniently supported <strong>and</strong> simplified<br />

by special displays such as order category list, production<br />

order list, batch planning list, batch status list <strong>and</strong> batch results<br />

list.<br />

All batches <strong>and</strong> their plant unit assignments can be clearly presented<br />

by a combination of Gantt diagram <strong>and</strong> table. Conflicts<br />

of time or due to multiple assignment of plant units are marked<br />

by symbols. Time conflicts are easily eliminated by moving the<br />

affected batches in the Gantt diagram.<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

SIMATIC BATCH<br />

6ES7 657-0BX06-2YB0<br />

Batch Planning V6.0<br />

Single license for 1 installation,<br />

trilingual (German, English,<br />

French)<br />

Software on PCS 7 Toolset CDs,<br />

electronic documentation on<br />

PCS 7 Documentation CD<br />

Type of delivery: Certificate of<br />

license <strong>and</strong> authorization diskette


■ Overview<br />

Hierarchical recipes according to ISA S88.01<br />

Batch automation<br />

SIMATIC BATCH software<br />

Hierarchical Recipe<br />

SIMATIC BATCH <strong>and</strong> SIMATIC PCS 7 form a functional unit that<br />

fully covers the models described in the ISA S88.01 st<strong>and</strong>ard.<br />

The hierarchical recipe structure is mapped on the plant module<br />

as follows:<br />

Recipe procedure for controlling the process or the production<br />

in a plant<br />

Partial recipe procedure for controlling a process step or a<br />

plant unit<br />

Recipe operation/function for the process engineering<br />

task/function on an equipment module<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

SIMATIC BATCH<br />

6ES7 657-0FX06-2YB0<br />

Hierarchical Recipe V6.0<br />

Single license for 1 installation,<br />

trilingual (German, English,<br />

French)<br />

Software on PCS 7 Toolset CDs,<br />

electronic documentation on<br />

PCS 7 Documentation CD<br />

Type of delivery: Certificate of<br />

license <strong>and</strong> authorization diskette<br />

■ Overview<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

The management of recipe operations is conveniently supported<br />

by a user library (ROP library). Library recipe operations<br />

SIMATIC BATCH<br />

ROP Library V6.0<br />

6ES7 657-0GX06-2YB0<br />

can be inserted as a reference in recipe procedures <strong>and</strong> can Single license for 1 installation<br />

thus be modified from a central location. This reduces the requirements<br />

for engineering <strong>and</strong> validation. If the reference link is<br />

trilingual (German, English,<br />

French)<br />

broken, the recipe operation becomes a fixed component of the Software on PCS 7 Toolset CDs,<br />

recipe procedure, <strong>and</strong> is thus independent of further central<br />

modifications.<br />

electronic documentation on<br />

PCS 7 Documentation CD<br />

Type of delivery: Certificate of<br />

license <strong>and</strong> authorization diskette<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

ROB Library<br />

2/9<br />

6


6<br />

Batch automation<br />

SIMATIC BATCH software<br />

Separation Procedures/Formulas<br />

■ Overview<br />

The flexibility achieved by recipes which are independent of<br />

plant units can be increased even further if the procedure <strong>and</strong><br />

parameter sets (formulas) are separated from one another. Various<br />

master recipes can be created by linking several formulas<br />

using a recipe procedure. This enables central modification of<br />

procedures. The formula structure is determined by the formula<br />

category defined by the user.<br />

SIMATIC BATCH API<br />

■ Overview<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

The SIMATIC BATCH API application programming interface is<br />

an open interface for custom expansions. It provides the user<br />

SIMATIC BATCH<br />

API V6.0<br />

6ES7 657-0MX06-2YB0<br />

with access to SIMATIC BATCH data <strong>and</strong> functions <strong>and</strong> enables Single license for 1 installation,<br />

the programming of special industry or project specific applications.<br />

trilingual (German, English,<br />

French)<br />

Software on PCS 7 Toolset CDs<br />

Type of delivery: Certificate of<br />

license <strong>and</strong> authorization diskette<br />

Upgrade<br />

■ Overview<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

Customers who are already using BATCH flexible V4.02 can up- SIMATIC BATCH Upgrade 6ES7 657-0XX06-0YE0 D)<br />

grade to SIMATIC BATCH V6.0. Recipes created with BATCH From BATCH flexible V4.02 to<br />

flexible V4.02 can be converted for use in SIMATIC BATCH V6.0. SIMATIC BATCH V6.0<br />

The interface blocks of BATCH flexible V4.02 can also be used<br />

in SIMATIC BATCH V6.0.<br />

Single license for 1 installation,<br />

trilingual (German, English,<br />

French)<br />

Electronic documentation on<br />

PCS 7 Documentation CD<br />

Type of delivery:<br />

Certificate of license, authorization<br />

diskette, PCS 7 Toolset CDs<br />

<strong>and</strong> additional CDs with Service<br />

Pack 3 for Microsoft Windows<br />

2000 (in 5 languages), Microsoft<br />

Internet Explorer, Microsoft SQL<br />

Server 2000 <strong>and</strong> PC Anywhere<br />

2/10<br />

Quantity<br />

Temperature<br />

Time<br />

Salt<br />

Pepper<br />

Sugar<br />

Master Recipe 1<br />

Formula 1<br />

1000 kg<br />

90 °C<br />

10 min<br />

Yes<br />

No<br />

100 g<br />

Formula 2<br />

500 kg<br />

80 °C<br />

15 min<br />

Yes<br />

No<br />

150 g<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

Formula 3<br />

900 kg<br />

95 °C<br />

12 min<br />

No<br />

Yes<br />

50 g<br />

Master Recipe 2 Master Recipe 3<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

SIMATIC BATCH<br />

6ES7 657-0HX06-2YB0<br />

Separation Procedures/Formulas<br />

V6.0<br />

Single license for 1 installation,<br />

trilingual (German, English,<br />

French)<br />

Software on PCS 7 Toolset CDs,<br />

electronic documentation on<br />

PCS 7 Documentation CD<br />

Type of delivery: Certificate of<br />

license <strong>and</strong> authorization diskette<br />

D) Subject to export regulations: AL: N, ECCN: 5D992B1


SIMATIC Route Control<br />

7/2 Introduction<br />

7/3 Route Control Hardware<br />

7/5 Route Control Software<br />

<strong>Siemens</strong> ST PCS 7 · October 2004


7<br />

SIMATIC Route Control<br />

Introduction<br />

■ Overview<br />

SIMATIC Route Control adds a tool for the configuration, control,<br />

monitoring <strong>and</strong> diagnostics of material transports in pipeline networks.<br />

It is not specialized on any particular industry.<br />

With SIMATIC Route Control, which can also be combined with<br />

SIMATIC BATCH, users of SIMATIC PCS 7 are capable of automating<br />

not only their production processes <strong>and</strong> associated<br />

warehouses but also the material transports linking both areas.<br />

SIMATIC Route Control can h<strong>and</strong>le complex networks as well as<br />

simple transport routes. In particular SIMATIC Route Control is<br />

predestined for plants with a multitude of complex route combinations<br />

or extensive tank farms such as are found above all in<br />

the chemical, petrochemical <strong>and</strong> food <strong>and</strong> drinks industries.<br />

Preferred applications:<br />

Plants in the medium <strong>and</strong> high capacity range with an extensive<br />

route/pipeline network<br />

Frequent conversions <strong>and</strong> extensions of the transport network<br />

incl.actuators <strong>and</strong> sensors<br />

Transport routes with high flexibility:<br />

- regularly changing materials<br />

- dynamic selection of the source <strong>and</strong> destination of the material<br />

transport (incl. reversing of direction on bidirectional<br />

transport routes)<br />

numerous simultaneous material transports<br />

plant projects in combination with SIMATIC BATCH<br />

7/2<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

■ Integration<br />

SIMATIC Route Control is fully integrated in SIMATIC PCS 7 <strong>and</strong>,<br />

thanks to the modular architecture <strong>and</strong> 3-step scalability (up to<br />

30 / up to 100 / up to 300 simultaneous material transports), can<br />

be flexibly adapted to different sizes of plant.<br />

SIMATIC Route Control provides graded user authorizations for<br />

engineering, operating <strong>and</strong> maintenance personnel. These authorizations<br />

are integrated in the user administration with SI-<br />

MATIC Logon.<br />

The Route Control <strong>Engineering</strong> Tool, the Route Control Library<br />

<strong>and</strong> the Route Control Wizard are concentrated together with the<br />

other engineering tools of the SIMATIC PCS 7 process control<br />

system in a central engineering system. The configuration of<br />

Route Control builds on the basic configuration of the SIMATIC<br />

PCS 7 process control system using blocks from the PCS 7 St<strong>and</strong>ard<br />

Library. Technological elements of relevance for Route<br />

Control (RC elements) are adapted in the CFC Editor using uniform<br />

interface blocks from the Route Control Library. Even existing<br />

SIMATIC PCS 7 plants are therefore easy to exp<strong>and</strong> with<br />

SIMATIC Route Control.<br />

After the transport network is configured <strong>and</strong> the variants of a<br />

material transport tested, the Route Control configuration data<br />

are transferred to the Route Control Server where they can then<br />

be activated at a suitable time. Configuration changes are taken<br />

immediately into account in the determination of a suitable transport<br />

route after transfer from the Route Control <strong>Engineering</strong> Tool<br />

to the Route Control Server <strong>and</strong> subsequent activation through<br />

the Route Control Center (online loading).<br />

The Route Control Server (RC Server) supplies the Route Control<br />

Clients (Route Control Center) with the necessary data <strong>and</strong><br />

transfers their operations to the automation systems. When a<br />

material transport is requested through the Route Control Center<br />

(RCC), it is the job of the RC Server to dynamically compile a<br />

suitable transport route from the partial routes which were configured<br />

using a map of the automation systems on the basis of<br />

the selected parameters (source, destination <strong>and</strong> intermediate<br />

locations) <strong>and</strong> configured parameters (e.g. material or function<br />

IDs).<br />

In the process displays of the SIMATIC PCS 7 operator systems,<br />

each route block is represented by an RC block symbol <strong>and</strong> an<br />

RC faceplate. Through a route block’s RC block symbol it is possible<br />

to select its RC faceplate <strong>and</strong> through a route block’s RC<br />

faceplate it is possible to select its RCC view.


■ Design<br />

The modularity <strong>and</strong> flexibility of SIMATIC Route Control are optimally<br />

supported by the hardware available. All the basic hardware<br />

from the chapter "ES/OS/BATCH/IT basic devices" can be<br />

used for SIMATIC Route Control.<br />

For small plants, SIMATIC Route Control can be installed either<br />

alone or together with the OS software on a single station system.<br />

The hardware for this OS/RC single station can be selected<br />

below or in the chapters "ES/OS/BATCH/IT basic devices" or<br />

"Operator system".<br />

Distributed multiple-station systems with client/server architecture,<br />

exp<strong>and</strong>able with up to 32 clients per server, are typical for<br />

the automation of material transports with SIMATIC Route Control.<br />

Basically it is possible (except in redundant operation) to<br />

operate an RC Server, Batch Server <strong>and</strong> OS Server on shared<br />

basic hardware. However, availability will be higher <strong>and</strong> performance<br />

better if each component has its own server hardware.<br />

The availability of the RC Server can be further increased<br />

through redundant configuration of the server hardware. SI-<br />

MATIC PCS 7 supports multiple-station systems with up to<br />

12 servers/server pairs.<br />

The Route Control Client is represented by the Route Control<br />

Center (RCC). The RCC can be installed on an OS Client, a<br />

Batch Client or separate client hardware.<br />

RC servers <strong>and</strong> OS/RC single stations can be connected to the<br />

Industrial Ethernet plant bus using a communications processor<br />

or a st<strong>and</strong>ard LAN card.<br />

RC Server redundancy is supported by the SIMATIC Route Control<br />

Server program package. Unlike for OS serve redundancy,<br />

no additional hardware <strong>and</strong> software components are required.<br />

SIMATIC Route Control<br />

Route Control Hardware<br />

The basic hardware (PC basic unit) is exp<strong>and</strong>able according to<br />

the customer’s particular requirements <strong>and</strong> whether the hardware<br />

is used as RC Single Station, RC Server or Batch Client with<br />

the following options:<br />

Multi-VGA graphics card for connecting up to 4 monitors<br />

Display <strong>and</strong> CRT monitors for office <strong>and</strong> industry environments<br />

(see the chapter "ES/OS/BATCH/IT basic devices")<br />

The Multi-VGA graphics cards "2 Screens" <strong>and</strong> "4 Screens" are<br />

offered for multichannel operation of an OS/RC Single Station or<br />

a client with 2 up to 4 process monitors. Views distributed over 2<br />

or as many as 4 process monitors by means of a graphics card<br />

can be controlled using one keyboard <strong>and</strong> one mouse. The<br />

Multi-VGA graphics cards are compliant with EN 55022 <strong>and</strong><br />

EN 50082 st<strong>and</strong>ards. Each card occupies one PCI slot in the operator<br />

station.<br />

Note:<br />

All signals from SIMATIC Route Control are processed in the operator<br />

system’s signal system, hence there is no need for an additional<br />

signal module.<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

OS/Route Control Single Station<br />

SIMATIC PC in rack of 19“ design,<br />

Pentium 4 with 2.8 GHz <strong>and</strong> more,<br />

1 Gbyte RAM (2 x 512 Mbyte),<br />

sound, EIDE-RAID 1 with 2 hard<br />

disks of 120 Gbyte, graphics controller<br />

on board with Dynamic<br />

Video Memory, DVD±RW IDE,<br />

optical mouse,<br />

FastEthernet RJ45 on board for<br />

connection to OS-LAN,<br />

without monitor, keyboard <strong>and</strong><br />

printer,<br />

Windows 2000 Professional MUI<br />

(German, English, French, Italian,<br />

Spanish); SIMATIC PCS 7 preinstalled<br />

<strong>and</strong> on restore DVD<br />

PCS 7 ES/OS IL 40 S V2 BCE<br />

Connection to plant bus through<br />

Basic Communication Ethernet<br />

(BCE) with FastEthernet RJ45<br />

network card (PCI card)<br />

PCS 7 ES/OS IL 40 S V2 IE<br />

Connection to plant bus through<br />

Industrial Ethernet with CP 1613<br />

communications processor<br />

6ES7 650-0GC06-0YX0 D)<br />

6ES7 650-0GC16-0YX0 D)<br />

D) Subject to export regulations: AL: N, ECCN: 5D992B1<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

7/3<br />

7


7<br />

SIMATIC Route Control<br />

Route Control Hardware<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

Route Control Server<br />

SIMATIC PC in rack of 19“ design,<br />

Pentium 4 with 2.8 GHz <strong>and</strong> more,<br />

1 Gbyte RAM (2 x 512 Mbyte),<br />

sound, EIDE-RAID 1 with 2 hard<br />

disks of 120 Gbyte, graphics controller<br />

on board with Dynamic<br />

Video Memory, DVD-ROM IDE,<br />

optical mouse,<br />

FastEthernet RJ45 on board for<br />

connection to OS-LAN,<br />

without monitor, keyboard <strong>and</strong><br />

printer,<br />

Windows 2000 Server MUI (German,<br />

English, French, Italian,<br />

Spanish); SIMATIC PCS 7 preinstalled<br />

<strong>and</strong> on restore DVD<br />

PCS 7 OS Server IL 40 S V2<br />

BCE<br />

Connection to plant bus through<br />

Basic Communication Ethernet<br />

(BCE) with FastEthernet RJ45<br />

network card (PCI card)<br />

PCS 7 OS Server IL 40 S V2 IE<br />

Connection to plant bus through<br />

Industrial Ethernet with CP 1613<br />

communications processor<br />

Client<br />

PCS 7 OS Client IL 40 S V2<br />

SIMATIC PC in rack of 19“ design,<br />

Pentium 4 with 2.8 GHz <strong>and</strong> more,<br />

512 Mbyte RAM (2 x 256 Mbyte),<br />

sound, EIDE hard disk of<br />

80 Gbyte, graphics controller on<br />

board with Dynamic Video Memory,<br />

DVD-ROM IDE, optical<br />

mouse,<br />

FastEthernet RJ45 on board for<br />

connection to OS-LAN,<br />

without monitor, keyboard <strong>and</strong><br />

printer,<br />

Windows 2000 Professional MUI<br />

(German, English, French, Italian,<br />

Spanish); SIMATIC PCS 7 preinstalled<br />

<strong>and</strong> on restore DVD<br />

7/4<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

6ES7 650-0GE06-0YX0 D)<br />

6ES7 650-0GE16-0YX0 D)<br />

6ES7 650-0GD06-0YX0 D)<br />

■ Selection <strong>and</strong> Ordering Data<br />

Additional <strong>and</strong> expansion components<br />

Utility software<br />

Order No.<br />

SIMATIC PC/PG Image & Partition<br />

Creator<br />

Software for creating hard disk<br />

images <strong>and</strong> for configurating hard<br />

disk partitions<br />

6ES7 648-6AA02-0YX0 B)<br />

Memory modules for exp<strong>and</strong>ing<br />

the main memory<br />

Memory expansion kit 512<br />

Mbyte (Dual Channel) for<br />

SIMATIC Rack PC IL 40 S V2<br />

(2 x 256 Mbyte DDR SDRAM)<br />

Memory expansion kit 1 Gbyte<br />

(Dual Channel) for SIMATIC<br />

Rack PC IL 40 S V2 (2 x<br />

512 Mbyte DDR SDRAM)<br />

Memory expansion kit 2 Gbyte<br />

(Dual Channel) for SIMATIC<br />

Rack PC IL 40 S V2 (2 x 1 Gbyte<br />

DDR SDRAM)<br />

6ES7 648-2AD30-0FB0 B)<br />

6ES7 648-2AD40-0FB0 B)<br />

6ES7 648-2AD50-0FB0 B)<br />

TK 200 keyboard (PS/2 connection)<br />

German key assignment 6GF6 710-1AA<br />

International key assignment<br />

SIMATIC PC keyboard (USB<br />

connection)<br />

6GF6 710-1BA<br />

International key assignment<br />

3-m power cable for Rack PC<br />

6ES7 648-0CB00-0YA0<br />

1)<br />

For Great Britain 6ES7 900-0BA00-0XA0<br />

For Switzerl<strong>and</strong> 6ES7 900-0CA00-0XA0<br />

For USA 6ES7 900-0DA00-0XA0<br />

For Italy 6ES7 900-0EA00-0XA0<br />

Multi-VGA Graphics Card<br />

"2 Screens“<br />

for operating 2 process monitors<br />

on 1 station<br />

Type of delivery:<br />

Dual graphics card, driver CD,<br />

manual, 1 dual DVI cable for<br />

2 digital outputs, 2 adapters for<br />

VGA outputs<br />

6ES7 652-0XX03-1XE0 B)<br />

Multi-VGA Graphics Card<br />

"4 Screens“<br />

for operating 4 process monitors<br />

on 1 station<br />

Type of delivery:<br />

Quad graphics card, driver CD,<br />

manual, 2 dual DVI cables for<br />

4 digital outputs, 4 adapters for<br />

VGA outputs<br />

6ES7 652-0XX03-1XE1 B)<br />

B) Subject to export regulations: AL: N, ECCN: EAR99H<br />

D) Subject to export regulations: AL: N, ECCN: 5D992B1<br />

1) The PCS 7 systems are delivered as st<strong>and</strong>ard with a "European power<br />

cable". The country-specific versions listed above are required for some<br />

countries.<br />

Monitors, refer to chapter "ES/OS/BATCH/IT basic devices“


■ Overview<br />

Route Control Center<br />

The Route Control Software is structured such that SIMATIC<br />

Route Control can be flexibly adapted to different plant sizes <strong>and</strong><br />

architectures (single/multiple station systems):<br />

Route Control <strong>Engineering</strong> (component of the SIMATIC PCS 7<br />

<strong>Engineering</strong> <strong>System</strong>; see the section "ES Software" in the<br />

chapter "<strong>Engineering</strong> <strong>System</strong>")<br />

Route Control Server<br />

Route Control Center (RCC)<br />

SIMATIC Route Control works closely with the Operator <strong>System</strong>,<br />

hence where small plants are concerned it is possible for the<br />

Route Control Center <strong>and</strong> Route Control Server to be installed<br />

not only on their own but also together with the OS software on a<br />

single station. The ordering data for the OS software can be<br />

found in the chapter "Operator system".<br />

In the case of multiple-station systems it is also possible to operate<br />

the Route Control Server, Batch Server <strong>and</strong> OS Server on<br />

shared basic hardware. However, availability will be higher <strong>and</strong><br />

performance better if they are installed on separate server hardware.<br />

In any case it is impossible to combine a Route Control<br />

Server <strong>and</strong> an OS Server on redundant servers.<br />

The Route Control Server program package suitable for up to<br />

30 simultaneous material transports can be exp<strong>and</strong>ed by means<br />

of add-on Power Packs to meet higher requirements (up to<br />

100 or 300 simultaneous material transports).<br />

The Route Control Client is represented by the Route Control<br />

Center (RCC). The RCC can be installed on an OS Client, a<br />

Batch Client or separate client hardware.<br />

■ Function<br />

SIMATIC Route Control<br />

Route Control Software<br />

Route Control Server<br />

The Route Control Server supplies the RC Clients (RCC) with the<br />

necessary data <strong>and</strong> transfers their operations to the automation<br />

systems. When a material transport is requested through the<br />

RCC, it is the job of the RC Server to dynamically compile a suitable<br />

transport route from the partial routes which were configured<br />

using a map of the automation systems on the basis of the<br />

selected parameters (source, destination <strong>and</strong> intermediate locations)<br />

<strong>and</strong> with due account taken of other parameters (e.g.<br />

function catalogs, function IDs or material IDs) . Configuration<br />

changes can be taken immediately into account in the determination<br />

of a suitable transport route after transfer from the Route<br />

Control <strong>Engineering</strong> Tool to the Route Control Server <strong>and</strong> subsequent<br />

activation through the Route Control Center (online loading).<br />

Route Control Center (RCC)<br />

The RCC can be called either from the faceplate of a route block<br />

or from the start menu. It displays all of a material transport’s relevant<br />

route data <strong>and</strong> error information in several coordinated<br />

views<br />

Key functional features are:<br />

Overview of all RC elements <strong>and</strong> request details<br />

Operation of the selected material transport: Selection of operating<br />

mode: manual/automatic; request, start, stop, continue<br />

<strong>and</strong> end material transport in manual mode; set/change<br />

request parameters (locations: source, destination, intermediate<br />

locations) <strong>and</strong> general properties (function catalog, function<br />

ID, material ID <strong>and</strong> "ignore error") in manual mode; activate/deactivate<br />

sequence functions in manual mode<br />

Diagnostics of material transport request errors caused by<br />

locked RC elements, locked partial routes, inconsistent actuations<br />

or prohibited sequential material<br />

Diagnostics of currently running material transports: color <strong>and</strong><br />

text display of transport route status in the route view of the<br />

RCC; detailed analyses by evaluation of feedback signals<br />

from RC elements<br />

Server functions: Select RC Server, display RC Server status,<br />

update view (read in data again from the RC Server)<br />

Display of the operator who has logged on<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

7/5<br />

7


7<br />

SIMATIC Route Control<br />

Route Control Software<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

SIMATIC Route Control Server<br />

V6.0<br />

for up to 30 simultaneous material<br />

transports 1)<br />

6ES7 658-7FA06-0YB0<br />

For single station <strong>and</strong> clientserver<br />

configuration<br />

Single license for 1 installation, trilingual<br />

(German/English/French)<br />

Software <strong>and</strong> electronic documentation<br />

on CD SIMATIC Route<br />

Control V6.0 (delivered with<br />

SIMATIC Route Control <strong>Engineering</strong><br />

V6.0)<br />

Type of delivery:<br />

Certificate of license <strong>and</strong> authorization<br />

diskette<br />

SIMATIC Route Control Server<br />

Power Pack V6.0<br />

For expansion of the SIMATIC<br />

Route Control Server<br />

Single license for 1 installation, trilingual<br />

(German, English, French)<br />

Software <strong>and</strong> electronic documentation<br />

on CD SIMATIC Route<br />

Control V6.0 (delivered with<br />

SIMATIC Route Control <strong>Engineering</strong><br />

V6.0)<br />

Type of delivery:<br />

Certificate of license <strong>and</strong> authorization<br />

diskette<br />

For up to 100 simultaneous ma- 6ES7 658-7FB06-0YD0<br />

terial transports<br />

For up to 300 simultaneous ma- 6ES7 658-7FC06-0YD0<br />

terial transports<br />

7/6<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

SIMATIC Route Control Center<br />

V6.0<br />

Single license for 1 installation, trilingual<br />

(German, English, French)<br />

Software <strong>and</strong> electronic documentation<br />

on CD SIMATIC Route<br />

Control V6.0 (delivered with<br />

SIMATIC Route Control <strong>Engineering</strong><br />

V6.0)<br />

Type of delivery:<br />

Certificate of license <strong>and</strong> authorization<br />

diskette<br />

6ES7 658-7EX06-0YB0<br />

SIMATIC Route Control <strong>Engineering</strong><br />

V6.0<br />

Single license for 1 installation, trilingual<br />

(German, English, French)<br />

Software <strong>and</strong> electronic documentation<br />

on the CD SIMATIC<br />

Route Control V6.0<br />

Type of delivery:<br />

CD SIMATIC Route Control V6.0,<br />

certificate of license <strong>and</strong> authorization<br />

diskette;<br />

6ES7 658-7DX06-0YA0 D)<br />

D) Subject to export regulations: AL: N, ECCN: 5D992B1<br />

Note :<br />

Detailed information on SIMATIC Route Control <strong>Engineering</strong> V6.0, see "ES<br />

Software" in the chapter "<strong>Engineering</strong> <strong>System</strong>".


IT world<br />

8/2 SIMATIC IT<br />

8/3 @PCS 7<br />

<strong>Siemens</strong> ST PCS 7 · October 2004


8<br />

SIMATIC IT<br />

2/2<br />

IT world<br />

■ Overview<br />

■ Design<br />

SIMATIC IT Production Suite<br />

The SIMATIC IT Production Suite, consisting of the SIMATIC IT<br />

Framework <strong>and</strong> the SIMATIC IT Components, is <strong>Siemens</strong>’ practical<br />

implementation of the requirements of the internationally<br />

recognized MES st<strong>and</strong>ard ISA 95.<br />

7 SIMATIC IT Framework permits modeling of the physical plant<br />

<strong>and</strong> all manufacturing processes in line with the ISA 95 model.<br />

The core component of the SIMATIC IT Framework is the customer’s<br />

plant model which permits direct underst<strong>and</strong>ing of<br />

plant operation.<br />

7 SIMATIC IT Components offer fundamental <strong>and</strong> reliable MES<br />

functionality. Each component is designed for specific parts of<br />

the production process. As a whole, they cover the ISA 95<br />

st<strong>and</strong>ard production functions.<br />

The SIMATIC IT range is rounded off by products which can also<br />

be marketed as st<strong>and</strong>-alone programs independent of the SI-<br />

MATIC IT Production Suite:<br />

SIMATIC IT Historian<br />

Integration <strong>and</strong> synchronization of all business processes Plant Information Management <strong>System</strong> (PIM) for recording,<br />

using SIMATIC IT<br />

saving <strong>and</strong> analyzing process <strong>and</strong> production data<br />

Manufacturing Execution <strong>System</strong>s (MES) permit effective inte- SIMATIC IT Unilab<br />

gration of production processes <strong>and</strong> merch<strong>and</strong>ise management Laboratory Information Management <strong>System</strong> (LIMS)<br />

systems, <strong>and</strong> support the coordination of all resources <strong>and</strong> ap- SIMATIC IT Interspec<br />

plications relevant to manufacturing during all phases of produc- Specifications Management <strong>System</strong> (PLM) for product specition.fications<br />

Using SIMATIC IT – the Manufacturing Execution <strong>System</strong> from SIMATIC IT Framework can integrate components from other<br />

<strong>Siemens</strong> – customers are able to model their complete produc- vendors as well as existing applications such that they can be<br />

tion know-how, exactly define their flow of operations, <strong>and</strong> col- used in the same manner as SIMATIC IT Components.<br />

lect data in real-time from the Enterprise Resource Planning <strong>System</strong><br />

(ERP) <strong>and</strong> from the production department. Manufacturers<br />

can therefore control their plants much more effectively, <strong>and</strong> in- ■ More information<br />

crease their flexibility. As a result of faster <strong>and</strong> more appropriate<br />

You can obtain further information from:<br />

response to all production events, SIMATIC IT helps companies<br />

to reduce downtimes, waste <strong>and</strong> reworking, to optimize ware- Marketing Germany<br />

house stock, <strong>and</strong> to respond more rapidly to customer inquiries. Manfred Graeter<br />

E-mail: manfred.graeter@siemens.com<br />

■ Benefits<br />

European help line : +49 (0) 180 5050 111<br />

<strong>Siemens</strong> <strong>Automation</strong> <strong>and</strong> <strong>Drives</strong><br />

SIMATIC IT from <strong>Siemens</strong> offers decisive advantages. Firstly,<br />

<strong>Automation</strong> Solutions MES<br />

even complex business <strong>and</strong> production structures can be mod-<br />

Viale Cembrano, 11<br />

eled simply, <strong>and</strong> future modifications can also be efficiently inte-<br />

I-16148 Genoa, Italy<br />

grated. Secondly, the model developed for users – i.e. the map-<br />

Tel.: +39 010 3434-1<br />

ping of their business <strong>and</strong> production processes – remains<br />

Fax.: +39 010 383 115<br />

completely transparent, underst<strong>and</strong>able <strong>and</strong>, in particular, inde-<br />

E-mail: marketing.simatic-it@siemens.com<br />

pendent of the system which it controls. Thirdly, the model can<br />

therefore be used uniformly at all sites of a company: processes<br />

can be st<strong>and</strong>ardized throughout the company, <strong>and</strong> best practices<br />

utilized.<br />

Additional information is available in the Internet under:<br />

SIMATIC IT is uniform from modeling up to implementation, for<br />

the model itself executes <strong>and</strong> controls the subsequent MES application.<br />

This shortens the project duration, avoids implementation<br />

errors, provides documentation without gaps, <strong>and</strong> thus effectively<br />

protects the contributed know-how. In this manner,<br />

SIMATIC IT reduces the total cost of ownership of an MES imple-<br />

http://www.siemens.com/simatic-it<br />

mentation, <strong>and</strong> provides additional safeguarding of investments.<br />

Libraries can be used to save the plant <strong>and</strong> production models<br />

defined by SIMATIC IT Framework at any time for simple reuse<br />

in other projects. This significantly reduces introduction <strong>and</strong><br />

maintenance costs as well as the duration of a project.<br />

<strong>Siemens</strong> ST PCS 7 · October 2004


■ Overview<br />

Company-wide availability of process data with @PCS 7<br />

@PCS 7 offers a simple, cost-effective solution for remote access<br />

to the process data that resides in the SIMATIC PCS 7 system.<br />

The data can be displayed <strong>and</strong> processed further on any<br />

computer with any operating system using the st<strong>and</strong>ard software<br />

package @aGlance – even through the intranet/Internet.<br />

@aGlance is integrated in an @PCS 7 server on every operator<br />

station of SIMATIC PCS 7 . To read the data, the target PC requires<br />

only a Web@aGlance package <strong>and</strong> a st<strong>and</strong>ard Web<br />

browser. For writing <strong>and</strong> communication with other @aGlance<br />

servers, the operator station must have a corresponding license.<br />

Upon integration of @aGlance/IT, the SIMATIC PCS 7 can communicate<br />

with a large number of software products for the plant<br />

management/company management level. @PCS 7 provides<br />

customers with access through the @aGlance interface to the<br />

PCS 7 operator system data, including the achieves <strong>and</strong> messages.<br />

An intelligent log-on procedure provides the @aGlance product<br />

range with plug <strong>and</strong> play interfacing while incorporating safety<br />

features. Security <strong>and</strong> access privileges are programmed using<br />

a powerful administration tool.<br />

A further advantage of the open architecture of the client/server<br />

technology is the ability to select the operating systems or applications<br />

on the server or at the client end of the @aGlance/IT software<br />

package. This also means that the implementation of<br />

@aGlance is independent of any existing hardware <strong>and</strong> software<br />

architecture. Hence there is no dependence on specific suppliers<br />

or systems, including those that already exist in the company<br />

<strong>and</strong> may be introduced in the future. The costs of a possible<br />

change of system can be avoided.<br />

■ Benefits<br />

@PCS 7 offers the following benefits:<br />

7 @PCS 7 makes process data available to the operational management<br />

/ company management levels on a client/server basis.<br />

7 @PCS 7 makes process data available throughout the company.<br />

The process data can be visualized, analyzed <strong>and</strong> processed<br />

further from each office desktop.<br />

7 @PCS 7 permits access to all data of the PCS 7 operator stations,<br />

e.g. to archived data.<br />

7 Any client/server application that has an @aGlance interface<br />

can be connected to @PCS 7.<br />

7 @PCS 7 is based on @aGlance technology; @aGlance has established<br />

itself as one of the de facto st<strong>and</strong>ards for interface<br />

software (Middleware) for Internet connections.<br />

7 Users can develop their own custom client/server applications<br />

based on the @aGlance product range.<br />

■ Design<br />

IT world<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

@PCS 7<br />

SIMATIC PCS 7 offers several different versions of @PCS 7:<br />

@PCS 7 Web Read Access<br />

is integrated in the OS software <strong>and</strong> offers reading Internet/Intranet<br />

access to OS data (process data, messages, archived<br />

data)<br />

@PCS 7 Web Write Access option package<br />

provides writing access in addition to reading access to<br />

OS data<br />

@PCS 7 Full Client Access option package<br />

enables communication with @aGlance/IT client applications,<br />

e.g. with the InfoPlus.21 information management system<br />

@PCS 7 Server To Server Communication option package<br />

enables communication with server applications of the<br />

@aGlance/IT server add-ons<br />

Notes:<br />

For @PCS 7 to be run with an OS single station, the software<br />

has to be installed on the computer in question. The clients of<br />

@PCS 7 can communicate with the server in both local <strong>and</strong> remote<br />

modes.<br />

@PCS 7 can be used together with WinCC outside the<br />

SIMATIC PCS 7 environment.<br />

If @PCS 7 is not installed on a SIMATIC PCS 7 operator station,<br />

WinCC is required in addition on the @PCS 7 computer.<br />

2/3<br />

8


8<br />

@PCS 7<br />

2/4<br />

IT world<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

@PCS 7 Web Write Access<br />

Single license for 1 installation, trilingual<br />

(German/English/French)<br />

Electronic documentation on<br />

PCS 7 Documentation CD<br />

Type of delivery: Certificate of<br />

license, authorization diskette,<br />

PCS 7 Toolset CDs <strong>and</strong> additional<br />

CDs with Service Pack 3 for<br />

Microsoft Windows 2000 (in 5 languages),<br />

Microsoft Internet<br />

Explorer <strong>and</strong> PC Anywhere<br />

6ES7 658-0DX06-0YA0 C)<br />

@PCS 7 Full Client Access<br />

Single license for 1 installation, trilingual<br />

(German/English/French)<br />

Electronic documentation on<br />

PCS 7 Documentation CD<br />

Type of delivery: Certificate of<br />

license, authorization diskette,<br />

PCS 7 Toolset CDs <strong>and</strong> additional<br />

CDs with Service Pack 3 for<br />

Microsoft Windows 2000 (in 5 languages),<br />

Microsoft Internet<br />

Explorer <strong>and</strong> PC Anywhere<br />

6ES7 658-0EX06-0YA0 C)<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

@PCS 7 Server to Server Communication<br />

Single license for 1 installation, trilingual<br />

(German/English/French)<br />

Electronic documentation on<br />

PCS 7 Documentation CD<br />

Type of delivery: Certificate of<br />

license, authorization diskette,<br />

PCS 7 Toolset CDs <strong>and</strong> additional<br />

CDs with Service Pack 3 for<br />

Microsoft Windows 2000 (in 5 languages),<br />

Microsoft Internet<br />

Explorer <strong>and</strong> PC Anywhere<br />

6ES7 658-0FX06-0YA0 C)<br />

C) Subject to export regulations: AL: N, ECCN: EAR99S


Communication<br />

9/2 Introduction<br />

9/3 Industrial Ethernet<br />

9/3 Introduction<br />

9/4 Fast Ethernet<br />

9/7 FastConnect<br />

9/8 <strong>System</strong> Connection PCS 7 systems<br />

9/9 PROFIBUS<br />

9/9 Introduction<br />

PROFIBUS DP<br />

9/9 Introduction<br />

9/10 Electrical networks<br />

9/11 Fiber optic cable<br />

9/12 Plastic fiber optic cable<br />

9/13 AS connection<br />

9/14 Y-link<br />

PROFIBUS PA<br />

9/15 Introduction<br />

9/16 Basic components<br />

9/19 AS-Interface<br />

9/18 FastConnect/SpliTConnect<br />

9/19 Other communication<br />

9/20 EIB instabus<br />

9/21 Modbus<br />

<strong>Siemens</strong> ST PCS 7 · October 2004


9<br />

Communication<br />

Introduction<br />

■ Overview<br />

Communication within SIMATIC PCS 7 utilizes the SIMATIC NET<br />

networking components. Based on proven worldwide st<strong>and</strong>ards,<br />

it provides a communication concept that guarantees reliable<br />

data transfer between all levels <strong>and</strong> locations within a<br />

plant.<br />

All SIMATIC NET products have been specially developed for industrial<br />

applications <strong>and</strong> are optimized for all industries <strong>and</strong><br />

plants.<br />

The network components meet high st<strong>and</strong>ards, especially in areas<br />

where the components are subject to external influences,<br />

such as:<br />

interfering electromagnetic fields,<br />

corrosive liquids <strong>and</strong> atmospheres,<br />

explosion hazards <strong>and</strong><br />

high levels of contamination <strong>and</strong>/or mechanical loads.<br />

The SIMATIC NET buses promote consistent, trouble-free communication<br />

between all system components:<br />

engineering <strong>and</strong> operator stations,<br />

automation systems, peripherals <strong>and</strong> field components.<br />

9/2<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

Industrial Ethernet communication is typically used for the system<br />

bus. When integrated in small systems, it allows Ethernet<br />

functionality without a communications processor in the ES/OS.<br />

State-of-the-art Fast Ethernet technology is used with SIMATIC<br />

PCS 7 to meet high data throughput dem<strong>and</strong>s in medium <strong>and</strong><br />

large-sized plants, while providing all the advantages of a high<br />

communication speed of 100 Mbit/s, switching technology, <strong>and</strong><br />

the reliability of redundant optical rings.<br />

PROFIBUS DP/PA, which complies with the international st<strong>and</strong>ard<br />

IEC 61158, is used for the I/O bus <strong>and</strong> for field device connections,<br />

respectively. Both implementations allow the connection<br />

of bus-based field devices in potentially explosive areas.<br />

This enables production sectors to be equipped with absolutely<br />

uniform, consistent communication from all automation levels;<br />

from the field level up to the operations management level.


■ Overview<br />

Industrial Ethernet is used as the bus for the SIMATIC PCS 7 process<br />

control system. Industrial Ethernet is a powerful cell network<br />

based on the IEEE 802.3 st<strong>and</strong>ard.<br />

Note:<br />

Detailed information on Industrial Ethenet <strong>and</strong> the bus components<br />

can be found in the IK PI catalog, in the A&D Mall or in<br />

CA 01 at "Communication/Networks / SIMATIC NET communication<br />

systems".<br />

■ Benefits<br />

With a market share of over 80%, Ethernet is todays leading network<br />

for LAN applications worldwide. Thanks to its characteristics,<br />

Ethernet provides a number of significant benefits for the<br />

user:<br />

Fast commissioning through simple connections<br />

High availability because existing installations can be exp<strong>and</strong>ed<br />

without affecting their operation.<br />

Virtually unlimited communications capacity through scalability<br />

using switching technology<br />

Networking of different application domains, such as office<br />

<strong>and</strong> shopfloor.<br />

Company-wide communication through connection to WAN<br />

(wide area network), e.g. ISDN or Internet.<br />

Investment protection through ongoing compatible development<br />

SIMATIC NET offers major expansions of the Ethernet system for<br />

harsh industrial environments:<br />

Network components for use in these special environmental<br />

conditions<br />

Fast local assembly using the FastConnect cabling system<br />

with RJ45 technology<br />

Failsafe networks through high-speed redundancy<br />

Continuous monitoring of network components using a simple<br />

but effective signal concept<br />

■ Technical specifications<br />

Communication<br />

Industrial Ethernet<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

Introduction<br />

Plant bus / OS-LAN Industrial Ethernet<br />

Number of stations 1,023 per network segment<br />

(IEEE 802.3)<br />

Length of the network<br />

Local network Electrical: up to approx. 1.5 km<br />

Optical: up to approx. 150 km<br />

WAN Worldwide with TCP/IP<br />

Topology Line, tree, ring, star, redundant<br />

ring<br />

9/3<br />

9


9<br />

Communication<br />

Industrial Ethernet<br />

Fast Ethernet<br />

■ Overview<br />

The components used for the SIMATIC PCS 7 bus support modern<br />

Fast Ethernet technology.<br />

The advantages of Fast Ethernet are:<br />

High communication speed of 100 Mbit/s<br />

Switching technology<br />

Redundancy through optical rings<br />

The growing popularity of Fast Ethernet (100 Mbit/s) is owed to<br />

its great similarity with the well-known Ethernet. Data format <strong>and</strong><br />

access procedures are the same. Industrial twisted pair (ITP)<br />

<strong>and</strong> fiberoptic (FO) cables can be used <strong>and</strong> existing technology<br />

expertise can be leveraged. This reduces the costs, the work<br />

load <strong>and</strong> the learning effort associated with Fast Ethernet implementation.<br />

OSM optical switch modules from the SIMATIC NET range are a<br />

simple <strong>and</strong> cost-effective way of connecting existing plants or<br />

plant units with 10 Mbit/s Ethernet (triaxial cables, OLM, star<br />

hubs) to communication networks with 100 Mbit/s Fast Ethernet.<br />

OSM thus enables you to introduce 100 Mbit/s technology one<br />

step at a time.<br />

9/4<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

■ Application<br />

Industrial Ethernet optical switch modules (OSM) enable the<br />

configuration of switched networks with 100Mbit/s in the control<br />

level area where high requirements are imposed on network<br />

availability <strong>and</strong> extensive diagnosis options are needed.<br />

With segmentation (splitting a network into subnetworks/segments)<br />

<strong>and</strong> connecting these segments to an Industrial Ethernet<br />

OSM, load separation <strong>and</strong> an increased performance can be<br />

achieved in existing networks.<br />

The redundancy manager integrated in the OSM allows the assembly<br />

of redundant optical Industrial Ethernet ring structures in<br />

switching technology with fast media redundancy (reconfiguration<br />

time max. 0.3 seconds). The data rate in the ring is<br />

100Mbit/s; up to 50 Industrial Ethernet OSMs per ring can be<br />

used.<br />

In addition to the 2 ring ports, Industrial Ethernet OSMs have<br />

other ports (optionally with RJ45, ITP or BFOC interface) to<br />

which both terminals <strong>and</strong> network segments can be connected.<br />

Selection support for the various product versions of OSM is provided<br />

by the table in the section "Technical data“.<br />

The Optical Media Converters (OMC) convert an electrical<br />

twisted pair interface into an optical interface. It is thus possible<br />

to connect a station with RJ45-TP interface to one of the 8 optical<br />

ports of an OSM BC08.<br />

The Industrial Ethernet Electrical Switch Modules (ESM) enable<br />

the design of electrical rings. The data rate in the ring is likewise<br />

100Mbit/s; up to 50ESMs per ring can be used. In addition to the<br />

2 ring ports, the ESMs have other ports to which both terminals<br />

<strong>and</strong> network segments can be connected.<br />

Optical <strong>and</strong> electrical transmission media<br />

FIBER OPTIC CABLE) is preferably used as optical transmission<br />

medium. The st<strong>and</strong>ard cables are suitable for overground installation<br />

in the outdoor <strong>and</strong> indoor area. They are available in fixed<br />

lengths, preassembled with 4 BFOC connectors.<br />

The data packages arriving from a bus station are only relayed<br />

to the port to which the receiver is connected. The redundant,<br />

optical ring topology enhances the reliability of a network; communication<br />

is maintained even if a fiberoptic cable breaks.<br />

The terminals are connected through industrial twisted pairs<br />

(ITPs). The preassembled ITP st<strong>and</strong>ard cable with Sub-D connectors<br />

is available for connection between stations <strong>and</strong> network<br />

components. Line lengths of up to 100 m can be achieved while<br />

saving on patch technology.<br />

The ITP st<strong>and</strong>ard cable 9/15 is equipped with a 9-pin <strong>and</strong> a<br />

15-pin connector. The cable is used for direct connection of terminals<br />

with ITP interface to Industrial Ethernet components with<br />

ITP interface.<br />

The ITP XP st<strong>and</strong>ard cable 9/9 is equipped with two 9-pin connectors.<br />

This cable is crossed for direct connection of two Industrial<br />

Ethernet network components with ITP interface.<br />

The ITP XP st<strong>and</strong>ard cable 15/15 is equipped with two 15-pin<br />

connectors. This cable is crossed for direct connection of two<br />

terminals with ITP interface.<br />

The Industrial Ethernet ITP connectors have Sub-D connectors<br />

made of metal <strong>and</strong> are available in two versions:<br />

9-pin connector with straight outgoing cable, for connection to<br />

OSM/ESM, OLM or ELM<br />

15-pin connector with variable outgoing cable, for connection<br />

to terminals with ITP interface<br />

Alternatively, the terminals can also be connected to twisted pair<br />

(TP cord) cables. Detailed information on TP cord cables can be<br />

found in the IK PI catalog, in the A&D Mall or in CA 01 at "Communication/Networks<br />

/ SIMATIC NET communication systems".


