SUSPENDED<br />

indicates that SAMPLE monitoring is suspended because monitor is running<br />

in exclusive mode <strong>and</strong> the user connected is quiesced. (If the user is<br />

quiesced before the start comm<strong>and</strong> is issued, the monitor is in a PENDING<br />

state.)<br />

PENDING<br />

indicates that SAMPLE monitoring is not being performed because there is<br />

no eligible monitor user to receive data notification for sample data.<br />

INTERVALnMINUTES<br />

INTERVALnSECONDS<br />

describes the current monitor sampling interval, where n is the current interval<br />

value (1 through 60 for minutes, 6 through 3600 for seconds). If an INTERVAL<br />

value does not fall on a whole minute, the value is displayed in seconds, <strong>and</strong><br />

the suffix SECONDS is displayed.<br />

PENDING INTERVALnMINUTES<br />

PENDING INTERVALnSECONDS<br />

indicates that a new sampling interval is to take effect after the current sampling<br />

interval has occurred. If the new INTERVAL value does not fall on a whole<br />

minute, the value is displayed in seconds, <strong>and</strong> the suffix SECONDS is<br />

displayed.<br />

RATE n SECONDS<br />

RATE STOP<br />

describes the current monitor high-frequency sampling rate, where n is a value<br />

between 0.01 <strong>and</strong> 30 seconds. STOP indicates that high-frequency sampling is<br />

inactive.<br />

PENDING RATE n SECONDS<br />

PENDING RATE STOP<br />

indicates that a new high-frequency sampling rate is to take effect after the<br />

current high-frequency sampling rate has occurred; n is a value between 0.01<br />

<strong>and</strong> 30 seconds. STOP indicates that high-frequency sampling is inactive when<br />

the current RATE expires.<br />

MONITOR DCSS NAME<br />

provides the name of the DCSS that is to collect monitor data.<br />

dcssname<br />

is the name of the DCSS being used.<br />

NO DCSS NAME DEFINED<br />

indicates that no DCSS name is defined.<br />

indicates the number of 4 KB pages (within the sample portion of the DCSS)<br />

allocated for sample configuration records. Leading zeros, if any, are removed.<br />

LIMITnMINUTES<br />

LIMITnSECONDS<br />

displays the time limit in which a reply is required to the configuration IUCV<br />

message. If the value does not fall on a whole minute, the value is displayed in<br />

seconds, <strong>and</strong> the suffix SECONDS is displayed. Leading zeros, if any, are<br />

removed.<br />

CONFIGURATION AREA WILL BE FREED WITHIN -nMINUTESnSECONDS<br />

displays the amount of time that the users holding the configuration area have<br />

left to reply to the configuration IUCV message.<br />

CONFIGURATION AREA IS FREE<br />

is displayed if no users are holding the configuration area.<br />

QUERY MONITOR<br />

Chapter 2. <strong>CP</strong> <strong>Comm<strong>and</strong>s</strong> 885