Responses<br />

When a range of devices is listed on the comm<strong>and</strong> line, only devices that have<br />

query information available are shown. Errors messages are not issued for<br />

individual devices within the range. For example:<br />

query paths to 100-105<br />

Device 0105, Status OFFLINE<br />

CHPIDs to Device 0105 (PIM) : 19 1B 2E 2F<br />

Physically Available (PAM) : + + + +<br />

Online (LPM) : + + + +<br />

Ready;<br />

Legend + Yes - No<br />

If query information is not available for at least one device in a range, then a<br />

generic error message will be issued. For example:<br />

query paths to 100-102<br />

H<strong>CP</strong>QPA1003E 0100-0102 was not found.<br />

Ready(01003);<br />

Response 1 (Generic):<br />

The following is the full, generic response to the QUERY PATHS comm<strong>and</strong>.<br />

Normally, you will see only pieces of this response, as <strong>CP</strong> displays only the lines<br />

that have data. For example, if the device does not have any offline channel paths,<br />

<strong>CP</strong> would not display lines 5 through 9. The maximum number of channel paths is<br />

8, as shown in the example. <strong>CP</strong> displays only the number of channel paths<br />

attached to the device. The responses that follow this generic one will show<br />

examples of these shortened responses.<br />

1 Device rdev, Status status<br />

2 CHPIDs to Device rdev (PIM) : chpid1 .......... chpid8<br />

3 Physically Available (PAM) : +/- +/-<br />

4 Online (LPM) : +/- +/-<br />

5 Offline by Authorized User : +/- +/-<br />

6 Offline by ESCON Manager : +/- +/-<br />

7 Out of Path Group by Guest : +/- +/-<br />

8 Offline by Control Unit : +/- +/-<br />

9 Offline, Wrong CU Connection: +/- +/-<br />

10 Legend + Yes - No<br />

Line Explanations<br />

QUERY PATHS<br />

1 tells you the real device number of the device <strong>and</strong> its status. The status<br />

field can contain the following:<br />

BOXED<br />

device is not available to <strong>CP</strong>, usually because of a hardware<br />

condition<br />

DISABLE<br />

device is disabled<br />

ENABLE<br />

device is enabled<br />

OFFLINE<br />

device is offline<br />

ONLINE<br />

device is online<br />

QUIESCED<br />

device is offline for maintenance<br />

Chapter 2. <strong>CP</strong> <strong>Comm<strong>and</strong>s</strong> 919