■ Technical specifications<br />

Selection support for product versions of OSM <strong>and</strong> ESM<br />

Type <strong>and</strong> number Preferentially for use<br />

of ports<br />

Sub-D (ITP)<br />

RJ45 (TP)<br />

Multimode DO<br />

1) TP cable inside a switchgear cabinet<br />

2) For cross-building connection of Fast Ethernet networks with OSM<br />

3) For design of an optical network, where TP cable (max. 6 m) are only<br />

used inside switchgear cabinets<br />

4) Connects a station with RJ45-TP interface to one of the 8 optical ports of<br />

an OSM BC08<br />

5) Inside buildings<br />

6) Inside switchrooms<br />

Singlemode FO<br />

with<br />

high<br />

EMC<br />

loading<br />

for<br />

plant<br />

bus<br />

for<br />

OS-<br />

LAN<br />

OSM TP22 –- 2 2 –- 1)<br />

OSM ITP62 (st<strong>and</strong>ard) 6 –- 2 –-<br />

OSM TP62 –- 6 2 –-<br />

OSM ITP62-LD 6 –- –- 2<br />

OSM ITP53 5 –- 3 –- 2) 2)<br />

OSM BC08 –- –- 8 –- 3) 3) 3)<br />

OMC TP11 –- 1 1 –- 4) 4) 4)<br />

ESM ITP80 8 –- –- –- 5)<br />

ESM TP40 –- 4 –- –- 6)<br />

ESM TP80 –- 8 –- –- 6)<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

OSM TP22 for<br />

6GK1 105-2AE00<br />

Industrial Ethernet<br />

Optical switch module with<br />

2 fiberoptic ports 100 Mbit/s,<br />

2 RJ45 ports 10/100 Mbit/s <strong>and</strong><br />

4 digital inputs; redundant<br />

DC 24 V supply <strong>and</strong> signal contact;<br />

with network management<br />

OSM ITP62 for<br />

6GK1 105-2AA10<br />

Industrial Ethernet<br />

Optical switch module with<br />

2 fiberoptic ports 100 Mbit/s,<br />

6 ITP ports 10/100 Mbit/s <strong>and</strong><br />

8 digital inputs; redundant<br />

DC 24 V supply <strong>and</strong> signal contact;<br />

with network management<br />

OSM TP62 for<br />

6GK1 105-2AB10<br />

Industrial Ethernet<br />

Optical switch module with<br />

2 fiberoptic ports 100 Mbit/s,<br />

6 RJ45 ports 10/100 Mbit/s <strong>and</strong><br />

8 digital inputs; redundant<br />

DC 24 V supply <strong>and</strong> signal contact;<br />

with network management<br />

OSM ITP62-LD for<br />

6GK1 105-2AC10<br />

Industrial Ethernet<br />

Optical switch module with<br />

2 fiberoptic ports 100 Mbit/s long<br />

distance (single-mode fiberoptic<br />

cable up to 26 km), 6 ITP ports<br />

10/100 Mbit/s <strong>and</strong> 8 digital inputs;<br />

redundant DC 24 V supply <strong>and</strong><br />

signal contact; with network management<br />

Communication<br />

Industrial Ethernet<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

OSM ITP53 for<br />

6GK1 105-2AD10<br />

Industrial Ethernet<br />

Optical switch module with<br />

3 fiberoptic ports 100 Mbit/s,<br />

5 ITP ports 10/100 Mbit/s <strong>and</strong><br />

8 digital inputs; redundant<br />

DC 24 V supply <strong>and</strong> signal contact;<br />

with network management,<br />

for cross-building connection of<br />

two Fast Ethernet networks with<br />

OSM<br />

Industrial Ethernet ESM TP40 6GK1 105-3AC00<br />

Electrical switch module with<br />

4 RJ45 ports 10/100 Mbit/s <strong>and</strong><br />

4 digital inputs; redundant<br />

DC 24 V supply <strong>and</strong> signal contact;<br />

with network management,<br />

preferably for OS-LAN<br />

Industrial Ethernet ESM ITP80 6GK1 105-3AA10<br />

Electrical switch module with<br />

8 ITP ports 10/100 Mbit/s <strong>and</strong><br />

8 digital inputs; redundant<br />

DC 24 V supply <strong>and</strong> signal contact;<br />

with network management,<br />

preferably for OS-LAN<br />

Industrial Ethernet ESM TP80 6GK1 105-3AB10<br />

Electrical switch module with<br />

8 RJ45 ports 10/100 Mbit/s <strong>and</strong><br />

8 digital inputs; redundant<br />

DC 24 V supply <strong>and</strong> signal contact;<br />

with network management,<br />

preferably for OS-LAN<br />

OSM BC08 for<br />

6GK1 105-4AA00<br />

Industrial Ethernet<br />

Optical switch module with<br />

8 fiberoptic ports 100 Mbit/s <strong>and</strong><br />

8 digital inputs; redundant<br />

DC 24 V supply <strong>and</strong> signal contact;<br />

with network management<br />

Industrial Ethernet OMC TP11 6GK1 100-2AB00<br />

Optical media converter RJ45 on<br />

multimode fiberoptic cable<br />

(BFOC) with 100 Mbit/s up to<br />

3km;<br />

redundant DC 24 V supply <strong>and</strong><br />

signal contact<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

Fast Ethernet<br />

9/5<br />

9


9<br />

Communication<br />

Industrial Ethernet<br />

Fast Ethernet<br />

■ Selection <strong>and</strong> Ordering Data<br />

Optical transmission media<br />

FIBER OPTIC CABLE<br />

st<strong>and</strong>ard cable, splittable<br />

Preassembled with 4 BFOC connectors<br />

Preferred lengths<br />

Order No.<br />

1 m 6XV1 820-5BH10 B)<br />

5 m 6XV1 820-5BH50 B)<br />

10 m 6XV1 820-5BN10 B)<br />

20 m 6XV1 820-5BN20 B)<br />

50 m 6XV1 820-5BN50 B)<br />

BFOC Connector Set<br />

For FIBER OPTIC CABLE,<br />

20 st<strong>and</strong>ard cables<br />

Electrical transmission media<br />

ITP St<strong>and</strong>ard Cable for Industrial<br />

Ethernet<br />

Not preassembled, sold by the<br />

meter<br />

6GK1 901-0DA20-0AA0 B)<br />

2 x 2-core, without connectors<br />

For connection of a terminal; for<br />

self-assembly of connectors or for<br />

the connection between patch<br />

panel <strong>and</strong> socket<br />

ITP St<strong>and</strong>ard Cable 9/15<br />

ITP installation cable for direct<br />

connection of terminals with ITP<br />

interface to Industrial Ethernet<br />

network components<br />

with ITP interface; with a 9-pin<br />

<strong>and</strong> a 15-pin Sub-D plug<br />

6XV1 850-0AH10<br />

2 m 6XV1 850-0BH20<br />

5 m 6XV1 850-0BH50<br />

8 m 6XV1 850-0BH80<br />

12 m 6XV1 850-0BN12<br />

15 m 6XV1 850-0BN15<br />

20 m 6XV1 850-0BN20<br />

30 m 6XV1 850-0BN30<br />

40 m 6XV1 850-0BN40<br />

50 m 6XV1 850-0BN50<br />

60 m 6XV1 850-0BN60<br />

70 m 6XV1 850-0BN70<br />

80 m 6XV1 850-0BN80<br />

90 m 6XV1 850-0BN88<br />

100 m 6XV1 850-0BT10<br />

9/6<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

ITP XP St<strong>and</strong>ard Cable 9/9<br />

Crossed ITP installation cable for<br />

direct connection of two Industrial<br />

Ethernet network components<br />

with ITP interface;<br />

with two 9-pin Sub-D plugs<br />

2 m 6XV1 850-0CH20<br />

5 m 6XV1 850-0CH50<br />

8 m 6XV1 850-0CH80<br />

12 m 6XV1 850-0CN12<br />

15 m 6XV1 850-0CN15<br />

20 m 6XV1 850-0CN20<br />

30 m 6XV1 850-0CN30<br />

40 m 6XV1 850-0CN40<br />

ITP XP st<strong>and</strong>ard cable 15/15<br />

Crossed ITP installation cable for<br />

direct connection of two terminals<br />

with ITP interface;<br />

with two 15-pin sub-D plugs<br />

2 m 6XV1 850-0DH20<br />

6 m 6XV1 850-0DH60<br />

10 m 6XV1 850-0DN10<br />

ITP Connector for Industrial<br />

Ethernet<br />

9-pin, for connection to<br />

6GK1 901-0CA00-0AA0<br />

OSM/ESM, OLM or ELM<br />

15-pin, for connection to termi- 6GK1 901-0CA01-0AA0<br />

nals with ITP interface<br />

B) Subject to export regulations: AL: N, ECCN: EAR99H<br />

For other lengths of the FIBER OPTIC CABLE <strong>and</strong> other fiberoptic cables,<br />

see the IK PI catalog.<br />

Note:<br />

Supplementary components for the SIMATIC NET cable range can be ordered<br />

from your local contact person. For technical support, please contact:<br />

J. Hertlein, A&D SE V22<br />

Tel.: +49 (911) 750 44 65<br />

Fax: +49 (911)750 99 91<br />

E-mail: juergen.hertlein@siemens.com


■ Overview<br />

IE FC RJ45 plug with 90° outgoing cable (left) <strong>and</strong> with 180° outgoing<br />

cable (right)<br />

Industrial Ethernet FastConnect is a system for fast, easy assembly<br />

of Industrial Ethernet FC cables. The FastConnect stripping<br />

method enables fast <strong>and</strong> easy connection of the Industrial<br />

Ethernet FC cable to the RJ45 connection elements. Terminals<br />

<strong>and</strong>/or network components are connected through TP cord cables.<br />

Using the FC Stripping Tool it is possible to remove the outer<br />

casing <strong>and</strong> the woven shield accurately in a single step. The<br />

prepared cable is connected using the Industrial Ethernet<br />

FastConnect RJ45 Plugs.<br />

The FastConnect RJ45 Plugs enable fast <strong>and</strong> easy fitting of the<br />

FastConnect installation cables in the field. The Industrial Ethernet<br />

FastConnect Stripping Tool for preparing the cable end<br />

(stripping of cable sheath <strong>and</strong> shield in one operation) enables<br />

easy h<strong>and</strong>ling <strong>and</strong> fast error-free contacting of the cable on the<br />

plug-in connector. The plug-in connector has no parts that can<br />

get lost; fitting is thus possible even in difficult conditions.<br />

Another way to switch over RJ45 to the insulation displacement<br />

system is to use the FastConnect Outlet RJ45.<br />

Detailed information on TP cord cables <strong>and</strong> the FastConnect<br />

Outlet RJ45 can be found in the IK PI catalog, in the A&D Mall or<br />

in CA 01 at "Communication/Networks / SIMATIC NET communication<br />

systems".<br />

You will find other specifications of the network topology in the<br />

manual for TP <strong>and</strong> fiberoptic networks.<br />

Communication<br />

Industrial Ethernet<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

FastConnect<br />

■ Design<br />

Industrial Ethernet FastConnect RJ45 Plugs are available in two<br />

versions:<br />

with 180° (straight) outgoing cable,<br />

with 90° (offset) outgoing cable.<br />

They enable optimum connection of an Industrial Ethernet Fast-<br />

Connect cable to terminals <strong>and</strong> network components. The plugs<br />

have a robust, industry-compatible metal casing that protects<br />

the data communication effectively from interference. Contacting<br />

of the FC cable versions is simple <strong>and</strong> reliable with the 4 integrated<br />

insulation displacement contacts. The stripped end of<br />

the cable is inserted in the raised insulation displacement terminal<br />

<strong>and</strong> the terminal pressed down to make reliable contact with<br />

the conductor.<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

Industrial Ethernet<br />

6XV1 840-2AH10<br />

FC St<strong>and</strong>ard Cable<br />

TP installation cable for connection<br />

to Industrial Ethernet<br />

FC Outlet RJ45 for universal use,<br />

4-core, shielded,<br />

sold by the meter<br />

Max. delivery unit<br />

1000 m,<br />

minimum order 20 m<br />

Preferred length 1,000 m 6XV1 840-2AU10<br />

Industrial Ethernet<br />

6GK1 901-1GA00<br />

FC Stripping Tool<br />

Preset stripping tool for rapid<br />

stripping of insulation from Industrial<br />

Ethernet FC cables<br />

Industrial Ethernet<br />

6GK1 901-1GB00<br />

FC Blade Cassettes<br />

Spare blade cassettes for the<br />

FC stripping tool, 5 cassettes<br />

IE FC RJ45 Plug 180<br />

RJ45 plug-in connector for Industrial<br />

Ethernet with robust metal<br />

housing <strong>and</strong> integrated insulation<br />

displacement contacts for connecting<br />

Industrial Ethernet FC<br />

installation cables; with 180° outgoing<br />

cable; for network components<br />

<strong>and</strong> CPs/CPUs with<br />

Industrial Ethernet interface<br />

1 pack = 1 unit 6GK1 901-1BB10-2AA0<br />

1 pack = 10 units 6GK1 901-1BB10-2AB0<br />

1 pack = 50 units 6GK1 901-1BB10-2AE0<br />

IE FC RJ45 Plug 90<br />

RJ45 plug-in connector for Industrial<br />

Ethernet with robust metal<br />

housing <strong>and</strong> integrated insulation<br />

displacement contacts for connecting<br />

Industrial Ethernet FC<br />

installation cables; with 90° outgoing<br />

cable<br />

1 pack = 1 units 6GK1 901-1BB20-2AA0<br />

1 pack = 10 units 6GK1 901-1BB20-2AB0<br />

1 pack = 50 units 6GK1 901-1BB20-2AE0<br />

Industrial Ethernet<br />

See the IK PI catalog<br />

FC Outlet RJ45<br />

Documentation<br />

Manual<br />

for TP <strong>and</strong> fiberoptic networks<br />

Network architecture, components,<br />

configurations, installation<br />

German 6GK1 970-1BA10-0AA0<br />

English 6GK1 970-1BA10-0AA1<br />

9/7<br />

9


9<br />

Communication<br />

Industrial Ethernet<br />

<strong>System</strong> Connection PCS 7 systems<br />

■ Overview<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

The CP 443-1 communications module is used for connecting <strong>System</strong> Connection AS<br />

SIMATIC PCS 7 automation systems to Industrial Ethernet. CP 443-1<br />

6GK7 443-1EX11-0XE0<br />

The following selection criteria apply for connecting operator<br />

systems (single stations / server) <strong>and</strong> engineering systems to<br />

Industrial Ethernet:<br />

Communications module for connection<br />

of SIMATIC S7-400 to<br />

Industrial Ethernet through<br />

TCP/IP, ISO <strong>and</strong> UDP; for S7 com-<br />

The supplied FastEthernet card is sufficient for basic communications<br />

(connection of up to 8 lower-level automation systems).<br />

An alternative is to use a CP 1612 communications<br />

module incl. SOFTNET S7 software for Industrial Ethernet.<br />

munication, S5-compatible communication<br />

(SEND/RECEIVE) with<br />

FETCH/ WRITE with or without<br />

RFC 1006, diagnostics expansion,<br />

Multicast, commissioning<br />

If a maximum of 8 automation systems per operator system is<br />

not enough or a fault-tolerant automation system needs to be<br />

through LAN 10/100 Mbit/s, with<br />

electronic manual on CD-ROM<br />

connected you will need a CP 1613 communications module<br />

(see picture).<br />

S7-1613 software is required to operate the CP 1613.<br />

S7 REDCONNECT software is required instead to operate a<br />

<strong>System</strong> Connection OS/ES<br />

CP 1612<br />

PCI card for connection to Industrial<br />

Ethernet (10/100 Mbit/s), with<br />

6GK1 161-2AA00 B)<br />

fault-tolerant automation system. <strong>System</strong>s with S7-1613 soft- RJ45 connection<br />

ware, e.g. preassembled operator systems, can be upgraded<br />

to this software with an S7 REDCONNECT upgrade.<br />

SOFTNET S7 for<br />

Industrial Ethernet<br />

Software for S7 <strong>and</strong> S5-compatible<br />

communication, for CP 1612,<br />

can be used with Windows<br />

2000/XP,<br />

single license for 1 installation,<br />

runtime software, software <strong>and</strong><br />

electronic manual on CD-ROM,<br />

license key on diskette, Class A,<br />

bilingual (German/English)<br />

6GK1 704-1CW62-3AA0 D)<br />

CP 1613<br />

PCI card for connection to Industrial<br />

Ethernet (10/100 Mbit/s), with<br />

AUI/ITP <strong>and</strong> RJ45 connections<br />

6GK1 161-3AA00<br />

S7-1613 for Industrial Ethernet<br />

S7 communication software for<br />

CP 1613,<br />

can be used with Windows<br />

2000/XP,<br />

single license for 1 installation,<br />

runtime software, software <strong>and</strong><br />

electronic manual on CD-ROM,<br />

license key on diskette, Class A,<br />

bilingual (German/English)<br />

6GK1 716-1CB62-3AA0 D)<br />

S7-REDCONNECT<br />

Software for failsafe S7 communication<br />

through redundant networks,<br />

for CP 1613, can be used<br />

with Windows 2000/XP,<br />

single license for 1 installation,<br />

runtime software, software <strong>and</strong><br />

electronic manual on CD-ROM,<br />

license key on diskette, Class A,<br />

bilingual (German/English)<br />

6GK1 716-0HB62-3AA0 D)<br />

Upgrade S7-REDCONNECT<br />

Software for expansion of<br />

S7-1613 to S7-REDCONNECT,<br />

can be used with<br />

Windows 2000/XP,<br />

single license for 1 installation,<br />

runtime software, software <strong>and</strong><br />

electronic manual on CD-ROM,<br />

license key on diskette, Class A,<br />

bilingual (German/English)<br />

6GK1 716-0HB62-3AA4 D)<br />

9/8<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

B) Subject to export regulations: AL: N, ECCN: EAR99H<br />

D) Subject to export regulations: AL: N, ECCN: 5D992B1


■ Overview<br />

Communication at field level with PROFIBUS<br />

Distributed peripherals such as I/O modules, measurement<br />

transducers, drives, valves or operator terminals communicate<br />

with the automation systems at field level through a powerful<br />

real-time bus system. This communication is characterized by<br />

the cyclic transmission of process data <strong>and</strong> the acyclic transmission<br />

of alarms, parameters <strong>and</strong> diagnostic data.<br />

PROFIBUS is predestined for these tasks because it enables<br />

high-speed communication with the distributed I/Os by means of<br />

a communications protocol (PROFIBUS DP), <strong>and</strong> permits direct<br />

connection of bus-capable intelligent field devices, including<br />

power supply in accordance with IEC 61158 (PROFIBUS PA).<br />

PROFIBUS is simple, rugged <strong>and</strong> reliable, <strong>and</strong> supports online<br />

parameterization of the distributed components, communication<br />

with HART field devices, redundancy <strong>and</strong> failsafe structures. It<br />

enables online expansions with new distributed components<br />

<strong>and</strong> can be used in st<strong>and</strong>ard environments or in hazardous areas.<br />

On account of these characteristics, PROFIBUS is now established<br />

in all sectors of the production, process <strong>and</strong> hybrid industries<br />

<strong>and</strong> has become the most successful open field bus in<br />

the world. This is confirmed by the more than 10 million<br />

PROFIBUS DP nodes <strong>and</strong> the more than 320,000 PROFIBUS PA<br />

nodes installed to date.<br />

■ Benefits<br />

SIMATIC PCS 7 utilizes the benefits of the PROFIBUS from start<br />

to finish:<br />

Optimal distributed system structure: Small space requirement,<br />

less cabling effort<br />

Effective engineering through st<strong>and</strong>ardization of the process<br />

signals, diagnostics <strong>and</strong> profiles<br />

Shorter commissioning times through short loop checks, easy<br />

parameterization <strong>and</strong> the elimination of calibration work<br />

Optimal life cycle management through best possible diagnostics<br />

<strong>and</strong> preventive maintenance<br />

■ Application<br />

Communication<br />

PROFIBUS<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

Introduction<br />

The PROFIBUS DP field bus enables the SIMATIC PCS 7 automation<br />

systems to communicate with distributed I/Os from the<br />

ET 200 range (remote I/Os) as well as with field/process devices,<br />

CPUs/CPs <strong>and</strong> operator terminals that have a PROFIBUS DP interface.<br />

The intrinsically safe version (PROFIBUS DP/iS) can be<br />

taken into Ex zone 1 when used with an additional field bus isolating<br />

transformer. Connection of the intelligent, distributed<br />

field/process devices <strong>and</strong> operator terminals on PROFIBUS PA<br />

to the automation system takes place likewise through<br />

PROFIBUS DP.<br />

Depending on the type of automation system <strong>and</strong> the number of<br />

available slots, up to 4 PROFIBUS DP lines can be connected to<br />

a SIMATIC PCS 7 automation system through internal interfaces<br />

in the CPU, <strong>and</strong> up to 10 PROFIBUS DP lines through additional<br />

CP 443-5 Extended communication modules. On a<br />

PROFIBUS DP line it is possible to operate up to 125 devices<br />

<strong>and</strong> on a bus segment up to 31 devices with PROFIBUS DP interface<br />

(32 stations).<br />

Electrical <strong>and</strong> optical transmission technologies offer many different<br />

configuration options for PROFIBUS DP networks. Electrical<br />

networks can span up to approx. 10 km. Network lengths of<br />

up to approx. 100 km are possible in combination with optical<br />

transmission technologies. With SIMATIC PCS 7, PROFIBUS DP<br />

topologies are always configured through the st<strong>and</strong>ard electrical<br />

PROFIBUS DP connection on the automation system in the form<br />

of electrical or mixed (electrical/optical) networks. In the case of<br />

mixed networks, the transition between the two media is implemented<br />

by OLM. As regards communication between the stations,<br />

there is no difference between electrical two-wire technology<br />

<strong>and</strong> fiber optic technology.<br />

Following topologies are configurable: Line, tree, ring, star, redundant<br />

9/9<br />

9


9<br />

Communication<br />

PROFIBUS DP<br />

Electrical networks<br />

■ Overview<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

Shielded twisted-pair cables are used as the transmission medium<br />

for electric PROFIBUS DP networks. The PROFIBUS DP<br />

PROFIBUS FastConnect St<strong>and</strong>ard<br />

Cable<br />

6XV1 830-0EH10<br />

stations are connected to these bus lines through a bus connec- St<strong>and</strong>ard type with special design<br />

tor (max. 32 stations per segment).<br />

Individual bus segments can be interconnected through repeaters.<br />

for fast mounting, 2-core,<br />

shielded, sold by the meter<br />

Specify length in m<br />

Max. delivery unit 1,000 m, mini-<br />

If required, a diagnostics repeater can be used for detailed dimum<br />

order quantity 20 m<br />

agnostics of PROFIBUS DP segments. It performs physical on- Preferred lengths<br />

line monitoring of the copper bus cables. In the event of a fault it<br />

sends a diagnostics message to the DP master containing detailed<br />

data on the fault type <strong>and</strong> fault location.<br />

-20 m<br />

-50 m<br />

6XV1 830-0EN20<br />

6XV1 830-0EN50<br />

Bus segments are terminated by the active RS 485 terminating<br />

-100 m 6XV1 830-0ET10<br />

element.<br />

-200 m 6XV1 830-0ET20<br />

RS485-iS<br />

-500 m 6XV1 830-0ET50<br />

The RS485-iS coupler is a field bus isolating transformer that en-<br />

Other PROFIBUS cables See the IK PI catalog<br />

ables PROFIBUS to be run intrinsically safely in hazardous ar- PROFIBUS FastConnect Strip- 6GK1 905-6AA00<br />

eas. The 6ES7972-0DA30-0XA0 plug with special (passive) terping Tool<br />

minating resistor is required to terminate the RS 485-iS.<br />

Preset stripping tool for rapid<br />

FastConnect<br />

stripping of PROFIBUS FastConnect<br />

bus cables<br />

PROFIBUS FastConnect is a system for fast <strong>and</strong> easy assembly<br />

of PROFIBUS copper cables. The system comprises compatible<br />

PROFIBUS FastConnect<br />

Blade Cassettes<br />

6GK1 905-6AB00<br />

components<br />

Spare blade cassettes for the<br />

FastConnect st<strong>and</strong>ard cable for fast assembly<br />

FastConnect stripping tool<br />

with FastConnect blade cassettes<br />

FastConnect PROFIBUS bus connector<br />

PROFIBUS FastConnect stripping<br />

tool<br />

PROFIBUS FastConnect Bus<br />

Connector RS 485 with 90°<br />

cable outlet<br />

With insulation displacement system,<br />

max. data transfer rate 12 Mbit/s<br />

Without PG interface 6ES7 972-0BA50-0XA0<br />

With PG interface 6ES7 972-0BB50-0XA0<br />

PROFIBUS FastConnect RS 485<br />

bus connector Plug 180<br />

With 180° cable outlet, with insulation<br />

displacement system, for<br />

connection of PC, PG, OP<br />

Other bus connectors<br />

See the IK PI catalog<br />

6GK1 500-0FC00<br />

RS 485 Repeater for PROFIBUS<br />

Data transfer rate up to max. 12<br />

Mbit/s,<br />

DC 24 V, IP20 housing<br />

6ES7 972-0AA01-0XA0<br />

Diagnostic Repeater RS 485<br />

For connection of up to 2 segments<br />

to PROFIBUS DP; with<br />

online diagnostics function for the<br />

monitoring of bus cables<br />

6ES7 972-0AB01-0XA0<br />

Active RS 485 Terminating Element<br />

for PROFIBUS<br />

For terminating bus segments for<br />

data transfer rates of 9.6 Kbit/s to<br />

12 Mbit/s<br />

6ES7 972-0DA00-0AA0<br />

RS485-iS Coupler<br />

PROFIBUS must be run intrinsically<br />

safely in hazardous areas<br />

through installation of a field bus<br />

isolating transformer<br />

6ES7 972-0AC80-0XA0<br />

Bus Connector<br />

Connector with special (passive)<br />

terminating resistor for terminating<br />

the RS485-iS<br />

6ES7 972-0DA30-0XA0<br />

9/10<br />

<strong>Siemens</strong> ST PCS 7 · October 2004


Communication<br />

PROFIBUS DP<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

Fiber optic cable<br />

■ Overview<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

Glass fiberoptic cables are 2-fiber cables for optical PROFIBUS<br />

networks in the indoor <strong>and</strong> outdoor area.<br />

FIBER OPTIC CABLE<br />

st<strong>and</strong>ard cable, splittable<br />

Preassembled with 4 BFOC con-<br />

The st<strong>and</strong>ard FIBER OPTIC CABLE is available in fixed lengths, nectors<br />

preassembled with 4 BFOC connectors. A BFOC connector set<br />

with 20 connectors is also available.<br />

Preferred lengths<br />

1 m 6XV1 820-5BH10 B)<br />

Optical Link Module<br />

5 m 6XV1 820-5BH50 B)<br />

Optical Link Modules (OLM) permit the construction of optical<br />

<strong>and</strong> hybrid (electrical/optical) networks in line, tree, ring or star<br />

topology. The maximum distance between two OLMs can be up<br />

10 m<br />

20 m<br />

6XV1 820-5BN10<br />

6XV1 820-5BN20<br />

B)<br />

B)<br />

to 15 km. The PROFIBUS OLM/G12 is equipped with one RS 485<br />

interface <strong>and</strong> two glass fiberoptic cable interfaces (4 BFOC<br />

sockets). The OLM enables a fiberoptic line length of up to<br />

3,000 m. Errors are quickly located by means of signal contacts<br />

<strong>and</strong> a measurement output.<br />

50 m<br />

Other lengths <strong>and</strong> cables<br />

BFOC Connector Set<br />

6XV1 820-5BN50<br />

See the IK PI catalog<br />

B)<br />

1)<br />

For st<strong>and</strong>ard <strong>and</strong> trailing FIBER<br />

OPTIC CABLES, 20 pcs<br />

6GK1 901-0DA20-0AA0 B)<br />

PROFIBUS OLM/G12<br />

Optical link module with 1 x RS<br />

485 <strong>and</strong> 2 x glass FOC interfaces<br />

(4 BFOC sockets), for st<strong>and</strong>ard<br />

distances up to 3,000 m, with signal<br />

contact <strong>and</strong> measuring output<br />

6GK1 502-3CB10 B)<br />

B) Subject to export regulations: AL: N, ECCN: EAR99H<br />

1) Note: You can order supplementary components for the SIMATIC NET<br />

range of cables from your local partner.<br />

Technical advice can be obtained from:<br />

J. Hertlein, A&D SE V22<br />

Tel.: +49 (911) 750 44 65, Fax: +49 (911)750 99 91<br />

E-mail: juergen.hertlein@siemens.com<br />

9/11<br />

9


9<br />

Communication<br />

PROFIBUS DP<br />

Plastic fiber optic cable<br />

■ Overview<br />

■ Design<br />

SIMATIC NET plastic fiberoptic cables can be used for the con- Different versions of plastic FOC are available:<br />

struction of optical PROFIBUS DP networks for indoor applications.<br />

Plastic fiberoptic cables are easy to assemble on-site with<br />

2 x 2 simplex connectors. The maximum cable length between<br />

two DP devices is 50 m.<br />

PROFIBUS plastic fiber optic st<strong>and</strong>ard cable<br />

rugged round cable with purple PVC outer casing <strong>and</strong> Kevlar<br />

tension-relief elements as well as plastic fibers with rugged<br />

polyamide inner casing. For indoor applications with cable<br />

Using SIMATIC PCS 7, plastic fiberoptic cables are an alterna- lengths up to 50 m<br />

tive for automation system connections of ET 200M with only failsafe<br />

I/O modules when compliance with SIL 3 is dem<strong>and</strong>ed for<br />

the failsafe application. Plastic fiberoptic cables are then used to<br />

connect the ET 200Ms through Optical Bus Terminals (OBT) to<br />

the electrical bus cable of the PROFIBUS DP. The advantage of<br />

this configuration is that it eliminates the disconnecting module<br />

for decoupling the signal between the IM <strong>and</strong> the failsafe mod-<br />

PROFIBUS plastic fiberoptic, duplex core<br />

flat double core with PVC inner casing <strong>and</strong> no outer casing, for<br />

indoor applications with low mechanical loads, e.g. inside<br />

cabinets. Cable length up to 50 m.<br />

To use the plastic FOC, following items are required in addition<br />

to the OBT:<br />

ules, which is otherwise obligatory for the direct electrical con- Simplex connector/polishing set (set with 100 simplex connection<br />

of the ET 200M (only failsafe modules in a rack with nectors <strong>and</strong> 5 polishing sets)<br />

IM 153-2).<br />

Stripping tool set for removing the outer casing <strong>and</strong> core casing<br />

Plug adapter for using simplex connectors with the integrated<br />

FO interfaces (e.g. IM 153-2 FO)<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

PROFIBUS OBT<br />

Optical bus terminal for connecting<br />

a PROFIBUS station or an<br />

RS 485 segment without integrated<br />

optical interface to the<br />

optical PROFIBUS; without simplex<br />

connector<br />

6GK1 500-3AA00<br />

PROFIBUS Plastic Fiber Optic,<br />

St<strong>and</strong>ard Cable<br />

Robust round cable with 2 plastic<br />

fiberoptic cores, PVC external<br />

sheath <strong>and</strong> PA internal sheath,<br />

without connectors, for indoor<br />

6XV1 821-0AH10 B)<br />

use, sold by the meter<br />

OBT for PROFIBUS DP<br />

PROFIBUS Plastic Fiber Optic, 6XV1 821-2AN50 B)<br />

With the OBT (Optical Bus Terminal) for PROFIBUS it is possible Duplex Core<br />

to connect a PROFIBUS DP station with an integrated optical in- Plastic fiberoptic cable with<br />

terface to an RS 485 segment or a PROFIBUS DP station without 2 cores, PVC sheath, without con-<br />

an integrated optical interface. Plastic fiberoptic cables can be<br />

used for the optical connection between the PROFIBUS DP station<br />

with an integrated optical interface <strong>and</strong> the OBT.<br />

nectors, for use in environments<br />

with low mechanical stress, 50-m<br />

ring<br />

PROFIBUS Plastic Fiber Optic,<br />

Simplex Connector/<br />

Polishing Set<br />

100 simplex connectors <strong>and</strong><br />

5 polishing sets for assembling<br />

PROFIBUS plastic fiberoptic<br />

cables for the optical PROFIBUS<br />

DP<br />

6GK1 901-0FB00-0AA0 B)<br />

PROFIBUS Plastic Fiber Optic,<br />

Stripping Tool Set<br />

To remove the external or core<br />

sleeve of plastic fiberoptic cables<br />

6GK1 905-6PA10 B)<br />

Connection Adapter<br />

Pack of 50, for using simplex connectors<br />

with the integrated FO<br />

interfaces (e.g. IM 153-2 FO); for<br />

25 modules<br />

6ES7 195-1BE00-0XA0<br />

9/12<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

B) Subject to export regulations: AL: N, ECCN: EAR99H


■ Overview<br />

PROFIBUS DP lines can be connected to a SIMATIC PCS 7 automation<br />

system through up to 4 internal interfaces in the CPU<br />

<strong>and</strong> up to 10 additional CP 443-5 Extended communication<br />

modules.<br />

If the module slot provided in the CPU for the PROFIBUS connection<br />

is not equipped yet, an IF 964-DP interface module will<br />

be required in addition. The CP 443-5 Extended communications<br />

processor is required for the PROFIBUS connection when<br />

data record routing is used with SIMATIC PDM.<br />

Benefits of the communication module:<br />

Compact design 9-pin Sub-D connector for connecting to<br />

PROFIBUS DP<br />

Easy assembly<br />

Can be installed in a slot of the AS subrack; connection with<br />

the other S7-400 modules through the backplane bus<br />

Can be operated without fans; a backup battery or memory<br />

module is not required.<br />

Communication<br />

PROFIBUS DP<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

AS connection<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

CP 443-5 Extended<br />

6GK7 443-5DX03-0XE0<br />

Communications module for connection<br />

of SIMATIC S7-400 to<br />

PROFIBUS as DP master or for S7<br />

communication,<br />

for data set routing of SIMATIC<br />

PDM<br />

IF 964-DP<br />

6ES7 964-2AA01-0AB0<br />

Interface module for connection<br />

of another PROFIBUS DP line, for<br />

plugging into a free DP module<br />

slot of the CPU<br />

9/13<br />

9


9<br />

Communication<br />

PROFIBUS DP<br />

Y-link<br />

■ Overview<br />

The Y-link is a bus coupler for transition from a redundant<br />

PROFIBUS DP master system to a single-channel<br />

PROFIBUS DP master system. It can be used for connecting devices<br />

with only one PROFIBUS DP interface to the redundant<br />

PROFIBUS DP master system AS 414H/ AS 417H.<br />

9/14<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

■ Design<br />

The Y-link comprises:<br />

2 IM 157interface modules<br />

1 Y-coupler incl. RS 485 repeater<br />

1 BM IM 157 bus module<br />

1 BM Y-coupler bus module<br />

Evaluation of the Y-link diagnostics (<strong>and</strong> hence indirectly of the<br />

connected DP st<strong>and</strong>ard slaves) is supported by driver blocks.<br />

We recommend a redundant 24 V DC power supply, e.g. with<br />

two PS 307/PS 305 load power supplies.<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

Y link<br />

6ES7 197-1LA02-0XA0<br />

For connection of devices with<br />

only one PROFIBUS DP interface<br />

to a fault-tolerant automation system<br />

PS 307 Load Power Supply<br />

Including connection assembly;<br />

120/230 V AC; 24 V DC<br />

- 2 A; 50 mm wide 6ES7 307-1BA00-0AA0<br />

- 5 A; 80 mm wide 6ES7 307-1EA00-0AA0<br />

- 5 A, extended temperature 6ES7 307-1EA80-0AA0<br />

range; 80 mm wide<br />

- 10A, 200mm wide 6ES7 307-1KA01-0AA0<br />

PS 305 Load Power Supply<br />

Including connection assembly;<br />

24/48/60/110 V DC; 24 V DC<br />

- 2 A, extended temperature 6ES7 305-1BA80-0AA0<br />

range; 80 mm wide


■ Overview<br />

The transmission technology of the PROFIBUS PA profile is tailored<br />

to the needs of the process industry. The st<strong>and</strong>ardized<br />

communications services guarantee interoperability between<br />

multi-vendor field devices <strong>and</strong> remote parameterization of the<br />

field devices during operation.<br />

The PROFIBUS PA networks are based on electrical data transfer<br />

components. Data <strong>and</strong> the power supply are conveyed over<br />

a shielded 2-wire cable. Network lengths of up to approx. 1.9 km<br />

are possible with line, tree <strong>and</strong> star topologies. The passive terminating<br />

element for PROFIBUS PA (SpliTConnect terminator) is<br />

used for the termination of bus segments. The DP/PA Link is preferred<br />

for the gateway to the PROFIBUS DP.<br />

With SIMATIC PCS 7, communication between the automation<br />

system <strong>and</strong> the field devices takes place through token blocks<br />

in the CPU which cover all field device types. These token<br />

blocks are configured with the engineering system, which also<br />

creates the configuration data that are loaded into the<br />

DP/PA Link <strong>and</strong> the field devices during startup. Parameterization,<br />

commissioning <strong>and</strong> diagnostics are performed by the<br />

SIMATIC PDM process device manager, which is integrated in<br />

the engineering system.<br />

Communication<br />

PROFIBUS PA<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

Introduction<br />

■ Benefits<br />

The advantages of distributed field automation using the<br />

PROFIBUS PA are: less hardware, most cost-effective engineering,<br />

higher operational reliability <strong>and</strong> straightforward maintenance.<br />

These advantages are highlighted by the following characteristics:<br />

New plant concepts enabled by modularity <strong>and</strong> consistency<br />

from the sensor up into the control level<br />

Implementation of intrinsically safe applications through use of<br />

the field bus in use hazardous areas<br />

Reduced costs of configuration through simple, central engineering<br />

of the field devices (PROFIBUS PA <strong>and</strong> HART with<br />

SIMATIC PDM, multi-vendor devices also possible)<br />

Simple installation through 2-wire cable for joint conveyance<br />

of power supply <strong>and</strong> data<br />

Reduced commissioning costs through simplified loop check<br />

Low service costs thanks to simple wiring <strong>and</strong> more extensive<br />

diagnostics options<br />

9/15<br />

9


9<br />

Communication<br />

PROFIBUS PA<br />

Basic components<br />

■ Overview<br />

The DP/PA Link is a very simple gateway that interconnects the<br />

two bus systems PROFIBUS DP <strong>and</strong> PROFIBUS PA, but decouples<br />

their data transfer rates. It is thus possible to combine<br />

PROFIBUS DP <strong>and</strong> PROFIBUS PA without impairing the time-related<br />

performance of PROFIBUS DP.<br />

■ Design<br />

The DP/PA Link can be operated on PROFIBUS DP st<strong>and</strong>ard<br />

masters <strong>and</strong> enables the construction of large systems with<br />

large addressing ranges <strong>and</strong> high dem<strong>and</strong>s of cycle time.<br />

It is formed from the IM 157 interface module <strong>and</strong> up to<br />

five DP/PA couplers. DP/PA couplers are available in Ex <strong>and</strong><br />

non-Ex versions. All components of the DP/PA Link are interconnected<br />

through the S7 backplane bus.<br />

The use of active bus modules as the backplane bus enables<br />

hot swapping of individual modules <strong>and</strong> redundant configuration<br />

of the IM 157 interface module for PROFIBUS DP. Applications<br />

with a high level of availability are thus possible in conjunction<br />

with the AS 414H / AS 417H automation systems.<br />

The semi-modular DP/PA Link can be extended to a maximum of<br />

five PROFIBUS PA lines per DP connection, according to the<br />

number of DP/PA couplers. The PROFIBUS PA lines are physically<br />

separated as regards current input, but form one bus system<br />

in communication terms.<br />

Following basic components are available to configure the<br />

DP/PA Link:<br />

Load power supply PS 307 for 120/230 V AC; 24 V DC, version<br />

in 2, 5 or 10 A, or<br />

load power supply PS 305 for 24/48/60/110 V DC; 24 V DC,<br />

2A<br />

IM 157 interface module<br />

DP/PA coupler (Ex <strong>and</strong> non-Ex version)<br />

Hot swapping<br />

Following components are required in addition or as alternatives<br />

to the DP/PA Link basic components for the hot swapping function<br />

<strong>and</strong> for a redundant PROFIBUS DP interface module:<br />

Bus modules for hot swapping<br />

- BM IM 157 for two IM 157 modules, for redundant <strong>and</strong> nonredundant<br />

design, for extended temperature range<br />

- BM DP/PA for one DP/PA coupler, for extended temperature<br />

range (up to five DP/PA couplers per DP/PA Link possible)<br />

Profile rail for hot swapping (as an alternative to the st<strong>and</strong>ard<br />

profile rail)<br />

9/16<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

■ Technical specifications<br />

DP/PA coupler<br />

Connection for PROFIBUS PA<br />

Intrinsically safe version 2-pin screw-type terminal, permanently<br />

integrated terminating<br />

resistor<br />

Output current max. 110 mA<br />

Output voltage 13...14 V DC<br />

Non-intrinsically safe version 4-pin screw-type terminal, switchable<br />

terminating resistor<br />

Output current max. 400 mA<br />

Output voltage 19... V DC<br />

Connection for PROFIBUS DP 9-pin Sub-D plug,<br />

contact assignment as described<br />

in IEC 61158/EN 50170<br />

Backplane bus Connection through S7 backplane<br />

bus connector (only necessary<br />

for PA Link ); non-isolated<br />

The active BM DP/PA bus modules<br />

are required for the hot<br />

swapping function<br />

Displays Bus activity DP (yellow)<br />

Bus activity PA (yellow)<br />

Supply voltage 24 V DC (green)<br />

Current consumption<br />

Ex version Max. 400 mA<br />

Non-Ex version Max. 750 mA<br />

Power loss<br />

Ex version Approx. 7 W<br />

Non-Ex version Approx. 7 W<br />

Operating temperature<br />

Ex version -25 ... +60 °C<br />

Non-Ex version -25 ... +60 °C<br />

Dimensions (W x H x D) in mm 80 x 125 x 130


Communication<br />

PROFIBUS PA<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

Basic components<br />

■ Technical specifications<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

IM 157<br />

Function Linking of PROFIBUS DP<br />

(9.6 Kbit/s to 12 Mbit/s, slave<br />

functionality) <strong>and</strong> PROFIBUS PA<br />

PS 307 Load Power Supply<br />

Including connection assembly;<br />

120/230 V AC; 24 V DC<br />

2 A; 50 mm wide 6ES7 307-1BA00-0AA0<br />

with support of the "hot configuration"<br />

function (configuration when<br />

5 A; 80 mm wide 6ES7 307-1EA00-0AA0<br />

the plant is in operation)<br />

5 A, extended temperature 6ES7 307-1EA80-0AA0<br />

The DP/PA Link function is only<br />

range; 80 mm wide<br />

implemented by extending the<br />

IM 157 with one or more DP/PA<br />

couplers. St<strong>and</strong>-alone operation<br />

of the IM 157 is not possible.<br />

10A, 200mm wide<br />

PS 305 Load Power Supply<br />

24/48/60/110 V DC; 24 V DC<br />

6ES7 307-1KA01-0AA0<br />

Up to 5 DP/PA couplers <strong>and</strong> as 2 A, extended temperature 6ES7 305-1BA80-0AA0<br />

many as 64 slaves are connect- range; 80 mm wide<br />

able<br />

Isolation from the higher-level DP<br />

Master <strong>System</strong><br />

IM 157<br />

Interface module for DP/PA Link<br />

<strong>and</strong> Y-Link<br />

6ES7 157-0AA82-0XA0<br />

Interfaces<br />

DP/PA coupler<br />

Connection for PROFIBUS DP 9-pin Sub-D plug, contact assignment<br />

as described in<br />

For transition from RS 485 to<br />

IEC 61158<br />

IEC 61158/EN 50170, Vol. 2<br />

Intrinsically safe version 6ES7 157-0AD82-0XA0<br />

Backplane bus Connection through S7 bus backplane<br />

connector, non-isolated<br />

Bus modules <strong>and</strong> profile rails for<br />

hot swapping (see the section<br />

Non-intrinsically safe version<br />

St<strong>and</strong>ard Profile Rails<br />

(without hot swapping)<br />

6ES7 157-0AC81-0XA0<br />

"Hot swapping") are required for 482 mm wide (19 inches) 6ES7 390-1AE80-0AA0<br />

the hot swapping function <strong>and</strong> for<br />

a redundant PROFIBUS DP inter-<br />

530 mm wide 6ES7 390-1AF30-0AA0<br />

face module.<br />

Bus Modules for Hot Swapping<br />

Displays SF (red)<br />

BF DP (red)<br />

BF PA (red)<br />

BM IM 157<br />

For 2 IM 157 modules, for redundant<br />

<strong>and</strong> non-redundant config-<br />

6ES7 195-7HD80-0XA0<br />

Supply voltage<br />

Active (yellow)<br />

24 V DC (green)<br />

24 V DC<br />

uration, for extended<br />

temperature range, for hot<br />

swapping function,<br />

permissible operating tempera-<br />

Current consumption max. 100 mA (in DP/PA Link)<br />

ture -25...+60°C<br />

max. 200 mA (in Y-Link)<br />

BM DP/PA<br />

6ES7 195-7HF80-0XA0<br />

Power loss Approx. 2 W (in DP/PA Link)<br />

Approx. 4 W (in Y-Link)<br />

For 1 DP/PA coupler,<br />

for extended temperature range,<br />

for hot swapping function,<br />

Voltage failure bridging 20 ms<br />

permissible operating tempera-<br />

Mechanical design 4-pin screw terminal, short-cirture<br />

-25...+60°C<br />

cuiting link between PE <strong>and</strong> M24, Profile Rail for Hot Swapping<br />

for earth-free operation the shortcircuiting<br />

link must be removed<br />

482 mm wide (19 inches) 6ES7 195-1GA00-0XA0<br />

Permissible operating temperature<br />

(independent of this, the DP interface<br />

is always earth-free)<br />

-25...+60 °C<br />

530 mm wide<br />

620 mm wide<br />

6ES7 195-1GF30-0XA0<br />

6ES7 195-1GG30-0XA0<br />

Dimensions (W x H x D) in mm 40 x 125 x 130<br />

Configuration with STEP 7 in version 5.2 <strong>and</strong><br />

higher<br />

9/17<br />

9


9<br />

Communication<br />

PROFIBUS PA<br />

FastConnect/SpliTConnect<br />

■ Overview<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

PROFIBUS FC process cables, color-coded for the various ap- FC Process Cable<br />

plications (Ex, non-Ex area) are available for designing field bus 2-core, shielded<br />

networks in accordance with IEC 61158-2 (e.g. PROFIBUS PA).<br />

Blue for Ex applications 6XV1 830-5EH10<br />

The FastConnect stripping tool can be used to strip the FC process<br />

cable for PROFIBUS PA to the correct length for casing <strong>and</strong><br />

shield.<br />

Black for non-Ex applications<br />

Sold by the meter:<br />

Max. delivey unit 1000 m, mini-<br />

6XV1 830-5FH10<br />

■ Design<br />

mum ordering quantity 20 m<br />

PROFIBUS FastConnect<br />

Stripping Tool<br />

Stripping tool for rapid stripping<br />

of insulation from PROFIBUS<br />

FastConnect bus cables<br />

6GK1 905-6AA00<br />

PROFIBUS FastConnect<br />

Blade Cassettes<br />

Spare blade cassettes for the<br />

PROFIBUS FastConnect stripping<br />

tool, 5 pcs<br />

6GK1 905-6AB00<br />

SpliTConnect Tap<br />

For design of PROFIBUS PA segments<br />

<strong>and</strong> connection of PA field<br />

devices, insulation displacement<br />

system, IP67, 10 pcs<br />

6GK1 905-0AA00<br />

SpliTConnect M12 Outlet<br />

Replacement element for direct<br />

connection of PA field devices to<br />

the SpliTConnect Tap, 5 pcs<br />

6GK1 905-0AB10<br />

SpliTConnect Coupler<br />

Connection element for cascading<br />

SpliTConnect Taps in order to<br />

configure star points, 10 pcs<br />

SpliTConnect Terminator<br />

For termination of PROFIBUS PA<br />

6GK1 905-0AC00<br />

segments, 5 pcs<br />

SpliTConnect<br />

Terminator (Ex); use possible in 6GK1 905-0AD00<br />

The SpliTConnect Tap enables the design of field bus segments hazardous area<br />

according to IEC 61158-2 with field device connection points. Terminator (non-Ex); use not 6GK1 905-0AE00<br />

The SpliTConnect coupler can be used to construct a<br />

possible in hazardous area<br />

PROFIBUS PA hub by connecting SpliTConnect taps in series. SpliTConnect M12 Jack<br />

6GK1 905-0AF00<br />

By replacing the contacting screw with the SpliTConnect Terminator,<br />

the SpliTConnect tap can be used as a bus terminating element.<br />

The terminals can be connected directly through the FC process<br />

cable. Using the SpliTConnect M12 outlet, PA field devices can<br />

also be connected to the SpliTConnect Tap by M12 connection.<br />

The SpliTConnect M12 jack is a connecting element between<br />

FC process cable <strong>and</strong> M12 connector on the PROFIBUS PA field<br />

device. For details of SpliTConnect network components, see<br />

the IK PI catalog.<br />

Connection element between<br />

FC process cable <strong>and</strong> M12 plug<br />

on the PROFIBUS PA field device,<br />

5pcs<br />

9/18<br />

<strong>Siemens</strong> ST PCS 7 · October 2004


Communication<br />

Other communication<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

AS-Interface<br />

■ Overview<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

CP 343-2<br />

Communications module for connection<br />

of SIMATIC S7-300 <strong>and</strong><br />

ET 200M to AS-Interface, without<br />

front connector<br />

6GK7 343-2AH00-0XA0<br />

Front Connector<br />

6ES7 392-1AJ00-0AA0<br />

The actuator-sensor interface (AS-Interface) is a multi-vendor<br />

networking system for simple - usually binary - actuators <strong>and</strong><br />

20-pin, with screw contacts<br />

CP 343-2 Manual<br />

sensors in the lowest field area. AS-Interface enables a wiring Including software <strong>and</strong> examples<br />

loom with parallel wiring to be replaced by a simple two-wire cable<br />

shared by all sensors or actuators.<br />

The AS-Interface works by the master-slave principle. Sensors/actuators<br />

connected through the AS-Interface cable are<br />

German<br />

English<br />

French<br />

6GK7 343-2AH00-8AA0<br />

6GK7 343-2AH00-8BA0<br />

6GK7 343-2AH00-8CA0<br />

controlled by the master as slaves.<br />

Italian 6GK7 343-2AH00-8EA0<br />

Note:<br />

DP/AS-Interface Link 20E<br />

6GK1 415-2AA01<br />

AS-Interface is integrated in SIMATIC pcs 7 as a subordinate<br />

bus. Consequently, this bus does not offer the full functionality of<br />

SIMATIC PCS 7; this applies in particular to diagnostics functions.<br />

Further information, see Catalog IK PI.<br />

PROFIBUS DP/ AS-Interface<br />

gateway, degree of protection<br />

IP20<br />

DP/AS-Interface Link 20E Manual<br />

■ Design<br />

Including type <strong>and</strong> GSD files<br />

German 6GK1 971-2DS01-0AA0<br />

<strong>System</strong> components<br />

English 6GK1 971-2DS01-0AA1<br />

The basic components of a system installation are:<br />

French 6GK1 971-2DS01-0AA2<br />

CP 343-2 AS-Interface master module for ET 200M or/<strong>and</strong><br />

DP/AS-Interface link for connection of an AS-Interface line to<br />

PROFIBUS DP<br />

AS-Interface shaped cable (use of round cable also possible<br />

if preferred)<br />

Modules for connecting st<strong>and</strong>ard sensors/actuators<br />

Power supply unit for powering the slaves<br />

Actuators <strong>and</strong> sensors with integrated ASIC slave<br />

Address programming device for setting the slave address<br />

Spanish<br />

Italian<br />

6GK1 971-2DS01-0AA3<br />

6GK1 971-2DS01-0AA4<br />

9/19<br />

9


9<br />

Communication<br />

Other communication<br />

EIB instabus<br />

■ Overview<br />

DB/EIB Link connects the production automation <strong>and</strong> process<br />

automation to building installation systems<br />

Data is exchanged between PROFIBUS DP <strong>and</strong> EIB (European<br />

Installation Bus)<br />

Compact housing to degree of protection IP20, for use in<br />

switchgear cabinets as well as in distribution systems<br />

Configurable as a DP slave with STEP 7 or COM PROFIBUS<br />

st<strong>and</strong>ard tools <strong>and</strong> with the EIB configuring software ETS 2<br />

Note :<br />

EIB instabus is integrated in SIMATIC PCS 7 as a subordinate<br />

bus. Consequently, this bus does not offer the full functionality of<br />

SIMATIC PCS 7; this applies in particular to diagnostics functions.<br />

Further information, see Catalog IK PI.<br />

9/20<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

DP/EIB Link<br />

Gateway for data exchange<br />

between PROFIBUS DP <strong>and</strong> EIB<br />

6GK1 415-0AA01 E)<br />

DP/EIB Link Manual<br />

Including GSD file <strong>and</strong> ETS database<br />

entry<br />

German 6GK1 971-3DA00-0AA0<br />

English 6GK1 971-3DA00-0AA1<br />

E) Subject to export regulations: AL: N, ECCN: 5A991


Communication<br />

Other communication<br />

■ Overview<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

Modbus is connected to PROFIBUS DP using an ET 200M with<br />

a CP 341 communications module. The latter enables the fast<br />

CP 341 communications processor<br />

6ES7 341-1AH01-0AE0<br />

<strong>and</strong> efficient exchange of data through point-to-point coupling. with one RS 232 C (V.24) interface<br />

The CP 341 communications module is available in 3 versions RS 232 connecting cable<br />

with different transmission physics:<br />

for linking to SIMATIC S7<br />

RS 232C (V.24),<br />

5 m 6ES7 902-1AB00-0AA0<br />

20 mA (TTY)<br />

10 m 6ES7 902-1AC00-0AA0<br />

RS 422/RS 485 (X.27)<br />

The MODBUS Master or MODBUS Slave loadable drivers are<br />

15 m 6ES7 902-1AD00-0AA0<br />

needed for the Modbus coupling.<br />

CP 341 communications processor<br />

with one 20 mA (TTY) interface<br />

20 mA (TTY) connecting cable<br />

for linking to SIMATIC S7<br />

6ES7 341-1BH01-0AE0<br />

5 m 6ES7 902-2AB00-0AA0<br />

10 m 6ES7 902-2AC00-0AA0<br />

50 m 6ES7 902-2AG00-0AA0<br />

CP 341 communications pro- 6ES7 341-1CH01-0AE0<br />

cessor<br />

with one RS 422/485 (X.27) interface<br />

RS 422/485 connecting cable<br />

for linking to SIMATIC S7<br />

5 m 6ES7 902-3AB00-0AA0<br />

10 m 6ES7 902-3AC00-0AA0<br />

50 m 6ES7 902-3AG00-0AA0<br />

CP 341 manual<br />

German 6ES7 341-1AH00-8AA0<br />

Englisch 6ES7 341-1AH00-8BA0<br />

French 6ES7 341-1AH00-8CA0<br />

Italian 6ES7 341-1AH00-8EA0<br />

Loadable drivers for CP 341<br />

MODBUS Master (RTU format)<br />

Single license 6ES7 870-1AA01-0YA0<br />

Single license, without software 6ES7 870-1AA01-0YA1<br />

<strong>and</strong> documentation<br />

MODBUS Slave (RTU format)<br />

Single license 6ES7 870-1AB01-0YA0<br />

Single license, without software 6ES7 870-1AB01-0YA1<br />

<strong>and</strong> documentation<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

Modbus<br />

9/21<br />

9


9<br />

9/22<br />

Communication<br />

<strong>Siemens</strong> ST PCS 7 · October 2004


<strong>Automation</strong> systems<br />

10/2 Introduction<br />

10/3 Innovated<br />

st<strong>and</strong>ard automation systems<br />

10/6 Fault-tolerant<br />

automation systems<br />

10/9 Failsafe automation systems<br />

<strong>Siemens</strong> ST PCS 7 · October 2004


10<br />

<strong>Automation</strong> systems<br />

Introduction<br />

■ Overview<br />

■ Technical specifications<br />

Select SIMATIC S7-400 components can be combined in the au-<br />

AS 416-3 AS 417-4/<br />

tomation systems of the SIMATIC PCS 7 process control system.<br />

AS 417H<br />

The following characteristics make the SIMATIC S7-400 predes- Analog value measurements 125 150<br />

tined for use as a SIMATIC PCS 7 automation system:<br />

Digital value measurements 300 400<br />

modular <strong>and</strong> fan-free design,<br />

Dosing rates 10 15<br />

high degree of expansion capability <strong>and</strong> robust design,<br />

Motors 125 150<br />

simple or redundant design,<br />

PID controls 100 130<br />

comprehensive communications capabilities,<br />

Valves 125 150<br />

integral system functions <strong>and</strong><br />

simple connection of central or distributed I/Os.<br />

SFC<br />

Steps<br />

30<br />

300<br />

50<br />

500<br />

Various automation systems are available with a price/performance<br />

ratio which can be tailored to your system requirements.<br />

All automation systems are equipped with an onboard<br />

or<br />

Digital inputs DI 675 850<br />

PROFIBUS DP field-bus connection. Additional PROFIBUS communication<br />

modules can be fitted if required.<br />

Digital outputs DO<br />

Analog inputs AI<br />

260<br />

210<br />

315<br />

275<br />

■ Design<br />

Analog outputs AO 100 130<br />

The automation systems are delivered as preassembled <strong>and</strong><br />

tested complete systems without surcharge, <strong>and</strong> are comprised<br />

Typical mixed quantity frameworks for SIMATIC PCS 7 automation systems<br />

of:<br />

Note:<br />

Subracks with 9 or 18 slots, which can be physically separate<br />

in the case of redundant systems<br />

The values quoted here are not AS-specific maximum values for the particular<br />

item but represent a typical distribution of the available total capacity<br />

of the AS during mixed operation of all the items of an assembled<br />

St<strong>and</strong>ard CPU 414-3, 416-2, 416-3 or 417-4 as well as the redundant<br />

CPU 414-4H <strong>and</strong> 417-4H<br />

24 V DC or 120/230 V AC power supply incl. backup battery<br />

(batteries)<br />

Main memory from 768 Kbyte to 20 Mbyte<br />

Memory card with 1 to 16 Mbyte RAM<br />

Connection to Industrial Ethernet<br />

A corresponding Runtime licence is required per automation<br />

system when using the "PCS 7 Library Blocks V6.0” library (see<br />

ordering data for accessories).<br />

block. Individual calculation of these quantity frameworks is possible using<br />

the configurator software, which can be found on the current CD-<br />

ROM of the CA 01 Interactive Catalog.<br />

10/2<br />

<strong>Siemens</strong> ST PCS 7 · October 2004


■ Overview<br />

Compared to the previous st<strong>and</strong>ard automation systems, the innovated<br />

st<strong>and</strong>ard automation systems have the following key<br />

features:<br />

7 Improved processing capacity (1.6 - 3x as fast)<br />

7 Significantly improved communications capacity<br />

7 Larger integrated main memory (5x for AS 417, 1.75 - 2x for<br />

AS 414 <strong>and</strong> AS 416)<br />

The AS 414-3 automation systems are tailored for small applications<br />

with small quantity frameworks. They therefore meet the dem<strong>and</strong><br />

for low-cost initial implementation with a modular <strong>and</strong> scalable<br />

system. Larger quantity frameworks can be implemented<br />

with the AS 416-2, AS 416-3 <strong>and</strong> AS 417-4 automation systems.<br />

These systems are preferred for medium-sized systems <strong>and</strong> bigger.<br />

The automation systems are available complete with subrack,<br />

power supply, CPU, memory card <strong>and</strong> PROFIBUS DP interface.<br />

They are delivered already assembled <strong>and</strong> tested. Each version<br />

has a different main memory:<br />

AS 414-3: Main memory 1.4 MByte<br />

(0.7 MByte for program <strong>and</strong> data respectively)<br />

AS 416-2: Main memory 2.8 MByte<br />

(1.4 MByte for program <strong>and</strong> data respectively)<br />

AS 416-3: Main memory 5.6 MByte<br />

(2.8 MByte for program <strong>and</strong> data respectively)<br />

AS 417-4: Main memory 20 Mbyte<br />

(10 Mbyte for program <strong>and</strong> data respectively)<br />

All systems are available with a choice of 120/230 V AC or<br />

24 V DC power supply.<br />

■ Technical specifications<br />

Selected technical data<br />

<strong>Automation</strong> systems<br />

Innovated st<strong>and</strong>ard automation systems<br />

AS type Integrated main<br />

memory in Mbyte<br />

AS 414-3: 1,4 60<br />

AS 416-2: 2,8 40<br />

AS 416-3: 5,6 40<br />

AS 417-4: 20 30<br />

Processing time in<br />

ns<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

10/3<br />

10


10<br />

<strong>Automation</strong> systems<br />

Innovated st<strong>and</strong>ard automation systems<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

Ordering units for automation systems<br />

AS 414-3 <strong>Automation</strong> <strong>System</strong><br />

Comprising:<br />

controller type 414-3 with<br />

3 interfaces (MPI/DP, DP <strong>and</strong> slot<br />

for IF module), 1.4 Mbyte main<br />

memory (0.7 Mbyte available for<br />

program <strong>and</strong> data respectively),<br />

memory card 2 Mbyte RAM,<br />

2 backup batteries, CP 443-<br />

1EX11 communications module<br />

for connection to Industrial Ethernet<br />

plant bus<br />

UR1 subrack (18 slots):<br />

- PS 407 power supply; 20 A for 6ES7 654-3QD47-0XX0<br />

120/230 V AC<br />

- PS 405 power supply; 20 A for 6ES7 654-6QD47-0XX0<br />

24 V DC<br />

UR2 subrack (9 slots):<br />

- PS 407 power supply; 10 A for 6ES7 654-1QD57-0XX0<br />

120/230 V AC<br />

- PS 405 power supply; 10 A for 6ES7 654-4QD57-0XX0<br />

24 V DC<br />

AS 416-2 <strong>Automation</strong> <strong>System</strong><br />

Comprising:<br />

controller type 416-2 with<br />

2 interfaces (MPI/DP <strong>and</strong> DP), 2.8<br />

Mbyte main memory (1.4 Mbyte<br />

available for program <strong>and</strong> data<br />

respectively), memory card 2<br />

Mbyte RAM, 4 backup batteries,<br />

CP 443-1EX11 communications<br />

module for connection to Industrial<br />

Ethernet plant bus<br />

UR1 subrack (18 slots):<br />

- PS 407 power supply; 20 A for 6ES7 654-3JE47-0XX0<br />

120/230 V AC<br />

- PS 405 power supply; 20 A for 6ES7 654-6JE47-0XX0<br />

24 V DC<br />

UR2 subrack (9 slots):<br />

- PS 407 power supply; 10 A for 6ES7 654-1JE57-0XX0<br />

120/230 V AC<br />

- PS 405 power supply; 10 A for 6ES7 654-4JE57-0XX0<br />

24 V DC<br />

10/4<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

AS 416-3 <strong>Automation</strong> <strong>System</strong><br />

Comprising:<br />

controller type 416-3 with<br />

3 interfaces (MPI/DP, DP <strong>and</strong> slot<br />

for IF module), 5.6 Mbyte main<br />

memory (2.8 Mbyte available for<br />

program <strong>and</strong> data respectively),<br />

memory card 8 Mbyte RAM,<br />

2 backup batteries, CP 443-<br />

1EX11 communications module<br />

for connection to Industrial Ethernet<br />

plant bus<br />

UR1 subrack (18 slots):<br />

- PS 407 power supply; 20 A for 6ES7 654-3KF47-0XX0<br />

120/230 V AC<br />

- PS 405 power supply; 20 A for 6ES7 654-6KF47-0XX0<br />

24 V DC<br />

UR2 subrack (9 slots):<br />

- PS 407 power supply; 10 A for 6ES7 654-1KF57-0XX0<br />

120/230 V AC<br />

- PS 405 power supply; 10 A for 6ES7 654-4KF57-0XX0<br />

24 V DC<br />

AS 417-4 <strong>Automation</strong> <strong>System</strong><br />

Comprising:<br />

controller type 417-4 with with<br />

4 interfaces (MPI/DP, DP <strong>and</strong><br />

2 slots for IF modules), 20 Mbyte<br />

main memory (10 Mbyte available<br />

for program <strong>and</strong> data respectively),<br />

memory card 2 Mbyte<br />

RAM, 2 backup batteries,<br />

CP 443-1EX11 communications<br />

module for connection to Industrial<br />

Ethernet plant bus<br />

UR1 subrack (18 slots):<br />

- PS 407 power supply; 20 A for 6ES7 654-3LE47-0XX0<br />

120/230 V AC <strong>and</strong><br />

memory card, 4 Mbyte RAM<br />

- PS 407 power supply; 20 A for 6ES7 654-3LG47-0XX0<br />

120/230 V AC <strong>and</strong><br />

memory card, 16 Mbyte RAM<br />

- PS 405 power supply; 20 A for 6ES7 654-6LE47-0XX0<br />

24 V DC <strong>and</strong><br />

memory card, 4 Mbyte RAM<br />

- PS 405 power supply; 20 A for 6ES7 654-6LG47-0XX0<br />

24 V DC <strong>and</strong><br />

memory card, 16 Mbyte RAM<br />

UR2 subrack (9 slots):<br />

- PS 407 power supply; 10 A for 6ES7 654-1LE57-0XX0<br />

120/230 V AC <strong>and</strong><br />

memory card, 4 Mbyte RAM<br />

- PS 407 power supply; 10 A for 6ES7 654-1LG57-0XX0<br />

120/230 V AC <strong>and</strong><br />

memory card, 16 Mbyte RAM<br />

- PS 405 power supply; 10 A for 6ES7 654-4LE57-0XX0<br />

24 V DC <strong>and</strong><br />

memory card, 4 Mbyte RAM<br />

- PS 405 power supply; 10 A for 6ES7 654-4LG57-0XX0<br />

24 V DC <strong>and</strong><br />

memory card, 16 Mbyte RAM


■ Selection <strong>and</strong> Ordering Data Order No.<br />

Individual components for automation systems<br />

CPU 414-3<br />

Main memory 1.4 Mbyte integrated<br />

(0.7 Mbyte for program<br />

<strong>and</strong> data respectively);<br />

module occupies 2 slots<br />

6ES7 414-3XJ04-0AB0<br />

CPU 416-2<br />

Main memory 2.8 Mbyte integrated<br />

(1.4 Mbyte for program<br />

<strong>and</strong> data respectively);<br />

module occupies 1 slot<br />

6ES7 416-2XK04-0AB0<br />

CPU 416-3<br />

Main memory 5.6 Mbyte integrated<br />

(2.8 Mbyte for program<br />

<strong>and</strong> data respectively);<br />

module occupies 2 slots<br />

6ES7 416-3XL04-0AB0<br />

CPU 417-4<br />

Main memory 20 Mbyte integrated<br />

(10 Mbyte for program<br />

<strong>and</strong> data respectively);<br />

module occupies 2 slots<br />

Memory Card RAM<br />

6ES7 417-4XL04-0AB0<br />

2 Mbyte 6ES7 952-1AL00-0AA0<br />

4 Mbyte 6ES7 952-1AM00-0AA0<br />

8 Mbyte 6ES7 952-1AP00-0AA0<br />

16 Mbyte<br />

Memory Card Flash-EPROM<br />

Only required to update firmware<br />

6ES7 952-1AS00-0AA0 B)<br />

4 Mbyte 6ES7 952-1KM00-0AA0<br />

CP 443-1EX11<br />

Communications module for connection<br />

of SIMATIC S7-400 to<br />

Industrial Ethernet through TCP/IP<br />

<strong>and</strong> ISO; for S7 communication,<br />

S5-compatible communication<br />

(SEND/RECEIVE) with<br />

FETCH/WRITE with or without<br />

RFC 1006, 10/100 Mbit/s, with<br />

AUI/ITP <strong>and</strong> RJ45 connections,<br />

electronic manual on CD;<br />

module occupies 1 slot<br />

6GK7 443-1EX11-0XE0<br />

CP 443-5 Extended<br />

Communications module for connection<br />

of SIMATIC S7-400 to<br />

PROFIBUS as DP master or for S7<br />

communication, for increasing the<br />

number of DP lines, for data set<br />

routing with SIMATIC PDM <strong>and</strong> for<br />

10-ms time stamp,<br />

electronic manual on CD;<br />

module occupies 1 slot<br />

6GK7 443-5DX03-0XE0<br />

IF 964-DP<br />

Interface module for connection<br />

of another PROFIBUS DP line, for<br />

plugging into a free DP module<br />

slot of the CPU<br />

6ES7 964-2AA04-0AB0<br />

<strong>Automation</strong> systems<br />

Innovated st<strong>and</strong>ard automation systems<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

PS 407 power supply module; 6ES7 407-0KA01-0AA0<br />

10 A<br />

120/230 V AC; 5 V DC/10 A,<br />

24 V DC/1 A;<br />

with battery compartment for<br />

2 backup batteries, module occupies<br />

2 slots<br />

PS 407 power supply module; 6ES7 407-0KR00-0AA0<br />

10 A, redundant design possible<br />

120/230 V AC; 5 V DC/10 A,<br />

24 V DC/1 A;<br />

with battery compartment for<br />

2 backup batteries, module occupies<br />

2 slots<br />

PS 407 power supply module; 6ES7 407-0RA01-0AA0<br />

20 A<br />

120/230 V AC; 5 V DC/20 A,<br />

24 V DC/1 A;<br />

with battery compartment for<br />

2 backup batteries, module occupies<br />

3 slots<br />

PS 405 power supply module; 6ES7 405-0KA01-0AA0<br />

10 A<br />

24 V DC; 5 V DC/10 A,<br />

24 V DC/1 A;<br />

with battery compartment for<br />

2 backup batteries, module occupies<br />

2 slots<br />

PS 405 power supply module; 6ES7 405-0KR00-0AA0<br />

10 A, redundant design possible<br />

24 V DC; 5 V DC/10 A,<br />

24 V DC/1 A;<br />

with battery compartment for<br />

2 backup batteries, module occupies<br />

2 slots<br />

PS 405 power supply module; 6ES7 405-0RA01-0AA0<br />

20 A<br />

24 V DC; 5 V DC/20 A, 24 V<br />

DC/1 A;<br />

with battery compartment for<br />

2 backup batteries, module occupies<br />

3 slots<br />

Backup Battery<br />

6ES7 971-0BA00<br />

Type AA, 1.9 Ah<br />

UR1 Subrack<br />

6ES7 400-1TA01-0AA0<br />

18 slots<br />

UR2 Subrack<br />

6ES7 400-1JA01-0AA0<br />

9 slots<br />

Runtime licenses for libraries<br />

PCS 7 Library Blocks V6.0 6ES7 653-2BG06-2YB0<br />

runtime license<br />

valid for one SIMATIC PCS 7 automation<br />

system<br />

trilingual (German, English,<br />

French)<br />

Type of delivery: Certificate of<br />

license<br />

B) Subject to export regulations: AL: N, ECCN: EAR99H<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

10/5<br />

10


10<br />

<strong>Automation</strong> systems<br />

Fault-tolerant automation systems<br />

■ Overview<br />

Fault-tolerant automation systems are used to minimize the risk<br />

of production failures. The higher investment in fault-tolerant automation<br />

systems is often negligible compared to the costs resulting<br />

from production stoppages. The higher the costs resulting<br />

from loss of production, the more important a fault-tolerant<br />

system becomes.<br />

■ Design<br />

The AS 414-4-1H <strong>and</strong> AS 417-4-1H automation systems are initially<br />

equipped with just one CPU. They are used in particular<br />

when the redundant subsystems have to be physically separated<br />

from one another for safety reasons or when the customer<br />

would like to keep open his options for a redundant configuration<br />

in the future. The failsafe AS 414F <strong>and</strong> AS 417F automation systems<br />

are based likewise on this hardware in the corresponding<br />

version.<br />

There are two configuration possibilities for the AS 414-4-1H <strong>and</strong><br />

AS 417-4-1H automation systems:<br />

Configuration with two st<strong>and</strong>ard subracks (UR1 or UR2)<br />

This configuration is ideal when the two redundant subsystems<br />

have to be completely separated for availability reasons.<br />

Each subsystem contains a CPU, a potentially redundant<br />

power supply module (AC), <strong>and</strong> a communication<br />

module for Industrial Ethernet.<br />

Configuration with a UR2-H subrack<br />

The UR2-H compact subrack with split backplane bus is suitable<br />

for configuring a complete fault-tolerant automation system.<br />

For the AS 414-4-1H <strong>and</strong> AS 417-4-1H the UR2-H is<br />

equipped with a CPU, a potentially redundant power supply<br />

module <strong>and</strong> a communications module for Industrial Ethernet.<br />

In the case of the redundant AS 414-4-2H <strong>and</strong> AS 417-4-2H automation<br />

systems, the two subsystems are accommodated in<br />

the UR2-H subrack. Each subsystem is equipped with a CPU, a<br />

potentially redundant power supply module <strong>and</strong> a communications<br />

module for Industrial Ethernet.<br />

In all the configurations described, potentially redundant power<br />

supply modules can be exp<strong>and</strong>ed to redundant configuration by<br />

retrofitting a second power supply module of the same type.<br />

Another 4 sync modules <strong>and</strong> 2 sync cables have to be ordered<br />

in addition to create a redundant system from two AS 414-4-1H<br />

or AS 417-4-1H automation system (UR1/UR2 subracks) <strong>and</strong> to<br />

subsequently exp<strong>and</strong> an AS 414-4-1H or AS 417-4-1H in a UR2-<br />

H subrack into a redundant AS 414-4-2H or AS 417-4-2H system.<br />

10/6<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

Connection of process I/Os<br />

Several PROFIBUS DP lines with distributed process I/Os can be<br />

operated on each sub-AS through the internal PROFIBUS DP interface<br />

or by using additional communications processors.<br />

The distributed ET 200M I/Os are connected through two<br />

IM 153-2 interface modules on a special bus module to two redundant<br />

PROFIBUS DP lines, <strong>and</strong> the intelligent field devices on<br />

the PROFIBUS PA are connected through a redundant<br />

DP/PA link with two IM 157 interface modules. The Y-link can<br />

also be used to connect non-redundant PROFIBUS DP devices<br />

to the redundant PROFIBUS DP.<br />

A mixture of these configurations is also possible.<br />

Communication through the plant bus<br />

The redundant, fault-tolerant AS 414H <strong>and</strong> AS 417H automation<br />

systems are connected by one communication module per sub-<br />

AS to the plant bus. The plant bus can be implemented in the<br />

form of a ring structure, which can also be configured with redundant<br />

architecture if the availability requirements are high.<br />

When there are two redundant rings it makes sense to use two<br />

communication module per sub-AS <strong>and</strong> to distribute their connections<br />

between the two rings. Double faults such as OSM failure<br />

on ring 1 with simultaneous splitting of the bus cable on ring<br />

2 can thus be tolerated.<br />

■ Function<br />

The AS 414H <strong>and</strong> AS 417H models are the fault-tolerant automation<br />

systems for use with SIMATIC PCS 7. They are based on the<br />

1-out-of-2 principle <strong>and</strong> switch to the backup system in the event<br />

of a fault. These systems use a completely redundant design to<br />

maximize availability. This means that all major components<br />

such as CPU, power supply <strong>and</strong> hardware for coupling the two<br />

CPUs are present in pairs. Which other components are also<br />

made available in pairs in the interest of availability depends on<br />

the particular automation task.<br />

The two subsystems of a redundant automation system are electrically<br />

isolated from one another. This increases the system stability<br />

with respect to EMC interference. A redundant automation<br />

system can be installed mechanically in a one- or two-rack architecture.<br />

<strong>Automation</strong> systems are installed in two racks, for example,<br />

if the two parts of the automation system have to be physically<br />

separated from one another by a fire-resistant wall.<br />

Appropriate complete units are available for every type of application.<br />

Mixed operation of redundant <strong>and</strong> st<strong>and</strong>ard systems is<br />

also possible.


■ Selection <strong>and</strong> Ordering Data Order No.<br />

AS 414-4-1H<br />

<strong>Automation</strong> <strong>System</strong><br />

Prepared system with one<br />

CPU 414-4H for physically separated<br />

redundant systems, for<br />

F systems or for later upgrading<br />

to a redundant system<br />

Comprising:<br />

1 x CPU 1414 with 2 interfaces<br />

(MPI/DP <strong>and</strong> DP), 768 Kbyte main<br />

memory (384 Kbyte available<br />

user memory), memory card<br />

1 Mbyte RAM, 2 backup batteries,<br />

CP 443-1 communications<br />

module for connection to Industrial<br />

Ethernet plant bus<br />

PS 407 power supply; 10 A for<br />

120/230 V AC, redundant design<br />

possible, with subrack<br />

- UR1 (18 slots) 6ES7 654-2UA34-0XX0<br />

- UR2 (9 slots) 6ES7 654-2UB34-0XX0<br />

- UR2-H (2 x 9 slots) 6ES7 654-2UR34-0XX0<br />

PS 405 power supply; 10 A for<br />

24 V DC, with subrack<br />

- UR1 (18 slots) 6ES7 654-5UA34-0XX0<br />

- UR2 (9 slots) 6ES7 654-5UB34-0XX0<br />

- UR2-H (2 x 9 slots) 6ES7 654-5UR34-0XX0<br />

AS 414-4-2H<br />

<strong>Automation</strong> <strong>System</strong><br />

Complete fault-tolerant programmable<br />

logic controller with two<br />

CPUs 414-4H<br />

Comprising:<br />

2 x CPU 1414H with each<br />

2 interfaces (MPI/DP <strong>and</strong> DP),<br />

768 Kbyte main memory<br />

(384 Kbyte available user memory),<br />

2 memory cards 1 Mbyte<br />

RAM, 4 backup batteries,<br />

4 sync modules, 2 sync cables,<br />

2 CP 443-1 communications<br />

modules for connection to Industrial<br />

Ethernet plant bus<br />

PS 407 power supply; 10 A for 6ES7 654-2VR34-0XX0<br />

120/230 V AC, redundant design<br />

possible, with<br />

UR2-H subrack (2 x 9 slots)<br />

PS 405 power supply; 10 A for 6ES7 654-5VR34-0XX0<br />

24 V DC, with UR2-H subrack<br />

(2 x 9 slots)<br />

<strong>Automation</strong> systems<br />

Fault-tolerant automation systems<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

AS 417-4-1H<br />

<strong>Automation</strong> <strong>System</strong><br />

Prepared system with one<br />

CPU 417-4H for physically separated<br />

redundant systems, for F<br />

systems or for later upgrading to<br />

a redundant system<br />

Comprising:<br />

1 x CPU 1414H with 2 interfaces<br />

(MPI/DP <strong>and</strong> DP), 4,000 Kbyte<br />

main memory (2,000 Kbyte available<br />

user memory), memory card<br />

4 Mbyte RAM, 2 backup batteries,<br />

CP 443-1 communications<br />

module for connection to Industrial<br />

Ethernet plant bus<br />

PS 407 power supply; 10 A for<br />

120/230 V AC, redundant design<br />

possible, with subrack<br />

- UR1 (18 slots) 6ES7 654-2SA34-0XX0<br />

- UR2 (9 slots) 6ES7 654-2SB34-0XX0<br />

- UR2-H (2 x 9 slots) 6ES7 654-2SR34-0XX0<br />

PS 405 power supply; 10 A for<br />

24 V DC, with subrack<br />

- UR1 (18 slots) 6ES7 654-5SA34-0XX0<br />

- UR2 (9 slots) 6ES7 654-5SB34-0XX0<br />

- UR2-H (2 x 9 slots) 6ES7 654-5SR34-0XX0<br />

AS 417-4-2H<br />

<strong>Automation</strong> <strong>System</strong><br />

Complete fault-tolerant programmable<br />

logic controller with two<br />

CPUs 417-4H<br />

Comprising:<br />

2 x CPU 417-H with each<br />

2 interfaces (MPI/DP <strong>and</strong> DP),<br />

4,000 Kbyte main memory<br />

(2,000 Kbyte available user memory),<br />

2 memory cards 4 Mbyte<br />

RAM, 4 backup batteries,<br />

4 sync modules, 2 sync cables,<br />

2 CP 443-1 communications<br />

modules for connection to Industrial<br />

Ethernet plant bus<br />

PS 407 power supply; 10 A for 6ES7 654-2TR34-0XX0<br />

120/230 V AC, redundant design<br />

possible, with<br />

UR2-H subrack (2 x 9 slots)<br />

PS 405 power supply; 10 A for 6ES7 654-5TR34-0XX0<br />

24 V DC, with UR2-H subrack<br />

(2 x 9 slots)<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

10/7<br />

10


10<br />

<strong>Automation</strong> systems<br />

Fault-tolerant automation systems<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

Individual components of fault-tolerant automation systems<br />

CPU 414-4H<br />

Main memory 768 Kbyte<br />

module occupies 2 slots<br />

6ES7 414-4HJ00-0AB0<br />

CPU 417-4H<br />

Main memory 4,000 Kbyte<br />

module occupies 2 slots<br />

6ES7 417-4HL01-0AB0<br />

Sync Module<br />

For linking the two CPUs 414-4H<br />

or 417-4H;<br />

two modules required per CPU<br />

6ES7 960-1AA00-0XA0 B)<br />

Sync Cable (fiberoptic cable)<br />

For connecting the two<br />

CPUs 414-4H or 417-4H;<br />

each redundant automation systems<br />

requires 2 cables<br />

1 m 6ES7 960-1AA00-5AA0<br />

2 m 6ES7 960-1AA00-5BA0<br />

10 m 6ES7 960-1AA00-5KA0<br />

Other lengths On request<br />

RAM Expansion for CPU 417-4H<br />

Main Memory RAM<br />

(only for CPU 417-x; 2 can be<br />

plugged in each)<br />

4 (2 x 2) Mbyte 6ES7 955-2AL00-0AA0<br />

8 (2 x 4) Mbyte 6ES7 955-2AM00-0AA0<br />

Memory Card RAM<br />

1 Mbyte 6ES7 952-1AK00-0AA0<br />

2 Mbyte 6ES7 952-1AL00-0AA0<br />

4 Mbyte 6ES7 952-1AM00-0AA0<br />

8 Mbyte 6ES7 952-1AP00-0AA0<br />

16 Mbyte 6ES7 952-1AS00-0AA0 B)<br />

Memory Card Flash-EPROM<br />

Only required to update firmware<br />

4 Mbyte 6ES7 952-1KM00-0AA0<br />

CP 443-1<br />

6GK7 443-1EX11-0XE0<br />

Communications module for connection<br />

of SIMATIC S7-400 to<br />

Industrial Ethernet through TCP/IP<br />

<strong>and</strong> ISO; for S7 communication,<br />

S5-compatible communication<br />

(SEND/RECEIVE) with<br />

FETCH/WRITE with or without<br />

RFC 1006, 10/100 Mbit/s,<br />

with AUI/ITP <strong>and</strong> RJ45 connections,<br />

electronic manual on CD;<br />

module occupies 1 slot<br />

CP 443-5 Extended<br />

6GK7 443-5DX03-0XE0<br />

Communications module for connection<br />

of SIMATIC S7-400 to<br />

PROFIBUS as DP master or for S7<br />

communication, for increasing the<br />

number of DP lines, for data set<br />

routing with SIMATIC PDM <strong>and</strong> for<br />

10-ms time stamp,<br />

electronic manual on CD;<br />

module occupies 1 slot<br />

10/8<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

PS 407 power supply module 6ES7 407-0KR00-0AA0<br />

for redundant use; 10 A<br />

120/230 V AC; 5 V DC/10 A,<br />

24 V DC/1 A; with battery compartment<br />

for 2 backup batteries,<br />

module occupies 2 slots<br />

PS 405 power supply module; 6ES7 405-0KA01-0AA0<br />

10 A<br />

24 V DC; 5 V DC/10 A,<br />

24 V DC/1 A; with battery compartment<br />

for 2 backup batteries,<br />

module occupies 2 slots<br />

Backup Battery<br />

6ES7 971-0BA00<br />

Type AA, 1.9 Ah<br />

UR1 Subrack<br />

6ES7 400-1TA01-0AA0<br />

18 slots<br />

UR2 Subrack<br />

6ES7 400-1JA01-0AA0<br />

9 slots<br />

UR2-H Subrack<br />

6ES7 400-2JA00-0AA0<br />

For divided central controllers;<br />

2 x 9 slots<br />

Runtime licenses for libraries<br />

PCS 7 Library Blocks V6.0 6ES7 653-2BG06-2YB0<br />

runtime license<br />

valid for one SIMATIC PCS 7 automation<br />

system<br />

trilingual (German, English,<br />

French)<br />

Type of delivery: Certificate of<br />

license<br />

<strong>Engineering</strong><br />

(see the section "<strong>Engineering</strong> system")<br />

In the case of engineering systems with st<strong>and</strong>ard engineering software<br />

SIMATIC PCS 7 V6.0 up to ServicePack 2 you must install the S7-400H<br />

option package in order to be able to configure automation systems with<br />

H architecture (H/F/FH systems). With Service Pack 3 <strong>and</strong> higher, the<br />

functionality of the S7-400H option package is already integrated in the<br />

st<strong>and</strong>ard engineering software.<br />

S7-400H V5.2 Option Package 6ES7 833-2AC01-0YB0<br />

For STEP 7 <strong>and</strong> SIMATIC PCS 7<br />

Only for engineering systems with<br />

st<strong>and</strong>ard engineering software<br />

SIMATIC PCS 7 V6.0 up to Service<br />

Pack 2<br />

Type of delivery:<br />

Certificate of license <strong>and</strong> authorization<br />

diskette<br />

Y-link<br />

Y-link<br />

6ES7 197-1LA02-0XA0<br />

For connection of devices with<br />

only one PROFIBUS DP interface<br />

to a fault-tolerant automation system<br />

B) Subject to export regulations: AL: N, ECCN: EAR99H<br />

■ Options<br />

Y-link<br />

Bus coupler for transition from a redundant PROFIBUS DP<br />

master system to a single-channel PROFIBUS DP master system<br />

For connecting devices with only one PROFIBUS DP interface<br />

to the redundant PROFIBUS DP master system AS 414H/<br />

AS 417H<br />

Detailed information on Y-link can be found at "Communication /<br />

PROFIBUS DP“


■ Overview<br />

Failsafe automation systems (F/FH systems) are used for critical<br />

applications in which an incident can result in danger to persons,<br />

plant damage or environmental pollution. They detect not<br />

only errors in the process but also their own internal errors, <strong>and</strong><br />

will automatically set the plant to a safe state if an error is detected.<br />

The failsafe automation systems (F/FH systems) based on<br />

AS 414H <strong>and</strong> AS 417H combine st<strong>and</strong>ard factory automation<br />

<strong>and</strong> safety engineering in a single system. They are certified by<br />

TÜV (German Technical Inspectorate) <strong>and</strong> comply with safety requirements<br />

class SIL 1 to SIL 3 according to IEC 61508, requirements<br />

class AK 1 to AK 6 according to DIN V 19250/DIN V<br />

VDE 0801, <strong>and</strong> category 2 to 4 according to EN 954-1.<br />

The safety function configured by the user in CFC is executed<br />

twice in various parts of the processor by means of redundant,<br />

diversified comm<strong>and</strong> processing. Potential errors are then detected<br />

in the subsequent comparison of results.<br />

■ Design<br />

The failsafe automation systems are based on the hardware of<br />

the fault-tolerant systems. The picture shows the various packaging<br />

options for failsafe systems, all of which comply with<br />

safety class SIL 3 (IEC 61508) or AK 6 (VDE 0801).<br />

<strong>Automation</strong> systems<br />

Failsafe automation systems<br />

Failsafe automation systems can be designed as single-channel<br />

systems (F systems with a CPU) <strong>and</strong> redundant systems<br />

(FH systems).<br />

The redundancy of FH systems is not relevant for failsafety. It is<br />

not used for error detection, but serves only to increase the availability<br />

of failsafe automation systems.<br />

■ Benefits<br />

7 Use of SIMATIC S7 st<strong>and</strong>ard components for failsafe applications<br />

7 Safety levels SIL 3, AK 6 can be achieved with just one CPU<br />

7 Safe monitoring of communication through PROFIBUS with<br />

PROFIsafe<br />

7 Safe communication through Industrial Ethernet plant bus<br />

7 St<strong>and</strong>ard (S) <strong>and</strong> failsafe (F) functions can be mixed in the<br />

same automation system<br />

7 S <strong>and</strong> F I/Os can be operated on the same PROFIBUS DP line<br />

7 Configuration of S <strong>and</strong> F functions using a common engineering<br />

tool - CFC<br />

7 F-Tool (S7 F <strong>System</strong>s) provides support for the TÜV acceptance:<br />

– separation of S <strong>and</strong> F functions<br />

– checksum by means of application program<br />

– comparison function<br />

– access to F functions is password protected<br />

7 Reduction of engineering costs through simple data exchange<br />

between st<strong>and</strong>ard <strong>and</strong> failsafe systems<br />

7 Minimum training requirements since same tools are used for<br />

st<strong>and</strong>ard <strong>and</strong> failsafe systems<br />

7 Simple fault analysis since same operation <strong>and</strong> monitoring for<br />

st<strong>and</strong>ard <strong>and</strong> failsafe systems (message sequence)<br />

7 Low hardware costs through mixed configurations; optimum<br />

for small applications<br />

7 Minimization of life cycle costs<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

10/9<br />

10


10<br />

<strong>Automation</strong> systems<br />

Failsafe automation systems<br />

■ Function<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

Safety functions<br />

F-Runtime License<br />

6ES7 833-1CC00-6YX0<br />

The safety functions of the F/FH systems are present in the F program<br />

of the CPU <strong>and</strong> in the failsafe ET 200 I/O modules. The<br />

PROFIsafe profile is used for the safety-oriented PROFIBUS DP<br />

For processing failsafe application<br />

programs, for one<br />

AS 414F/FH or AS 417F/FH system<br />

communication between CPU <strong>and</strong> process I/Os. Using this additional<br />

safety message, F/FH systems <strong>and</strong> F I/O modules can<br />

recognize corrupt data <strong>and</strong> can initiate appropriate error re-<br />

AS 414F/FH <strong>and</strong> AS 417F/FH <strong>Engineering</strong><br />

see chapter "<strong>Engineering</strong> system")<br />

sponses.<br />

S7 F <strong>System</strong>s V5.2<br />

6ES7 833-1CC00-0YX0<br />

St<strong>and</strong>ard modules as well as failsafe I/Os can be used in F/FH<br />

systems. A plant consisting of safety-oriented <strong>and</strong> st<strong>and</strong>ard areas<br />

can thus be automated with one <strong>and</strong> the same system <strong>and</strong><br />

be configured with uniform st<strong>and</strong>ard tools.<br />

F programming tool<br />

with F block library for programming<br />

failsafe user programs on<br />

the engineering system, comprising<br />

F program software <strong>and</strong> func-<br />

Integrated in the SIMATIC Manager is the F-Tool (S7 F systems).<br />

tion block library, single license<br />

This engineering tool enables the parameterization of the CPU Bilingual (German, English)<br />

<strong>and</strong> the F signal modules as well as the generation of failsafe ap- Type of delivery:<br />

plications in the CFC based on predefined, TÜV-approved Certificate of license, software<br />

blocks. The failsafe blocks are extremely robust <strong>and</strong> intercept<br />

programming errors such as division by zero or out-of-range val-<br />

<strong>and</strong> electronic documentation on<br />

CD<br />

ues. They save the user having to perform diverse programming<br />

tasks for detecting <strong>and</strong> reacting to errors. Functions such as the<br />

In the case of engineering systems with st<strong>and</strong>ard engineering software<br />

SIMATIC PCS 7 V6.0 up to ServicePack 2 you must install the S7-400H<br />

comparison of F programs, the detection of changes in F pro- option package in order to be able to configure automation systems with<br />

gramming using a checksum, or access privileges using passwords<br />

provide further support <strong>and</strong> guarantee simple, safe operation.<br />

H architecture (H/F/FH systems). With Service Pack 3 <strong>and</strong> higher, the<br />

functionality of the S7-400H option package is already integrated in the<br />

st<strong>and</strong>ard engineering software.<br />

The application program may contain failsafe (F) <strong>and</strong> non-failsafe<br />

st<strong>and</strong>ard programs (S), where strict separation of F <strong>and</strong> S<br />

program components together with data exchange by means<br />

special conversion blocks prevent conflicts. An error detected in<br />

the F program does not result in stopping of the CPU, but leads<br />

to triggering of configurable shutdown logic which sets either the<br />

affected F sequence group or the entire F program to a safe<br />

state. The st<strong>and</strong>ard program continues to run as normal <strong>and</strong> can<br />

trigger reactions as required. After the fault is eliminated, the<br />

F program can be started again with the CPU still running.<br />

S7-400H V5.2 Option Package<br />

For STEP 7 <strong>and</strong> SIMATIC PCS 7<br />

Only for engineering systems with<br />

st<strong>and</strong>ard engineering software<br />

SIMATIC PCS 7 V6.0 up to Service<br />

Pack 2<br />

Type of delivery:<br />

Certificate of license <strong>and</strong> authorization<br />

diskette<br />

6ES7 833-2AC01-0YB0<br />

10/10<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

■ Options<br />

Order information<br />

An AS 414H or AS 417H automation system is required as hardware<br />

for a failsafe AS 414F or AS 417F automation system.<br />

Following H systems can be used, depending on the type <strong>and</strong><br />

design of the failsafe automation system:<br />

For failsafe systems (F systems): one AS 414-1H or AS 417-1H<br />

each<br />

For failsafe <strong>and</strong> system, fault-tolerant systems (FH systems),<br />

- the two subsystems on one subrack: one AS 414-2H or<br />

AS 417-2H each<br />

- the two subsystems on separate racks: two AS 414-1H or<br />

AS 417-1H each<br />

The following components are required in addition:<br />

F-Tool (S7 F <strong>System</strong>s)<br />

F programming tool with F block library for programming failsafe<br />

application programs on the engineering system (see the<br />

chapter "<strong>Engineering</strong> system")<br />

F-Runtime license<br />

for processing failsafe application programs,<br />

for one AS 414F/FH or AS 417F/FH system


Process I/O<br />

11/2 Introduction<br />

11/3 Centralized I/O<br />

11/3 Central I/O modules<br />

11/4 Expansion devices for central I/Os<br />

11/5 ET 200M distributed I/O<br />

11/5 Introduction<br />

11/6 Power supply<br />

11/6 Interface module<br />

11/7 Accessories<br />

11/8 Bundles<br />

11/9 DI - digital input modules<br />

11/11 DO - digital output modules<br />

11/13 AI - analog input modules<br />

11/14 AO - analog output modules<br />

11/15 Ex modules [EEi xb]<br />

11/16 Ex modules with HART<br />

11/17 F modules<br />

11/19 Controller modules<br />

11/20 Controller modules<br />

11/20 Counter modules<br />

11/21 ET 200iS distributed I/O<br />

11/21 Introduction<br />

11/21 Stainless steel wall housing<br />

11/22 Electronic modules<br />

11/23 Power supply <strong>and</strong> interface modules<br />

11/24 ET 200S distributed I/O<br />

11/24 Introduction<br />

11/26 Terminal modules<br />

11/28 Interface modules<br />

11/28 Power modules<br />

11/29 Digital electronic modules<br />

11/30 Analog electronic modules<br />

11/31 Motor starters<br />

11/33 SIGUARD safety engineering<br />

<strong>Siemens</strong> ST PCS 7 · October 2004


11<br />

Process I/O<br />

Introduction<br />

■ Overview<br />

■ Design<br />

The SIMATIC PCS 7 process control system offers various options<br />

for connecting I/O devices <strong>and</strong> for detecting <strong>and</strong> emitting<br />

process signals through sensors <strong>and</strong> actuators:<br />

analog <strong>and</strong> digital I/O modules of the SIMATIC S7-400 operated<br />

centrally in the automation systems<br />

distributed ET 200M, ET 200S <strong>and</strong> ET 200iS with an extensive<br />

range of cost-effective signal <strong>and</strong> function modules, connected<br />

through PROFIBUS DP to the automation system (AS)<br />

direct AS connection of intelligent, distributed field/process<br />

devices <strong>and</strong> operator terminals through PROFIBUS DP/PA (redundant<br />

or in hazard zones 0, 1 or 2 also possible)<br />

Signal groups of the SIMATIC S7-400 can be operated centrally<br />

in the automation system <strong>and</strong> are mainly used in small applications<br />

or systems of limited distributed expansion.<br />

Characteristics such as<br />

modularity <strong>and</strong> consistency,<br />

flexible adaptability to the plant structure,<br />

minimum cabling <strong>and</strong> engineering requirements,<br />

low commissioning, service <strong>and</strong> life cycle costs <strong>and</strong> a<br />

wide range of technical options<br />

Integration of I/O modules in hazardous areas<br />

are the main reasons why distributed process peripherals are<br />

now predominant: ET 200 remote I/Os in conjunction with classic<br />

field/process devices <strong>and</strong> HART field devices or intelligent<br />

The picture shows the various possibilities for integrating I/O<br />

modules in hazardous areas:<br />

field/process devices directly on PROFIBUS.<br />

Ex I/O modules from the ET 200M spectrum<br />

■ Function<br />

The ET 200M can be run in Ex zone 2. The actuators/sensors<br />

can be positioned in Ex zone 1 when suitable Ex I/O modules are<br />

Possible online modifications among the process I/Os<br />

used. The hot swapping of I/O modules within Ex zone 2 is allowed<br />

with the right permit (e.g. fire certificate). FM approvals:<br />

ET 200M Adding/removing ET 200M stations<br />

Class I, Division 2 <strong>and</strong> Class I, Zone 2.<br />

ET 200S, ET 200iS<br />

Adding/removing new I/O modules<br />

Parameterization of I/O modules<br />

Parameterization of connected HART field devices<br />

through SIMATIC PDM<br />

Adding/removing ET 200S/iS stations<br />

Field devices with PROFIBUS PA capability<br />

Using PROFIBUS it is possible to integrate field/process devices<br />

directly in Ex zone 1 or 2, <strong>and</strong> sensors/actuators can also be integrated<br />

in zone 0. FM approvals: Class I, Division 1 <strong>and</strong> Class<br />

I, Zone 0.<br />

ET 200iS: Parameterization of I/O modules, as<br />

well as HART field devices connected to HART Integration of actuators/sensors using ET 200iS<br />

modules, through SIMATIC PDM<br />

ET 200iS can be installed directly in Ex zone 1 or 2<br />

PROFIBUS DP, Adding/removing PROFIBUS DP stations<br />

(EEx de ib [ia/ib] IIC T4), <strong>and</strong> the sensors/actuators can also be<br />

PROFIBUS PA Adding/removing DP/PA links <strong>and</strong> field devices<br />

Parameterization of field devices with<br />

SIMATIC PDM<br />

installed in zone 0 if required. FM approvals: Class I, Division 2<br />

<strong>and</strong> Class I, Zone 1.<br />

11/2<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

An intrinsically safe PC operator control unit can be used in hazardous<br />

areas, zone 1 or 2, if required. For further details of this<br />

operator control unit, see the catalog "Add Ons for the SIMATIC<br />

PCS 7 Process Control <strong>System</strong>“.


Process I/O<br />

Centralized I/O<br />

Central I/O modules<br />

■ Overview<br />

■ Selection <strong>and</strong> Ordering Data<br />

SM 421 Digital Input Modules<br />

Order No.<br />

32 inputs, 24 V DC 6ES7 421-1BL01-0AA0<br />

32 inputs, 120 V AC/DC 6ES7 421-1EL00-0AA0<br />

16 inputs, 24 V DC,<br />

with process/diagnostics interrupt<br />

6ES7 421-7BH01-0AB0<br />

16 inputs, 24 to 60 V AC/DC,<br />

with process/diagnostics interrupt<br />

6ES7 421-7DH00-0AB0<br />

16 inputs, 120/230 V AC/DC, inputs<br />

according to IEC 1131-2<br />

Type 2<br />

SM 422 Digital Output Modules<br />

6ES7 421-1FH20-0AA0<br />

32 outputs; 24 V DC, 0.5 A 6ES7 422-1BL00-0AA0<br />

32 outputs, 24 V DC, 0.5 A;<br />

with diagnostics<br />

6ES7 422-7BL00-0AB0<br />

If required, signal modules from the SIMATIC S7-400 range can<br />

be used in the SIMATIC PCS 7 automation system. These mod-<br />

16 outputs, 24 V DC; 2 A<br />

16 outputs; relay contacts<br />

6ES7 422-1BH11-0AA0<br />

6ES7 422-1HH00-0AA0<br />

ules are an alternative to distributed I/Os particularly for small 16 outputs, 120/230 V AC; 2 A 6ES7 422-1FH00-0AA0<br />

applications or plants with limited distributed expansion.<br />

SM 431 Analog Input Modules<br />

The I/O modules listed in the order data from the S7-400 signal<br />

module range were selected for SIMATIC PCS 7.<br />

16 inputs, non-floating, 13 bit<br />

8 inputs, floating, 13 bit<br />

6ES7 431-0HH00-0AB0<br />

6ES7 431-1KF00-0AB0<br />

8 inputs, floating, 14 bit, with lin- 6ES7 431-1KF10-0AB0<br />

Notes:<br />

earization (RTD/ TC)<br />

Apart from these selected modules it is also possible to use -<br />

8 inputs, floating, 14 bit 6ES7 431-1KF20-0AB0<br />

with limitations in functions - all other I/O modules from the cur- 16 inputs, floating, 16 bit; pro- 6ES7 431-7QH00-0AB0<br />

rent S7-400 signal module range.<br />

cess interrupt capability, with di-<br />

All the process data from the I/Os is available for PCS 7 engineering<br />

in the CFC <strong>and</strong> can be graphically linked to the signal<br />

names from the signal list. The diagnostics information is generated<br />

automatically when using the I/O modules listed below.<br />

agnostics interrupt<br />

8 inputs, floating, 16 bit; process<br />

interrupt capability, for thermocouples,<br />

with diagnostics interrupt<br />

6ES7 431-7KF00-0AB0 B)<br />

Integration in SIMATIC PCS 7 is limited to the process data when<br />

using other I/O components, i.e. the full range of diagnostics<br />

8 inputs, floating, 16 bit; process<br />

interrupt capability, for thermal<br />

6ES7 431-7KF10-0AB0 B)<br />

functions is not automatically available. These modules can resistors, with diagnostics inter-<br />

therefore only be used meaningfully in SIMATIC PCS 7 if it is perruptmissible to omit the diagnostics functions.<br />

SM 432 analog output modules<br />

Online modifications <strong>and</strong> redundancy are not supported by the<br />

central I/O modules.<br />

8 outputs, floating, 13 bit; for<br />

±10 V, 0 to 10 V,<br />

6ES7 432-1HF00-0AB0<br />

1 to 5 V, ± 20 mA, 0 to 20 mA,<br />

■ Technical specifications<br />

4to20 mA<br />

Front Connector (1 pc)<br />

Detailed technical data of the S7-400 modules can be found<br />

in the ST 70 catalog or<br />

in the Mall / CA 01 at "Industry automation systems / Controls /<br />

SIMATIC S7“<br />

With screw contacts<br />

With spring clamps<br />

With crimp contacts<br />

6ES7 492-1AL00-0AA0<br />

6ES7 492-1BL00-0AA0<br />

6ES7 492-1CL00-0AA0<br />

B) Subject to export regulations: AL: N, ECCN: EAR99H<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

11/3<br />

11


11<br />

Process I/O<br />

Centralized I/O<br />

Expansion devices for central I/Os<br />

■ Overview<br />

Expansion devices can be used for the distributed expansion of<br />

the SIMATIC S7-400. The IM 460-x interface modules are used<br />

as the interface for these expansion devices.<br />

Restriction compared to st<strong>and</strong>ard I/O modules from the<br />

ET 200M range<br />

no redundant connection of the expansion devices<br />

no configuration during operation<br />

Subracks<br />

The universal racks (UR modules) are used for SIMATIC PCS 7.<br />

They can be used as central racks <strong>and</strong> as expansion racks.<br />

Other module racks, see Catalog ST 70.<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

IM 460-0 Interface Module 6ES7 460-0AA01-0AB0<br />

Transmitting module for central<br />

device<br />

Without transmission of voltage<br />

to the expansion device<br />

Cable up to 5 m long<br />

With K-Bus for communication<br />

with CPs <strong>and</strong> FMs in the expansion<br />

device<br />

For connecting as many as 8 expansion<br />

devices<br />

IM 461-0 Interface Module 6ES7 461-0AA01-0AA0<br />

Corresponding receiving module<br />

for the expansion device<br />

IM 460-1 Interface Module 6ES7 460-1BA01-0AB0<br />

Transmitting module for central<br />

device<br />

With transmission of the 5 V voltage<br />

supply for I/O modules<br />

Cable up to 1.5 m long<br />

Without transmission of the K-<br />

Bus, hence solely for communication<br />

from I/O modules<br />

IM 461-1 Interface Module 6ES7 461-1BA01-0AA0<br />

Corresponding receiving module<br />

for the expansion device<br />

11/4<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

6ES7 460-3AA01-0AB0<br />

IM 460-3 Interface Module<br />

Transmitting module for central<br />

device<br />

Without transmission of voltage<br />

to the expansion device<br />

Cable up to 100 m long<br />

With K-Bus for communication<br />

with CPs <strong>and</strong> FMs in the expansion<br />

device<br />

For connecting as many as 8 expansion<br />

devices<br />

IM 461-3 Interface Module<br />

Corresponding receiving module<br />

for the expansion device<br />

UR1 Subrack<br />

for central <strong>and</strong> expansion devices<br />

18 slots<br />

suitable for redundant power<br />

supply<br />

UR2 Subrack<br />

for central <strong>and</strong> expansion devices<br />

9 slots<br />

suitable for redundant power<br />

supply<br />

6ES7 461-3AA01-0AA0<br />

6ES7 400-1TA01-0AA0<br />

6ES7 400-1JA01-0AA0<br />

■ Accessories Order No.<br />

468-1 Connecting Cable<br />

for connecting IM 460-0 <strong>and</strong><br />

IM 461-0; IM 460-3 <strong>and</strong> IM 461-3<br />

0.75 m 6ES7 468-1AH50-0AA0<br />

1.5 m 6ES7 468-1BB50-0AA0<br />

5 m 6ES7 468-1BF00-0AA0<br />

additional lengths for connecting<br />

IM 460-3 <strong>and</strong> IM 461-3<br />

10 m 6ES7 468-1CB00-0AA0<br />

25 m 6ES7 468-1CC50-0AA0<br />

50 m 6ES7 468-1CF00-0AA0<br />

100 m 6ES7 468-1DB00-0AA0<br />

Terminating Connector<br />

6ES7 461-0AA00-7AA0<br />

for IM 461-0<br />

468-3 Connecting Cable<br />

for connecting IM 460-1 <strong>and</strong><br />

IM 461-1<br />

0.75 m 6ES7 468-3AH50-0AA0<br />

1.5 m 6ES7 468-3BB50-0AA0


■ Overview<br />

The ET 200M distributed I/O stations are the line of choice from<br />

the ET 200 family for process control applications with SIMATIC<br />

PCS 7.<br />

The ET 200M line contains a diversified selection of I/O modules<br />

in S7-300 design, some with special control functions:<br />

St<strong>and</strong>ard-S7-300 signal modules<br />

Redundant S7-300 signal modules (DI 16 x 24 V DC, with diagnostics;<br />

DO 32 x 24 V DC/0.5 A; AI 8 x 12 Bit)<br />

I & C modules with enhanced diagnostics capability<br />

Ex I/O modules<br />

Controller <strong>and</strong> counter modules<br />

HART modules<br />

F modules for failsafe applications<br />

When active bus modules are used, defective I/O modules can<br />

be replaced during operation of the plant without neighboring<br />

modules being affected (hot swapping function).<br />

Following actions are possible in RUN mode of the automation<br />

system:<br />

adding new modules within a station<br />

reparameterization of modules<br />

adding ET 200M stations<br />

The connected HART field devices can be parameterized<br />

through SIMATIC PDM.<br />

Note :<br />

Apart from these selected modules it is also possible to use -<br />

with limitations in functions - all other I/O modules from the current<br />

S7-300 signal module range.<br />

Process I/O<br />

ET 200M distributed I/O<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

Introduction<br />

■ Design<br />

The ET 200M distributed I/O station consists of<br />

1 or 2 (redundant) power supply modules,<br />

1 or 2 (redundant) IM 153 interface modules for connecting<br />

through PROFIBUS DP with data transfer rates up to 12 Mbit/s<br />

up to 8 I/O modules for connecting the sensor/actuator technology<br />

All I/O modules are optically isolated from the backplane bus.<br />

Up to 8 I/O modules can be connected to one interface module.<br />

The interface modules can be also be configured for a redundant<br />

architecture if required.<br />

In addition to the SIMATIC S7 st<strong>and</strong>ard input/output modules<br />

there are special IC I/O modules whose functions include the following:<br />

channel-specific diagnostics, e.g. wire break, short-circuit,<br />

overflow/underflow values<br />

internal module monitoring, e.g. parameterizaiton error, RAM<br />

error, fuse drop<br />

chatter monitoring for transducers<br />

pulse extension<br />

output of a parameterizable substitute value when the CPU<br />

fails<br />

The modules with diagnostics capability automatically send the<br />

corresponding signal to the operator system when a fault occurs,<br />

enabling the problem to be solved quickly <strong>and</strong> easily.<br />

The ET 200M can be run in st<strong>and</strong>ard environments or in Ex zone<br />

2. The actuators/sensors can be positioned in Ex zone 1 when<br />

suitable Ex I/O modules are used. The hot swapping of I/O modules<br />

within Ex zone 2 is allowed with the right permit (e.g. fire certificate).<br />

■ Technical specifications<br />

Detailed technical data on ET 200M <strong>and</strong> S7-300 signal modules<br />

can be found<br />

in the ST 70 catalog or<br />

in the Mall / CA 01 at "Industry automation systems / Controls<br />

/ SIMATIC S7“<br />

11/5<br />

11


11<br />

Process I/O<br />

ET 200M distributed I/O<br />

Power supply<br />

■ Overview<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

The PS 307 or PS 305 load power supply is used to supply power PS 307 Load Power Supply<br />

to the ET 200M. There is a choice of input voltages <strong>and</strong> output Including connection assembly;<br />

currents (AC 120/230 V with 2 A, 5 A or 10 A, or DC 24...110 V<br />

with 2 A) to suit the field of application.<br />

120/230 V AC; 24 V DC<br />

- 2 A; 50 mm wide 6ES7 307-1BA00-0AA0<br />

- 5 A; 80 mm wide 6ES7 307-1EA00-0AA0<br />

- 5 A, extended temperature<br />

range; 80 mm wide<br />

6ES7 307-1EA80-0AA0<br />

- 10A, 200mm wide<br />

PS 305 Load Power Supply<br />

Including connection assembly;<br />

24/48/60/110 V DC; 24 V DC<br />

6ES7 307-1KA01-0AA0<br />

- 2 A, extended temperature<br />

range; 80 mm wide<br />

6ES7 305-1BA80-0AA0<br />

Interface module<br />

■ Overview<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

An IM 153-2 High Feature interface module is needed to connect IM 153-2 High Feature<br />

6ES7 153-2BA00-0XB0 B)<br />

the ET 200M to the PROFIBUS DP field bus. It supports the fol- Slave interface module for conlowing<br />

functions:<br />

nection of an ET 200M to<br />

7 HART configuring of intelligent field devices,<br />

PROFIBUS DP, with time stamp<br />

(accuracy 5 ms), support of<br />

7 configuration of ET 200M I/Os in RUN mode of the automation HART functionality, F modules,<br />

system,<br />

7 connection to redundant AS 414H / AS 417H automation systems,<br />

7 use of ET 200M function modules (controller <strong>and</strong> counter modules).<br />

FM modules, "Configuration in<br />

RUN" function; also for use in<br />

redundant systems<br />

IM 153-2 FO High Feature<br />

Slave interface module for connection<br />

of an ET 200M to optical<br />

6ES7 153-2BB00-0XB0 B)<br />

This interface module is also available in a fiberoptic (FO) version<br />

for connecting to an optical PROFIBUS.<br />

PROFIBUS DP; support of HART<br />

functionality, F modules, FM modules,<br />

"Configuration in RUN" function;<br />

also for use in redundant<br />

systems<br />

Notes:<br />

Plastic fiberoptic cables <strong>and</strong> a mounting set for simplex connectors<br />

are required for use of the IM 153-2 FO (see "Plastic fiberoptic<br />

cables&#147; in the section "Communication/PROFI-<br />

BUS&#147;)<br />

The active bus modules <strong>and</strong> the profile rail for hot swapping are<br />

required in order to be able to use the hot swapping function.<br />

B) Subject to export regulations: AL: N, ECCN: EAR99H<br />

11/6<br />

<strong>Siemens</strong> ST PCS 7 · October 2004


The picture shows the various bus modules being used for hot<br />

swapping. Top: for redundant connection, Bottom: for singular<br />

connection.<br />

Process I/O<br />

ET 200M distributed I/O<br />

■ Overview<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

Following components are available as accessories for the Bus Modules for Hot Swapping<br />

ET 200M:<br />

BM PS/IM for power supply <strong>and</strong> 6ES7 195-7HA00-0XA0<br />

Bus modules for hot swapping<br />

Profile rails for hot swapping<br />

Covers for bus backplanes <strong>and</strong> bus modules<br />

IM 153,<br />

incl. 1 bus module cover<br />

BM 2x40 for 2 modules, each<br />

40 mm wide<br />

6ES7 195-7HB00-0XA0<br />

Front connectors<br />

BM 1x80 for 1 module, 80 mm 6ES7 195-7HC00-0XA0<br />

Ex partition for ET 200M<br />

wide<br />

LK 393 cable duct<br />

IM 153/IM 153<br />

for two IM 153-2/-2 FOs for design<br />

of redundant systems<br />

6ES7 195-7HD10-0XA0<br />

Ex partition<br />

Profile Rail for Hot Swapping<br />

A mechanical isolation is required between the IM 153 interface 482 mm long (19 inches) 6ES7 195-1GA00-0XA0<br />

module <strong>and</strong> the first Ex I/O module. For the hot swapping function,<br />

an Ex partition is installed which guarantees the prescribed<br />

isolation distance between non-intrinsically-safe <strong>and</strong> intrinsi-<br />

530 mm long<br />

630 mm long<br />

6ES7 195-1GF30-0XA0<br />

6ES7 195-1GG30-0XA0<br />

cally-safe areas of the ET 200M distributed I/O system.<br />

Covers<br />

6ES7 195-1JA00-0XA0<br />

LK 393 cable duct<br />

Pack with 4 backplane bus covers<br />

<strong>and</strong> 1 bus module cover<br />

The LK 393 cable duct guarantees the prescribed isolation between<br />

the load voltage input <strong>and</strong> the intrinsically safe inputs/outputs.<br />

The cable duct is easy to fit following insertion of the load<br />

Front Connector (1 pcs)<br />

20-pin, with screw contacts 6ES7 392-1AJ00-0AA0<br />

voltage inputs L+.<br />

20-pin, with spring contacts 6ES7 392-1BJ00-0AA0<br />

■ Design<br />

40-pin, with screw contacts<br />

40-pin, with spring contacts<br />

6ES7 392-1AM00-0AA0<br />

6ES7 392-1BM01-0AA0<br />

Front connector for Ex analog<br />

input module 6ES7 331-7SF00-<br />

0AB0 (1 pcs)<br />

20-pin, with screw contacts<br />

enables an accuracy of ± 1.5 K<br />

for the internal reference point<br />

temperature when taking thermoelement<br />

temperature measurements<br />

in the measuring mode<br />

"internal compensation" at ambient<br />

temperatures of 0 ... 60 °C<br />

6ES7 392-1AJ20-0AA0<br />

Ex partition for ET 200M<br />

Separation of IM 153 <strong>and</strong> downstream<br />

Ex modules within an<br />

ET 200M line<br />

Mixed operation of non-Ex <strong>and</strong><br />

Ex modules within an ET 200M<br />

line<br />

for supporting the hot swapping<br />

function in connection with<br />

IM 153-2<br />

6ES7 195-1KA00-0XA0<br />

LK 393 cable duct<br />

[EEx ib] IIC-conform routing of<br />

load voltage cable in front plug,<br />

5pcs<br />

6ES7 393-4AA00-0AA0<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

Accessories<br />

11/7<br />

11


11<br />

Process I/O<br />

ET 200M distributed I/O<br />

Bundles<br />

■ Overview<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

Following preassembled bundles are available for ET 200M: I/O Subsystem ZuS<br />

I/O Subsystem ZuS:<br />

ET 200M with hot swapping of modules, comprising<br />

- profile rail for active bus modules,<br />

- PS/IM bus module <strong>and</strong><br />

- IM 153-2 High Feature bus interface module<br />

IM 153 redundancy bundle:<br />

comprising two IM 153-2 High Feature <strong>and</strong> one active<br />

ET 200M with hot swapping of<br />

modules, comprising profile rail<br />

for active bus modules size 482<br />

mm (19 inches), PS/IM bus module<br />

<strong>and</strong><br />

IM 153-2 High Feature bus interface<br />

module<br />

for support of HART functional-<br />

6ES7 654-0XX06-1XA0 B)<br />

IM 153/IM 153 bus module, for operating the ET 200M on the ity, F modules, FM modules,<br />

fault-tolerant AS 414H / AS 417H automation system.<br />

HART bundle with Ex analog input modules for redundant<br />

PROFIBUS connection,<br />

for operation in the AS 414H / AS 417H fault-tolerant automa-<br />

Configuration in RUN" function;<br />

also for use in redundant systems<br />

IM 153 Redundancy Bundle 6ES7 153-2AR01-0XA0 B)<br />

tion system, comprising<br />

comprising two IM 153-2 High<br />

- one 482 mm profile rail,<br />

- one IM 153 / IM 153 active bus module,<br />

- four 2x40 bus modules,<br />

- two IM 153-2 High Feature <strong>and</strong><br />

- eight HART-capable Ex analog input modules.<br />

Feature <strong>and</strong> one active<br />

IM 153/IM 153 bus module,<br />

for operating the ET 200M on the<br />

fault-tolerant AS 414H / AS 417H<br />

automation system<br />

HART bundle with Ex AI modules<br />

[EEx ib]<br />

for redundant PROFIBUS connection,<br />

comprising:<br />

two IM 153-2 High Feature interface<br />

modules<br />

8 Ex analog input modules with<br />

HART<br />

one IM 153 / IM 153 bus module<br />

four 2x40 bus modules for<br />

2 modules<br />

one 482 mm profile rail<br />

6ES7 650-0XX06-0XX0 B)<br />

11/8<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

B) Subject to export regulations: AL: N, ECCN: EAR99H


16 inputs, 48...125 V DC,<br />

floating in groups of 8<br />

required front connector: 20-pin<br />

16 inputs, 48...125 V DC,<br />

floating in groups of 8;<br />

temperature range -25...+60 °C<br />

required front connector: 20-pin<br />

6ES7 321-1CH20-0AA0<br />

6AG1 321-1CH20-2AA0 B)<br />

Process I/O<br />

ET 200M distributed I/O<br />

DI - digital input modules<br />

■ Overview<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

The digital input modules described here break down into SM 321 for floating contacts (with DC/AC supply)<br />

simple signal modules for direct <strong>and</strong> alternating voltage, <strong>and</strong><br />

modules with diagnostics capability that send a corresponding<br />

signal to the operator system when a fault occurs.<br />

16 inputs, 24...48 V AC/DC, 6ES7 321-1CH00-0AA0<br />

floating in groups of 1<br />

required front connector: 40-pin<br />

SM 321 for floating contacts (with AC supply)<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

32 inputs, 120 V AC,<br />

floating in groups of 8<br />

6ES7 321-1EL00-0AA0<br />

SM 321 for Floating Contacts (with DC supply)<br />

required front connector: 40-pin<br />

16 inputs, 24 V DC,<br />

floating in groups of 16, redundant<br />

design possible<br />

required front connector: 20-pin<br />

6ES7 321-1BH02-0AA0<br />

8 inputs, 120/230 V AC,<br />

floating in groups of 2, redundant<br />

design possible<br />

required front connector: 20-pin<br />

6ES7 321-1FF01-0AA0<br />

16 inputs, 24 V DC,<br />

floating in groups of 16;<br />

temperature range -25...+60 °C<br />

required front connector: 20-pin<br />

6AG1 321-1BH02-2AA0 B)<br />

8 inputs, 120/230 V AC,<br />

floating in groups of 2;<br />

temperature range -25...+60 °C<br />

required front connector: 20-pin<br />

6AG1 321-1FF01-2AA0 B)<br />

16 inputs, 24 V DC,<br />

floating in groups of 16; m-reading<br />

6ES7 321-1BH50-0AA0<br />

16 inputs, 120/230 V AC,<br />

floating in groups of 4<br />

required front connector: 20-pin<br />

6ES7 321-1FH00-0AA0<br />

required front connector: 20-pin<br />

SM 321 for non-floating contacts (with AC supply)<br />

16 inputs, 24 V DC, High Speed<br />

floating in groups of 16;<br />

0.05 ms input delay<br />

required front connector: 20-pin<br />

32 inputs, 24 V DC,<br />

floating in groups of 16, redundant<br />

design possible<br />

required front connector: 40-pin<br />

32 inputs, 24 V DC,<br />

floating in groups of 16;<br />

6ES7 321-1BH10-0AA0<br />

6ES7 321-1BL00-0AA0<br />

6AG1 321-1BL00-2AA0 B)<br />

8 inputs, 120/230 V AC,<br />

floating in groups of 1<br />

required front connector: 40-pin<br />

SM 323 Digital I/O Module<br />

8 inputs 24 V DC,<br />

8 outputs 24 V DC, 0.5 A;<br />

temperature range -25...+60 °C<br />

required front connector: 20-pin<br />

6ES7 321-1FF10-0AA0<br />

6AG1 323-1BH01-2AA0<br />

B)<br />

B)<br />

temperature range -25...+60 °C<br />

required front connector: 40-pin<br />

B) Subject to export regulations: AL: N, ECCN: EAR99H<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

11/9<br />

11


11<br />

Process I/O<br />

ET 200M distributed I/O<br />

DI - digital input modules<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

SM 321 Modules with Diagnostics Capability (IM 153-2 High Feature<br />

interface module required)<br />

For floating contacts (with DC supply)<br />

16 inputs, 24 V DC<br />

- Floating in groups of 16, redundant<br />

design possible<br />

- Time stamp in connection<br />

with IM 153-2 High Feature,<br />

5 ms accuracy, rising or falling<br />

edge, channelselective<br />

parameterization possible<br />

- Two short-circuit resistant sensor<br />

power supplies, each for<br />

8 channels<br />

- Sensor power supply through<br />

the module; external redundant<br />

sensor power supply also<br />

possible<br />

- Diagnostics of missing sensor<br />

power supply for channel<br />

group (8 channels)<br />

- Diagnostics inside module<br />

- Wire break monitoring<br />

- required front connector:<br />

20-pin<br />

6ES7 321-7BH01-0AB0<br />

16 inputs, 24 V DC<br />

- Data same as 6ES7 321-<br />

7BH01-0AB0,<br />

- <strong>and</strong> temperature range -<br />

25...+60 °C<br />

- required front connector:<br />

20-pin<br />

6AG1 321-7BH01-2AB0 B)<br />

11/10<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

6ES7 321-7TH00-0AB0<br />

16 inputs, NAMUR<br />

- Floating in groups of 8, redundant<br />

design possible<br />

- Time stamp in connection<br />

with IM 153-2 High Feature,<br />

5 ms accuracy, rising or falling<br />

edge, channelselective<br />

parameterization possible<br />

- Two sensor power supplies<br />

(each 8.2 V DC or 18 V DC)<br />

- Connection of NAMUR sensors<br />

or contacts with resistor<br />

circuit<br />

- Pulse extension<br />

- Channel-selective diagnostics<br />

(short circuit, wire break, chatter<br />

monitoring, discrepancy<br />

between changeover contacts)<br />

- Diagnostics inside module<br />

- required front connector:<br />

40-pin<br />

B) Subject to export regulations: AL: N, ECCN: EAR99H


Process I/O<br />

ET 200M distributed I/O<br />

DO - digital output modules<br />

■ Overview<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

The digital output modules described here break down into<br />

simple signal modules for direct <strong>and</strong> alternating voltage with<br />

different output currents per channel, with a selection of relay<br />

modules available for high output currents <strong>and</strong> voltages,<br />

modules with diagnostics capability that supply data for trou-<br />

SM 322 for AC Voltage<br />

(suitable for AC magnet coils, contactors, motor starters, miniature<br />

motors <strong>and</strong> indicator lights)<br />

8 outputs, 120/230 V AC / 2 A, 6ES7 322-1FF01-0AA0<br />

floating in groups of 4, redundant<br />

design possible<br />

bleshooting <strong>and</strong> enable parameterizable reactions to the fail- required front connector: 20-pin<br />

ure of the automation system.<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

16 outputs, 120/230 V AC / 1 A,<br />

floating in groups of 8<br />

required front connector: 20-pin<br />

6ES7 322-1FH00-0AA0<br />

SM 322 for Direct Voltage<br />

(suitable for solenoid valves, contactors, indicator lights etc.)<br />

32 outputs, 120/230 V AC / 1 A,<br />

floating in groups of 8<br />

6ES7 322-1FL00-0AA0<br />

8 outputs, 24 V DC / 2 A,<br />

floating in groups of 4, redun-<br />

6ES7 322-1BF01-0AA0<br />

required front connector:<br />

2x20-pin<br />

dant design possible<br />

required front connector: 20-pin<br />

SM 322 for Relay Output<br />

(suitable for AC/DC solenoid valves, contactors, motor starters,<br />

16 outputs, 24 V DC / 0.5 A, 6ES7 322-1BH01-0AA0<br />

miniature motors <strong>and</strong> indicator lights)<br />

floating in groups of 8<br />

required front connector: 20-pin<br />

8 outputs, 24...120 V DC,<br />

48...230 V AC / max. 2 A,<br />

6ES7 322-1HF01-0AA0<br />

16 outputs, 24 V DC / 0.5 A,<br />

floating in groups of 8;<br />

6AG1 322-1BH01-2AA0 B) floating in groups of 2<br />

required front connector: 20-pin<br />

temperature range -25...+60 °C<br />

required front connector: 20-pin<br />

8 outputs, 24...120 V DC,<br />

48...230 V AC / max. 5 A,<br />

6ES7 322-1HF10-0AA0<br />

16 inputs, 24 V DC / 0.5 A, High<br />

Speed<br />

6ES7 322-1BH10-0AA0<br />

floating in groups of 1<br />

required front connector: 40-pin<br />

floating in groups of 8;<br />

0.2 ms input delay<br />

required front connector: 20-pin<br />

8 outputs, 24...120 V AC,<br />

48...230 V AC, max. 5 A<br />

floating in groups of 1;<br />

6AG1 322-1HF10-2AA0 B)<br />

32 outputs, 24 V DC / 0.5 A,<br />

floating in groups of 8, redun-<br />

6ES7 322-1BL00-0AA0<br />

temperature range -25...+60 °C<br />

required front connector: 40-pin<br />

dant design possible<br />

required front connector: 40-pin<br />

16 outputs, 24...120 V DC,<br />

48...230 V AC / max. 2 A,<br />

6ES7 322-1HH01-0AA0<br />

8 outputs, 48...125 V DC / 1.5 A,<br />

floating in groups of 4<br />

6ES7 322-1CF00-0AA0 B) floating in groups of 8<br />

required front connector: 20-pin<br />

required front connector: 20-pin<br />

SM 323 Digital I/O Module<br />

8 outputs, 48...120 V DC / 1.5 A,<br />

floating in groups of 4;<br />

temperature range -25...+60 °C<br />

required front connector: 20-pin<br />

6AG1 322-1CF00-2AA0 B) 8 inputs 24 V DC,<br />

8 outputs 24 V DC, 0.5 A;<br />

temperature range -25...+60 °C<br />

required front connector: 20-pin<br />

6AG1 323-1BH01-2AA0 B)<br />

B) Subject to export regulations: AL: N, ECCN: EAR99H<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

11/11<br />

11


11<br />

Process I/O<br />

ET 200M distributed I/O<br />

DO - digital output modules<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

SM 322 Modules with Diagnostics Capability (with channel <strong>and</strong><br />

module diagnostics)<br />

For direct voltage<br />

(suitable for solenoid valves, DC contactors <strong>and</strong> indicator lights)<br />

8 outputs, 24 V DC / 0.5 A,<br />

floating in groups of 8, redundant<br />

design possible<br />

- Two connections per output<br />

(with <strong>and</strong> without series diode)<br />

- Connecting a default value by<br />

channel in the event of CPU<br />

stop (parameterizable)<br />

- Broken wire monitoring by<br />

channel<br />

- Monitoring of load voltage per<br />

channel<br />

- Short-circuit monitoring according<br />

to M/L+ per channel<br />

- Diagnostics functions inside<br />

the module<br />

- required front connector:<br />

20-pin<br />

6ES7 322-8BF00-0AB0<br />

8 outputs, 24 V DC / 0.5 A,<br />

floating in groups of 8<br />

- Data same as 6ES7 322-<br />

8BF00-0AB0,<br />

- <strong>and</strong> temperature range<br />

-25...+60 °C<br />

- required front connector:<br />

20-pin<br />

6AG1 322-8BF00-2AB0 B)<br />

16 outputs, 24 V DC / 0.5 A,<br />

floating in groups of 4<br />

- Connecting a default value by<br />

channel in the event of CPU<br />

stop (parameterizable)<br />

- Broken wire monitoring per<br />

channel (with 0 <strong>and</strong> 1 signal)<br />

- Signal when output is overloaded<br />

- Monitoring of load voltage or<br />

ground per channel group<br />

- Short-circuit monitoring according<br />

to M/L+ per channel<br />

- Diagnostics functions inside<br />

the module<br />

- required front connector: 40pin<br />

11/12<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

6ES7 322-8BH01-0AB0<br />

■ Selection <strong>and</strong> Ordering Data<br />

For AC voltage<br />

Order No.<br />

(suitable for AC magnet coils, contactors, motor starters, miniature<br />

motors <strong>and</strong> indicator lights)<br />

8 outputs, 120/230 V AC / 2 A,<br />

floating in groups of 1<br />

- Connecting a default value by<br />

channel in the event of CPU<br />

stop (parameterizable)<br />

- Diagnostics functions inside<br />

the module<br />

required front connector:<br />

40-pin<br />

6ES7 322-5FF00-0AB0 B)<br />

16 outputs, 24/48 V AC/DC /<br />

0.5 A,<br />

floating in groups of 1<br />

- Connecting a default value by<br />

channel in the event of CPU<br />

stop (parameterizable)<br />

- Diagnostics functions inside<br />

the module<br />

- required front connector:<br />

40-pin<br />

For relay output<br />

6ES7 322-5GH00-0AB0 B)<br />

(suitable for AC/DC magnet coils, contactors, motor starters, miniature<br />

motors <strong>and</strong> indicator lights<br />

8 outputs, 24...120 V DC,<br />

24...230 V AC / max. 5 A,<br />

floating in groups of 1<br />

- With RC quenching element<br />

for protecting the contacts per<br />

channel<br />

- Connecting a default value by<br />

channel in the event of CPU<br />

stop (parameterizable)<br />

- Diagnostics functions inside<br />

the module<br />

- required front connector:<br />

40-pin<br />

6ES7 322-5HF00-0AB0 B)<br />

B) Subject to export regulations: AL: N, ECCN: EAR99H


SM 331 Modules for Current/Voltage Measurement <strong>and</strong> Temperature<br />

Measurement<br />

8 inputs, individually parameterizable<br />

- Resolution 12 bit + sign<br />

- Current measurement<br />

0/4...20 mA (8 channels;<br />

2 wires with external supply or<br />

4wires)<br />

- Voltage measurement<br />

(8 channels)<br />

- Resistance thermometer<br />

Pt100, Ni100, Ni1000, LG-<br />

Ni1000 (8 channels; 2, 3 or<br />

4wires)<br />

- required front connector: 40-pin<br />

6ES7 331-1KF01-0AB0<br />

8 inputs in 4 channel groups, redundant<br />

design possible<br />

- Changeover of measurement<br />

type by range module per<br />

channel group<br />

- Resolution 14 bit + sign<br />

- Current measurement<br />

0/4...20 mA (8 channels; 2 or 4<br />

wires)<br />

- Voltage measurement<br />

(8 channels)<br />

- Resistance thermometer<br />

Pt100, Ni100 (4 channels, 2 or<br />

4wires)<br />

- Thermocouples type E, N, J, K,<br />

L (8 channels),<br />

internal compensation or external<br />

compensation with compensating<br />

box or 0 °C<br />

comparison point<br />

- Wire break monitoring<br />

- Redundant design possible<br />

- Diagnostics inside module<br />

- required front connector: 20-pin<br />

6ES7 331-7KF02-0AB0<br />

2 inputs in 1 channel group<br />

- Changeover of measurement<br />

type by range module<br />

- Resolution 14 bit + sign<br />

- Current measurement<br />

0/4...20 mA (2 channels; 2 or 4<br />

wires)<br />

- Voltage measurement<br />

(2 channels)<br />

- Resistance thermometer<br />

Pt100, Ni100 (1 channel, 2 or<br />

4wires)<br />

- Thermocouples type E, N, J, K,<br />

L (2 channels),<br />

internal compensation or external<br />

compensation with compensating<br />

box or 0 °C<br />

comparison point<br />

- Wire break monitoring<br />

- Diagnostics inside module<br />

- required front connector: 20-pin<br />

6ES7 331-7KB02-0AB0 B)<br />

Process I/O<br />

ET 200M distributed I/O<br />

AI - analog input modules<br />

■ Overview<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

The analog input modules described here break down into<br />

multifunction modules for current, voltage <strong>and</strong> temperature<br />

measurement, <strong>and</strong><br />

2 inputs in 1 channel group<br />

- Data same as 6ES7 331-<br />

7KB02-0AB0,<br />

- <strong>and</strong> temperature range<br />

6AG1 331-7KB02-2AB0 B)<br />

special high-precision modules for current/voltage measurement<br />

or temperature measurement.<br />

-25...+60 °C<br />

- required front connector:<br />

20-pin<br />

All modules automatically supply channel-specific <strong>and</strong> moduleinternal<br />

diagnostics data, except module 6ES7 331-1KF00-<br />

0AB0. With the latter module, channel failure is identified by the<br />

PCS 7 analog driver block.<br />

SM 331 Modules for Current <strong>and</strong> Voltage Measurement<br />

8 inputs in 4 channel groups, 6ES7 331-7NF00-0AB0<br />

redundant design possible<br />

- Resolution 15 bit + sign<br />

B)<br />

The individual channels of the analog input modules can be parameterized<br />

in groups independently of each other.<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

- Current measurement<br />

0/4...20 mA (8 channels; 2 or 4<br />

wires)<br />

- Voltage measurement<br />

(8 channels)<br />

- Wire break monitoring<br />

- Diagnostics inside module<br />

- required front connector: 40-pin<br />

8 inputs in 4 channel groups<br />

- Resolution 15 bit + sign<br />

- Fast module cycle (min. 10 ms<br />

for 4 channels)<br />

- Current measurement<br />

0/4...20 mA (8 channels;<br />

2 wires with external supply or<br />

4wires)<br />

- Voltage measurement<br />

(8 channels)<br />

- Wire break monitoring<br />

- Short-circuit-proof<br />

- Isolation between channel<br />

groups<br />

- Diagnostics inside module<br />

- required front connector: 40-pin<br />

6ES7 331-7NF10-0AB0 B)<br />

SM 331 Modules for Temperature Measurement<br />

8 inputs in 4 channel groups<br />

- Resolution 15 bit<br />

- Resistance thermometer<br />

Pt100...1000, Ni100...1000,<br />

Cu10 (8 channels; 2, 3 or<br />

4wires)<br />

- Short-circuit-proof<br />

- Wire break monitoring<br />

- Diagnostics inside module<br />

- required front connector: 40-pin<br />

6ES7 331-7PF00-0AB0 B)<br />

8 inputs in 4 channel groups<br />

- Resolution 15 bit<br />

- Thermocouples type B, C, N,<br />

E, R, S, J, L, T, K, U<br />

(8 channels),<br />

internal compensation; external<br />

compensation with Pt100<br />

through separate inputs possible<br />

- Fast module cycle (10 ms for<br />

4 channels)<br />

- Short-circuit-proof<br />

- Wire break monitoring<br />

- Diagnostics inside module<br />

- required front connector: 40-pin<br />

6ES7 331-7PF10-0AB0 B)<br />

B) Subject to export regulations: AL: N, ECCN: EAR99H<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

11/13<br />

11


11<br />

Process I/O<br />

ET 200M distributed I/O<br />

AO - analog output modules<br />

■ Overview<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

The analog output modules for voltage <strong>and</strong> current described SM 332 Modules for Current <strong>and</strong> Voltage Outputs<br />

here break down into<br />

2 outputs in 2 channel groups 6ES7 332-5HB01-0AB0<br />

modules with 12 bit resolution <strong>and</strong> various numbers of channels,<br />

<strong>and</strong><br />

a high-precision module with 15 bit resolution.<br />

- Resolution 12 bit + sign<br />

- Voltage 0/1...5/10 V; ±10 V<br />

(2 channels; 2 or 4 wires)<br />

- Current 0/4...20 mA; ±20 mA<br />

The analog output modules can be parameterized in groups independently<br />

of each other <strong>and</strong> automatically supply all channelspecific<br />

<strong>and</strong> module-internal diagnostics data.<br />

(2 channels; 2 wires)<br />

- Parameterizable substitute<br />

value output in case of CPU<br />

stop<br />

- Broken wire monitoring (only<br />

for current)<br />

- Short circuit monitoring (only<br />

for voltage)<br />

- Diagnostics inside module<br />

- required front connector: 20-pin<br />

2 outputs in 2 channel groups<br />

- Data same as 6ES7 332-<br />

5HB01-0AB0,<br />

- <strong>and</strong> temperature range<br />

-25...+60 °C<br />

- required front connector: 20-pin<br />

6AG1 332-5HB01-2AB0 B)<br />

4 outputs in 4 channel groups,<br />

redundant design possible<br />

- Resolution 12 bit + sign<br />

- Voltage 0/1...5/10 V; ±10 V<br />

(4 channels; 4 wires)<br />

- Current 0/4...20 mA; ±20 mA<br />

(4 channels; 2 wires)<br />

- Parameterizable substitute<br />

value output in case of CPU<br />

stop<br />

- Broken wire monitoring (only<br />

for current)<br />

- Short circuit monitoring (only<br />

for voltage)<br />

- Diagnostics inside module<br />

- required front connector: 20-pin<br />

6ES7 332-5HD01-0AB0<br />

8 outputs in 8 channel groups,<br />

redundant design possible<br />

- Resolution 12 bit + sign<br />

- Voltage 0/1...5/10 V; ±10 V<br />

(8 channels; 4 wires)<br />

- Current 0/4...20 mA; ±20 mA<br />

(8 channels; 2 wires)<br />

- Parameterizable substitute<br />

value output in case of CPU<br />

stop<br />

- Broken wire monitoring (only<br />

for current)<br />

- Short circuit monitoring (only<br />

for voltage)<br />

- Diagnostics inside module<br />

- required front connector: 40-pin<br />

6ES7 332-5HF00-0AB0<br />

4 outputs in 4 channel groups<br />

- Resolution 15 bit + sign<br />

- Voltage 0/1...5/10 V; ±10 V<br />

(4 channels; 4 wires)<br />

- Current 0/4...20 mA; ±20 mA<br />

(4 channels; 2 wires)<br />

- Parameterizable substitute<br />

value output in case of CPU<br />

stop<br />

- Isolated by channel<br />

- Diagnostics inside module<br />

- required front connector: 20-pin<br />

6ES7 332-7ND01-0AB0 B)<br />

11/14<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

B) Subject to export regulations: AL: N, ECCN: EAR99H


Process I/O<br />

ET 200M distributed I/O<br />

B) Subject to export regulations: AL: N, ECCN: EAR99H<br />

Ex modules [EEi xb]<br />

■ Overview<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

The following analog <strong>and</strong> digital I/O modules are suitable for use Ex Analog Modules<br />

in hazardous plants. They separate the non-intrinsically safe<br />

electrical circuits of the automation system <strong>and</strong> the intrinsically<br />

safe electrical circuit of the process. Sensors <strong>and</strong> actuators suitable<br />

for placing in zone 1 <strong>and</strong> 2 hazardous areas as well as intrinsically<br />

safe equipment compliant with DIN 50020 <strong>and</strong><br />

[EEx ib] IIC can be operated from these modules.<br />

Ex Analog Input Module<br />

4 inputs, 0/4...20 mA in<br />

4 channel groups, redundant<br />

design possible<br />

- Individually floating channels<br />

- Resolution 15 bit + sign<br />

6ES7 331-7RD00-0AB0<br />

All Ex modules with HART come with diagnostics capability<br />

(channel <strong>and</strong> module diagnostics).<br />

- Connection of 2 or 4-wire measurement<br />

transducer possible<br />

- Wire break monitoring<br />

- Measurement range monitor-<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

ing<br />

- Short-circuit-proof<br />

Ex Digital Modules<br />

- Diagnostics inside module<br />

- required front connector: 20-pin<br />

Ex Digital Input Modules<br />

8 inputs in 4 channel groups 6ES7 331-7SF00-0AB0<br />

4 NAMUR inputs in 4 channel<br />

groups, redundant design possible<br />

- Voltage supply to sensors<br />

8.2 V<br />

- Individually floating channels<br />

- Wire break <strong>and</strong> short-circuit<br />

monitoring (directly at the contact<br />

for contacts with external<br />

resistor circuit)<br />

- Diagnostics inside module<br />

- required front connector: 20-pin<br />

Ex Digital Output Module<br />

4 outputs, 24 V DC / 10 mA in<br />

4 channel groups, redundant<br />

design possible<br />

- Individually floating channels<br />

- Wire break monitoring<br />

- Short-circuit monitoring<br />

- Diagnostics inside module<br />

- required front connector: 20-pin<br />

6ES7 321-7RD00-0AB0<br />

6ES7 322-5SD00-0AB0<br />

- Resolution 15 bit + sign<br />

- Thermocouples type T, U, E, J,<br />

L, K, N, R, S, B (8 channels),<br />

internal compensation; external<br />

compensation with Pt100<br />

(2 channels), compensating<br />

box or 0/50°C comparison<br />

point<br />

- Resistance thermometer<br />

Pt100, Pt200, Ni100<br />

- Wire break monitoring<br />

- Diagnostics inside module<br />

- required front connector: 20-pin<br />

Note :<br />

A special front connector for the<br />

Ex analog input module 6ES7<br />

331-7SF00-0AB0 enables greater<br />

accuracy when taking thermocouple<br />

temperature measurements<br />

in "internal compensation"<br />

measuring mode (see the section<br />

"Accessories").<br />

4 outputs, 15 V DC / 20 mA in<br />

4 channel groups, redundant<br />

design possible<br />

- Individually floating channels<br />

- Wire break monitoring<br />

- Short-circuit monitoring<br />

- Diagnostics inside module<br />

- required front connector: 20-pin<br />

6ES7 322-5RD00-0AB0<br />

Ex Analog Output Module<br />

4 outputs, 0/4...20 mA in<br />

4 channel groups<br />

- Individually floating channels<br />

- Resolution 15 bit<br />

- for 2-wire measurement transducers<br />

- Wire break monitoring<br />

- Diagnostics inside module<br />

- required front connector: 20-pin<br />

6ES7 332-5RD00-0AB0 B)<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

11/15<br />

11


11<br />

Process I/O<br />

ET 200M distributed I/O<br />

Ex modules with HART<br />

■ Overview<br />

The Ex modules with HART (Highway Addressable Remote<br />

Transducer), which can be used in distributed I/O devices of the<br />

ET 200M (with IM 153-2 High Feature interface module), enable<br />

HART devices with approval for potentially explosive areas to be<br />

connected to SIMATIC PCS 7 automation systems .<br />

All measurement transducers <strong>and</strong> HART actuators that are certified<br />

for digital communication with the HART protocol can be<br />

connected through these modules.<br />

In addition, conventional transducers with 4 to 20 mA technology<br />

without HART protocol can also be connected<br />

All Ex modules with HART come with diagnostics capability<br />

(channel <strong>and</strong> module diagnostics).<br />

■ Application<br />

HART is a serial transfer protocol which is used to transfer additional<br />

parameter data, such as measurement range, isolation<br />

etc. to connected measuring transducers <strong>and</strong> actuators through<br />

a 4 to 20 mA power loop. The Ex I/O modules offered here enable<br />

the HART protocol to also be used for communication with<br />

HART devices in the hazardous area. The modules themselves<br />

<strong>and</strong> the ET 200M are positioned in the safe area of in Ex zone 2.<br />

A KEMA certificate confirms that the modules are approved for<br />

operation with HART devices in the hazardous area.<br />

■ Function<br />

The HART jobs can be initiated remotely for each channel<br />

through PROFIBUS DP. This usually takes place from the central<br />

engineering system of the SIMATIC PCS 7 process control system<br />

using SIMATIC PDM.<br />

The Ex modules with HART have the following characteristics:<br />

Connection compatibility with conventional analog modules of<br />

the ET 200M<br />

Additional communication option through the current loop<br />

Low energy requirement<br />

2 analog channels per module<br />

Each channel is a primary master of the HART protocol<br />

All channels can be operated by several clients simultaneously<br />

<strong>and</strong> independently of one another<br />

The channels are electrically isolated from one another<br />

Selectable current signal per channel:<br />

- 0...20 mA (without HART function)<br />

- 4...20 mA (with/without HART function)<br />

Parameterization<br />

Remote parameterization is possible for:<br />

- conversion time,<br />

- resolution,<br />

- limit values,<br />

- alarms, etc.<br />

Remote parameterization of the HART measurement transducers<br />

<strong>and</strong> actuators is possible with SIMATIC PDM through<br />

PROFIBUS DP<br />

It is still possible to parameterize the HART devices with an<br />

operator terminal.<br />

11/16<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

■ Technical specifications<br />

Detailed technical data of the Ex modules with HART can be<br />

found<br />

in the IK PI catalog (section "Distributed I/Os“) or<br />

in the Mall / CA 01 at "Distributed I/Os / ET 200M“<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

Ex Analog Input Module with<br />

HART [EEx ib]<br />

2 inputs, 0/4...20 mA in<br />

2 channel groups<br />

- Individually floating channels<br />

- Resolution: 15 bit + sign<br />

- Connection of 2 or 4-wire measurement<br />

transducers possible<br />

- Wire break monitoring<br />

- Short-circuit-proof<br />

- HART (2 or 4 wires)<br />

- required front connector: 20-pin<br />

6ES7 331-7TB00-0AB0 B)<br />

6ES7 650-0XX06-0XX0 B)<br />

HART bundle with<br />

Ex IO modules [EEx ib]<br />

for redundant PROFIBUS connection,<br />

comprising:<br />

two IM 153-2 High Feature interface<br />

modules<br />

8 Ex analog input modules with<br />

HART<br />

one IM 153 / IM 153 bus module<br />

four 2x40 bus modules for<br />

2 modules<br />

one 482 mm profile rail<br />

Note: The load power supply<br />

(PS 305/307) has to be ordered<br />

separately<br />

Ex Analog Output Module with<br />

HART [EEx ib]<br />

2 outputs, 0/4...20 mA in<br />

2 channel groups<br />

- Individually floating channels<br />

- Resolution: 12 bit + sign<br />

- For 2-wire actuators<br />

- Wire break monitoring<br />

-HART<br />

- required front connector: 20-pin<br />

6ES7 332-5TB00-0AB0 B)<br />

B) Subject to export regulations: AL: N, ECCN: EAR99H


Process I/O<br />

ET 200M distributed I/O<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

F modules<br />

■ Overview<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

The special safety functions of the failsafe systems are coordinated<br />

with the failsafe I/O modules of the distributed ET 200M<br />

SM 326F Failsafe Digital Output<br />

Module<br />

6ES7 326-2BF01-0AB0<br />

devices, whose job it is to also ensure plant safety should the 10 outputs, 24 V DC, 2 A,<br />

CPU fail. The failsafe signal modules of these peripheral devices<br />

(digital inputs/outputs, analog input) are able to diagnose internal<br />

<strong>and</strong> external errors, have a redundant setup on account of<br />

safety dem<strong>and</strong>s, <strong>and</strong> meet requirements up to SIL 3 (IEC 61508)<br />

or AK 6 (VDE 0801).<br />

floating in groups of 5, redundant<br />

design possible (outputs<br />

with internal diode)<br />

- SIL 2, SIL 3 | parameterizable<br />

(10 channels)<br />

- Wire break <strong>and</strong> short-circuit<br />

The input modules work in SIL 3/AK 6 with internal 2-of-2 channel<br />

evaluation. A safety response is triggered immediately there<br />

are any differences. The digital output modules enable safe disconnection<br />

through a second disconnect path in the event of a<br />

faulty output.<br />

monitoring<br />

- Diagnostics inside module<br />

- ProfiSafe frame<br />

SM 336F Failsafe Analog Input<br />

Module<br />

6 inputs, 4...20 mA, redundant<br />

6ES7 336-1HE00-0AB0<br />

■ Selection <strong>and</strong> Ordering Data<br />

SM 326F Failsafe Digital Input<br />

Module<br />

for floating contacts<br />

Order No.<br />

design possible<br />

- Isolated from the backplane<br />

bus<br />

- 2- or 4-wire connection<br />

- SIL 2: two-channel evaluation,<br />

6 sensors<br />

24 inputs, 24 V DC,<br />

floating in groups of 12, redundant<br />

design possible<br />

- 4 short-circuit resistant sensor<br />

power supplies, each for<br />

6 channels, floating in groups<br />

of 3<br />

- External sensor power supply<br />

6ES7 326-1BK00-0AB0<br />

- SIL 3: two-channel evaluation,<br />

12 sensors (adjustable tolerance<br />

window)<br />

- Wire break monitoring<br />

- Tolerance monitoring between<br />

2 sensors (SIL 3)<br />

- Diagnostics inside module<br />

- ProfiSafe frame<br />

possible<br />

- SIL 2: single-channel evaluation,<br />

24 channels<br />

- SIL 3: 2-of-2 evaluation on the<br />

module, 12 channels (adjust-<br />

Isolating module<br />

For F modules, 40 mm wide<br />

For isolation of F <strong>and</strong> st<strong>and</strong>ard<br />

modules in an ET 200M rack<br />

6ES7 195-7KF00-0XA0 B)<br />

able discrepancy time)<br />

- Short-circuit monitoring after<br />

L+<br />

- Discrepancy monitoring<br />

- Diagnostics inside module<br />

For signal isolation when using a<br />

copper bus connection (only F<br />

modules in a rack with IM 153-2)<br />

Isolating bus module<br />

6ES7 195-7HG00-0XA0<br />

- ProfiSafe frame<br />

80 mm wide, for isolating module,<br />

8 inputs, NAMUR [EEx ib]<br />

isolated by channel, redundant<br />

6ES7 326-1RF00-0AB0<br />

when using an active backplane<br />

bus<br />

design possible<br />

- 8 short-circuit resistant sensor<br />

power supplies, each for<br />

1 channel, mutually isolated<br />

- SIL 2: single-channel evaluation,<br />

8 channels<br />

- SIL 3: 2-of-2 evaluation on the<br />

module, 4 channels (adjustable<br />

discrepancy time)<br />

- Wire break <strong>and</strong> short-circuit<br />

monitoring (for contacts with<br />

external resistor circuit)<br />

- Discrepancy monitoring<br />

- Diagnostics inside module<br />

- ProfiSafe frame<br />

B) Subject to export regulations: AL: N, ECCN: EAR99H<br />

11/17<br />

11


11<br />

Process I/O<br />

ET 200M distributed I/O<br />

F modules<br />

■ Options<br />

11/18<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

Isolating module<br />

Following components can be used as accessories for the F<br />

modules:<br />

Isolating module<br />

- for isolation of F <strong>and</strong> st<strong>and</strong>ard modules in an ET 200M rack,<br />

- for signal isolation when using a copper bus connection<br />

(only F modules in a rack with IM 153-2)<br />

Isolating bus module for the isolating module, when using an<br />

active backplane bus<br />

Note<br />

The isolating module for F modules <strong>and</strong> the isolating bus module<br />

can only be used together. The 40 mm wide gap cannot be used<br />

for other modules.


■ Overview<br />

■ Integration<br />

The FM 355 controller module is the intelligent 4-channel controller<br />

module for universal control tasks. It can be used to control<br />

temperature, pressure <strong>and</strong> flow.<br />

The FM 355 module is available in four versions:<br />

FM 355 C is a continuous-action controller with 4 analog outputs<br />

for controlling analog actuators<br />

FM 355 S is a step or pulse controller with 8 digital outputs for<br />

controlling motor-driven (integrating) actuators or binary controlled<br />

actuators (e.g. electrical heating strips <strong>and</strong> cartridges)<br />

FM 355-2 C/S is specially optimized for temperature control<br />

applications with user-friendly integrated online self-optimization<br />

■ Function<br />

The FM 355 / FM 355-2 modules have four separate control<br />

channels. These controllers have the following features:<br />

Predefined controller structures for<br />

- fixed-setpoint control,<br />

- cascade control,<br />

- ratio control,<br />

- 3-component control<br />

Various operating modes:<br />

- automatic mode,<br />

- manual mode,<br />

-safety mode,<br />

- follow-up mode,<br />

- backup mode<br />

Sampling interval (dependent on the resolution of the analog<br />

inputs <strong>and</strong> the compensation input):<br />

- at 12 bit: 20 ms to 100 ms (only FM 355-2)<br />

- at 14 bit: 100 ms to 500 ms (dependent on the number of enabled<br />

analog inputs)<br />

2 control algorithms:<br />

- self-optimized temperature control algorithm,<br />

- PID algorithm<br />

Integrated online self-optimization without configuration (only<br />

FM 355-2)<br />

- for faster adoption of the operating point<br />

User-friendly controller optimization<br />

Backup mode: The controller can maintain its control function<br />

in the event of CPU failure or CPU stop. Programmable safety<br />

setpoint values or safety manipulated variables are set for this<br />

purpose.<br />

Feedforward control: The analog inputs can be optionally<br />

used for feedforward control as well as for actual value acquisition.<br />

Process I/O<br />

ET 200M distributed I/O<br />

Controller modules<br />

Use in SIMATIC PCS 7<br />

With the FM 355 / FM 355-2 modules in SIMATIC PCS 7 it is possible<br />

to implement controller tasks outside the S7-400 CPU of the<br />

automation system. The modules have not only controller structures<br />

but also analog <strong>and</strong> digital channels, thus eliminating the<br />

need for additional modules to detect the setpoint/actual value<br />

or to control the actuator.<br />

On the one h<strong>and</strong> this reduces the work load for the CPU, on the<br />

other h<strong>and</strong> it enables a backup behavior, i.e. the control system<br />

continues to work even if the CPU fails. In this case the FM 355<br />

module can be operated further with an OP17 operator panel<br />

(does not apply for FM 355-2).<br />

If the CPU of the automation system fails, the FM 355 module can<br />

be operated further with an OP17 operator panel. The operator<br />

panel is connected to the PROFIBUS DP field bus for this purpose.<br />

The CPU of the automation system can surrender input<br />

privilege to the operator panel in normal operation as well. The<br />

parameters that can be operated with the operator panel are setpoint<br />

value <strong>and</strong> manipulated variable. If the FM 355 module is<br />

operated from the operator panel, the automation system reads<br />

back the values operable from the operator panel after the input<br />

privilege is withdrawn or recovered again. Bumpless continuation<br />

of the operations is thus assured.<br />

IM 153-2 High Feature interface modules are needed for the<br />

PROFIBUS DP connection when the FM 355 / FM 355-2 controller<br />

modules are used in ET 200M.<br />

PCS 7 blocks<br />

CFC blocks with OS faceplates for all FM 355 modules are included<br />

in delivery of the st<strong>and</strong>ard SIMATIC PCS 7 library (part of<br />

<strong>Engineering</strong> Software). These blocks are integrated in the PCS 7<br />

driver concept, thus resulting in a homogeneous integration<br />

(incl. automatic diagnostics messages).<br />

Parameterization in HW Config<br />

A configuration package containing all parameterization masks<br />

required for configuring, parameterizing <strong>and</strong> commissioning are<br />

included in delivery of the FM 355 C <strong>and</strong> FM 355 S controller<br />

modules.<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

11/19<br />

11


11<br />

Process I/O<br />

ET 200M distributed I/O<br />

Controller modules<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

FM 355 C Controller Module 6ES7 355-0VH10-0AE0<br />

With 4 analog outputs for<br />

4 continuous-action controllers<br />

required front connector: 2 x 20pin<br />

Incl. multi-lingual configuration<br />

package, manual <strong>and</strong> Getting<br />

Started (German, English,<br />

French, Italian) on CD-ROM<br />

FM 355 S Controller Module 6ES7 355-1VH10-0AE0<br />

With 8 digital outputs for 4 step or<br />

pulse controllers<br />

required front connector: 2 x 20pin<br />

Incl. multi-lingual configuration<br />

package, manual <strong>and</strong> Getting<br />

Started (German, English,<br />

French, Italian) on CD-ROM<br />

11/20<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

FM 355-2 C Temperature Con- 6ES7 355-2CH00-0AE0<br />

troller Module<br />

With 4 analog outputs for<br />

4 continuous-action controllers<br />

required front connector: 2 x 20pin<br />

Incl. multi-lingual configuration<br />

package, manual <strong>and</strong> Getting<br />

Started (German, English,<br />

French, Italian) on CD-ROM<br />

FM 355-2 S Temperature Con- 6ES7 355-2SH00-0AE0<br />

troller Module<br />

With 8 digital outputs for 4 step or<br />

pulse controllers<br />

required front connector: 2 x 20pin<br />

Incl. multi-lingual configuration<br />

package, manual <strong>and</strong> Getting<br />

Started (German, English,<br />

French, Italian) on CD-ROM<br />

Following operator panels can be<br />

used specially for local operation<br />

of the FM 355 C/S:<br />

SIMATIC OP17/DP operator<br />

panel<br />

6AV3 617-1JC20-0AX1<br />

Note:<br />

In the case of the FM 355 C <strong>and</strong> FM 355 S controller module, the<br />

channels are not electrically isolated from one another<br />

Counter module<br />

■ Overview<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

The FM 350-1 counter module is a single-channel intelligent FM 350-1 Counter Module 6ES7 350-1AH03-0AE0<br />

counter module for simple counting tasks, designed for the di- Counting functions up to 500 kHz<br />

rect connection of incremental encoders. It provides a compari- 1 channel for the connection of<br />

son function with 2 preselectable reference values, as well as integrated<br />

digital outputs for outputing a reaction upon reaching<br />

5 V <strong>and</strong> 24 V incremental encoders<br />

the reference value.<br />

required front connector:<br />

The FM 350-2 counter module is an eight-channel intelligent<br />

counter module for universal counting <strong>and</strong> measuring tasks, as<br />

well as for simple positioning jobs (max. 4 axes).<br />

1x20-pin<br />

incl. configuration package on<br />

CD-ROM<br />

FM 350-2 Counter Module<br />

8 channels with max. 20 kHz<br />

counting frequency, whereby up<br />

to 4 channels are available when<br />

used with SIMATIC PCS 7; for<br />

24 V transducers, for the following<br />

tasks:<br />

counting, frequency measurement,<br />

speed measurement,<br />

period measurement, dosing<br />

required front connector:<br />

1x40-pin<br />

incl. configuration package on<br />

CD-ROM<br />

6ES7 350-2AH00-0AE0


■ Overview<br />

The intrinsically safe distributed ET 200iS I/O device in degree of<br />

protection IP30 can be installed directly in Ex zone 1 or 2<br />

(EEx de ib [ia/ib] IIC T4) as well as in non-hazardous areas. The<br />

sensors/actuators can also be placed in zone 0 if required. The<br />

ET 200iS is connected through PROFIBUS DP. With the help of<br />

an isolating transformer (RS485-iS coupler) it is possible for<br />

PROFIBUS DP to be taken into Ex zone 1 as an intrinsically safe<br />

bus.<br />

Process I/O<br />

ET 200iS distributed I/O<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

Introduction<br />

The ET 200iS is of bit-modular design: pressure-encapsulated<br />

power supply, interface module for PROFIBUS DP, <strong>and</strong> up to<br />

32 electronic modules. HART capability is st<strong>and</strong>ard, as is the hot<br />

swapping of individual modules without a fire certificate. Data<br />

transfer rates of up to 1.5 Mbit/s are possible.<br />

Integration in SIMATIC PCS 7 covers CFC driver blocks, system<br />

diagnostics <strong>and</strong> time stamp. Putting the ET 200iS into operation<br />

is easy <strong>and</strong> user-friendly. The configuration of electronic modules<br />

<strong>and</strong> the parameterization of field devices are performed<br />

with SIMATIC PDM in the engineering system.<br />

The range of electronic modules covers a NAMUR digital input<br />

module, a digital output module <strong>and</strong> analog input/output modules<br />

with <strong>and</strong> without HART.<br />

SIMATIC PDM is needed to paramterize the electronic modules<br />

<strong>and</strong> the connected HART field devices.<br />

Note :<br />

Apart from these selected modules it is also possible to use -<br />

with limitations in functions - all other ET 200iS electronic modules<br />

from the current range.<br />

■ Technical specifications<br />

Detailed technical data on the ET 200iS can be found<br />

in the IK PI catalog or<br />

in the Mall / CA 01 at "Distributed I/Os / ET 200iS“<br />

Stainless steel wall housing<br />

■ Design<br />

■ Selection <strong>and</strong> Ordering Data<br />

Stainless steel housing with<br />

IP66 for Ex zone 1 in protection<br />

class EEx e<br />

Empty housing<br />

excl. installation of modules<br />

Order No.<br />

- Wall housing 600 x 400 x 230<br />

for accommodating as many<br />

as 11 ET 200iS modules<br />

6DL2 804-0AA00<br />

- Wall housing 800 x 400 x 230<br />

for accommodating as many<br />

as 16 ET 200iS modules<br />

6DL2 804-0AB00<br />

- Wall housing 1050 x 400 x 230<br />

for accommodating as many<br />

as 25 ET 200iS modules<br />

Empty housing<br />

incl. installation of an ET 200iS<br />

system<br />

6DL2 804-0AC00<br />

Stainless steel wall housing<br />

ET 200iS modules can also be installed in stainless steel wall<br />

housings designed to meet more exacting protection requirements.<br />

The housings are available in three different sizes. They<br />

comply with degree of protection IP66 <strong>and</strong> can also be used in<br />

Ex zone 1.<br />

1)<br />

- Wall housing 600 x 400 x 230 6DL2 804-1AA00<br />

incl. installation of one<br />

ET 200iS with as many as<br />

11 I/O modules<br />

- Wall housing 800 x 400 x 230 6DL2 804-1AB00<br />

incl. installation of one<br />

ET 200iS with as many as<br />

16 I/O modules<br />

- Wall housing 1050 x 400 x 230<br />

incl. installation of one<br />

ET 200iS with as many as<br />

25 I/O modules<br />

6DL2 804-1AC00<br />

1) The ET 200iS components have to be ordered separately<br />

11/21<br />

11


11<br />

Process I/O<br />

ET 200iS distributed I/O<br />

Electronic modules<br />

■ Overview<br />

The electronic modules are plugged into the corresponding<br />

terminal modules TM-E30S-44iS (screw-type terminal) or<br />

TM-E30C-44iS (cage-clamp method) (to be ordered separately).<br />

The modules are mechanically coded for automatic protection<br />

against polarity reversal when they are plugged in.<br />

Modules can be replaced under potentially explosive conditions<br />

during runtime.<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

Digital electronic modules<br />

Digital input module for floating<br />

contacts<br />

4 x NAMUR or contact with resistor<br />

circuit<br />

- Short-circuit monitoring<br />

- Wire break monitoring<br />

- Chatter monitoring<br />

- Diagnostics inside module<br />

Digital Output Module for Ex-i<br />

Solenoid Valves, DC Relays <strong>and</strong><br />

Actuators<br />

2 x 25 V DC, 25 mA<br />

- Short-circuit monitoring<br />

- Wire break monitoring<br />

- Parameterizable connection of<br />

a default value in case of CPU<br />

failure<br />

- Diagnostics inside module<br />

Analog Electronic Modules<br />

Analog Input / Current Measurement<br />

2 x 4...20 mA, 2-wire transducer<br />

- Resolution 12 bit + sign<br />

- Short-circuit monitoring<br />

- Wire break monitoring<br />

- Diagnostics inside module<br />

2 x 0(4)...20 mA, 4-wire transducer<br />

- Resolution 12 bit + sign<br />

- Wire break monitoring<br />

- Diagnostics inside module<br />

2 x 4...20 mA, HART; 2-wire<br />

measurement transducer<br />

- Resolution 12 bit + sign<br />

- Short-circuit monitoring<br />

- Wire break monitoring<br />

- Diagnostics inside module<br />

2 x 4...20 mA, HART; 4-wire<br />

transducer<br />

- Resolution 12 bit + sign<br />

- Wire break monitoring<br />

- Diagnostics inside module<br />

11/22<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

6ES7 131-5RD00-0AB0 B)<br />

6ES7 132-5SB00-0AB0 B)<br />

6ES7 134-5RB00-0AB0 B)<br />

6ES7 134-5RB50-0AB0 B)<br />

6ES7 134-5TB00-0AB0 B)<br />

6ES7 134-5TB50-0AB0 B)<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

Analog Input / Temperature<br />

Measurement<br />

2 x TC (thermocouples)<br />

- Type E, N, J, K, L, S, R, B, T, U<br />

- Resolution 15 bit + sign<br />

- Compensation through Pt100<br />

with module 6ES7 134-5SB50-<br />

0AB0 of the same station<br />

- Wire break monitoring<br />

- Diagnostics inside module<br />

2 x RTD, resistance thermometer<br />

Pt100/Ni100<br />

- 2-, 3-, 4-wire<br />

- Resolution 15 bit + sign<br />

- Short-circuit monitoring<br />

- Wire break monitoring<br />

- Diagnostics inside module<br />

Analog Output Module<br />

2 x 0(4)...20 mA, 2-wire transducer<br />

- Resolution: 14 bit<br />

- Short-circuit monitoring<br />

- Wire break monitoring<br />

- Diagnostics inside module<br />

- Parameterizable default value<br />

in case of CPU failure<br />

2 x 0(4)...20 mA, 2-wire transducer<br />

HART<br />

- Resolution: 14 bit<br />

- Short-circuit monitoring<br />

- Wire break monitoring<br />

- Diagnostics inside module<br />

- Parameterizable default value<br />

in case of CPU failure<br />

Terminal Module<br />

TM-E30S44-iS<br />

Terminal module for ET 200iS,<br />

for integrating electronic modules,<br />

screw-type terminals<br />

TM-E30C44-iS<br />

Terminal module for ET 200iS,<br />

for integrating electronic modules,<br />

spring-loaded terminals<br />

6ES7 134-5SB00-0AB0 B)<br />

6ES7 134-5SB50-0AB0 B)<br />

6ES7 135-5RB00-0AB0 B)<br />

6ES7 135-5TB00-0AB0 B)<br />

6ES7 193-5CB00-0AA0<br />

6ES7 193-5CB10-0AA0<br />

B) Subject to export regulations: AL: N, ECCN: EAR99H


Process I/O<br />

ET 200iS distributed I/O<br />

Power supply <strong>and</strong> interface modules<br />

■ Overview<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

Thepower supply module is plugged into the corresponding ter- Starter Package for ET 200iS 6ES7 151-2AR00-0AB0 A)<br />

minal module TM-PS-iS (to be ordered separately). The power IM 151-2 interface module <strong>and</strong><br />

supply unit<br />

power supply module, each with<br />

provides a reliable isolated power supply for the ET 200iS with<br />

the necessary operating voltages for:<br />

- logic (through the backplane bus)<br />

- PROFIBUS DP interface of IM 151-2<br />

- power bus<br />

takes over the safety limit of the output voltage<br />

has an explosion-proof plastic enclosure (explosion protection<br />

type EX d)<br />

terminal module <strong>and</strong> RS485-iS<br />

coupler<br />

With SIMATIC PDM parameter<br />

assignment software, incl. integration<br />

in STEP 7<br />

Power Supply<br />

Power Supply Module<br />

For ET 200iS<br />

6ES7 138-5EA00-0AA0 B)<br />

The interface module IM151-2 is plugged into the corresponding<br />

TM-PS-iS Terminal Module 6ES7 193-5DA00-0AA0<br />

terminal module TM-IM-iS (to be ordered separately). The interface<br />

module IM 151-2 has the following properties:<br />

For integrating the power supply<br />

module<br />

connects the ET 200iS to PROFIBUS DP<br />

Bus Interface<br />

prepares data for the fitted electronic modules<br />

Interface Module IM 151-2 6ES7 151-2AA00-0AB0<br />

the PROFIBUS address of ET 200iS can be adjusted by switch For ET 200iS, incl. power bus terminating<br />

module<br />

A Starter Package for ET 200iS is avaliable as a complete package.<br />

It contains an IM 151-2 interface module <strong>and</strong> power supply<br />

module, each with a terminal module <strong>and</strong> RS485-iS coupler, with<br />

SIMATIC PDM parameter assignment software incl. integration<br />

TM-IM-iS Terminal Module<br />

For integrating the IM 151-2 interface<br />

module<br />

6ES7 193-5DB00-0AA0<br />

in STEP 7.<br />

Accessories<br />

The RS485-iS coupler is a field bus isolating transformer that en- Bus Connector<br />

6ES7 972-0BA30-0XA0<br />

ables PROFIBUS to be run intrinsically safely in hazardous ar- For intrinsically safe PROFIBUS,<br />

eas. The 6ES7972-0DA30-0XA0 plug with special (passive) ter- 1.5Mbit/s<br />

minating resistor is required to terminate the RS 485-iS.<br />

RS485-iS Coupler<br />

PROFIBUS must be run intrinsically<br />

safely in hazardous areas<br />

through installation of a field bus<br />

isolating transformer<br />

6ES7 972-0AC80-0XA0<br />

Bus Connector<br />

Connector with special (passive)<br />

terminating resistor for terminating<br />

the RS485-iS<br />

6ES7 972-0DA30-0XA0<br />

A) Subject to export regulations: AL: N, ECCN: 5D992B2<br />

B) Subject to export regulations: AL: N, ECCN: EAR99H<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

11/23<br />

11


11<br />

Process I/O<br />

ET 200S distributed I/O<br />

Introduction<br />

■ Overview<br />

The ET 200S is a bit-modular distributed I/O system rated for<br />

IP20 <strong>and</strong> approved for operation in Ex zone 2 (except the operation<br />

of motor starters). It is designed with permanent wiring that<br />

supports the hot swapping of I/O modules (with hot work permits).<br />

The range of I/Os that can be used with SIMATIC PCS 7 includes<br />

power modules for electronic modules <strong>and</strong> motor starters, analog<br />

<strong>and</strong> digital signal modules, <strong>and</strong> motor starters up to 7.5 kW.<br />

The implementation of safety engineering applications is supported<br />

by:<br />

failsafe terminal, power <strong>and</strong> electronic modules<br />

SIGUARD safety engineering for motor starter applications in<br />

plants of safety category 2 to 4 (EN 954-1)<br />

Note :<br />

Apart from these selected modules it is also possible to use -<br />

with limitations in functions - all other ET 200S electronic modules<br />

from the current range.<br />

11/24<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

■ Design<br />

Main components of the distributed ET 200S I/O system:<br />

Terminal modules<br />

enable the electrical <strong>and</strong> mechanical connection of the<br />

I/O modules <strong>and</strong> carry the terminals for the process wiring:<br />

- TM-P Terminal Modules for Power Modules<br />

- TM-E Terminal Modules for Electronic Modules<br />

- TM-DS/TM-RS Terminal Modules for Motor Starters <strong>and</strong><br />

TM-xB Expansion Modules<br />

IM 151 interface module<br />

for connecting PROFIBUS DP to the ET 200S station. The terminal<br />

module is included in the scope of supply.<br />

Power modules for PM-E electronic modules <strong>and</strong> PM-D motor<br />

starters<br />

- for individual grouping of load <strong>and</strong> sensor supply voltages<br />

<strong>and</strong> their monitoring as well as<br />

for the safe shutting down of digital output modules with<br />

PROFIsafe<br />

- for supplying <strong>and</strong> monitoring the auxiliary voltages for motor<br />

starters as well as for the shutting down of a complete group<br />

of motor starters<br />

Electronic modules<br />

for process data exchange:<br />

- digital electronic modules for connecting digital sensors <strong>and</strong><br />

actuators<br />

- analog electronic modules for connecting analog sensors<br />

<strong>and</strong> actuators<br />

Motor starter modules<br />

for switching <strong>and</strong> protecting three-phase current loads<br />

Accessories<br />

- Reserve module for reserving a slot for an electronic module<br />

- Label sheets for printing ID labels on a laser printer<br />

- Shield connection: shield connecting element, shield terminal,<br />

ground terminal, copper voltage bus 3 x 10 mm;<br />

components for the low-impedance connection of cable<br />

shielding at low cost of installation


Mounting<br />

The terminal modules that can be mounted on a profile rail<br />

(35 x 15 x 7.5 or 15 mm) form the carrier system for the<br />

I/O modules. They are used for the process wiring <strong>and</strong> enable<br />

the electrical <strong>and</strong> mechanical connection of the I/O modules.<br />

The terminal modules can be prewired <strong>and</strong> tested without the<br />

I/O modules. Later the I/O modules are simply plugged in place.<br />

Terminal modules are available with screw connections, springloaded<br />

terminals or Fast Connect design for fast mounting.<br />

The automatic coding of the I/O modules reliably prevents the<br />

risk of injury to persons <strong>and</strong>/or destruction of modules through<br />

accidental mounting of the wrong module.<br />

Expansion limits<br />

Depending on the IM 151 interface module used, the expansion<br />

of an ET 200S station is subject to the following limits:<br />

A maximum total of 63 I/O modules per station can be inserted<br />

between interface module <strong>and</strong> terminating module.<br />

The maximum permissible width of an ET 200S station is 2 m.<br />

The maximum address volume of all the inserted I/O modules<br />

is 244 byte for input data <strong>and</strong> 244 byte for output data.<br />

The maximum number of parameters is restricted to 244 byte<br />

per station.<br />

ET 200S configuration<br />

The ET 200S Configurator software tool is available for st<strong>and</strong>ard<br />

configuration. The data entered can be transferred directly to<br />

STEP7, <strong>and</strong> the electronic ordering of components is also possible<br />

through the Mall.<br />

■ Technical specifications<br />

Process I/O<br />

ET 200S distributed I/O<br />

Detailed technical data on the ET 200S can be found<br />

in the IK PI catalog or<br />

in the Mall / CA 01 at "Distributed I/Os / ET 200S“<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

Introduction<br />

11/25<br />

11


11<br />

Process I/O<br />

ET 200S distributed I/O<br />

Terminal modules<br />

■ Overview<br />

Mechanical modules for integrating the power <strong>and</strong> electronic<br />

modules as well as the motor starters <strong>and</strong> expansion modules<br />

(ordering data of the terminal modules for motor starters <strong>and</strong><br />

expansion module can be found at "Motor starters")<br />

For setting up permanent wiring through self-configuring voltage<br />

buses<br />

Alternatively with screw-type or spring-loaded terminals <strong>and</strong><br />

Fast Connect design<br />

Replaceable terminal box<br />

Automatic coding of the electronic modules<br />

Self-shielding of the backplane bus for high data security<br />

Optional plug-in shield connection<br />

Color coding facility for the terminals <strong>and</strong> for identifying the<br />

slot numbers<br />

11/26<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

Terminal Modules TM-P for<br />

Power Modules<br />

TM-P15S23-A1 Terminal Module<br />

2 x 3 terminals, terminal access to<br />

AUX1 bus, AUX1 interconnected<br />

to the left, screw-type terminals<br />

Ordering unit 1 piece<br />

TM-P15C23-A1 Terminal Module<br />

2 x 3 terminals, terminal access to<br />

AUX1 bus, AUX1 interconnected<br />

to the left, spring-type terminals<br />

Ordering unit 1 piece<br />

TM-P15N23-A1 Terminal Module<br />

2 x 3 terminals, terminal access to<br />

AUX1 bus, AUX1 interconnected<br />

to the left, FastConnect<br />

Ordering unit 1 piece<br />

TM-P15S23-A0 Terminal Module<br />

2 x 3 terminals, terminal access to<br />

AUX1 bus, AUX1 interrupted to<br />

the left, screw-type terminals<br />

Ordering unit 1 piece<br />

TM-P15C23-A0 Terminal Module<br />

2 x 3 terminals, terminal access to<br />

AUX1 bus, AUX1 interrupted to<br />

the left, spring-type terminals<br />

Ordering unit 1 piece<br />

TM-P15N23-A0 Terminal Module<br />

2 x 3 terminals, terminal access to<br />

AUX1 bus, AUX1 interrupted to<br />

the left, FastConnect<br />

Ordering unit 1 piece<br />

TM-P15S22-01 Terminal Module<br />

2 x 2 terminals, no terminal<br />

access to AUX1 bus, AUX1 interconnected<br />

to the left, screw-type<br />

terminals<br />

Ordering unit 1 piece<br />

TM-P15C22-01 Terminal Module<br />

2 x 2 terminals, no terminal<br />

access to AUX1 bus, AUX1 interconnected<br />

to the left, springloaded<br />

terminals<br />

Ordering unit 1 piece<br />

TM-P15N22-01 Terminal Module<br />

2 x 2 terminals, no terminal<br />

access to AUX1 bus, AUX1 interconnected<br />

to the left, FastConnect<br />

Ordering unit 1 piece<br />

TM-P30S44-A0 Terminal Module<br />

7 x 2 terminals, terminal access to<br />

AUX1 bus, AUX1 interrupted to<br />

the left, screw-type terminals for<br />

PM-E F PROFIsafe<br />

Ordering unit 1 piece<br />

TM-P30C44-A0 Terminal Module<br />

7 x 2 terminals, terminal access to<br />

AUX1 bus, AUX1 interrupted to<br />

the left, spring-loaded terminals<br />

for PM-E F PROFIsafe<br />

Ordering unit 1 piece<br />

6ES7 193-4CC20-0AA0<br />

6ES7 193-4CC30-0AA0<br />

6ES7 193-4CC70-0AA0<br />

6ES7 193-4CD20-0AA0<br />

6ES7 193-4CD30-0AA0<br />

6ES7 193-4CD70-0AA0<br />

6ES7 193-4CE00-0AA0<br />

6ES7 193-4CE10-0AA0<br />

6ES7 193-4CE60-0AA0<br />

6ES7 193-4CK20-0AA0<br />

6ES7 193-4CK30-0AA0


■ Selection <strong>and</strong> Ordering Data Order No.<br />

TM-E Terminal Modules for<br />

Electronic Modules<br />

TM-E15S24-A1 Terminal Module 6ES7 193-4CA20-0AA0<br />

2 x 4 terminals, terminal access to<br />

AUX1 bus, AUX1 interconnected<br />

to the left, screw-type terminals<br />

Ordering unit 5 pcs<br />

TM-E15C24-A1 Terminal Module 6ES7 193-4CA30-0AA0<br />

2 x 4 terminals, terminal access to<br />

AUX1 bus, AUX1 interconnected<br />

to the left, spring-type terminals<br />

Ordering unit 5 pcs<br />

TM-E15N24-A1 Terminal Module 6ES7 193-4CA70-0AA0<br />

2 x 4 terminals, terminal access to<br />

AUX1 bus, AUX1 interconnected<br />

to the left, FastConnect<br />

Ordering unit 5 pcs<br />

TM-E15S24-01 Terminal Module 6ES7 193-4CB20-0AA0<br />

2 x 4 terminals, no terminal<br />

access to AUX1 bus, AUX1 interconnected<br />

to the left, screw-type<br />

terminals<br />

Ordering unit 5 pcs<br />

TM-E15C24-01 Terminal Module 6ES7 193-4CB30-0AA0<br />

2 x 4 terminals, no terminal<br />

access to AUX1 bus, AUX1 interconnected<br />

to the left, spring-type<br />

terminals<br />

Ordering unit 5 pcs<br />

TM-E15N24-01 Terminal Module 6ES7 193-4CB70-0AA0<br />

2 x 4 terminals, no terminal<br />

access to AUX1 bus, AUX1 interconnected<br />

to the left, FastConnect<br />

Ordering unit 5 pcs<br />

TM-E15S23-01 Terminal Module 6ES7 193-4CB00-0AA0<br />

2 x 3 terminals, no terminal<br />

access to AUX1 bus, AUX1 interconnected<br />

to the left, screw-type<br />

terminals<br />

Ordering unit 5 pcs<br />

TM-E15C23-01 Terminal Module 6ES7 193-4CB10-0AA0<br />

2 x 3 terminals, no terminal<br />

access to AUX1 bus, AUX1 interconnected<br />

to the left, spring-type<br />

terminals<br />

Ordering unit 5 pcs<br />

TM-E15N23-01 Terminal Module 6ES7 193-4CB60-0AA0<br />

2 x 3 terminals, no terminal<br />

access to AUX1 bus, AUX1 interconnected<br />

to the left, FastConnect<br />

Ordering unit 5 pcs<br />

TM-E15N26-A1 Terminal Module 6ES7 193-4CA80-0AA0<br />

2 x 6 terminals, terminal access to<br />

AUX1 bus, AUX1 interconnected<br />

to the left, FastConnect<br />

Ordering unit 5 pcs<br />

TM-E15S26-A1 Terminal Module 6ES7 193-4CA40-0AA0<br />

2 x 6 terminals, terminal access to<br />

AUX1 bus, AUX1 interconnected<br />

to the left, screw-type terminals<br />

Ordering unit 5 pcs<br />

Process I/O<br />

ET 200S distributed I/O<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

Terminal modules<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

TM-E15C26-A1 Terminal Module 6ES7 193-4CA50-0AA0<br />

2 x 6 terminals, terminal access to<br />

AUX1 bus, AUX1 interconnected<br />

to the left, spring-type terminals<br />

Ordering unit 5 pcs<br />

TM-E30S44-01 Terminal Module 6ES7 193-4CG20-0AA0<br />

4 x 4 terminals, no terminal<br />

access to AUX1 bus, AUX1 interconnected<br />

to the left, screw-type<br />

terminals<br />

Ordering unit 1 piece<br />

TM-E30C44-01 Terminal Module 6ES7 193-4CG30-0AA0<br />

4 x 4 terminals, no terminal<br />

access to AUX1 bus, AUX1 interconnected<br />

to the left, spring-type<br />

terminals<br />

Ordering unit 1 piece<br />

TM-E30S46-A1 Terminal Module 6ES7 193-4CF40-0AA0<br />

4 x 6 terminals, terminal access to<br />

AUX1 bus, AUX1 interconnected<br />

to the left, screw-type terminals<br />

Ordering unit 1 piece<br />

TM-E30C46-A1 Terminal Module 6ES7 193-4CF50-0AA0<br />

4 x 6 terminals, terminal access to<br />

AUX1 bus, AUX1 interconnected<br />

to the left, spring-type terminals<br />

Ordering unit 1 piece<br />

TM-E15S24-AT Terminal Module 6ES7 193-4CL20-0AA0<br />

For internal temperature compensation<br />

with 2AI TC High Feature,<br />

screw-type terminals<br />

Ordering unit 1 piece<br />

TM-E15C24-AT Terminal Module 6ES7 193-4CL30-0AA0<br />

For internal temperature compensation<br />

with 2AI TC High Feature,<br />

spring-loaded terminals<br />

Ordering unit 1 piece<br />

Accessories for the terminal modules, see the IK PI catalog or A&D Mall /<br />

CA 01 at "Distributed I/Os / ET 200S“<br />

11/27<br />

11


11<br />

Process I/O<br />

ET 200S distributed I/O<br />

Interface modules<br />

■ Overview<br />

IM 151-1 High Feature (RS 485)<br />

Interface module for electrical connection of the ET 200S to<br />

PROFIBUS DP through copper bus cables<br />

H<strong>and</strong>les all data exchange with the PROFIBUS DP master<br />

Power modules<br />

■ Overview<br />

Power Modules for PM-E Electronic Modules<br />

For monitoring <strong>and</strong>, depending on the version, securing the<br />

load <strong>and</strong> encoder supply voltage to the electronic module<br />

Diagnostic message of voltage <strong>and</strong> fuse drop (can be<br />

switched off through configuration)<br />

PM-E F PROFIsafe Failsafe Power Module<br />

For safely switching off downstream digital st<strong>and</strong>ard output<br />

modules, 24 V DC up to 10 A (AK 4, SIL 2)<br />

Also 2 digital outputs, 24 V DC / 2 A (AK 6, SIL 3)<br />

Power modules for PM-D motor starters<br />

For incoming supply <strong>and</strong> monitoring of auxiliary voltages for<br />

motor starters<br />

Possible to switch off a complete group of motor starters without<br />

additional effort (safety category 1 according to EN 954-1)<br />

PM-D F PROFIsafe failsafe power module for failsafe motor<br />

starters<br />

In EMERGENCY STOP applications the failsafe motor starters<br />

are shut down selectively by means of the upstream PM-D F<br />

PROFIsafe power module. A total of 6 shut-down groups can<br />

be formed per power module. The interface from ET 200S<br />

PROFIsafe to systems with conventional safety engineering is<br />

formed by F-CM failsafe contact multipliers with 4 floating contacts.<br />

11/28<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

IM151-1 Interface Module<br />

For ET 200S, High Feature<br />

6ES7 151-1BA00-0AB0 B)<br />

B) Subject to export regulations: AL: N, ECCN: EAR99H<br />

■ Selection <strong>and</strong> Ordering Data<br />

Power Modules for PM-E Electronic<br />

Modules<br />

PM-E Power Module<br />

Order No.<br />

24 V DC/10 A<br />

- Monitoring of the load voltage<br />

6ES7 138-4CA00-0AA0 B)<br />

24 V DC, 48 V; 24 V, 48 V, 120 V<br />

AC; 230 V AC<br />

- Monitoring of the fuse<br />

- Monitoring of the load voltage<br />

6ES7 138-4CB10-0AB0 B)<br />

PM-E F Failsafe Power Module<br />

PM-E F PROFIsafe<br />

- 1 x relay 24 V DC/10 A, P/M<br />

switching, for switching off<br />

downstream st<strong>and</strong>ard digital<br />

output modules (up to AK 4,<br />

SIL 2)<br />

- 2 x 24 V DC/2 A, P/M switching,<br />

with broken wire monitoring<br />

by channel (with "1" signal)<br />

- Safe monitoring of communication<br />

with PROFIsafe<br />

- Diagnostics inside module<br />

- Overload diagnostics by channel<br />

Power Module for PM-D Motor<br />

Starters<br />

PM-D Power Module<br />

2 x 24 V DC/10 A<br />

- For supplying the electronics<br />

<strong>and</strong> contactors of motor starters<br />

- Monitoring of the load voltage<br />

Power Modules for PM-D F Failsafe<br />

Motor Starters<br />

PM-D F PROFIsafe Power Module<br />

For 6 vector groups; safety-oriented<br />

F-CM Failsafe Contact Multiplier<br />

Expansion to PM-D F PROFIsafe;<br />

PM-D F X1 Failsafe Power Module<br />

Overvoltage protection; for<br />

incoming supply of external emergency<br />

stop signals; for 6 vector<br />

groups<br />

6ES7 138-4CF01-0AB0<br />

3RK1 903-0BA00 F)<br />

3RK1 903-3BA00<br />

3RK1 903-3CA00<br />

3RK1 903-3DA00<br />

B) Subject to export regulations: AL: N, ECCN: EAR99H<br />

F) Subject to export regulations: AL: N, ECCN: EAR99


■ Overview<br />

2- <strong>and</strong> 4-channel digital inputs <strong>and</strong> outputs for the ET 200S<br />

Can be connected to TM-E terminal modules with automatic<br />

coding<br />

High-feature variants for enhanced plant availability, additional<br />

functions <strong>and</strong> comprehensive diagnostics<br />

Module replacement during operation <strong>and</strong> under power (hot<br />

swapping)<br />

Failsafe digital input module 4/8 F-DI PROFIsafe<br />

Failsafe digital output module 4 F-DO PROFIsafe 24 V DC/2 A<br />

Isolated from the backplane bus<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

Digital Inputs for Floating Contacts<br />

DI 2 x 24 V DC, st<strong>and</strong>ard 6ES7 131-4BB00-0AA0 B)<br />

DI 4 x 24 V DC, st<strong>and</strong>ard 6ES7 131-4BD00-0AA0<br />

DI 2 x 24 V DC, High Feature;<br />

with diagnostics<br />

- Short-circuit monitoring<br />

6ES7 131-4BB00-0AB0<br />

DI 4 x 24 V DC, High Feature;<br />

with diagnostics<br />

- Short-circuit monitoring<br />

6ES7 131-4BD00-0AB0<br />

DI 4 x 24...48 V AC/DC, High<br />

Feature; with diagnostics<br />

- Wire break monitoring (external<br />

resistor circuit required)<br />

- Monitoring of the fuse<br />

- Monitoring of the load voltage<br />

6ES7 131-4CD00-0AB0 B)<br />

DI 2 x 120 V AC, st<strong>and</strong>ard 6ES7 131-4EB00-0AB0 B)<br />

DI 2 x 230 V AC, st<strong>and</strong>ard<br />

Failsafe Digital Input<br />

6ES7 131-4FB00-0AB0 B)<br />

4/8 F-DI 24 V DC PROFIsafe<br />

8 DI safety-oriented SIL-2 or 4 DI<br />

safety-oriented SIL-3, with diagnostics<br />

- Cyclic short-circuit test<br />

- Discrepancy monitoring of 2<br />

channels for SIL 3 (adjustable<br />

discrepancy time)<br />

- Safe monitoring of communication<br />

with PROFIsafe<br />

Digital Outputs for direct voltage<br />

(suitable for solenoid<br />

valves, DC contactors, indicator<br />

lights etc.)<br />

6ES7 138-4FA01-0AB0<br />

DO 2 x 24 V DC/0.5 A, st<strong>and</strong>ard 6ES7 132-4BB00-0AA0<br />

DO 2 x 24 V DC/2 A, st<strong>and</strong>ard 6ES7 132-4BB30-0AA0<br />

DO 2 x 24 V DC/0.5 A, High Feature,<br />

with diagnostics<br />

- Connection of a default value<br />

by channel in the event of CPU<br />

failure (parameterizable)<br />

- Short-circuit monitoring by<br />

channel<br />

- Broken wire monitoring by<br />

channel (when "1" signal)<br />

6ES7 132-4BB00-0AB0<br />

DO 2 x 24 V DC/2 A, High Feature,<br />

with diagnostics<br />

- Connection of a default value<br />

by channel in the event of CPU<br />

failure (parameterizable)<br />

- Short-circuit monitoring by<br />

channel<br />

- Broken wire monitoring by<br />

channel (when "1" signal)<br />

6ES7 132-4BB30-0AB0 B)<br />

DO 4 x 24 V DC/0.5 A, st<strong>and</strong>ard 6ES7 132-4BD00-0AA0 B)<br />

DO 4 x 24 V DC/2 A, st<strong>and</strong>ard 6ES7 132-4BD30-0AA0<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

Digital output for AC voltage<br />

(suitable for solenoid valves,<br />

AC contactors, indicator lights<br />

etc.)<br />

DO 2 x 24...230 V AC, 2 A<br />

- Connection of a default value<br />

by channel in the event of CPU<br />

failure (parameterizable)<br />

Relay output (suitable for<br />

AC/DC solenoid valves, contactors,<br />

motor starters, miniature<br />

motors <strong>and</strong> indicator lights)<br />

2 x relays 24...230 V AC/DC, 5 A<br />

- Connection of a default value<br />

by channel in the event of CPU<br />

failure (parameterizable)<br />

Failsafe Digital Output<br />

4 F-DO 24 V DC/2 A PROFISafe<br />

safety-oriented up to SIL-3, with<br />

diagnostics, PM switching<br />

- Short-circuit monitoring by<br />

channel<br />

- Overload monitoring by channel<br />

- Broken wire monitoring by<br />

channel (when "1" signal)<br />

- Safe monitoring of communication<br />

with PROFIsafe<br />

- Diagnostics inside module<br />

Process I/O<br />

ET 200S distributed I/O<br />

Digital electronic modules<br />

6ES7 132-4FB00-0AB0 B)<br />

6ES7 132-4HB00-0AB0<br />

6ES7 138-4FB01-0AB0<br />

B) Subject to export regulations: AL: N, ECCN: EAR99H<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

11/29<br />

11


11<br />

Process I/O<br />

ET 200S distributed I/O<br />

Analog electronic modules<br />

■ Overview<br />

Analog inputs <strong>and</strong> outputs for the ET 200S<br />

Can be connected to TM-E terminal modules with automatic<br />

coding<br />

High-feature variants with enhanced accuracy <strong>and</strong> resolution<br />

Hot swapping of modules<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

Analog Input<br />

AI 2xU (±5 V, 1...5V, ±10 V) /<br />

13 bit, st<strong>and</strong>ard<br />

- Diagnostics inside module<br />

- Overflow/underflow diagnostics<br />

AI 2xI, 2-wire MU (4...20 mA) /<br />

13 bit, st<strong>and</strong>ard<br />

- Diagnostics inside module<br />

- Overflow/underflow diagnostics<br />

- Wire break monitoring<br />

AI 2xI, 4-wire MU (±20 mA,<br />

4...20 mA) / 13 bit, st<strong>and</strong>ard<br />

- Diagnostics inside module<br />

- Overflow/underflow diagnostics<br />

- Wire break monitoring<br />

AI 2xTC / 15 bit, st<strong>and</strong>ard<br />

- Diagnostics inside module<br />

- Overflow/underflow diagnostics<br />

- Wire break monitoring<br />

- Compensation through external<br />

Pt100 in the same station<br />

with AI 2xRTD St<strong>and</strong>ard<br />

AI 2xRTD / 15 bit, st<strong>and</strong>ard<br />

- Diagnostics inside module<br />

- Overflow/underflow diagnostics<br />

- Wire break monitoring<br />

- Pt100 resistance thermometer,<br />

Ni100 (2, 3 or 4 wires)<br />

AI 2xU (1...5 V, ±5 V, ±10 V) /<br />

15 bit, high resolution<br />

- Diagnostics inside module<br />

- Overflow/underflow diagnostics<br />

AI 2xI (±20 mA, 4...20 mA) /<br />

15 bit, high resolution<br />

- Diagnostics inside module<br />

- Overflow/underflow diagnostics<br />

- Wire break monitoring<br />

AI 2xTC / 15 bit, High Feature<br />

- Diagnostics inside module<br />

- Overflow/underflow diagnostics<br />

- Wire break monitoring<br />

- Internal temperature compensation<br />

with TM-E15S24-AT or<br />

TM-E15C24-AT terminal module<br />

AI 2xRTD / 15 bit, High Feature<br />

- Diagnostics inside module<br />

- Overflow/underflow diagnostics<br />

- Wire break monitoring<br />

- Resistance thermometer<br />

Pt100/200/500/1,000,<br />

Ni100/1,000 (2, 3 or 4 wires)<br />

- Temperature in Celsius or<br />

Fahrenheit<br />

11/30<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

6ES7 134-4FB00-0AB0 B)<br />

6ES7 134-4GB00-0AB0 B)<br />

6ES7 134-4GB10-0AB0 B)<br />

6ES7 134-4JB00-0AB0 B)<br />

6ES7 134-4JB50-0AB0 B)<br />

6ES7 134-4LB00-0AB0 B)<br />

6ES7 134-4MB00-0AB0 B)<br />

6ES7 134-4NB00-0AB0 B)<br />

6ES7 134-4NB50-0AB0 B)<br />

■ Selection <strong>and</strong> Ordering Data<br />

Analog Output<br />

Order No.<br />

AO 2xU (1...5 V / 12 bit, ±10 V /<br />

13 bit), st<strong>and</strong>ard<br />

- Diagnostics inside module<br />

- Parameterizable connection of<br />

a default value in case of CPU<br />

stop<br />

- Short-circuit monitoring<br />

6ES7 135-4FB00-0AB0 B)<br />

AO 2xI (±20 mA, 4...20 mA) /<br />

13 bit, st<strong>and</strong>ard<br />

- Diagnostics inside module<br />

- Parameterizable connection of<br />

a default value in case of CPU<br />

stop<br />

- Wire break monitoring<br />

6ES7 135-4GB00-0AB0<br />

6ES7 135-4LB00-0AB0<br />

B)<br />

AO 2xU (1...5 V, ±10 V) / 15 bit,<br />

high resolution<br />

- Diagnostics inside module<br />

- Parameterizable connection of<br />

a default value in case of CPU<br />

stop<br />

- Short-circuit monitoring<br />

AO 2xI (±20 mA, 4...20 mA) /<br />

15 bit, high resolution<br />

- Diagnostics inside module<br />

- Parameterizable connection of<br />

a default value in case of CPU<br />

stop<br />

- Wire break monitoring<br />

6ES7 135-4MB00-0AB0<br />

B) Subject to export regulations: AL: N, ECCN: EAR99H


■ Overview<br />

Completely prewired motor starter for the switching <strong>and</strong> safeguarding<br />

of any three-phase current loads<br />

Optionally available as direct, reversing or soft starter<br />

High Feature motor starter with combination of motor circuit<br />

protector, electronic overload protection <strong>and</strong> contactor or soft<br />

starter up to 7.5 kW<br />

Failsafe motor starters based on the High Feature micro starters<br />

with integrated redundancy also offer shut-down reliability<br />

up to Category 4 (EN 954-1)<br />

With build-as-you-go 40/50 A power bus, i.e. once-only incoming<br />

supply of load voltage for a group of motor starters<br />

Hot swapping permissible<br />

Inputs <strong>and</strong> outputs for controlling <strong>and</strong> signalizing states already<br />

integrated<br />

Diagnostics-capable for active monitoring of the protection<br />

<strong>and</strong> switching function<br />

Combinable with expansion modules: Brake control module<br />

for operating electromechanical brakes in three-phase AC<br />

motors, <strong>and</strong> with two optional inputs for special functions<br />

■ Selection <strong>and</strong> Ordering Data<br />

High Feature Motor Starter<br />

With diagnostics, unfused;<br />

exp<strong>and</strong>able with brake control<br />

module<br />

DS1e-x Direct Starter<br />

Direct starter; mechanical switching;<br />

electronic UE protection<br />

Order No.<br />

up to 1.1 kW/400 V; 0.3..0.3.0 A 3RK1 301-0AB10-0AA3<br />

up to 3.0 kW/400 V; 2.4..00.8.0 A 3RK1 301-0BB10-0AA3<br />

up to 7.5 kW/400 V;<br />

2.4..00.16.0 A<br />

DSS1e-x Soft Starter<br />

Direct soft starter; electronic<br />

switching; electronic UE protection<br />

3RK1 301-0CB10-0AA3<br />

up to 1.1 kW/400 V; 0.3..0.3.0 A 3RK1 301-0AB20-0AA3<br />

up to 3.0 kW/400 V; 2.4..00.8.0 A 3RK1 301-0BB20-0AA3<br />

up to 7.5 kW/400 V;<br />

2.4..00.16.0 A<br />

RS1e-x Reversing Starter<br />

Reversing starter; mechanical<br />

switching; electronic UE protection<br />

3RK1 301-0CB20-0AA3 F)<br />

up to 1.1 kW/400 V; 0.3..0.3.0 A 3RK1 301-0AB10-1AA3<br />

up to 3.0 kW/400 V; 2.4..00.8.0 A 3RK1 301-0BB10-1AA3<br />

up to 7.5 kW/400 V;<br />

2.4..00.16.0 A<br />

3RK1 301-0CB10-1AA3<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

Accessories for Motor Starter<br />

High Feature<br />

Terminal module<br />

TM-DS65-S32<br />

for DS1e-x, DSS1e-x direct starters<br />

with supply connection for<br />

power bus incl. 3 caps for terminating<br />

the power bus<br />

TM-DS65-S31<br />

for DS1e-x, DSS1e-x direct starters<br />

without supply connection<br />

for power bus<br />

TM-RS130-S32<br />

for RS1e-x reversing starter with<br />

supply connection for power<br />

bus incl. 3 caps for connecting<br />

the power bus<br />

TM-RS130-S31<br />

for RS1e-x reversing starter without<br />

supply connection for power<br />

bus<br />

Jumper Modules<br />

M15-PEN<br />

15 mm wide, for jumpering a<br />

15-mm module<br />

M30-PEN<br />

30 mm wide, for jumpering a<br />

30-mm module<br />

M15-L123<br />

15 mm wide, for jumpering a<br />

15-mm module<br />

M30-L123<br />

30 mm wide, for jumpering a<br />

30-mm module<br />

2DI 24 V DC control module<br />

Digital input module with two<br />

inputs for local motor starter functions<br />

for mounting on the front of<br />

the motor starter<br />

M65-PEN-F Feeder Block<br />

65 mm wide, incl. two caps,<br />

in combination with TM-DS65-<br />

32/TM-RS130-S32<br />

M65-PEN-S Connection Module<br />

65 mm wide, in combination with<br />

TM-DS65-31/TM-RS130-S31<br />

Brake Control Expansion Module<br />

For motors with mechanical brake<br />

xB1<br />

24 V DC / 4 A<br />

xB2<br />

500V DC / 0.7A<br />

xB3<br />

24 V DC / 4 A, DI 2 x 24 V DC local<br />

control<br />

xB4<br />

500 V DC/ 0.7 A, DI 2 x 24 V DC<br />

local control<br />

Terminal Modules for Brake<br />

Control Expansion Module<br />

TM-xB15 S24-01<br />

for xB1 or xB2<br />

TM-xB215 S24-01<br />

for xB1 ... 4<br />

Process I/O<br />

ET 200S distributed I/O<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

Motor starters<br />

3RK1 903-0AK00 F)<br />

3RK1 903-0AK10 F)<br />

3RK1 903-0AL00 F)<br />

3RK1 903-0AL10 F)<br />

3RK1 903-0AH00<br />

3RK1 903-0AJ00<br />

3RK1 903-0AE00<br />

3RK1 903-0AF00<br />

3RK1 903-0CH10<br />

3RK1 903-2AC00<br />

3RK1 903-2AC10<br />

3RK1 903-0CB00 F)<br />

3RK1 903-0CC00 F)<br />

3RK1 903-0CE00 F)<br />

3RK1 903-0CF00 F)<br />

3RK1 903-0AG00<br />

3RK1 903-0AG01 F)<br />

11/31<br />

11


11<br />

Process I/O<br />

ET 200S distributed I/O<br />

Motor starters<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

Motor Starter Failsafe<br />

Unfused; exp<strong>and</strong>able with brake<br />

control module; High Feature;<br />

for PM-D F PROFIsafe power<br />

module<br />

F-DS1e-x Failsafe Direct Starter<br />

up to 1.1 kW/400 V; 0.3..0.3.0 A 3RK1 301-0AB13-0AA2<br />

up to 3.0 kW/400 V; 2.4..00.8.0 A 3RK1 301-0BB13-0AA2<br />

up to 7.5 kW/400 V;<br />

3RK1 301-0CB13-0AA2<br />

2.4..00.16.0 A<br />

F-RS1e-x Failsafe Reversing<br />

Starter<br />

up to 1.1 kW/400 V; 0.3..0.3.0 A 3RK1 301-0AB13-1AA2<br />

up to 3.0 kW/400 V; 2.4..00.8.0 A 3RK1 301-0BB13-1AA2<br />

up to 7.5 kW/400 V;<br />

3RK1 301-0CB13-1AA2<br />

2.4..00.16.0 A<br />

Brake Control Module<br />

For motors with mechanical brake<br />

xB3<br />

24 V DC / 4 A, DI 2 x 24 V DC local<br />

control<br />

xB4<br />

500 V DC/ 0.7 A, DI 2 x 24 V DC<br />

local control<br />

11/32<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

3RK1 903-0CE00 F)<br />

3RK1 903-0CF00 F)<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

Accessories for Motorstarter<br />

Failsafe<br />

Terminal module<br />

PM-D F PROFIsafe 3RK1 903-3AA00 F)<br />

PM-D F X1, incoming supply<br />

on left<br />

PM-D F X1, incoming supply in<br />

center<br />

3RK1 903-3AE00 F)<br />

3RK1 903-3AE10 F)<br />

For contact multipliers 3RK1 903-3AB10<br />

For F-DS1e-x, with supply connection<br />

For F-DS1e-x, without supply<br />

connection<br />

For F-RS1e-x, with supply connection<br />

For F-RS1e-x, without supply<br />

connection<br />

M65-PEN-F Feeder Block<br />

65 mm wide, incl. two caps,<br />

in combination with TM-DS65-<br />

32/TM-RS130-S32<br />

M65-PEN-S Connection Module<br />

65 mm wide, in combination with<br />

TM-DS65-31/TM-RS130-S31<br />

3RK1 903-3AC00 F)<br />

3RK1 903-3AC10 F)<br />

3RK1 903-3AD00 F)<br />

3RK1 903-3AD10 F)<br />

3RK1 903-2AC00<br />

3RK1 903-2AC10<br />

F) Subject to export regulations: AL: N, ECCN: EAR99


■ Overview<br />

The SIGUARD safety system is based on special terminal <strong>and</strong><br />

power modules that can be combined with the ET 200S motor<br />

starters <strong>and</strong> a failsafe kit to achieve the highest safety category<br />

4 (according to EN 954-1). It enables the evaluation of emergency<br />

stop circuits, the monitoring of protective doors or the implementation<br />

of time-delayed shut-downs. The costs involved in<br />

the configuration <strong>and</strong> wiring of conventional safety systems are<br />

no longer incurred. All st<strong>and</strong>ard safety applications can be covered<br />

with SIGUARD (see the ET 200S manual for examples of<br />

applications).<br />

■ Design<br />

Terminal modules for SIGUARD power modules<br />

The terminal modules integrate the SIGUARD power modules.<br />

Using different terminal modules it is possible to separate various<br />

safety circuits by function or cascade them. Each group of<br />

this type has to be terminated with a SIGUARD PM-X connection<br />

module.<br />

The TM-PF30 S47-B1 terminal module always st<strong>and</strong>s at the<br />

beginning of a safety segment <strong>and</strong> integrates either the PM-<br />

DF1 power module for emergency stop applications or the<br />

PM-DF2 power module for protective door monitoring. The 2channel<br />

connection of the safety sensor (e.g. emergency stop<br />

sensor) as well as the 24-V supplies for the electronics (U1 )<br />

<strong>and</strong> the contactors (U2 ) of the motor starters have to be connected<br />

to this terminal module. Connections for the ON button<br />

(enable) <strong>and</strong> the safe output of the power module are also<br />

available.<br />

The TM-PF30 S47-B0 terminal module is used for the cascading<br />

of subordinate safety segments <strong>and</strong> integrates either the<br />

PM-D F1 power module for emergency stop applications or<br />

the PM-D F2 power module for protective door monitoring. No<br />

additional auxiliary voltage has to be connected to this terminal<br />

module. The supply is fed through the terminal module<br />

voltage buses from the preceding PM-D F1 or PM-D F2 power<br />

module. Switching off the voltage of the preceding power<br />

module means that the terminal module has no voltage either.<br />

The TM-PF30 S47-C1 terminal module always st<strong>and</strong>s at the<br />

beginning of an expansion of a safety segment in a new station,<br />

e.g. in an interlaced configuration. It integrates the PM-D<br />

F3 power module for time-delayed shut-down or the PM-D F4<br />

power module for direct shut-down in physically separated<br />

ET 200S stations. The 24 V supplies for the electronics (U1)<br />

<strong>and</strong> for the contactors (U2) are fed in anew. The shut-down<br />

comm<strong>and</strong> of a preceding ET 200S station is integrated<br />

through a safe input. Separate terminals are available for connecting<br />

the feedback circuit to the upstream ET 200S station.<br />

It is not possible to connect safety sensors to this terminal<br />

module.<br />

The TM-PF30 S47-C0 terminal module is used for the cascading<br />

of subordinate safety segments <strong>and</strong> integrates either the<br />

PM-D F3 power module for time-delayed shut-down or the PM-<br />

D F4 power module. Only the U2 supply voltage has to be connected<br />

to this terminal module. The U1 supply is fed through<br />

the terminal module voltage buses of the preceding power<br />

module (voltage group section). It is not possible to connect<br />

safety sensors to this terminal module.<br />

The TM-PF30 S47-D0 terminal module is used to integrated<br />

the PM-D F5 power module. At this terminal module it is possible<br />

to forward safe signals to external systems through four<br />

groups, each with two safety relay contacts in redundant configuration.<br />

The terminal module must always be positioned between<br />

one of the afore-mentioned terminal modules <strong>and</strong> a terminal<br />

module for the TM-X connection module. It is not<br />

possible to connect safety sensors to this terminal module<br />

Process I/O<br />

ET 200S distributed I/O<br />

SIGUARD safety engineering<br />

TM-X terminal module for SIGUARD connection module<br />

For connecting an external incoming supply contactor (second<br />

shut-down option) in category 3 <strong>and</strong> 4. The SIGUARD connection<br />

module is inserted to the right of the last motor starter in a<br />

safety segment. The terminals for connecting the positively<br />

driven NC contact of the contactor are located along side the terminals<br />

for connecting the contactor coil likewise on the TM-X terminal<br />

module. If no redundant contactor is required in<br />

category 2 (EN 954-1), for example, the feedback circuit has to<br />

be closed at these terminals with a jumper. This arrangement is<br />

also used instead of SIGUARD power module as an interface to<br />

the external safety relay when external safety relays are used.<br />

SIGUARD PM-D F1/F2/F3/F4/F5 power modules<br />

Following SIGUARD PM-D power modules are available for selection:<br />

PM-D F1 for evaluating emergency stop circuits with the function<br />

"monitored start&#147;<br />

PM-D F2 for monitoring protective doors with the function "automatic<br />

start"<br />

PM-D F3 as PM-D F1/F2 expansion for time-delayed shutdown<br />

PM-D F4 for exp<strong>and</strong>ing safety circuits with other ET 200S motor<br />

starters, e.g. in another row<br />

PM-D F5 for transmitting the status of PM-D F1...4 over four<br />

floating release circuits to external safety devices (contact<br />

multipliers)<br />

No additional PM-S power module is required when using the SI-<br />

GUARD power modules. SIGUARD PM-D F1/F2/F3/F4 power<br />

modules monitor auxiliary voltages <strong>and</strong> contain the complete<br />

functionality of a safety relay. The PM-D F1 <strong>and</strong> PM-D F2 modules<br />

can be combined with the PM-D F3 or PM-D F4 modules. A<br />

PM-D F5 can be arranged in any position between PM-D F1...4<br />

<strong>and</strong> a PM-X.<br />

Every safety circuit, starting with a PM-D F1 ... 4, has to be terminated<br />

with a PM-X.<br />

Failsafe kit<br />

Every st<strong>and</strong>ard motor starter in a safety segment has to be supplemented<br />

with the failsafe kit (F-kit) in order to monitor the<br />

switching function. F-kit 1 supplements the DS1-x direct starter,<br />

F-kit 2 supplements the RS1-x reversing starter.<br />

The F-kits comprise<br />

Contact carriers for the terminal modules,<br />

one or two auxiliary switch blocks for the contactor / contactors<br />

of the motor starter, <strong>and</strong><br />

connecting cables.<br />

High Feature motor starters <strong>and</strong> their terminal modules come<br />

equipped with the F-kit functions.<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

11/33<br />

11


11<br />

Process I/O<br />

ET 200S distributed I/O<br />

SIGUARD safety engineering<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

SIGUARD Terminal Modules<br />

PM-PF30 S47 B1<br />

Terminal Module<br />

For PM-D F1/2 power modules<br />

with U1/U2 incoming supply <strong>and</strong><br />

sensor connection<br />

PM-PF30 S47 B0<br />

Terminal Module<br />

For PM-D F1/2 power modules<br />

with sensor connection<br />

PM-PF30 S47 C1<br />

Terminal Module<br />

For PM-D F3/4 power modules<br />

with U1/U2 incoming supply <strong>and</strong><br />

IN+/IN- control input<br />

PM-PF30 S47 C0<br />

Terminal Module<br />

For PM-D F3/4 power modules<br />

with U2 incoming supply<br />

PM-PF30 S47 D0<br />

Terminal Module<br />

For PM-D F5 power modules<br />

PM-X15 S27 01<br />

Terminal Module<br />

For SIGUARD connection module<br />

SIGUARD Power Modules<br />

PM-D F1 SIGUARD<br />

Power Module<br />

EMERGENCY STOP; monitored<br />

start; 2-channel<br />

PM-D F2 SIGUARD<br />

Power Module<br />

Protective door; autostart;<br />

2-channel<br />

PM-D F3 SIGUARD<br />

Power Module<br />

Expansion to F1/2 for an additional<br />

voltage group; timedelayed<br />

PM-D F4 SIGUARD<br />

Power Module<br />

Expansion to F1/2 for an additional<br />

voltage group<br />

PM-D F5 SIGUARD<br />

Power Module<br />

Expansion to PM-D F1 up to<br />

PM-D F4, contact multiplier<br />

11/34<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

3RK1 903-1AA00 F)<br />

3RK1 903-1AA10 F)<br />

3RK1 903-1AC00 F)<br />

3RK1 903-1AC10<br />

3RK1 903-1AD10<br />

3RK1 903-1AB00 F)<br />

3RK1 903-1BA00<br />

3RK1 903-1BB00<br />

3RK1 903-1BD00<br />

3RK1 903-1BC00<br />

3RK1 903-1BE00<br />

■ Selection <strong>and</strong> Ordering Data<br />

Accessories<br />

Order No.<br />

PM-X SIGUARD<br />

Connection module for incomingfeeder<br />

contactor; external safety<br />

circuits<br />

3RK1 903-1CB00 F)<br />

Failsafe kit 1<br />

Failsafe kit for DS1-x st<strong>and</strong>ard<br />

motor starter (not necessary for<br />

High Feature motor starter)<br />

3RK1 903-1CA00 F)<br />

Failsafe kit 2<br />

Failsafe kit for RS1-x st<strong>and</strong>ard<br />

motor starter (not necessary for<br />

High Feature motor starter)<br />

3RK1 903-1CA01 F)<br />

F) Subject to export regulations: AL: N, ECCN: EAR99


Migration to<br />

SIMATIC PCS 7<br />

12/2 Migration TELEPERM M<br />

12/2 Introduction<br />

12/4 OS Migration from TELEPERM M<br />

12/8 AS Migration from TELEPERM M<br />

12/10 Migration APACS+<br />

12/10 Introduction<br />

12/11 PCS 7/APACS+ ES Software<br />

12/12 PCS 7/APACS+ OS Software<br />

12/13 Migration SIMATIC PCS/TISTAR<br />

12/13 Migration of SIMATIC PCS / TISTAR<br />

systems with 505 controllers<br />

12/14 PCS 7/505 ES Software<br />

12/15 PCS 7/505 OS Software<br />

<strong>Siemens</strong> ST PCS 7 · October 2004


12<br />

Migration to SIMATIC PCS 7<br />

Migration TELEPERM M<br />

Introduction<br />

■ Overview<br />

The TELEPERM ® M process control system from <strong>Siemens</strong> has<br />

proven itself worldwide in many different industry sectors in the<br />

past 20 years. More than 15,000 installed systems have proven<br />

their performance, reliability <strong>and</strong> user-friendliness in many years<br />

of service, even under extreme operating conditions.<br />

Many users are faced with the need to adapt their production operations<br />

to market requirements, which means having to exp<strong>and</strong><br />

or modernize their plants.<br />

SIMATIC PCS 7, the succesor generation for the process control<br />

system, was introduced by <strong>Siemens</strong> in 1997 for new plants <strong>and</strong><br />

plant expansions, <strong>and</strong> offers an open platform for modern, forward-looking<br />

<strong>and</strong> economical automation solutions in all industries.<br />

The installed platform of the old process control system represents<br />

an immense investment in hardware <strong>and</strong> application software<br />

as well as a wealth of valuable <strong>and</strong> complex know-how accumulated<br />

by operating <strong>and</strong> maintenance personnel.<br />

The objective of the migration is to modernize the existing platform<br />

step-by-step without changing the system, <strong>and</strong> at the same<br />

time to guarantee past investments for as long as possible. For<br />

this purpose, <strong>Siemens</strong> has been offering optimized migration solutions<br />

for the transition from TELEPERM M to SIMATIC PCS 7<br />

since 1996. The range of migration products covers hardware<br />

<strong>and</strong> software components as well as services for converting application<br />

software, on-site conversions, <strong>and</strong> the migration of<br />

complete systems.<br />

2/2<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

At the beginning, the main migration of customers was the stepby-step<br />

modernization <strong>and</strong> functional expansion of individual<br />

components of the existing TELEPERM M systems:<br />

Replacement of existing automation systems by future-compatible<br />

automation systems under the premise of importing<br />

existing application software <strong>and</strong> TELEPERM M I/O.<br />

Replacement of operation <strong>and</strong> monitoring systems by operator<br />

systems on the basis of SIMATIC PCS 7<br />

Integration of the distributed SIMATIC process I/Os<br />

Customers are increasingly choosing a more direct migration of<br />

TELEPERM M to SIMATIC PCS 7. They are selecting the full<br />

range of SIMATIC system components, which have been proven<br />

worldwide. They therefore benefit from the characteristics of a<br />

modern process control system <strong>and</strong> the synergies of TIA, <strong>and</strong><br />

are able at the same time to continue using their existing<br />

TELEPERM M I/Os. <strong>Siemens</strong> supports this trend by means of<br />

new migration products as well as optimized services <strong>and</strong> inhouse<br />

tools for hardware <strong>and</strong> software conversion.<br />

With the modern, pioneering SIMATIC PCS 7 process control<br />

system, innovative migration solutions <strong>and</strong> services, many years<br />

of know-how in process control engineering <strong>and</strong> migration, as<br />

well as worldwide servicing, <strong>Siemens</strong> demonstrates its expertise<br />

in the process control engineering field <strong>and</strong> offers the security of<br />

a reliable partner.


■ Options<br />

Migration Services<br />

For a migration project to succeed it is not enough just to have a<br />

technical solution that is optimally adapted to the customer ’s<br />

needs <strong>and</strong> the individual conditions of the plant in question.<br />

Equally important is the fast <strong>and</strong> punctual implementation of this<br />

solution at a high level of quality.<br />

We thus offer you not only services for single phases of the migration<br />

process, e.g. AS conversion with retention of the<br />

TELEPERM M I/Os or substitution of the operator systems incl.<br />

conversion of your user software, but also for the complete migration<br />

of your plant - all from one source.<br />

Our migration specialists are familiar with the systems technology<br />

behind TELEPERM M <strong>and</strong> SIMATIC PCS 7 <strong>and</strong> have many<br />

years of experience in engineering, commissioning <strong>and</strong> service.<br />

They will inform you about the migration options available, analyze<br />

your plant, provide you with individual consulting <strong>and</strong>, finally,<br />

draw up a detailed quotation for your migration project.<br />

Short stoppage times call for exact planning, which is why our<br />

migration specialists join you in organizing <strong>and</strong> coordinating the<br />

smooth performance of all the activities itemized in the quotation.<br />

The user software is the know-how medium <strong>and</strong> embodies a<br />

large part of the overall investment volume. Hence the quality of<br />

its conversion into the new system world is a key criterion for a<br />

migration’s economic efficiency. The modern conversion tools<br />

that we developed ourselves enable the conversion work to proceed<br />

quickly <strong>and</strong> reliably, <strong>and</strong> guarantee software of constant<br />

quality, reliability <strong>and</strong> verifiability. All the conversion steps performed<br />

are documented, as are the manual reconfigurations required<br />

in special cases.<br />

Finally, we will draw up detailed documentation of your plant as<br />

soon as the re-start is completed. We even see to the proper disposal<br />

of any replaced system components.<br />

Contact address for information, consulting, analysis <strong>and</strong> quotations:<br />

<strong>Siemens</strong> AG<br />

Uwe Skoeries<br />

Tel.: +49 721 595-8789<br />

Fax: +49 721 595-5121<br />

E-mail: uwe.skoeries@siemens.com<br />

Migration to SIMATIC PCS 7<br />

Migration TELEPERM M<br />

■ More information<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

Introduction<br />

You can find further information, order data <strong>and</strong> technical data<br />

on the various migration products for TELEPERM M in the following<br />

sections "OS Migration from TELEPERM M" <strong>and</strong> "AS Migration<br />

from TELEPERM M" as well as in the catalog PLT 112 or<br />

CA 01 under "Process Control <strong>System</strong> TELEPERM M".<br />

More migration products can also be found in the catalog ST<br />

PCS 7.A (Add Ons for the SIMATIC PCS 7 Process Control <strong>System</strong>).<br />

Additional information is available in the Internet under:<br />

http://www.siemens.com/teleperm<br />

2/3<br />

12


12<br />

Migration to SIMATIC PCS 7<br />

Migration TELEPERM M<br />

OS Migration TELEPERM M<br />

■ Overview<br />

The PCS7/TM-OS operator systems offered here can be used for<br />

the migration of older TELEPERM M operator systems. This is<br />

simply done by replacing the OS 252, OS 26x or OS 52x operator<br />

systems already installed in existing TELEPERM M<br />

plants/plant units with the SIMATIC PCS 7 operator systems,<br />

which are designed for connection to the TELEPERM M plant<br />

bus CS 275.<br />

As explained in the previous section, The PCS 7/TM OS operator<br />

system with double channel functionality, which is designed to<br />

be operated simultaneously on the TELEPERM M plant bus<br />

CS 275 <strong>and</strong> the PCS 7 plant bus, can be used in combination<br />

with the GT104CS gateway (SIMATIC PCS 7 add-on product,<br />

see the ST PCS 7.A catalog). The effective connection of existing<br />

TELEPERM M plant units with SIMATIC PCS 7 plant units is<br />

thus possible. The cross-bus communication load can be skilfully<br />

shared using this combination. While the PCS 7/TM-OS operator<br />

system with double channel functionality sees to AS-OS<br />

communication with the automation systems on the two plant<br />

buses CS 275 <strong>and</strong> Industrial Ethernet <strong>and</strong> to time synchronization<br />

for the TELEPERM M subplant, the cross-bus AS-AS communication<br />

takes place through the GT104CS gateway.<br />

The PCS7/TM-OS operator systems can be used as display <strong>and</strong><br />

control components for TELEPERM M automation systems<br />

AS 215,<br />

AS 220 S, AS 220 K, AS 220 H,<br />

AS 230, AS 230 K,<br />

AS 235, AS 235 K, AS 235 H,<br />

AS 388/TM <strong>and</strong> AS 488/TM as well as<br />

SIMATIC S5-150U/S5-155U on the CS 275 plant bus.<br />

This basic hardware available as single station systems, servers<br />

<strong>and</strong> clients for PCS 7/TM-OS may be exp<strong>and</strong>ed with the following<br />

options, depending on their use <strong>and</strong> the defined scope of<br />

supply:<br />

PCS 7 OS Software,<br />

components for connecting to the TELEPERM M plant bus<br />

CS 275 (interface module, local bus connecting cable <strong>and</strong><br />

PCS 7/TM-OS coupling package),<br />

signal module <strong>and</strong><br />

PCS 7/TM-OCX (NORA) program package.<br />

Also relevant for the configuration of PCS 7/TM-OS are the additional/expansion<br />

components, multi-VGA graphics cards, monitors<br />

<strong>and</strong> chipcard readers available for St<strong>and</strong>ard PCS 7 OS (see<br />

the sections "ES/OS/Batch/IT basic devices" <strong>and</strong> "Administration"<br />

in the chapter "<strong>System</strong> Neutral Components"). OS options<br />

such as redundancy <strong>and</strong> signal output (see the section "OS<br />

hardware" in the chapter "Operator <strong>System</strong>") are also useful.<br />

2/4<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

■ Function<br />

Coupling packages for PCS 7/TM-OS V3.0<br />

With the coupling packages for PCS 7/TM-OS it is possible for<br />

the self-configured operator systems to exchange information<br />

with automation systems on the CS 275 plant bus. They contain<br />

a bus-specific channel DLL <strong>and</strong> a TM Manager. The channel<br />

DLL adapts the TELEPERM M frames to the OS-specific data<br />

structures <strong>and</strong> procedures by converting the protocol. The TM<br />

Manager is a configuration assistant that supports the following<br />

configuration functions:<br />

ORPA Import<br />

The ORPA Import function creates (in the operator system) for<br />

TELEPERM M st<strong>and</strong>ard <strong>and</strong> user blocks structured variables<br />

in accordance with the AS data defined in the PROGRAF AS+<br />

configuration tool. The selection of parameters to be imported<br />

can be modified using filters <strong>and</strong> a dialog box.<br />

Block Import<br />

The Block Import function creates (in the operator system) for<br />

TELEPERM M st<strong>and</strong>ard <strong>and</strong> user block instances of the block<br />

types defined in PROGRAF AS+. The selection of parameters<br />

to be imported can be modified using filters <strong>and</strong> a dialog box.<br />

Connection Import<br />

The Connection Import function generates connections in the<br />

TELEPERM M channel CS 275. Flags can be set for transmitting<br />

status signals or plain-text messages, <strong>and</strong> for loading<br />

onto the corresponding automation system.<br />

Signal Generator<br />

The Signal Generator function determines the block instances<br />

which were imported into the operator system <strong>and</strong> generates<br />

signals for said instances in the AlarmLogging. The message<br />

texts can be parameterized. Signal class <strong>and</strong> signal type can<br />

be bit-specifically defined for MKS blocks.<br />

Batch Import<br />

The Batch Import function merges the SIMATIC BATCH-specific<br />

configuration in the SIMATIC Manager <strong>and</strong> in<br />

TELEPERM M <strong>and</strong> prepares the data for the SIMATIC BATCH<br />

data household.<br />

The coupling packages for PCS 7/TM-OS are available in<br />

3 different versions depending on the lower-level TELEPERM M<br />

automation systems:<br />

AS23x/ASx88<br />

for the systems AS 215, AS 230, AS 230 K, AS 235, AS 235 K,<br />

AS 235 H, AS 388/TM, AS 488/TM, <strong>and</strong> for SIMATIC S5-<br />

150U/S5-155U<br />

AS220<br />

for the systems AS 220 S, AS 220 K, AS 220 H<br />

AS220/AS23x/ASx88<br />

for all the previously listed systems<br />

Coupling package upgrade to PCS 7/TM-OS V3.0<br />

An upgrade package that also includes the PCS 7/TM-OCX program<br />

package is available to upgrade existing WinCC/TM V1.0x<br />

or PCS 7/TM-OS V2.x coupling packages. One upgrade package<br />

is required for each PCS 7/TM-OS single station system, operator<br />

terminal or server. The order number of the upgrade must<br />

be selected according to the installed platform (type of PCS<br />

7/TM-OS coupling package <strong>and</strong>/or PCS 7/TM-OCX (NORA) program<br />

package).


PCS 7/TM-OCX (NORA) Program Package V3.0<br />

Faceplate (here for the RN block) in the TELEPERM M NORA display (left)<br />

<strong>and</strong> the PCS 7 layout (right)<br />

The PCS 7/TM-OCX (NORA) program package comprises:<br />

Faceplates for the st<strong>and</strong>ardized display of operable<br />

TELEPERM M AS function blocks in various hierarchy levels<br />

(symbol display/group display/loop display)<br />

Faceplates for the visualization of PCS 7 driver blocks of the<br />

TELEPERM M I/Os<br />

The faceplates for the AS st<strong>and</strong>ard function blocks are comparable<br />

with the st<strong>and</strong>ardized displays of the TELEPERM M operator<br />

system OS 525 or with the layout of PCS 7 process displays.<br />

They are of multi-lingual design, i.e. the user can choose between<br />

the languages German, English <strong>and</strong> French. The related<br />

electronic documentation is supplied on CD in German <strong>and</strong> English.<br />

Process connection takes place by linking the faceplate to the<br />

AS st<strong>and</strong>ard function block. The Object Control ActiveX (OCX)<br />

interactive graphics element performs the logic operation with<br />

the process variables.<br />

As a result, the PCS7/TM-OCX (NORA) program package not<br />

only makes the configuration of pictures easier, it also does<br />

much to simplify <strong>and</strong> speed up the entire OS configuration process.<br />

For some AS st<strong>and</strong>ard function blocks the PCS 7/TM-OCX<br />

(NORA) program package offers not only faceplates in the<br />

PCS 7 layout but also faceplates in the TELEPERM M NORA presentation.<br />

Both faceplate types can be used simultaneously on<br />

the same computer. However, you can use the displays of only<br />

one block type for the function "Select display using measuring<br />

point".<br />

Migration to SIMATIC PCS 7<br />

Migration TELEPERM M<br />

OS Migration TELEPERM M<br />

OS <strong>Engineering</strong> Bundle for TM Migration<br />

The PCS 7/TM-OS coupling package for AS 23x/488 <strong>and</strong> the<br />

PCS 7 <strong>Engineering</strong> Software OS for 2,000 POs/RC 64K are available<br />

as economical preferred versions in the bundle<br />

"OS <strong>Engineering</strong> for TELEPERM M Migration". The benefits are<br />

felt above all by customers who are using a PCS 7/TM-OS operator<br />

system for the first time <strong>and</strong> need to create the necessary<br />

engineering conditions to do so.<br />

The number of configurable process objects <strong>and</strong> variables can<br />

be increased further by means of add-on PCS 7 <strong>Engineering</strong><br />

Power Packs if required.<br />

The bundle "OS <strong>Engineering</strong> for TELEPERM M Migration&#147;<br />

can also be used together with the SIMATIC PCS 7/TM-<br />

OS Server IL 40 S V2 BCE <strong>and</strong> the PROGRAF AS+/NT program<br />

package listed in the "Selection <strong>and</strong> ordering data" to configure<br />

an AS/OS <strong>Engineering</strong> Station for subsystems networked by the<br />

CS 275 plant bus. In case of direction migration to SIMATIC<br />

PCS 7, during which existing TELEPERM M automation systems<br />

are replaced by PCS 7 automation systems upon receiving the<br />

TELEPERM M I/Os, the engineering station can be extended in<br />

addition with PCS 7 <strong>Engineering</strong> Software AS. The bus interface<br />

for the PCS 7 Industrial Ethernet plant bus, which is required for<br />

ES-AS communication, is already included in the SIMATIC<br />

PCS 7/TM-OS Server IL 40 S V2 BCE.<br />

■ Integration<br />

Connecting systems with TELEPERM M basic functions to<br />

SIMATIC BATCH V6.0<br />

Using the coupling packages for PCS 7/TM-OS it is possible to<br />

connect AS 23x or AS 488/TM automation systems, whose functional<br />

process areas are automated with GF blocks of the basic<br />

functions program package in version V1.3 <strong>and</strong> lower<br />

(6DS5305-8AA; released for delivery in 08/89), to SIMATIC<br />

BATCH V6.0. Connection takes place through the UNIB, TR1B<br />

<strong>and</strong> EM1B interface blocks, which are inserted in the AS structure.<br />

The interface blocks enable SIMATIC BATCH to dock on in<br />

order to forward modes of operation, setpoint values <strong>and</strong> phase<br />

change comm<strong>and</strong>s to the basic function, <strong>and</strong> to read its status.<br />

Each interface block on the AS side is assigned an equivalent<br />

SIMATIC BATCH inteface block in the CFC, which is visible in the<br />

variable household of PCS 7 operator systems.<br />

The double channel functionality also supports connection to SI-<br />

MATIC BATCH, i.e. plant units can be used by different systems<br />

within a recipe. It is irrelevant for the recipe whether a plant unit<br />

is on a SIMATIC PCS 7 automation system or on a TELEPERM M<br />

automation system.<br />

Converting existing user software<br />

The user software is the know-how medium <strong>and</strong> embodies a<br />

large part of the overall investment volume. We provide you,<br />

therefore, with the fast <strong>and</strong> reliable conversion of your user software<br />

for use on the new system platform. In doing so we make<br />

allowance for sector-specific properties as well as special plant<br />

solutions. Using tools that we developed ourselves we guarantee<br />

software of constant quality, reliablity <strong>and</strong> verifiability. All the<br />

conversion steps performed are documented, as are the manual<br />

reconfigurations required in special cases.<br />

Contact address for quotations <strong>and</strong> more information:<br />

<strong>Siemens</strong> AG<br />

Uwe Skoeries<br />

Tel.: +49 721 595-8789<br />

Fax: +49 721 595-5121<br />

E-mail: uwe.skoeries@siemens.com<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

2/5<br />

12


12<br />

Migration to SIMATIC PCS 7<br />

Migration TELEPERM M<br />

OS Migration TELEPERM M<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

Single station<br />

Complies with St<strong>and</strong>ard PCS 7 Single Station, see the chapter<br />

"ES/OS/BATCH/IT basic devices"<br />

PCS 7 ES/OS IL 40 S V2 BCE<br />

with SIMATIC PC in rack of<br />

19" design, Pentium 4 with<br />

2.8 GHz <strong>and</strong> more, 1 Gbyte RAM<br />

(2 x 512 Mbyte), sound, EIDE-<br />

RAID 1 with 2 hard disks of<br />

120 Gbyte, graphics controller on<br />

board with Dynamic Video Memory,<br />

DVD±RW IDE, optical mouse,<br />

2x FastEthernet RJ45 (on board<br />

for connection to OS-LAN/terminal<br />

bus + PCI card for double<br />

channel mode),<br />

without monitor, keyboard <strong>and</strong><br />

printer,<br />

Windows 2000 Professional MUI<br />

(German, English, French, Italian,<br />

Spanish)<br />

PCS 7 OS Software Single Station<br />

preinstalled <strong>and</strong> on restore DVD,<br />

but without authorization<br />

Other items required:<br />

interface module for CS 275 incl.<br />

local bus connecting cable,<br />

PCS 7 OS Software Single Station<br />

(for authorization),<br />

PCS 7/TM-OS coupling package,<br />

optional: signal module,<br />

PCS 7/TM-OCX (NORA)<br />

Note:<br />

the coupling package for<br />

PCS 7/TM-OS <strong>and</strong> PCS 7/TM-<br />

OCX (NORA) are not preinstalled<br />

(unlike on the OS Server)<br />

6ES7 650-0GC06-0YX0 D)<br />

2/6<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

■ Selection <strong>and</strong> Ordering Data<br />

Server<br />

SIMATIC PCS 7/TM-OS Server<br />

IL40 S V2 BCE<br />

SIMATIC PC in rack of 19" design,<br />

Pentium 4 with 2.8 GHz <strong>and</strong> more,<br />

1 Gbyte RAM (2 x 512 Mbyte),<br />

sound, EIDE-RAID 1 with 2 hard<br />

disks of 120 Gbyte, graphics controller<br />

on board with Dynamic<br />

Video Memory, DVD-ROM IDE,<br />

2 x Fast Ethernet RJ45 (on board<br />

for connection to OS-LAN/terminal<br />

bus + PCI card for double<br />

channel operation), interface<br />

module for CS 275, optical<br />

mouse, without monitor, keyboard<br />

<strong>and</strong> printer,<br />

Windows 2000 Professional MUI<br />

(German, English, French, Italian,<br />

Spanish)<br />

PCS 7 OS Software Server,preinstalled<br />

<strong>and</strong> on restore DVD but<br />

without authorization<br />

Coupling package for PCS 7/TM-<br />

OS <strong>and</strong> PCS 7/TM-OCX (NORA)<br />

preinstalled but without authorization<br />

Descriptions of coupling<br />

package for PCS 7/TM-OS <strong>and</strong><br />

PCS 7/TM-OCX (NORA) preinstalled<br />

as PDF file (German <strong>and</strong><br />

English)<br />

Instruction manual of the interface<br />

module for CS 275 is provided as<br />

a PDF file on CD (German <strong>and</strong><br />

English)<br />

Order No.<br />

Without signal module 6DL2 207-1CA D)<br />

With signal module<br />

Other items required:<br />

local bus connecting cable,<br />

PCS 7 OS Software Server <strong>and</strong><br />

coupling package for PCS 7/TM-<br />

OS (each for authorization);<br />

optional when there is a process<br />

visualization module on the server:<br />

PCS 7/TM-OCX (NORA)<br />

Client<br />

6DL2 207-1DA D)<br />

Complies with St<strong>and</strong>ard PCS 7 Client, see the chapter "ES/OS/BATCH/IT<br />

basic devices"<br />

PCS 7 OS Client IL 40 S V2<br />

SIMATIC PC in rack of 19“ design,<br />

Pentium 4 with 2.8 GHz <strong>and</strong> more,<br />

512 Mbyte RAM (2 x 256 Mbyte),<br />

EIDE hard disk of 80 Gbyte,<br />

graphics controller on board with<br />

Dynamic Video Memory, DVD-<br />

ROM IDE, optical mouse,Fast Ethernet<br />

RJ45 on board for connection<br />

to OS-LAN, without monitor,<br />

keyboard <strong>and</strong> printer,<br />

Windows 2000 Professional MUI<br />

(German, English, French, Italian,<br />

Spanish)<br />

PCS 7 OS Software Client preinstalled<br />

<strong>and</strong> on restore DVD, but<br />

without authorization<br />

Other items required:<br />

PCS 7 OS Software Client (for<br />

authorization),<br />

optional: signal module,<br />

PCS 7/TM-OCX (NORA)<br />

Note:<br />

PCS 7/TM-OCX (NORA) is not<br />

preinstalled (unlike on the<br />

OS Server)<br />

6ES7 650-0GD06-0YX0 D)


■ Selection <strong>and</strong> Ordering Data Order No.<br />

Additional <strong>and</strong> expansion components<br />

Hardware Coupling Package for<br />

CS 275<br />

Comprising an interface module<br />

for CS 275, 2.5-m local bus connecting<br />

cable, documentation<br />

(German or English)<br />

Coupling packages for<br />

PCS 7/TM-OS V3.0<br />

On request<br />

PCS 7/TM-OS Coupling Package<br />

for AS 23x/AS x88<br />

bilingual (German, English)<br />

Type of delivery: Certificate of license<br />

<strong>and</strong> authorization diskette;<br />

software <strong>and</strong> electronic<br />

documentation on CD<br />

6DS5 140-1AX A)<br />

PCS 7/TM-OS Coupling Package<br />

for AS 220<br />

bilingual (German, English)<br />

Type of delivery: Certificate of license<br />

<strong>and</strong> authorization diskette;<br />

software <strong>and</strong> electronic<br />

documentation on CD<br />

6DS5 140-1BX A)<br />

PCS 7/TM-OS Coupling Package<br />

for AS 220/AS 23x/AS x88<br />

bilingual (German, English)<br />

Type of delivery: Certificate of license<br />

<strong>and</strong> authorization diskette;<br />

software <strong>and</strong> electronic<br />

documentation on CD<br />

6DS5 140-1CX A)<br />

PCS 7/TM-OCX (NORA) Program<br />

Package V3.0<br />

St<strong>and</strong>ardized displays for operable<br />

TELEPERM M AS function<br />

blocks <strong>and</strong> for PCS 7 driver<br />

blocks of the TELEPERM M I/Os,<br />

trilingual (German, English,<br />

French)<br />

type of delivery: Certificate of<br />

license <strong>and</strong> authorization diskette;<br />

electronic documentation<br />

(German, English) <strong>and</strong> software<br />

on CD<br />

Note:<br />

When the PCS 7/TM-OCX (NORA)<br />

is used, a 6DS5 034-1AX program<br />

package has to be ordered<br />

for each single-user system (OS<br />

Single Station) <strong>and</strong> for each operator<br />

terminal (OS Client) of a<br />

multi-user system. A program<br />

package is also required for the<br />

process visualization module if it<br />

is used on the server.<br />

6DS5 034-1AX A)<br />

Migration to SIMATIC PCS 7<br />

Migration TELEPERM M<br />

OS Migration TELEPERM M<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

OS <strong>Engineering</strong> Bundle for<br />

TM Migration<br />

Comprising:<br />

PCS 7/TM-OS coupling package<br />

for AS 23x/488, order No.<br />

6DS5 140-1AX, <strong>and</strong><br />

PCS 7 <strong>Engineering</strong> Software OS<br />

for 2,000 POs/RC 64K, order<br />

No. 6ES7 658-2DB06-0YA0<br />

6DL5 200-1AX00-0XA0 C)<br />

Coupling package upgrade to<br />

PCS 7/TM-OS V3.0<br />

Comprising software CD <strong>and</strong>:<br />

without authorization for process<br />

coupling <strong>and</strong> PCS 7/TM-OCX<br />

Authorization for PCS 7/TM-OS<br />

AS23x/ASx88 coupling package<br />

Authorization for PCS 7/TM-OS<br />

AS220 coupling package<br />

Authorization for PCS 7/TM-OS<br />

AS220/AS23x/ASx88 coupling<br />

package<br />

A) Subject to export regulations: AL: N, ECCN: 5D992B2<br />

C) Subject to export regulations: AL: N, ECCN: EAR99S<br />

D) Subject to export regulations: AL: N, ECCN: 5D992B1<br />

Other additional/expansion components such as utility software, power<br />

cables, signal modules, multi-VGA graphics cards, OS redundancy components,<br />

chipcard readers, memory expansions, keyboards or monitors<br />

can be found in the sections "ES/OS/BATCH/IT basic devices" <strong>and</strong> "Administration"<br />

in the chapter "<strong>System</strong> Neutral Components", in the chapter<br />

"ES/OS/BATCH/IT basic devices" or in the section "OS hardware" in the<br />

chapter "Operator <strong>System</strong>". The PCS 7 OS software required for use as a<br />

single station, server or client can be found in the section "OS software".<br />

■ More information<br />

6DS5 128-1XX00-2XX4 A)<br />

6DS5 128-1XX40-2XX4 A)<br />

6DS5 128-1XX50-2XX4 A)<br />

6DS5 128-1XX60-2XX4 A)<br />

Authorization for PCS 7/TM-OCX 6DS5 128-1XX02-2XX4 A)<br />

Authorization for PCS 7/TM-OS<br />

AS23x/ASx88 coupling package<br />

<strong>and</strong> PCS 7/TM-OCX<br />

6DS5 128-1XX42-2XX4 A)<br />

Authorization for PCS 7/TM-OS<br />

AS220 coupling package <strong>and</strong><br />

PCS 7/TM-OCX<br />

6DS5 128-1XX52-2XX4 A)<br />

Authorization for PCS 7/TM-OS<br />

AS220/AS23x/ASx88 coupling<br />

package <strong>and</strong> PCS 7/TM-OCX<br />

6DS5 128-1XX62-2XX4 A)<br />

Customized special configurations for TELEPERM M operator<br />

systems PCS 7/TM-OS<br />

On request:<br />

<strong>Siemens</strong> Karlsruhe<br />

Tel.: +49 721 595-4272 or -3776<br />

Fax: +49 721 595-6525<br />

E-mail:<br />

gerhard.kuhn@siemens.com<br />

helmut.heib@siemens.com<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

2/7<br />

12


12<br />

Migration to SIMATIC PCS 7<br />

Migration TELEPERM M<br />

AS Migration from TELEPERM M<br />

■ Overview<br />

The process I/Os of existing plants with their extensive wiring<br />

<strong>and</strong> routing, large stock of I/O modules, power supply units,<br />

cabinets <strong>and</strong> sometimes Ex isolating devices represent, together<br />

with the plant’s documentation <strong>and</strong> the maintenance personnel’s<br />

know-how, a highly valuable asset. Plant managers are<br />

often concerned, therefore, to preserve <strong>and</strong> use these resources<br />

for as long as possible.<br />

They are supported in this endeavor in excellent manner by the<br />

PCS 7/TM I/O migration package <strong>and</strong> by the services which are<br />

offered in this connection for the on-site conversion of the AS as<br />

well as implementation of the user’s TELEPERM M automation<br />

system structure in a SIMATIC PCS 7 structure.<br />

The PCS 7/TM I/O migration package unites a SIMATIC PCS 7<br />

automation system with the components required for connecting<br />

the TELEPERM I/Os in a MIG II migration rack. This migration<br />

rack provides in addition 5 slots for TELEPERM I/O modules <strong>and</strong><br />

replaces the module rack with CPU in the TELEPERM M basic<br />

cabinet of the automation system that is undergoing the migration.<br />

The SIMATIC PCS 7 automation system needs suitable driver<br />

blocks in order to address the TELEPERM I/O modules. A library<br />

with these driver blocks <strong>and</strong> an S7 object manager for the hardware<br />

configuration in HW Config are supplied with the PCS 7/TM<br />

I/O migration package.<br />

The different versions of the PCS 7/TM I/O migration package<br />

are referred to below as AS 414-3 TM I/O, AS 416-2 TM I/O <strong>and</strong><br />

AS 416-3 TM I/O depending on the type of automation system.<br />

2/8<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

■ Integration<br />

Migratable TELEPERM I/O modules<br />

The spectrum of TELEPERM I/O modules that can be operated<br />

on SIMATIC PCS 7 automation systems covers all module types<br />

that have been released for the TELEPERM M automation system<br />

AS 488/TM. An overview is available as a configuration list<br />

on the Internet pages of TELEPERM M under Support -> Info<br />

Material -> Configuration of I/Os.<br />

Additional information is available in the Internet under:<br />

http://www.siemens.com/teleperm<br />

AS migration with retention of the TELEPERM I/Os / conversion<br />

of existing user software<br />

Our migration specialists will join you in drawing up an optimum<br />

migration solution for your requirements <strong>and</strong> the technical conditions<br />

of your plant. We provide services for single phases of<br />

the migration process, e.g. AS conversion with retention of the<br />

TELEPERM M I/Os, in addition to the complete migration of your<br />

plant - all from one source.<br />

And we can also provide you with the fast <strong>and</strong> reliable conversion<br />

of your user software for use on the new system platform. In<br />

doing so we make allowance for sector-specific properties as<br />

well as special plant solutions. Using tools that we developed<br />

ourselves we guarantee software of constant quality, reliablity<br />

<strong>and</strong> verifiability. All the conversion steps performed are documented,<br />

as are the manual reconfigurations required in special<br />

cases.<br />

Contact address for quotations <strong>and</strong> more information:<br />

<strong>Siemens</strong> AG<br />

Uwe Skoeries<br />

Tel.: +49 721 595-8789<br />

Fax: +49 721 595-5121<br />

E-mail: uwe.skoeries@siemens.com


■ Selection <strong>and</strong> Ordering Data Order No.<br />

Ordering units for automation systems (preferred configurations)<br />

AS 414-3 TM I/O automation<br />

system<br />

Comprising:<br />

MIG II migration rack with slots for<br />

5 TELEPERM M I/O modules,<br />

CPU 414-3 with 3 interfaces<br />

(MPI/DP, DP <strong>and</strong> slot for<br />

IF module),<br />

1.4 Mbyte main memory<br />

(0.7 Mbyte each for program <strong>and</strong><br />

data) <strong>and</strong> 2 Mbyte RAM memory<br />

card, 2 backup batteries,<br />

CP 443-1 communications module<br />

for connection to Industrial<br />

Ethernet plant bus,<br />

FM 456-4 function module with<br />

8 MByte memory expansion <strong>and</strong><br />

5V Flash-EPROM 8 Mbyte memory<br />

card,<br />

TPM 478-2 interface module for<br />

TELEPERM M I/O bus A <strong>and</strong> B,<br />

software CD with PCS 7 driver<br />

block library for TELEPERM M I/O<br />

modules, operating software for<br />

FM 456-4, S7 object manager,<br />

M7-SYS Realtime V4.0 <strong>and</strong> documentation<br />

for PCS 7/TM I/O in<br />

PDF format (German, English)<br />

PS 405 power supply; 20 A, for<br />

24 V DC<br />

6DL2 100-1AJ30 A)<br />

PS 405 power supply; 10 A for<br />

24 V DC<br />

AS 416-2 TM I/O automation<br />

system<br />

Comprising:<br />

MIG II migration rack with slots for<br />

5 TELEPERM M I/O modules,<br />

CPU 416-2 with 2 interfaces<br />

(MPI/DP <strong>and</strong> DP),<br />

2.8 Mbyte main memory<br />

(1.4 Mbyte each for program <strong>and</strong><br />

data) <strong>and</strong> 4 Mbyte RAM memory<br />

card, 2 backup batteries,<br />

CP 443-1 communications module<br />

for connection to Industrial<br />

Ethernet plant bus,<br />

FM 456-4 function module with<br />

8 MByte memory expansion <strong>and</strong><br />

5V Flash-EPROM 8 Mbyte memory<br />

card,<br />

TPM 478-2 interface module for<br />

TELEPERM M I/O bus A <strong>and</strong> B,<br />

software CD with PCS 7 driver<br />

block library for TELEPERM M I/O<br />

modules, operating software for<br />

FM 456-4, S7 object manager,<br />

M7-SYS Realtime V4.0 <strong>and</strong> documentation<br />

for PCS 7/TM I/O in<br />

PDF format (German, English)<br />

6DL2 100-1BJ30 A)<br />

PS 405 power supply; 20 A, for<br />

24 V DC<br />

6DL2 100-1AK30 A)<br />

PS 405 power supply; 10 A for<br />

24 V DC<br />

6DL2 100-1BK30 A)<br />

Migration to SIMATIC PCS 7<br />

Migration TELEPERM M<br />

AS Migration from TELEPERM M<br />

■ Selection <strong>and</strong> Ordering Data<br />

AS 416-3 TM I/O automation<br />

system<br />

Comprising:<br />

MIG II migration rack with slots for<br />

5 TELEPERM M I/O modules,<br />

CPU 416-3 with 3 interfaces<br />

(MPI/DP, DP <strong>and</strong> slot for<br />

IF module),<br />

5.6 Mbyte main memory<br />

(2.8 Mbyte each for program <strong>and</strong><br />

data) <strong>and</strong> 8 Mbyte RAM memory<br />

card, 2 backup batteries,<br />

CP 443-1 communications module<br />

for connection to Industrial<br />

Ethernet plant bus,<br />

FM 456-4 function module with<br />

8 MByte memory expansion <strong>and</strong><br />

5V Flash-EPROM 8 Mbyte memory<br />

card,<br />

TPM 478-2 interface module for<br />

TELEPERM M I/O bus A <strong>and</strong> B,<br />

software CD with PCS 7 driver<br />

block library for TELEPERM M I/O<br />

modules, operating software for<br />

FM 456-4, S7 object manager,<br />

M7-SYS Realtime V4.0 <strong>and</strong> documentation<br />

for PCS 7/TM I/O in<br />

PDF format (German, English)<br />

Order No.<br />

PS 405 power supply; 20 A, for<br />

24 V DC<br />

6DL2 100-1AL30 A)<br />

PS 405 power supply; 10 A for<br />

24 V DC<br />

6DL2 100-1BL30 A)<br />

Individual components for automation systems<br />

See ordering data for accessories<br />

for st<strong>and</strong>ard automation systems<br />

in the section "<strong>Automation</strong> <strong>System</strong>s"<br />

In addition for AS 414-3 TM I/O,<br />

AS 416-2 TM I/O <strong>and</strong><br />

AS 416-3 TM I/O:<br />

PCS 7/TM I/O coupling package<br />

Comprising:<br />

TPM 478-2 interface module<br />

Software CD with PCS 7 driver<br />

block library for TELEPERM M<br />

I/O modules, operating software<br />

for FM 456-4, S7 object manager<br />

<strong>and</strong> M7-SYS Realtime V4.0<br />

Documentation for 7/TM I/O in<br />

PDF format (German, English)<br />

Product information<br />

IF 961-DI0 Interface Module<br />

Digital I/O for controlling the cabinet<br />

lamp<br />

Still available for TELEPERM M<br />

migration, order no. 6ES7 961-<br />

1AA00-0AC0<br />

6ES7 478-2DA10-0AC0<br />

A) Subject to export regulations: AL: N, ECCN: 5D992B2<br />

Note :<br />

The PCS 7/TM-OCX (NORA) program package provides suitable faceplates<br />

for visualization of the PCS 7/TM I/O driver blocks (see the section<br />

"Operator <strong>System</strong> - OS Migration“).<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

2/9<br />

12


12<br />

Migration to SIMATIC PCS 7<br />

Migration APACS+<br />

Introduction<br />

■ Overview<br />

The APACS+ process control system has been used successfully<br />

world-wide for over 10 years. Its functionality, reliability <strong>and</strong><br />

user-friendliness have been demonstrated in more than<br />

10,000 installed systems. In the meantime industry regulations<br />

have become more stringent <strong>and</strong> the dem<strong>and</strong>s of industrial production<br />

more exacting.<br />

A study of APACS+ systems used in the manufacturing sector indicated<br />

that the dem<strong>and</strong>s made of the HMI level (operator system)<br />

have gone up by a disproportionate amount compared to<br />

the controller <strong>and</strong> I/O level. As the result, an operator system<br />

(OS) installed four years ago is no longer able to satisfy today’s<br />

st<strong>and</strong>ards <strong>and</strong> has to be brought up to the current state of the art<br />

using modern technology. <strong>Automation</strong> systems (AS) have a far<br />

longer useful life by comparison.<br />

An installed APACS+ system represents an immense investment<br />

in hardware <strong>and</strong> application software as well as a wealth of valuable<br />

know-how accumulated by operating <strong>and</strong> maintenance<br />

personnel; selective migration through modernization of the operator<br />

system <strong>and</strong> engineering systems without changing the existing<br />

controller <strong>and</strong> I/O level system thus offers a welcome opportunity<br />

to protect a great deal of your past investment for as<br />

long as possible.<br />

A suitable open system platform for this purpose is available<br />

from <strong>Siemens</strong> in the form of its modern, pioneering SIMATIC<br />

PCS 7 process control system.<br />

Migration to SIMATIC PCS 7 technology can increase the functionality<br />

<strong>and</strong> performance of an APACS+ process control system<br />

by a significant amount. And APACS+ customers benefit in addition<br />

from continuous further development <strong>and</strong> long-term global<br />

service for the installed APACS+ base as well as from the advantages<br />

to be gained from TIA (Totally Integrated <strong>Automation</strong>) <strong>and</strong><br />

SIMATIC IT. This shortens the time to market, protects existing investments<br />

<strong>and</strong> increases plant productivity.<br />

2/10<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

■ Design<br />

Different migration products are available for migration of<br />

APACS+ <strong>System</strong>s:<br />

PCS 7/APACS+ OS <strong>Engineering</strong> Pack<br />

for <strong>Engineering</strong> of the OS <strong>and</strong> for OS connection to APACS+<br />

<strong>and</strong>/or QUADLOG Controllers<br />

PCS 7/APACS+ ES Libraries option package<br />

for <strong>Engineering</strong> of the PCS 7 ES <strong>and</strong> OS using APACS+ style<br />

process automation templates (function blocks, symbols <strong>and</strong><br />

faceplates) for connection to SIMATIC S7 Controllers<br />

PCS 7/APACS+ OS software packages<br />

for Operation <strong>and</strong> Monitoring of APACS+ <strong>and</strong>/or QUADLOG<br />

Controllers using PCS 7 OS (single stations or client/server<br />

systems)<br />

PCS 7/APACS+ SIMATIC BATCH products for ES <strong>and</strong> OS<br />

for engineering, operation <strong>and</strong> control of Batch processes using<br />

SIMATIC BATCH connected to APACS+ Controllers


■ Design<br />

The following ES software products are available for migration to<br />

SIMATIC PCS 7 technology <strong>and</strong> can be applied to either Batch<br />

or Continuous applications:<br />

Required<br />

Software Products<br />

PCS 7/APACS+ OS<br />

<strong>Engineering</strong> Pack<br />

V6.0<br />

PCS 7/APACS+ ES<br />

Libraries V6.0<br />

PCS 7/APACS+<br />

SIMATIC BATCH DBA<br />

<strong>Engineering</strong> V6.0<br />

Batch Application Continuous Application<br />

APACS+ /QUADLOG<br />

Controller<br />

X X<br />

X<br />

AS 41x<br />

(S7-400<br />

Controller)<br />

X<br />

Migration to SIMATIC PCS 7<br />

Migration APACS+<br />

PCS 7/APACS+ ES Software<br />

PCS 7/APACS+ SIMATIC BATCH DBA <strong>Engineering</strong> V6.0 option<br />

package<br />

for <strong>Engineering</strong> of PCS 7 OS <strong>and</strong> SIMATIC BATCH to connect<br />

with APACS+ Controllers<br />

This optional package extends the PCS 7/APACS+ OS DBA software<br />

application so that it can populate the OS database with<br />

batch interface information <strong>and</strong> create the file that contains the<br />

process model information used by SIMATIC BATCH.<br />

Migration to SIMATIC BATCH enables you to take advantage of<br />

advanced features like:<br />

one time configuration of equipment information,<br />

easy graphical recipe creation,<br />

ability to define when to start <strong>and</strong> stop batch related continuous<br />

data collection, <strong>and</strong><br />

to define the execution order of batches by chaining the<br />

batches.<br />

PowerPacks <strong>and</strong> additional engineering software can be selected<br />

from the Section "ES software" of Chapter "<strong>Engineering</strong> ■ Selection <strong>and</strong> Ordering Data Order No.<br />

system".<br />

PCS 7/APACS+ OS <strong>Engineering</strong> 6EQ2 000-2EB06-3BA0 C)<br />

PCS 7/APACS+ OS <strong>Engineering</strong> Pack V6.0<br />

Pack V6.0<br />

RC 64K process variables, incl.<br />

for OS connection to APACS+ <strong>and</strong>/or QUADLOG Controllers 512 archive variables<br />

The software package consists of:<br />

Single license for 1 installation,<br />

English<br />

PCS 7 <strong>Engineering</strong> Software (64K variables, incl. 512 archive Electronic documentation on the<br />

variables)<br />

CD "PCS 7/APACS+ Options<br />

PCS 7/APACS+ OS DBA software application<br />

Version 6.0" <strong>and</strong> the PCS 7<br />

Toolset CDs<br />

Channel DLL for communication with APACS+/QUADLOG<br />

controllers<br />

Type of delivery:<br />

Certificate of license <strong>and</strong> autho-<br />

The core component of PCS 7/APACS+ OS engineering is the rization diskette<br />

PCS 7/APACS+ OS DBA (Database <strong>Automation</strong>) software appli- PCS 7 Toolset CDs <strong>and</strong> additioncation.<br />

It automatically generates the OS database with the real CDs with Service Pack for Miquired<br />

variables, display hierarchies, specific block symbols<br />

<strong>and</strong> faceplates directly from the APACS+/QUADLOG controller.<br />

The display hierarchies are used to automatically create a navigation<br />

system for movement between process graphics within<br />

the operator station. PCS 7/APACS+ OS DBA automatically positions<br />

the type-specific block symbols, e.g. controllers or anacrosoft<br />

Windows 2000 (5<br />

languages), Microsoft Internet<br />

Explorer, Microsoft SQL Server<br />

2000 <strong>and</strong> PC Anywhere<br />

CD "PCS 7/APACS+ Options<br />

Version 6.0"<br />

log inputs (AI), in the generated process displays. These sym- PCS 7/APACS+ ES Libraries 6EQ2 000-1AX06-2BC0 C)<br />

bols are linked to the corresponding function blocks <strong>and</strong><br />

faceplates via the database. The manual configuration activities<br />

are basically limited to the design <strong>and</strong> positioning of static<br />

graphic elements, e.g. pipes or tanks.<br />

V6.0<br />

Single license for 1 installation,<br />

English<br />

Electronic documentation on the<br />

CD "PCS 7/APACS+ Options<br />

PCS 7/APACS+ ES Libraries V6.0 option package<br />

Version 6.0"<br />

for <strong>Engineering</strong> of the PCS 7 ES <strong>and</strong> OS using APACS+ style pro-<br />

Type of delivery:<br />

cess automation templates (function blocks, symbols <strong>and</strong> face- Certificate of license<br />

plates) for use in SIMATIC S7-400 Controllers (AS 41x)<br />

CD "PCS 7/APACS+ Options<br />

This option package for the PCS 7 engineering software includes:<br />

an ES library with preconfigured PID, motor <strong>and</strong> valve controllers<br />

for SIMATIC S7-400 controllers as well as<br />

Version 6.0"<br />

PCS 7/APACS+ SIMATIC BATCH<br />

DBA <strong>Engineering</strong> V6.0<br />

Single license for 1 installation,<br />

English<br />

6EQ2 000-5XX06-2BD0 C)<br />

corresponding block symbols <strong>and</strong> faceplates for the PCS 7 Type of delivery:<br />

operator system.<br />

Certificate of license <strong>and</strong> autho-<br />

This library is designed to copy the functionality of the APACS+<br />

rization diskette<br />

Basic Application Library allowing it to be used in AS 41x automation<br />

systems. Thus AS 41x automation systems can be operated<br />

<strong>and</strong> displayed as well as APACS+/QUADLOG controllers.<br />

C) Subject to export regulations: AL: N, ECCN: EAR99S<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

2/11<br />

12


12<br />

Migration to SIMATIC PCS 7<br />

Migration APACS+<br />

PCS 7/APACS+ OS Software<br />

■ Overview<br />

The PCS 7/APACS+ operator system is based on SIMATIC<br />

PCS 7 st<strong>and</strong>ard components: OS clients, OS servers,<br />

OS redundant servers, OS single stations <strong>and</strong> archive servers.<br />

The OS migration packages PCS 7/APACS+ OS are adapted to<br />

these system components <strong>and</strong> include not only the PCS 7 OS<br />

software for one OS single station, one OS server or two redundant<br />

servers but also the corresponding software for OS communication<br />

with the APACS+ automation systems through the<br />

MBI/MNET communication module.<br />

Similarly, in a batch application, the architecture will be augmented<br />

with batch clients, <strong>and</strong> batch servers. Batch clients may<br />

be on the same SIMATIC PCS 7 basic units as the OS clients or<br />

may be on separate basic units. Except for all-in-one systems,<br />

batch servers are usually on basic units separate from OS servers.<br />

SIMATIC BATCH servers always communicate to APACS+ controllers<br />

through PCS 7/APACS+ OS Servers. The PCS 7/APACS+<br />

SIMATIC BATCH Runtime license enables SIMATIC BATCH to<br />

exchange runtime information with an APACS+ controller<br />

through an OS server or OS single station via the<br />

APACS+/QUADLOG Communication Channel DLL. One license<br />

is needed for each OS server or OS single station that is used to<br />

exchange data with SIMATIC BATCH. For this reason, the<br />

PCS 7/APACS+ SIMATIC BATCH Runtime license is loaded on<br />

each OS server <strong>and</strong> OS single station. For architectures utilizing<br />

a OS single station, SIMATIC BATCH <strong>and</strong> PCS 7 OS must be executing<br />

on the same basic unit (all-in-one).<br />

2/12<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

■ Design<br />

The following OS software packages are required depending<br />

on the configuration of a SIMATIC PCS 7 basic unit as a<br />

PCS 7/APACS+ OS Single Station, PCS 7/APACS+ OS Server<br />

(single or redundant) or PCS 7/APACS+ OS Client. The PCS<br />

7/APACS+ OS software packages for OS Servers <strong>and</strong> OS Single<br />

Stations include the channel dll for communicating with the<br />

APACS+ controllers (APACS <strong>and</strong> QUADLOG) through the<br />

MBI/MNET communications module. If SIMATIC BATCH is used,<br />

the PCS 7/APACS+ SIMATIC BATCH Runtime V6.0 option will<br />

also be needed on each PCS 7/APACS+ OS Server <strong>and</strong> PCS<br />

7/APACS+ OS Single Station that contains batch data.<br />

Required Software<br />

Packages<br />

Architecture<br />

PCS 7/ PCS 7/APACS+ PCS 7/<br />

APACS+ OS Server<br />

APACS+<br />

OS Single<br />

Station<br />

single redundant<br />

OS Client<br />

PCS 7/APACS+ OS<br />

Single Station Pack<br />

V6.0 (PO 2000/RT<br />

64K)<br />

1<br />

PCS 7/APACS+ OS<br />

Server Pack V6.0<br />

(PO 2000/RT 64K)<br />

PCS 7/APACS+ OS<br />

Redundant Server<br />

Pack V6.0 (PO<br />

2000/RT 64K)<br />

PCS 7 OS Client<br />

(see Section "OS<br />

software" in chapter<br />

"Operator system")<br />

Required for use<br />

with SIMATIC<br />

BATCH:<br />

PCS 7/APACS+<br />

SIMATIC BATCH<br />

Runtime license<br />

V6.0<br />

Power Packs <strong>and</strong> additional software for SIMATIC PCS 7 operator<br />

systems can be selected from the Section "OS software" of<br />

Chapter "Operator system".<br />

1<br />

1 1 2<br />

1<br />

1


■ Selection <strong>and</strong> Ordering Data Order No.<br />

PCS 7/APACS+ OS Server Pack<br />

V6.0<br />

2000 PO/RT 64K process variables,<br />

incl. 512 archive variables<br />

Single license for 1 installation,<br />

English<br />

Electronic documentation on the<br />

CD "PCS 7/APACS+ Options<br />

Version 6.0" <strong>and</strong> the PCS 7<br />

Toolset CDs<br />

Type of delivery:<br />

Certificate of license <strong>and</strong> authorization<br />

diskette<br />

PCS 7 Toolset CDs <strong>and</strong> additional<br />

CDs with Service Pack for<br />

Microsoft Windows 2000<br />

(5 languages), Microsoft Internet<br />

Explorer, Microsoft SQL<br />

Server 2000 <strong>and</strong> PC Anywhere<br />

CD "PCS 7/APACS+ Options<br />

Version 6.0"<br />

6EQ2 000-2BB06-3BA0 C)<br />

PCS 7/APACS+ OS Redundant<br />

Server Pack V6.0<br />

2000 PO/RT 64K process variables,<br />

incl. 512 archive variables<br />

Single license for 2 installations,<br />

English, incl. WinCC/Redundancy<br />

<strong>and</strong> RS 232 connecting<br />

cable, 10 m<br />

Electronic documentation on the<br />

CD "PCS 7/APACS+ Options<br />

Version 6.0" <strong>and</strong> the PCS 7<br />

Toolset CDs<br />

Type of delivery:<br />

2 certificates of license <strong>and</strong><br />

2 authorization diskettes<br />

PCS 7 Toolset CDs <strong>and</strong> additional<br />

CDs with Service Pack for<br />

Microsoft Windows 2000 (5 languages),<br />

Microsoft Internet Explorer,<br />

Microsoft SQL Server<br />

2000 <strong>and</strong> PC Anywhere;<br />

WinCC/Redundancy incl. RS<br />

232 connecting cable, 10 m<br />

CD "PCS 7/APACS+ Options<br />

Version 6.0"<br />

6EQ2 000-2DB06-3BA0 C)<br />

Migration to SIMATIC PCS 7<br />

Migration APACS+<br />

PCS 7/APACS+ OS Software<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

PCS 7/APACS+ OS Single Station<br />

Pack V6.0<br />

2000 PO/RT 64K process variables,<br />

incl. 512 archive variables<br />

Single license for 1 installation,<br />

English<br />

Electronic documentation on the<br />

CD "PCS 7/APACS+ Options<br />

Version 6.0" <strong>and</strong> the PCS 7<br />

Toolset CDs<br />

Type of delivery:<br />

Certificate of license, authorization<br />

diskette<br />

PCS 7 Toolset CDs <strong>and</strong> additional<br />

CDs with Service Pack for<br />

Microsoft Windows 2000 (5 languages),<br />

Microsoft Internet Explorer,<br />

Microsoft SQL Server<br />

2000 <strong>and</strong> PC Anywhere<br />

CD "PCS 7/APACS+ Options<br />

Version 6.0"<br />

6EQ2 000-2AB06-3BA0 C)<br />

PCS 7/APACS+ SIMATIC BATCH<br />

Runtime license V6.0<br />

Single License for 1 installation,<br />

English<br />

Type of delivery:<br />

Certificate of license, authorization<br />

diskette<br />

6EQ2 000-6XX06-2BD0 C)<br />

C) Subject to export regulations: AL: N, ECCN: EAR99S<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

2/13<br />

12


12<br />

Migration to SIMATIC PCS 7<br />

Migration SIMATIC PCS/TISTAR<br />

Migration of SIMATIC PCS / TISTAR systems with<br />

505 controllers<br />

■ Overview<br />

Very many SIMATIC PCS / TISTAR systems are installed worldwide.<br />

These systems represent a wealth of hardware, user software<br />

<strong>and</strong> know-how accumulated by operating <strong>and</strong> maintenance<br />

personnel. To preserve the installed PCS/TISTAR<br />

platforms <strong>and</strong> add to their value, <strong>Siemens</strong> developed a migration<br />

strategy which aims to modernize existing operator <strong>and</strong> engineering<br />

systems whilst retaining the 505 controllers <strong>and</strong> the<br />

lower-lying I/O level. With this strategy the customer can migrate<br />

his existing system efficiently <strong>and</strong> economically without having<br />

to replace any controllers, I/O devices or their wiring, <strong>and</strong> without<br />

rendering the associated know-how useless.<br />

2/14<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

<strong>Siemens</strong> supplies the system platform for this migration strategy<br />

in the form of its innovative SIMATIC PCS 7 process control system.<br />

Through migration with SIMATIC PCS 7 <strong>Engineering</strong> <strong>and</strong> Operator<br />

<strong>System</strong>s it is possible to significantly increase the functionality<br />

<strong>and</strong> efficiency of process control systems based on<br />

505 controllers. And customers benefit in addition from continuous<br />

further development, long-term global support <strong>and</strong> the manifold<br />

advantages to be gained from TIA (Totally Integrated <strong>Automation</strong>)<br />

<strong>and</strong> SIMATIC IT. This protects existing investments,<br />

provides security for the future <strong>and</strong> increases plant productivity.


■ Overview<br />

A SIMATIC PCS 7 <strong>Engineering</strong> Station provided for the<br />

PCS 7/505 OS <strong>Engineering</strong> requires the following engineering<br />

software:<br />

Required software PCS 7/505 OS<br />

<strong>Engineering</strong> Station<br />

PCS 7/505 OS DBA x<br />

PCS 7/505 OS Server x<br />

PCS 7 <strong>Engineering</strong> Software OS<br />

x<br />

(see the chapter "ES Software" in the section<br />

"<strong>Engineering</strong> <strong>System</strong>")<br />

Additional engineering software for the installation on this <strong>Engineering</strong><br />

Station can be selected from the chapter "ES Software"<br />

in the section "<strong>Engineering</strong> <strong>System</strong>".<br />

A core component for the PCS 7/505 OS <strong>Engineering</strong> is the software<br />

application PCS 7/505 OS DBA (Database <strong>Automation</strong>).<br />

PCS 7/505 OS DBA automatically generates the OS database<br />

with the required variables, image hierarchies, specific block<br />

symbols <strong>and</strong> faceplates. The image hierarchy enables navigation<br />

between the process displays. PCS 7/505 OS DBA automatically<br />

places the type-specific block symbols, e.g. controller or<br />

analog input(AI), in the generated process displays. These symbols<br />

are linked to the corresponding function blocks <strong>and</strong> faceplates<br />

through the database. The manual configuration actions<br />

are mainly limited to the design <strong>and</strong> positioning of the of the<br />

static graphic elements, e.g. tubes or tanks.<br />

Migration to SIMATIC PCS 7<br />

Migration SIMATIC PCS/TISTAR<br />

C) Subject to export regulations: AL: N, ECCN: EAR99S<br />

PCS 7/505 ES Software<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

PCS 7/505 OS DBA V6.0<br />

Single license for 1 installation,<br />

English<br />

Electronic documentation on the<br />

CD "PCS 7/505 Options<br />

Version 6.0"<br />

Scope of delivery:<br />

License certificate <strong>and</strong> authorization<br />

diskette<br />

CD "PCS 7/505 Options<br />

Version 6.0"<br />

6EQ2 000-3EX06-2BC0 C)<br />

PCS 7/505 OS Server V6.0<br />

Single license for 1 installation,<br />

English<br />

Electronic documentation on the<br />

CD "PCS 7/505 Options<br />

Version 6.0"<br />

Scope of delivery:<br />

License certificate <strong>and</strong> authorization<br />

diskette<br />

CD "PCS 7/505 Options<br />

Version 6.0"<br />

6EQ2 000-3BX06-2BC0 C)<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

2/15<br />

12


12<br />

Migration to SIMATIC PCS 7<br />

Migration SIMATIC PCS/TISTAR<br />

PCS 7/505 OS Software<br />

■ Overview<br />

The PCS 7/505 operator system can be configured as a singleuser<br />

system (Single Station) or multi-user system with client/server<br />

architecture. SIMATIC PCS 7 support multi-user systems<br />

with up to 12 servers/redundant pairs of servers <strong>and</strong> up to<br />

32 clients.<br />

■ Design<br />

Depending on whether a SIMATIC PCS 7 basic device is configured<br />

as a PCS 7/505 OS Single Station, PCS 7/505 OS Server<br />

(single or redundant) or PCS 7/505 Client, the following OS software<br />

will be needed:<br />

Required software Architecture<br />

PCS 7/505 OS Single<br />

Station<br />

PCS 7 OS Single Station<br />

(see the chapter "OS<br />

Software" in the section<br />

"Operator <strong>System</strong>")<br />

The software components "PCS 7/505 OS Single Station&#148;<br />

<strong>and</strong> &#147;PCS 7/505 OS Server&#148; are tailored for the respective<br />

system architecture <strong>and</strong> supply not only special block<br />

symbols <strong>and</strong> faceplates but also the functionality for communicating<br />

with the 505 controllers.<br />

2/16<br />

PCS 7/505<br />

OS<br />

Single<br />

Station<br />

1<br />

1<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

PCS 7/505 OS Server PCS 7/505<br />

Client<br />

single redundant<br />

PCS 7/505 OS Server 1 2<br />

PCS 7 OS Server<br />

(see the chapter "OS<br />

Software" in the section<br />

"Operator <strong>System</strong>")<br />

1<br />

PCS 7 OS Redundant<br />

Server<br />

(see the chapter "OS<br />

Redundance" in the<br />

section "Operator<br />

<strong>System</strong>")<br />

1<br />

PCS 7 OS Client<br />

(see the chapter "OS<br />

Software" in the section<br />

"Operator <strong>System</strong>")<br />

1<br />

■ Selection <strong>and</strong> Ordering Data Order No.<br />

PCS 7/505 OS Server V6.0<br />

Single license for 1 installation,<br />

English<br />

Electronic documentation on the<br />

CD "PCS 7/505 Options Version<br />

6.0"<br />

Scope of delivery:<br />

License certificate <strong>and</strong> authorization<br />

diskette<br />

CD "PCS 7/505 Options Version<br />

6.0"<br />

6EQ2 000-3BX06-2BC0 C)<br />

PCS 7/505 OS Single Station<br />

V6.0<br />

Single license for 1 installation,<br />

English<br />

Electronic documentation on the<br />

CD "PCS 7/505 Options Version<br />

6.0"<br />

Scope of delivery:<br />

License certificate <strong>and</strong> authorization<br />

diskette<br />

CD "PCS 7/505 Options Version<br />

6.0"<br />

6EQ2 000-3AX06-2BC0 C)<br />

C) Subject to export regulations: AL: N, ECCN: EAR99S


Appendix<br />

13/2 Training<br />

13/3 <strong>Siemens</strong> contacts worldwide<br />

13/4 Service & Support<br />

13/5 Customer Support<br />

13/7 <strong>Siemens</strong> <strong>Automation</strong><br />

Solution Provider<br />

13/8 Software Licenses<br />

13/9 Index<br />

13/10 Order no. index<br />

13/14 Conditions of sale <strong>and</strong> delivery<br />

<strong>Siemens</strong> ST PCS 7 · October 2004


13<br />

Training<br />

13/2<br />

Appendix<br />

■ Training is decisive for your success<br />

SITRAIN ® Wide variety<br />

With a total of approx. 300 local attendance courses, we train the<br />

- the <strong>Siemens</strong> Training for <strong>Automation</strong> <strong>and</strong> Industrial complete range of A&D products <strong>and</strong> a large portion of the sys-<br />

Solutions - provides you with comprehensive support when solvtem solutions from I&S. Telecourses, teach-yourself software <strong>and</strong><br />

ing your tasks.<br />

seminars presented on the Web supplement our classical range<br />

Training by the market leader in automation, plant installation of courses.<br />

<strong>and</strong> support permits you to make your decisions with certainty Close to our customers<br />

<strong>and</strong> full comm<strong>and</strong>. Especially where the optimum <strong>and</strong> efficient<br />

use of products <strong>and</strong> plants are concerned. You can eliminate de- The distance is short. You can find us approx. 60 times in Gerficiencies<br />

in existing plants, <strong>and</strong> exclude expensive faulty planmany, <strong>and</strong> worldwide in 62 countries. You wish to have individual<br />

ning right from the beginning.<br />

training instead of one of our 300 courses? No problem: we will<br />

provide a program tailored exactly to your personal require-<br />

All in all, this represent an enormous gain for your company: ments. Training can be carried out in our Training Centers or at<br />

shortened startup times, optimized plant components, your company.<br />

faster troubleshooting, reduced down times. In other words,<br />

increased profits <strong>and</strong> lower costs.<br />

■ The right mixture: blended learning<br />

Blended learning is understood to be the combination of various<br />

training media <strong>and</strong> sequences. For example, a local attendance<br />

course in a Training Center can be optimally supplemented by a<br />

teach-yourself program as preparation or follow-up. Furthermore,<br />

SITRAIN utilizes supported online training for live instruction<br />

on the Internet at agreed times.<br />

The right mixture is the solution. Therefore blended learning<br />

can convey complex topics well, <strong>and</strong> train networked thinking.<br />

Additional effect: reduced travelling costs <strong>and</strong> periods<br />

of absence through training sequences independent of location<br />

<strong>and</strong> time.<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

■ The international training portal<br />

www.siemens.com/sitrain<br />

All training facilities at a glance: search in the worldwide range<br />

of courses at leisure, call up all course dates online, utilize the<br />

daily updated display of vacant course spaces - <strong>and</strong> register directly.<br />

Top trainers<br />

■ Customer comments on Sitrain<br />

" ... the good course documents, competence <strong>and</strong> flexibility convinced<br />

me."<br />

[Manfred Riek from Festo <strong>System</strong>technik, responsible for plan-<br />

Our trainers know their topics in practice, <strong>and</strong> possess comprening the basic <strong>and</strong> further training of project engineers]<br />

hensive didactic experience. Course developers have a direct<br />

wire to product development, <strong>and</strong> directly pass on their knowledge<br />

to the trainers.<br />

" ... represents effective training, constructive dialogs, <strong>and</strong> solutions<br />

which provide great help."<br />

[Günter Niedermaier, electrical design manager at AMT, Aalen]<br />

Practical experience<br />

The practical experience of our trainers makes it possible for ■ Contact<br />

them to pass on theoretical matter in a plausible manner. But<br />

since it is known that all theory is drab, we attach great importance<br />

to practical exercises which can comprise up to half of the<br />

Visit us on the Internet at:<br />

www.siemens.com/sitrain<br />

course time. You can therefore immediately implement your new<br />

knowledge in practice. We train you on state-of-the-art methodically/didactically<br />

designed training equipment. You feel abso-<br />

or let us advise you personally. You can request our latest training<br />

catalog from:<br />

lutely certain when trained in this manner.<br />

Course office, Infoline Germany:<br />

Tel.: 01805 / 23 56 11 (0.12 €/Min)<br />

Fax: 01805 / 23 56 12


At<br />

www.siemens.com/automation/partner<br />

Appendix<br />

<strong>Siemens</strong> contacts worldwide<br />

you can find details of <strong>Siemens</strong> contact partners worldwide responsible<br />

for particular technologies.<br />

You can obtain in most cases a contact partner for<br />

Technical Support,<br />

Spare parts/repairs,<br />

Service,<br />

Training,<br />

Sales or<br />

Consultation/engineering.<br />

You start by selecting a<br />

Country,<br />

Product or<br />

Sector.<br />

By further specifying the remaining criteria you will find exactly<br />

the right contact partner with his/her respective expertise.<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

13/3<br />

13


13<br />

Appendix<br />

Service & Support<br />

Information <strong>and</strong> Ordering<br />

in the Internet <strong>and</strong> on CD-ROM<br />

■ A&D in the WWW<br />

■ Product Selection Using the Interactive Catalog<br />

■ Easy Shopping with the A&D Mall<br />

13/4<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

A detailed knowledge of the range of products <strong>and</strong> services<br />

available is essential when planning <strong>and</strong> configuring automation<br />

systems. It goes without saying that this information must always<br />

be fully up-to-date.<br />

The <strong>Siemens</strong> <strong>Automation</strong> <strong>and</strong> <strong>Drives</strong> <strong>Group</strong> (A&D) has therefore<br />

built up a comprehensive range of information in the World Wide<br />

Web, which offers quick <strong>and</strong> easy access to all data required.<br />

Under the address<br />

http://www.siemens.com/automation<br />

you will find everything you need to know about products, systems<br />

<strong>and</strong> services.<br />

Detailed information together with convenient interactive functions:<br />

The interactive catalog CA 01 covers more than 80,000 products<br />

<strong>and</strong> thus provides a full summary of the <strong>Siemens</strong> <strong>Automation</strong><br />

<strong>and</strong> <strong>Drives</strong> product base.<br />

Here you will find everything that you need to solve tasks in the<br />

fields of automation, switchgear, installation <strong>and</strong> drives.<br />

All information is linked into a user interface which is easy to<br />

work with <strong>and</strong> intuitive.<br />

After selecting the product of your choice you can order at the<br />

press of a button, by fax or by online link.<br />

Information on the interactive catalog can be found in the Internet<br />

under<br />

http://www.siemens.com/automation/ca01<br />

or on CD-ROM:<br />

<strong>Automation</strong> & <strong>Drives</strong> CA 01,<br />

Order No.: E86060-D4001-A110-C2-7600<br />

The A&D Mall is the virtual department store of <strong>Siemens</strong> AG in<br />

the Internet. Here you have access to a huge range of products<br />

presented in electronic catalogs in an informative <strong>and</strong> attractive<br />

way.<br />

Data transfer via EDIFACT allows the whole procedure from selection<br />

through ordering to tracking of the order to be carried out<br />

online via the Internet.<br />

Numerous functions are available to support you.<br />

For example, powerful search functions make it easy to find the<br />

required products, which can be immediately checked for availability.<br />

Customer-specific discounts <strong>and</strong> preparation of quotes<br />

can be carried out online as well as order tracking <strong>and</strong> tracing.<br />

Please visit the A&D Mall on the Internet under:<br />

http://www.siemens.com/automation/mall


.I<br />

In the face of harsh competition you need optimum conditions to<br />

keep ahead all the time:<br />

A strong starting position. A sophisticated strategy <strong>and</strong> team for<br />

the necessary support - in every phase.<br />

Service & Support from <strong>Siemens</strong> provides this support with a<br />

complete range of different services for automation <strong>and</strong> drives.<br />

In every phase: from planning <strong>and</strong> startup to maintenance <strong>and</strong><br />

upgrading.<br />

Our specialists know when <strong>and</strong> where to act to keep the productivity<br />

<strong>and</strong> cost-effectiveness of your system running in top form.<br />

■ Online Support<br />

■ Technical Support<br />

■ Technical Consulting<br />

The comprehensive information<br />

system available round the<br />

clock via Internet ranging from<br />

Product Support <strong>and</strong> Service &<br />

Support services to Support<br />

Tools in the Shop.<br />

http://www.siemens.com/<br />

automation/service&support<br />

Competent consulting in technical<br />

questions covering a wide<br />

range of customer-oriented services<br />

for all our products <strong>and</strong><br />

systems.<br />

Tel.: +49 (0)180 50 50 222<br />

Fax: +49 (0)180 50 50 223<br />

E-Mail:<br />

adsupport@siemens.com<br />

Support in the planning <strong>and</strong> designing<br />

of your project from detailed<br />

actual-state analysis,<br />

target definition <strong>and</strong> consulting<br />

on product <strong>and</strong> system questions<br />

right to the creation of the<br />

automation solution. 1 )<br />

Appendix<br />

Customer Support<br />

Our Services for Every Phase of Your Project<br />

■ Configuration <strong>and</strong> Software <strong>Engineering</strong><br />

Support in configuring <strong>and</strong> developing<br />

with customer-oriented<br />

services from actual configuration<br />

to implementation of the automation<br />

project. 1 )<br />

■ Service On Site<br />

■ Repairs <strong>and</strong> Spare Parts<br />

■ Optimization <strong>and</strong> Upgrading<br />

With Service On Site we offer<br />

services for startup <strong>and</strong> maintenance,<br />

essential for ensuring<br />

system availability.<br />

In Germany<br />

0180 50 50 444 1 )<br />

In the operating phase of a machine<br />

or automation system we<br />

provide a comprehensive repair<br />

<strong>and</strong> spare parts service ensuring<br />

the highest degree of operating<br />

safety <strong>and</strong> reliability.<br />

In Germany<br />

0180 50 50 448 1 )<br />

To enhance productivity <strong>and</strong><br />

save costs in your project we offer<br />

high-quality services in optimization<br />

<strong>and</strong> upgrading. 1 )<br />

1) For country-specific telephone numbers go to our Internet site at:<br />

http://www.siemens.com/automation/service&support<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

13/5<br />

13


13<br />

Appendix<br />

Customer Support<br />

■ Knowledge Base on CD-ROM<br />

For locations without online connections<br />

to the Internet there are<br />

excerpts of the free part of the<br />

information sources available on<br />

CD-ROM (Service & Support<br />

Knowledge Base). This CD-<br />

ROM contains all the latest<br />

product information at the time<br />

of production (FAQs, Downloads,<br />

Tips <strong>and</strong> Tricks, Updates)<br />

as well as general information<br />

on Service <strong>and</strong> Technical Support.<br />

■ <strong>Automation</strong> Value Card<br />

Small card - great support<br />

The <strong>Automation</strong> Value Card is an integral component of the comprehensive<br />

service concept with which <strong>Siemens</strong> <strong>Automation</strong> <strong>and</strong><br />

<strong>Drives</strong> will accompany you in each phase of your automation<br />

project.<br />

It doesn't matter whether you want just specific services from our<br />

Technical Support or want to purchase high-quality Support<br />

Tools in our Online Shop, you can always pay with your <strong>Automation</strong><br />

Value Card. No invoicing, transparent <strong>and</strong> safe. With your<br />

personal card number <strong>and</strong> associated PIN you can view the<br />

state of your account <strong>and</strong> all transactions at any time.<br />

Services on card. This is how it's done.<br />

Card number <strong>and</strong> PIN are on the back of the <strong>Automation</strong> Value<br />

Card. When delivered, the PIN is covered by a scratch field,<br />

guaranteeing that the full credit is on the card.<br />

13/6<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

The CD-ROM also includes a full-text search <strong>and</strong> our Knowledge<br />

Manager for targeted searches for solutions. The CD-ROM will<br />

be updated every 4 months.<br />

Just the same as our online offer in the Internet, the Service &<br />

Support Knowledge Base on CD comes complete in 5 languages<br />

(German, English, French, Italian, Spanish).<br />

You can order the Service & Support Knowledge Base CD<br />

from your <strong>Siemens</strong> contact.<br />

Order no. 6ZB5310-0EP30-0BA2<br />

Orders via the Internet<br />

(with <strong>Automation</strong> Value Card or credit card) at:<br />

http://www.siemens.com/automation/service&support<br />

in the Shop domain.<br />

By entering the card number <strong>and</strong> PIN you have full access to the<br />

Service & Support services being offered. The charge for the<br />

services procured is debited from the credits on your <strong>Automation</strong><br />

Value Card.<br />

All the services offered are marked in currency-neutral credits,<br />

so you can use the <strong>Automation</strong> Value Card worldwide.<br />

<strong>Automation</strong> Value Card order numbers<br />

Credits Order no.<br />

200 6ES7 997-0BA00-0XA0<br />

500 6ES7 997-0BB00-0XA0<br />

1000 6ES7 997-0BC00-0XA0<br />

10000 6ES7 997-0BG00-0XA0<br />

Detailed information on the services offered is available on our<br />

Internet site at:<br />

http://www.siemens.com/automation/service&support<br />

Service & Support à la Card: Examples<br />

Technical Support<br />

”Priority“ Priority processing for urgent cases<br />

”24 h“ Availability round the clock<br />

„Extended“ Technical consulting for complex questions<br />

Support Tools in the Support Shop<br />

”<strong>System</strong> Utili- Tools that can be used directly for configuration, analties“ysis<br />

<strong>and</strong> testing<br />

”Applications“ Complete topic solutions including ready-tested software<br />

”Functions & Adaptable blocks for accelerating your developments<br />

Samples“


■ <strong>Siemens</strong> <strong>Automation</strong> Solution Provider<br />

<strong>Automation</strong> solutions are becoming increasingly complex, <strong>and</strong><br />

dem<strong>and</strong>s are permanently growing. We can help you find competent<br />

partners for an excellent, reliable solution. Partners who<br />

have competence <strong>and</strong> experience in the required sector linked<br />

with comprehensive know-how for automation solutions.<br />

Our partner programs set new st<strong>and</strong>ards with respect to the specific<br />

competence of the companies involved <strong>and</strong> the global network<br />

of partners. As a result of the careful selection <strong>and</strong> permanent<br />

training of our solution providers, you will always be able to<br />

find a competent partner close at h<strong>and</strong> who is always working<br />

with state-of-the-art technology.<br />

The program<br />

You are searching for automation solutions for a particular task?<br />

Or you require professional consulting <strong>and</strong> support? You wish to<br />

contact specialists in your sector? You wish to secure market advantages?<br />

Then our <strong>Siemens</strong> automation solution providers are<br />

the right partners for you!<br />

Our partner companies possess the know-how for developing<br />

reliable, economic <strong>and</strong> future-oriented solutions – for all sectors<br />

<strong>and</strong> all automation components: covering all SIMATIC components,<br />

visualization systems, communi-cations networks using<br />

SIMATIC PCS 7, microsystems <strong>and</strong> motion control systems up to<br />

products for vertical integration of industrial automation <strong>and</strong> office<br />

environments.<br />

Appendix<br />

<strong>Siemens</strong> <strong>Automation</strong> Solution Provider<br />

Your benefits<br />

Customized, economic <strong>and</strong> future-oriented solutions<br />

Significant advantages with respect to speed, efficiency <strong>and</strong><br />

locality<br />

Solution provider has special knowledge of sector<br />

Guaranteed state-of-the-art technology <strong>and</strong> knowledge of latest<br />

developments<br />

Certification<br />

The solution providers are continuously being trained in order to<br />

remain completely up-to-date. They are subjected to a special<br />

certification program where they have to prove their high competence<br />

using <strong>Siemens</strong>’ automation tools. We can therefore<br />

guarantee a special st<strong>and</strong>ard of quality which is successively<br />

achieved by training on new components <strong>and</strong> during special solution<br />

provider workshops.<br />

Internet:<br />

www.siemens.com/automation/solution-provider<br />

E-Mail:<br />

SSPinfo@nbgm.siemens.de<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

13/7<br />

13


13<br />

Appendix<br />

Software Licenses<br />

■ Overview<br />

Software types<br />

Software requiring a license is categorized into types.<br />

The following software types have been defined:<br />

<strong>Engineering</strong> software<br />

Runtime software<br />

<strong>Engineering</strong> software<br />

This includes all software products for creating (engineering)<br />

user software, e.g. for configuring, programming, parameterizing,<br />

testing, commissioning or servicing.<br />

Data generated with engineering software <strong>and</strong> executable<br />

programs can be duplicated for your own use or for use by thirdparties<br />

free-of-charge.<br />

Runtime software<br />

This includes all software products required for plant/machine<br />

operation, e.g. operating system, basic system, system expansions,<br />

drivers, etc.<br />

The duplication of the runtime software <strong>and</strong> executable programs<br />

created with the runtime software for your own use or for<br />

use by third-parties is subject to a charge.<br />

You can find information about license fees according to use in<br />

the ordering data (e.g. in the catalog). Examples of categories of<br />

use include per CPU, per installation, per channel, per instance,<br />

per axis, per control loop, per variable, etc.<br />

Information about extended rights of use for parameterization/configuration<br />

tools supplied as integral components of the<br />

scope of delivery can be found in the readme file supplied with<br />

the relevant product(s).<br />

License types<br />

<strong>Siemens</strong> <strong>Automation</strong> & <strong>Drives</strong> offers various types of software<br />

license:<br />

Floating license<br />

Single license<br />

Rental license<br />

Trial license<br />

Floating license<br />

The software may be installed for internal use on any number of<br />

devices by the licensee. Only the concurrent user is licensed.<br />

The concurrent user is the person using the program. Use begins<br />

when the software is started.<br />

A license is required for each concurrent user.<br />

Single license<br />

Unlike the floating license, a single license permits only one<br />

installation of the software.<br />

The type of use licensed is specified in the ordering data <strong>and</strong><br />

in the Certificate of License (CoL). Types of use include for<br />

example per device, per axis, per channel, etc.<br />

One single license is required for each type of use defined.<br />

Rental license<br />

A rental license supports the "sporadic use" of engineering<br />

software. Once the license key has been installed, the software<br />

can be used for a specific number of hours (the operating hours<br />

do not have to be consecutive).<br />

One license is required for each installation of the software.<br />

Trial license<br />

A trial license supports "short-term use" of the software in a nonproductive<br />

context, e.g. for testing <strong>and</strong> evaluation purposes.<br />

It can be transferred to another license.<br />

13/8<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

Certificate of license<br />

The Certificate of License (CoL) is the licensee's proof that the<br />

use of the software has been licensed by <strong>Siemens</strong>. A CoL is<br />

required for every type of use <strong>and</strong> must be kept in a safe place.<br />

Downgrading<br />

The licensee is permitted to use the software or an earlier version/release<br />

of the software, provided that the licensee owns<br />

such a version/release <strong>and</strong> its use is technically feasible.<br />

Delivery versions<br />

Software is constantly being updated.<br />

The following delivery versions<br />

PowerPack<br />

Upgrade<br />

can be used to access updates.<br />

Existing bug fixes are supplied with the ServicePack version.<br />

PowerPack<br />

PowerPacks can be used to upgrade to more powerful software.<br />

The licensee receives a new license agreement <strong>and</strong> CoL<br />

(Certificate of License) with the PowerPack. This CoL, together<br />

with the CoL for the original product, proves that the new software<br />

is licensed.<br />

A separate PowerPack must be purchased for each original<br />

license of the software to be replaced.<br />

Upgrade<br />

An upgrade permits the use of a new version of the software on<br />

the condition that a license for a previous version of the product<br />

is already held.<br />

The licensee receives a new license agreement <strong>and</strong> CoL with<br />

the upgrade. This CoL, together with the CoL for the previous<br />

product, proves that the new version is licensed.<br />

A separate upgrade must be purchased for each original license<br />

of the software to be upgraded.<br />

ServicePack<br />

ServicePacks are used to debug existing products.<br />

ServicePacks may be duplicated for use as prescribed according<br />

to the number of existing original licenses.<br />

License key<br />

<strong>Siemens</strong> <strong>Automation</strong> & <strong>Drives</strong> supplies software products with<br />

<strong>and</strong> without license keys.<br />

The license key serves as an electronic license stamp <strong>and</strong><br />

is also the "switch" for activating the software (floating license,<br />

rental license, etc.).<br />

The complete installation of software products requiring license<br />

keys includes the program to be licensed (the software) <strong>and</strong> the<br />

license key (which represents the license).<br />

Detailed explanations concerning license conditions can be<br />

found in the “Terms <strong>and</strong> Conditions of <strong>Siemens</strong> AG” or under<br />

http://www.siemens.com/automation/mall<br />

(A&D Mall Online-Help <strong>System</strong>)


■<br />

@<br />

@PCS 7 .............................................................8/3<br />

A<br />

Administration ...................................................2/3<br />

Alarms...............................................................5/9<br />

APACS+ ........................................................12/10<br />

Archive server..........................................5/4, 5/11<br />

AS-Interface ....................................................9/19<br />

AS migration from TELEPERM M ....................12/8<br />

<strong>Automation</strong> systems........................................10/2<br />

B<br />

Basic hardware ..........................................2/6, 4/3<br />

Batch Control Center ........................................6/6<br />

Batch Planning..................................................6/8<br />

Batch automation..............................................6/2<br />

Branch & Merge................................................4/6<br />

C<br />

Central I/O modules........................................11/3<br />

CFC...................................................................4/6<br />

Chip card reader...............................................2/3<br />

Client/server architecture..................................5/4<br />

Communications module ..................................9/8<br />

Connectivity Pack ...........................................5/14<br />

Contacts..........................................................13/3<br />

Controller modules........................................11/19<br />

Controller optimization ....................................4/20<br />

Counter modules ..........................................11/20<br />

Coupling package PCS 7/TM-OS ...................12/4<br />

CP 1612 ............................................................9/8<br />

CP 1613 ............................................................9/8<br />

CP 341 ............................................................9/21<br />

CP 443-1 ................................................10/5, 10/8<br />

CP 443-5 .......................................9/13, 10/5, 10/8<br />

Customer Support...........................................13/6<br />

D<br />

DOCPRO...........................................................4/6<br />

Documentation..................................................2/2<br />

DP/PA Coupler ................................................9/16<br />

E<br />

EDD.................................................................4/16<br />

EIB instabus....................................................9/20<br />

Electrical Switch Module...................................9/5<br />

Electronic signature ..........................................2/3<br />

Electronic modules .......................................11/29<br />

<strong>Engineering</strong> <strong>System</strong>..........................................4/2<br />

ES software .......................................................4/4<br />

ET 200iS........................................................11/21<br />

ET 200M..........................................................11/5<br />

ET 200S.........................................................11/24<br />

Ex zone ................................................11/2, 11/15<br />

Expansion devices..........................................11/4<br />

F<br />

F modules .....................................................11/17<br />

F systems........................................................10/9<br />

Faceplate Designer ..........................................4/6<br />

Failsafe automation systems...........................10/9<br />

Fast Ethernet.....................................................9/4<br />

FastConnect.............................................9/7, 9/18<br />

Fault-tolerant automation systems ..................10/6<br />

Fiber optic cable.............................................9/11<br />

G<br />

Graphics Designer ........................................... 4/6<br />

H<br />

H systems................................................ 4/8, 10/6<br />

HART ............................................................ 11/16<br />

Hierarchical Recipe.......................................... 6/9<br />

Horizontal integration ....................................... 1/8<br />

Hot swapping ................................................. 9/16<br />

I<br />

Image & Partition Creator................................. 2/8<br />

Import/export assistant..................................... 4/9<br />

Industrial Ethernet ............................................ 9/3<br />

L<br />

Libraries ........................................................... 4/5<br />

M<br />

Measuring point ............................................... 5/3<br />

Messages......................................................... 5/9<br />

Modbus .......................................................... 9/21<br />

Motor starter ................................................. 11/31<br />

Multi-client ........................................................ 5/4<br />

Multi-VGA graphics card................................ 2/10<br />

N<br />

NORA ............................................................. 12/5<br />

O<br />

Operator <strong>System</strong> .............................................. 5/2<br />

Optical Switch Module ..................................... 9/4<br />

OS Variable ...................................................... 5/3<br />

OS migration from TELEPERM M ................... 12/4<br />

OS redundancy .............................................. 5/15<br />

OS software...................................................... 5/8<br />

P<br />

PCS 7/505 .................................................... 12/14<br />

PCS 7/TM-OS ................................................. 12/4<br />

PID Tuner........................................................ 4/20<br />

Plant Hierarchy................................................. 4/5<br />

Plant view ......................................................... 4/5<br />

PO .................................................................... 5/3<br />

Process monitor.............................................. 2/11<br />

Process objekt (PO) ......................................... 5/3<br />

Process objekt view.......................................... 4/5<br />

PROFIBUS........................................................ 9/9<br />

R<br />

Recipe <strong>System</strong> ................................................. 6/7<br />

Redundancy................................................... 5/15<br />

ROP Library...................................................... 6/9<br />

Route Control ................................................. 4/14<br />

RS485-iS.............................................. 9/10, 11/23<br />

Appendix<br />

<strong>Siemens</strong> ST PCS 7 · November 2004<br />

Index<br />

S<br />

S7 F <strong>System</strong>s ..................................................4/11<br />

S7-300 modules...........................................11/9 ff<br />

S7-400 modules..............................................11/3<br />

S7-PLCSIM .....................................................4/20<br />

Safety Matrix ...................................................4/12<br />

Safety Matrix Viewer .......................................5/13<br />

SFC ...................................................................4/6<br />

SFC visualization ............................................5/13<br />

Signal module...................................................5/7<br />

Sign-of-life monitoring.......................................5/9<br />

SIGUARD......................................................11/33<br />

SIMATIC BATCH ...............................................6/2<br />

SIMATIC IT ........................................................8/2<br />

SIMATIC Logon.................................................2/3<br />

SIMATIC Manager.............................................4/5<br />

SIMATIC NET ....................................................9/2<br />

SIMATIC PCS ................................................12/14<br />

SIMATIC PCS 7 BOX.........................................3/2<br />

SIMATIC PDM .................................................4/15<br />

SIMATIC Route Control ............................4/14, 7/2<br />

SIMATIC Safety Matrix ...........................4/12, 5/13<br />

Simulation .......................................................4/20<br />

Solution Provider.............................................13/7<br />

SpliTConnect ..................................................9/18<br />

StoragePlus ....................................................5/12<br />

<strong>System</strong> architecture ..........................................1/8<br />

T<br />

TELEPERM M..................................................12/2<br />

TELEPERM M Manual Collection......................2/2<br />

Terminal modules..........................................11/26<br />

Time synchronization........................................5/9<br />

TISTAR ..........................................................12/14<br />

Totally Integrated <strong>Automation</strong> (TIA) ...........1/4, 1/8<br />

Training ...........................................................13/2<br />

V<br />

Version Cross Checker .....................................4/8<br />

Vertical integration ............................................1/8<br />

Y<br />

Y-link ...............................................................9/14<br />

13/9<br />

13


13<br />

Appendix<br />

Order no. index<br />

■<br />

3RK1 301-0AB10-.... ............................... 11/31<br />

3RK1 301-0AB13-.... ............................... 11/32<br />

3RK1 301-0AB20-.... ............................... 11/31<br />

3RK1 301-0BB10-.... ............................... 11/31<br />

3RK1 301-0BB13-.... ............................... 11/32<br />

3RK1 301-0BB20-.... ............................... 11/31<br />

3RK1 301-0CB10-................................... 11/31<br />

3RK1 301-0CB13-................................... 11/32<br />

3RK1 301-0CB20-................................... 11/31<br />

3RK1 903-0A........................................... 11/31<br />

3RK1 903-0B........................................... 11/28<br />

3RK1 903-0CB.. ...................................... 11/31<br />

3RK1 903-0CC........................................ 11/31<br />

3RK1 903-0CE.. ........................... 11/31, 11/32<br />

3RK1 903-0CF.............................. 11/31, 11/32<br />

3RK1 903-0CH........................................ 11/31<br />

3RK1 903-1.... ......................................... 11/34<br />

3RK1 903-2.... .............................. 11/31, 11/32<br />

3RK1 903-3A........................................... 11/32<br />

3RK1 903-3B........................................... 11/28<br />

3RK1 903-3C... ....................................... 11/28<br />

3RK1 903-3D... ....................................... 11/28<br />

6AG1 321-1............................................... 11/9<br />

6AG1 321-7............................................. 11/10<br />

6AG1 322-1............................................. 11/11<br />

6AG1 322-8............................................. 11/12<br />

6AG1 323-1.................................... 11/9, 11/11<br />

6AG1 331-7............................................. 11/13<br />

6AG1 332-5............................................. 11/14<br />

6AV3 617-1JC20-0AX1 ........................... 11/20<br />

6AV6 371-1C............................................. 5/16<br />

6AV6 371-1D............................................. 5/14<br />

6AV6 371-1E... .......................................... 5/14<br />

6AV6 392-1D............................................. 5/16<br />

6AV8 101-..... ............................................ 2/11<br />

6DL2 100-..... ............................................ 12/9<br />

6DL2 207-... .............................................. 12/6<br />

6DL2 804-..... .......................................... 11/21<br />

6DL5 200-..... ............................................ 12/7<br />

6DL5 900-..... .............................................. 2/2<br />

6DS1 916-... ................................................ 5/7<br />

6DS5 ... ..................................................... 12/7<br />

6EP1 ... ....................................................... 3/4<br />

6EQ2 000-1A... ....................................... 12/11<br />

6EQ2 000-2A... ....................................... 12/13<br />

6EQ2 000-2B... ....................................... 12/13<br />

6EQ2 000-2D... ....................................... 12/13<br />

6EQ2 000-2E........................................... 12/11<br />

6EQ2 000-3A... ....................................... 12/16<br />

6EQ2 000-3B... ............................ 12/15, 12/16<br />

6EQ2 000-3E........................................... 12/15<br />

6EQ2 000-5X........................................... 12/11<br />

6EQ2 000-6X........................................... 12/13<br />

6ES7 131-4.... ......................................... 11/29<br />

6ES7 131-5.... ......................................... 11/22<br />

6ES7 132-4.... ......................................... 11/29<br />

6ES7 132-5.... ......................................... 11/22<br />

6ES7 134-4.... ......................................... 11/30<br />

6ES7 134-5.... ......................................... 11/22<br />

6ES7 135-4.... ......................................... 11/30<br />

6ES7 135-5.... ......................................... 11/22<br />

6ES7 138-4C........................................... 11/28<br />

6ES7 138-4F............................................ 11/29<br />

6ES7 138-5E... ........................................ 11/23<br />

6ES7 151-1.... ......................................... 11/28<br />

6ES7 151-2.... ......................................... 11/23<br />

6ES7 153-2A... .......................................... 11/8<br />

6ES7 153-2B... .......................................... 11/6<br />

6ES7 157-0.... ........................................... 9/17<br />

13/10<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

6ES7 193-4CA......................................... 11/27<br />

6ES7 193-4CB......................................... 11/27<br />

6ES7 193-4CC......................................... 11/26<br />

6ES7 193-4CD......................................... 11/26<br />

6ES7 193-4CE.. ....................................... 11/26<br />

6ES7 193-4CF.......................................... 11/27<br />

6ES7 193-4CG.. ...................................... 11/27<br />

6ES7 193-4CK......................................... 11/26<br />

6ES7 193-4CL.. ....................................... 11/27<br />

6ES7 193-5C... ........................................ 11/22<br />

6ES7 193-5D... ........................................ 11/23<br />

6ES7 195-1B... .......................................... 9/12<br />

6ES7 195-1G... ................................. 9/17, 11/7<br />

6ES7 195-1J... ........................................... 11/7<br />

6ES7 195-1K... .......................................... 11/7<br />

6ES7 195-7HA........................................... 11/7<br />

6ES7 195-7HB........................................... 11/7<br />

6ES7 195-7HC........................................... 11/7<br />

6ES7 195-7HD10-.... ................................. 11/7<br />

6ES7 195-7HD80-.... ................................. 9/17<br />

6ES7 195-7HF80-.... .................................. 9/17<br />

6ES7 195-7HG00-.... ............................... 11/17<br />

6ES7 195-7KF00-.... ................................ 11/17<br />

6ES7 197-......................................... 9/14, 10/8<br />

6ES7 305-................................ 9/14, 9/17, 11/6<br />

6ES7 307-................................ 9/14, 9/17, 11/6<br />

6ES7 321-1................................................ 11/9<br />

6ES7 321-7B... ........................................ 11/10<br />

6ES7 321-7R... ........................................ 11/15<br />

6ES7 321-7T... ......................................... 11/10<br />

6ES7 322-1.............................................. 11/11<br />

6ES7 322-5F... ......................................... 11/12<br />

6ES7 322-5G... ........................................ 11/12<br />

6ES7 322-5H... ........................................ 11/12<br />

6ES7 322-5R... ........................................ 11/15<br />

6ES7 322-5S............................................ 11/15<br />

6ES7 322-8B... ........................................ 11/12<br />

6ES7 326-................................................ 11/17<br />

6ES7 331-1K... ........................................ 11/13<br />

6ES7 331-7K... ........................................ 11/13<br />

6ES7 331-7N... ........................................ 11/13<br />

6ES7 331-7P... ......................................... 11/13<br />

6ES7 331-7R... ........................................ 11/15<br />

6ES7 331-7S............................................ 11/15<br />

6ES7 331-7T... ......................................... 11/16<br />

6ES7 332-5H... ........................................ 11/14<br />

6ES7 332-5R... ........................................ 11/15<br />

6ES7 332-5T... ......................................... 11/16<br />

6ES7 332-7N... ........................................ 11/14<br />

6ES7 336-1H... ........................................ 11/17<br />

6ES7 341-.................................................. 9/21<br />

6ES7 350-................................................ 11/20<br />

6ES7 355-................................................ 11/20<br />

6ES7 390-.................................................. 9/17<br />

6ES7 392-1AJ00-.... ......................... 9/19, 11/7<br />

6ES7 392-1AJ20-.... .................................. 11/7<br />

6ES7 392-1AM.. ........................................ 11/7<br />

6ES7 392-1B... .......................................... 11/7<br />

6ES7 393-4A... .......................................... 11/7<br />

6ES7 400-1.............................. 10/5, 10/8, 11/4<br />

6ES7 400-2................................................ 10/8<br />

6ES7 405-0KA.. ................................ 10/5, 10/8<br />

6ES7 405-0KR.. ......................................... 10/5<br />

6ES7 405-0RA.. ......................................... 10/5<br />

6ES7 407-0KA.. ......................................... 10/5<br />

6ES7 407-0KR.. ................................ 10/5, 10/8<br />

6ES7 407-0RA.. ......................................... 10/5<br />

6ES7 414-3................................................ 10/5<br />

6ES7 414-4................................................ 10/8<br />

6ES7 416-.................................................. 10/5<br />

6ES7 417-4H... .......................................... 10/8<br />

6ES7 417-4X.............................................. 10/5<br />

6ES7 421-..... .............................................11/3<br />

6ES7 422-..... .............................................11/3<br />

6ES7 431-..... .............................................11/3<br />

6ES7 432-..... .............................................11/3<br />

6ES7 460-..... .............................................11/4<br />

6ES7 461-..... .............................................11/4<br />

6ES7 468-..... .............................................11/4<br />

6ES7 478-..... .............................................12/9<br />

6ES7 492-..... .............................................11/3<br />

6ES7 648-0C.............2/9, 3/4, 4/3, 5/6, 6/4, 7/4<br />

6ES7 648-2A....................2/9, 4/3, 5/6, 6/4, 7/4<br />

6ES7 648-6A....................2/9, 4/3, 5/6, 6/4, 7/4<br />

6ES7 650-0GC06-....2/9, 4/3, 5/5, 6/4, 7/3, 12/6<br />

6ES7 650-0GC16-............2/9, 4/3, 5/5, 6/4, 7/3<br />

6ES7 650-0GD06-..........2/9, 5/6, 6/4 ,7/4, 12/6<br />

6ES7 650-0GE06-.... ...............2/9, 5/5, 6/4, 7/4<br />

6ES7 650-0GE16-.... ......................2/9, 5/5, 7/4<br />

6ES7 650-0XX06-0..........................11/8, 11/16<br />

6ES7 650-0XX06-8.......................................2/2<br />

6ES7 650-2H................................................3/4<br />

6ES7 652-0XC.. .........................................5/12<br />

6ES7 652-0XD.. .........................................5/13<br />

6ES7 652-0XX01-.........................................2/3<br />

6ES7 652-0XX03-...........2/10, 4/3, 5/6, 6/4, 7/4<br />

6ES7 652-0XX05-.........................................2/3<br />

6ES7 652-3.... ............................................5/16<br />

6ES7 653-0.... ............................................4/20<br />

6ES7 653-1.... ..............................................2/2<br />

6ES7 653-2.... ...................................10/5, 10/8<br />

6ES7 654-0.... ............................................11/8<br />

6ES7 654-1.... ............................................10/4<br />

6ES7 654-2.... ............................................10/7<br />

6ES7 654-3.... ............................................10/4<br />

6ES7 654-4.... ............................................10/4<br />

6ES7 654-5.... ............................................10/7<br />

6ES7 654-6.... ............................................10/4<br />

6ES7 657-0A................................................6/7<br />

6ES7 657-0B................................................6/8<br />

6ES7 657-0F.................................................6/9<br />

6ES7 657-0G... ............................................6/9<br />

6ES7 657-0H..............................................6/10<br />

6ES7 657-0L... .............................................6/6<br />

6ES7 657-0M... ..........................................6/10<br />

6ES7 657-0S.... ............................................6/5<br />

6ES7 657-0XB..............................................6/5<br />

6ES7 657-0XC.. ...........................................6/5<br />

6ES7 657-0XD.. ...........................................6/5<br />

6ES7 657-0XE..............................................6/5<br />

6ES7 657-0XX............................................6/10<br />

6ES7 658-0.... ..............................................8/4<br />

6ES7 658-1A................................................4/7<br />

6ES7 658-1C................................................4/8<br />

6ES7 658-1D................................................4/9<br />

6ES7 658-2AA.. .........................................5/10<br />

6ES7 658-2AB06-0YA0..............................5/10<br />

6ES7 658-2AB06-0YD0 ......................3/4, 5/10<br />

6ES7 658-2AB06-0YE0..............................5/10<br />

6ES7 658-2AC.. .........................................5/10<br />

6ES7 658-2AD.. .........................................5/10<br />

6ES7 658-2BA.. ................................5/10, 5/11<br />

6ES7 658-2BB.. .........................................5/10<br />

6ES7 658-2BC.. .........................................5/10<br />

6ES7 658-2BD.. .........................................5/10<br />

6ES7 658-2BE............................................5/10<br />

6ES7 658-2CX.. .........................................5/10


■<br />

6ES7 658-2D............................................... 4/7<br />

6ES7 658-2E... .......................................... 5/11<br />

6ES7 658-3AX05-0YC0............................. 4/19<br />

6ES7 658-3AX05-0YC3.................... 4/17, 4/19<br />

6ES7 658-3BX00-2XD0............................. 4/19<br />

6ES7 658-3CX00-2XD0............................. 4/19<br />

6ES7 658-3EX00-2XD0 .................... 4/17, 4/19<br />

6ES7 658-3GX05-0YC8 ................... 4/17, 4/19<br />

6ES7 658-3PX05-0YC0 ...................... 3/4, 4/17<br />

6ES7 658-3XA00-2XD0............................. 4/19<br />

6ES7 658-3XB00-2XD0............................. 4/19<br />

6ES7 658-3XB05-2XD5.................... 4/17, 4/19<br />

6ES7 658-3XC00-2XD0............................. 4/19<br />

6ES7 658-3XC05-2XD5.................... 4/17, 4/19<br />

6ES7 658-3XD00-2XD0............................. 4/19<br />

6ES7 658-3XD05-2XD5.................... 4/17, 4/19<br />

6ES7 658-3XH.................................. 4/17, 4/19<br />

6ES7 658-4XX.. ........................................... 2/4<br />

6ES7 658-5AA............................................. 4/7<br />

6ES7 658-5AB06-0YA0 ............................... 4/7<br />

6ES7 658-5AB06-0YD0........................ 3/4, 4/7<br />

6ES7 658-5AC.. .......................................... 4/7<br />

6ES7 658-5AD.. .......................................... 4/7<br />

6ES7 658-5AE............................................. 4/7<br />

6ES7 658-7AX21-2YB5 ............................... 2/3<br />

6ES7 658-7BX21-2YA0 ............................... 2/3<br />

6ES7 658-7CX21-2YB0............................... 2/3<br />

6ES7 658-7DX06-0YA0 ...................... 4/14, 7/6<br />

6ES7 658-7EX06-0YB0 ............................... 7/6<br />

6ES7 658-7F................................................ 7/6<br />

6ES7 833-1CC00-0YX0.................. 4/11, 10/10<br />

6ES7 833-1CC00-6YX0........................... 10/10<br />

6ES7 833-1SM00-0YA5............................. 4/13<br />

6ES7 833-1SM40-0YA5............................. 4/13<br />

6ES7 833-1SM60-0YA5.................... 4/13, 5/13<br />

6ES7 833-2AC01-0YB0........... 4/8, 10/8, 10/10<br />

6ES7 841-0C............................................. 4/20<br />

6ES7 870-1.... ........................................... 9/21<br />

6ES7 900-..... ......................... 2/9, 5/6, 6/4, 7/4<br />

6ES7 902-1AB00-0AA0............................. 9/21<br />

6ES7 902-1AC00-0AA0 ............ 5/16, 6/4, 9/21<br />

6ES7 902-1AD00-0AA0 ............................ 9/21<br />

6ES7 902-2.... ........................................... 9/21<br />

6ES7 902-3.... ........................................... 9/21<br />

6ES7 952-1AK00-0AA0............................. 10/8<br />

6ES7 952-1AL00-0AA0 .................... 10/5, 10/8<br />

6ES7 952-1AM00-0AA0 ................... 10/5, 10/8<br />

6ES7 952-1AP00-0AA0.................... 10/5, 10/8<br />

6ES7 952-1AS00-0AA0.................... 10/5, 10/8<br />

6ES7 952-1KM00-0AA0 ................... 10/5, 10/8<br />

6ES7 955-2.... ........................................... 10/8<br />

6ES7 960-1.... ........................................... 10/8<br />

6ES7 964-2AA01-0AB0............................. 9/13<br />

6ES7 964-2AA04-0AB0............................. 10/5<br />

6ES7 971-0BA00.............................. 10/5, 10/8<br />

6ES7 972-0AA01-0XA0............................. 9/10<br />

6ES7 972-0AB01-0XA0............................. 9/10<br />

6ES7 972-0AC80-0XA0.................. 9/10, 11/23<br />

6ES7 972-0BA30-0XA0........................... 11/23<br />

6ES7 972-0BA50-0XA0............................. 9/10<br />

6ES7 972-0BB50-0XA0............................. 9/10<br />

6ES7 972-0DA00-0AA0 ............................ 9/10<br />

6ES7 972-0DA30-0XA0........................... 11/23<br />

6ES7 972-0DA30-0XA0............................. 9/10<br />

6ES7 998-8XC01-8YE0 ............................... 2/2<br />

6ES7 998-8XC01-8YE2 ............................... 2/2<br />

6GF6 100-1BA........................................... 2/11<br />

6GF6 100-1PC........................................... 2/11<br />

6GF6 180-1AH .......................................... 2/11<br />

6GF6 710-1AA.......... 2/9, 3/4, 4/3, 5/6, 6/4, 7/4<br />

6GF6 710-1BA.......... 2/9, 3/4, 4/3, 5/6, 6/4, 7/4<br />

6GK1 100-..... .............................................. 9/5<br />

6GK1 105-..... .............................................. 9/5<br />

6GK1 151-..... .............................................. 3/4<br />

6GK1 161-2A............................................... 9/8<br />

6GK1 161-3A............................... 5/6, 5/16, 9/8<br />

6GK1 415-0A............................................. 9/20<br />

6GK1 415-2A............................................. 9/19<br />

6GK1 500-0FC00 ...................................... 9/10<br />

6GK1 500-3AA00 ...................................... 9/12<br />

6GK1 502-3CB10 ...................................... 9/11<br />

6GK1 704-1.... ............................................. 9/8<br />

6GK1 716-0.... .................................... 5/16, 9/8<br />

6GK1 716-1.... ...................................... 5/6, 9/8<br />

6GK1 901-0CA00-0AA0 .............................. 9/6<br />

6GK1 901-0CA01-0AA0 .............................. 9/6<br />

6GK1 901-0DA20-0AA0 ..................... 9/6, 9/11<br />

6GK1 901-0FB00-0AA0............................. 9/12<br />

6GK1 901-1B............................................... 9/7<br />

6GK1 901-1G... ........................................... 9/7<br />

6GK1 905-0.... ........................................... 9/18<br />

6GK1 905-6A.................................... 9/10, 9/18<br />

6GK1 905-6P... .......................................... 9/12<br />

6GK1 970-..... .............................................. 9/7<br />

6GK1 971-2.... ........................................... 9/19<br />

6GK1 971-3.... ........................................... 9/20<br />

6GK7 343-..... ............................................ 9/19<br />

6GK7 443-1EX11-0XE0 ............. 9/8, 10/5, 10/8<br />

6GK7 443-5DX03-0XE0........... 9/13, 10/5, 10/8<br />

6XV1 820-........................................... 9/6, 9/11<br />

6XV1 821-.................................................. 9/12<br />

6XV1 830-0................................................ 9/10<br />

6XV1 830-5................................................ 9/18<br />

6XV1 840-2.................................................. 9/7<br />

6XV1 850-0.................................................. 9/6<br />

6XV2 175-.................................................... 5/7<br />

MSO:... ...................................................... 2/12<br />

Appendix<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

Order no. index<br />

13/11<br />

13


13<br />

■<br />

13/12<br />

Appendix<br />

<strong>Siemens</strong> ST PCS 7 · October 2004


■<br />

Appendix<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

13/13<br />

13


13<br />

Appendix<br />

Conditions of sale <strong>and</strong> delivery<br />

■ Terms <strong>and</strong> Conditions of Sale <strong>and</strong> Delivery<br />

By using this catalog you can acquire hardware <strong>and</strong> software<br />

products described therein from the <strong>Siemens</strong> AG subject to the<br />

following terms. Please note! The scope, the quality <strong>and</strong> the conditions<br />

for supplies <strong>and</strong> services, including software products,<br />

by any <strong>Siemens</strong> entity having a registered office outside of Germany,<br />

shall be subject exclusively to the General Terms <strong>and</strong><br />

Conditions of the respective <strong>Siemens</strong> entity.<br />

for customers with a seat or registered office in the<br />

Federal Republic of Germany<br />

The General Terms of Payment as well as the General Conditions<br />

for the Supply of Products <strong>and</strong> Services of the Electrical <strong>and</strong><br />

Electronics Industry shall apply.<br />

For software products, the General License Conditions for Software<br />

Products for <strong>Automation</strong> <strong>and</strong> <strong>Drives</strong> for Customers with<br />

Seat or registered Office in Germany shall apply.<br />

for customers with a seat or registered office outside of<br />

Germany<br />

The General Terms of Payment as well as the General Conditions<br />

for Supplies of <strong>Siemens</strong>, <strong>Automation</strong> <strong>and</strong> <strong>Drives</strong> for Customers<br />

with a Seat or registered Office outside of Germany shall apply.<br />

For software products, the General License Conditions for Software<br />

Products for <strong>Automation</strong> <strong>and</strong> <strong>Drives</strong> for Customers with<br />

Seat or registered Office outside of Germany shall apply.<br />

General<br />

The prices are in € (Euro) ex works, exclusive packaging.<br />

The sales tax (value added tax) is not included in the prices.<br />

It shall be debited separately at the respective rate according to<br />

the applicable legal regulations.<br />

In addition to the prices of products which include silver <strong>and</strong>/or<br />

copper, surcharges may be calculated if the respective limits of<br />

the notes are exceeded.<br />

Prices are subject to change without prior notice. We will debit<br />

the prices valid at the time of delivery.<br />

The dimensions are in mm. Illustrations are not binding.<br />

Insofar as there are no remarks on the corresponding pages,<br />

- especially with regard to data, dimensions <strong>and</strong> weights given -<br />

these are subject to change without prior notice.<br />

Comprehensive Terms <strong>and</strong> Conditions of Sale <strong>and</strong> Delivery are<br />

available free of charge from your local <strong>Siemens</strong> business office<br />

under the following Order Nos.:<br />

6ZB5310-0KR30-0BA0<br />

(for customers based in the Federal Republic of Germany)<br />

6ZB5310-0KS53-0BA0<br />

(for customers based outside of theFederal Republic of<br />

Germany)<br />

or download them from the Internet:<br />

www.siemens.com/automation/mall<br />

(Germany: A&D Mall Online-Help <strong>System</strong>)<br />

Published by <strong>Siemens</strong> AG<br />

<strong>Automation</strong> <strong>and</strong> <strong>Drives</strong><br />

Industrial <strong>Automation</strong> <strong>System</strong>s<br />

Postfach 48 48,<br />

90327 NÜRNBERG<br />

FEDERAL REPUBLIC OF GERMANY<br />

13/14<br />

<strong>Siemens</strong> ST PCS 7 · October 2004<br />

■ Export regulations<br />

The products listed in this catalog / price list may be subject to<br />

European / German <strong>and</strong>/or US export regulations.<br />

Therefore, any export requiring a license is subject to approval<br />

by the competent authorities.<br />

According to current provisions, the following export regulations<br />

must be observed with respect to the products featured in this<br />

catalog / price list:<br />

AL Number of the German Export List.<br />

Products marked other than “N“ require an export<br />

license.<br />

In the case of software products, the export designations<br />

of the relevant data medium must also<br />

be generally adhered to.<br />

Goods labeled with an “AL not equal to N“ are<br />

subject to a European or German export authorization<br />

when being exported out of the EU.<br />

ECCN Export Control Classification Number.<br />

Products marked other than “N“ are subject to a<br />

reexport license to specific countries.<br />

In the case of software products, the export<br />

designations of the relevant data medium must<br />

also be generally adhered to.<br />

Goods labeled with an “ECCN not equal to N“ are<br />

subject to a US re-export authorization.<br />

Even without a label or with an “AL: N“ or “ECCN: N“, authorization<br />

may be required due to the final destination <strong>and</strong> purpose for<br />

which the goods are to be used.<br />

The deciding factors are the AL or ECCN export authorization<br />

indicated on order confirmations, delivery notes <strong>and</strong> invoices.<br />

Errors excepted <strong>and</strong> subject to change without prior notice.<br />

Online-Edition, Order No.<br />

E86060-W4678-A111-A8-7600<br />

KG K 1004 x.x x 178 En/ 415172 / IWI: TSTP<br />

Printed in the Federal Republic of Germany<br />

A&D/VuL/En 14.11.03


<strong>Automation</strong> <strong>and</strong> <strong>Drives</strong><br />

Interactive catalog on CD-ROM<br />

Catalog<br />

The Offline Mall of <strong>Automation</strong> <strong>and</strong> <strong>Drives</strong> CA 01<br />

<strong>Automation</strong> <strong>System</strong>s for Machine Tools<br />

SINUMERIK & SIMODRIVE NC 60<br />

Drive <strong>System</strong>s<br />

Variable-Speed <strong>Drives</strong><br />

SINAMICS G130 Drive Converter Chassis Units<br />

SINAMICS G150 Drive Converter Cabinet Units<br />

D11<br />

SINAMICS G110 Inverter Chassis Units D11.1<br />

SINAMICS S120 Servo Control Drive <strong>System</strong> D21.2<br />

SINAMICS S150 Drive Converter Cabinet Units D21.3<br />

DC Motors DA 12<br />

SIMOREG DC MASTER 6RA70 Digital Chassis<br />

Converters<br />

DA 21.1<br />

SIMOREG K 6RA22 Analog Chassis Converters DA 21.2<br />

SIMOREG DC MASTER 6RM70 Digital Converter<br />

Cabinet Units<br />

DA 22<br />

SIMOVERT PM Modular Converter <strong>System</strong>s DA 45<br />

SIEMOSYN Motors DA 48<br />

MICROMASTER 410/420/430/440 Inverters DA 51.2<br />

MICROMASTER 411/COMBIMASTER 411 DA 51.3<br />

SIMOVERT MV Medium-Voltage <strong>Drives</strong> DA 63<br />

SIMOVERT MASTERDRIVES Vector Control DA 65.10<br />

SIMOVERT MASTERDRIVES Motion Control DA 65.11<br />

Synchronous <strong>and</strong> asynchronous servomotors for<br />

SIMOVERT MASTERDRIVES<br />

DA 65.3<br />

SIMODRIVE 611 universal <strong>and</strong> POSMO<br />

Low-Voltage Three-Phase-Motors<br />

DA 65.4<br />

Squirrel-Cage Motors, Totally Enclosed, Fan-Cooled M 11<br />

<strong>Automation</strong> <strong>System</strong>s for Machine Tools SIMODRIVE<br />

Main Spindle Motors<br />

Feed Motors<br />

Converter <strong>System</strong>s SIMODRIVE 611/POSMO<br />

NC 60<br />

Drive <strong>and</strong> Control Components for Hoisting Equipment HE 1<br />

Electrical Installation Technology<br />

PDF: ALPHA Small Distribution Boards <strong>and</strong><br />

Distribution Boards<br />

ET A1<br />

PDF: ALPHA Side-by-Side Switchgear Cabinets ET A3<br />

PDF: ALPHA FIX Terminal Blocks ET A5<br />

PDF: BETA Modular Installation Devices ET B1<br />

PDF: DELTA Switches <strong>and</strong> Outlets ET D1<br />

PDF: GAMMA Building Management <strong>System</strong>s ET G1<br />

Factory <strong>Automation</strong> Sensors FS 10<br />

Human Machine Interface <strong>System</strong>s SIMATIC HMI ST 80<br />

Industrial Communication for<br />

<strong>Automation</strong> <strong>and</strong> <strong>Drives</strong><br />

PDF: These catalogs are only available as pdf files.<br />

IK PI<br />

Catalogs of the<br />

<strong>Automation</strong> <strong>and</strong> <strong>Drives</strong> <strong>Group</strong> (A&D)<br />

Further information can be obtained from our<br />

branch offices listed in the appendix of this catalog<br />

Low-Voltage Controls <strong>and</strong> Distribution Catalog<br />

Low-Voltage Switchgear – Controlgear for Industry LV 10<br />

Power Distribution – Products <strong>and</strong> <strong>System</strong>s<br />

for Low-Voltage Power Distribution<br />

LV 30<br />

SIDAC-D reactors <strong>and</strong> SIDAC-F filters LV 63<br />

SIVACON 8PS Busbar Trunking <strong>System</strong>s<br />

CD, BD01, BD2 up to 1250 A<br />

LV 70<br />

Busbar trunking systems LDA/LDC LV 71<br />

Busbar trunking systems LXA/LXC LV 72<br />

SENTRON WL NS WL<br />

Motion Control <strong>System</strong> SIMOTION PM 10<br />

Process Instrumentation <strong>and</strong> Analytics<br />

Field Instruments for Process <strong>Automation</strong><br />

Measuring Instruments for Pressure,<br />

Differential Pressure, Flow, Level <strong>and</strong> Temperature,<br />

Positioners <strong>and</strong> Liquid Meters<br />

FI 01<br />

PDF: Indicators for panel mounting MP 12<br />

SIREC Recorders <strong>and</strong> Accessories MP 20<br />

SIPART, Controllers <strong>and</strong> Software MP 31<br />

SIWAREX Weighing <strong>System</strong>s WT 01<br />

Continuous Weighing <strong>and</strong> Process Protection WT 02<br />

Gas Analysis Equipment for the Process Industry PA 10<br />

PDF: Process Analytics,<br />

Components for the <strong>System</strong> Integration<br />

PA 11<br />

SIPAN Liquid Analysis PA 20<br />

SIMATIC Industrial <strong>Automation</strong> <strong>System</strong>s<br />

SIMATIC PCS Process Control <strong>System</strong> ST 45<br />

PDF: SIMATIC S5/505 <strong>Automation</strong> <strong>System</strong>s ST 50<br />

Components for Totally Integrated <strong>Automation</strong> <strong>and</strong><br />

Micro <strong>Automation</strong><br />

ST 70<br />

SIMATIC PCS 7 Process Control <strong>System</strong> ST PCS 7<br />

PDF: Add-ons for the SIMATIC PCS 7<br />

Process Control <strong>System</strong><br />

ST PCS 7.A<br />

SIMATIC Control <strong>System</strong>s ST DA<br />

SIPOS Electric Actuators<br />

Electric Rotary, Linear <strong>and</strong> Part-turn Actuators MP 35<br />

Electric Rotary Actuators for Nuclear Plants MP 35.1/.2<br />

<strong>System</strong>s <strong>Engineering</strong><br />

Power supplies SITOP power KT 10.1<br />

<strong>System</strong> cabling SIMATIC TOP connect KT 10.2<br />

<strong>System</strong> Solutions<br />

Applications <strong>and</strong> Products for Industry are part of the<br />

interactive catalog CA 01<br />

TELEPERM M Process Control <strong>System</strong><br />

AS 235, AS 235H <strong>and</strong> AS 235K automation systems PLT 111<br />

PDF: AS 488/TM automation systems PLT 112<br />

Operating <strong>and</strong> monitoring with WinCC/TM PLT 123<br />

CS 275 bus system PLT 130<br />

A&D/3U/En 28.09.04


The information provided in this catalog contains descriptions<br />

or characteristics of performance which in case of actual use<br />

do not always apply as described or which may change as a<br />

result of further development of the products. An obligation<br />

to provide the respective characteristics shall only exist if<br />

expressly agreed in the terms of contract. Availability <strong>and</strong><br />

technical specifications are subject to change without notice.<br />

<strong>Siemens</strong> AG<br />

<strong>Automation</strong> <strong>and</strong> <strong>Drives</strong><br />

Industrial <strong>Automation</strong> <strong>System</strong>s<br />

FEDERAL REPUBLIC OF GERMANY<br />

www.siemens.com/simatic-pcs7 Order No. E86060-W4678-A111-A8-7600