27.12.2012 Views

z/VM: CP Commands and Utilities Reference - z/VM - IBM

z/VM: CP Commands and Utilities Reference - z/VM - IBM

z/VM: CP Commands and Utilities Reference - z/VM - IBM

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

QUERY LOADDEV<br />

QUERY LOADDEV<br />

►►<br />

Query<br />

Authorization<br />

Purpose<br />

LOADDEV<br />

Responses<br />

Privilege Class: G<br />

854 z/<strong>VM</strong>: <strong>CP</strong> <strong>Comm<strong>and</strong>s</strong> <strong>and</strong> <strong>Utilities</strong> <strong>Reference</strong><br />

Use Query LOADDEV to display parameters previously defined with SET<br />

LOADDEV or the LOADDEV directory statement.<br />

LOADDEV parameters identify the location of a program to be loaded as a result of<br />

a guest IPL from SCSI disk.<br />

PORTNAME hhhhhhhh hhhhhhhh LUN hhhhhhhh hhhhhhhh BOOTPROG n<br />

BR_LBA hhhhhhhh hhhhhhhh<br />

The following lines will only appear if hex S<strong>CP</strong>DATA has been defined:<br />

S<strong>CP</strong>DATA<br />

00----03 04----07 08----11 12----15 16----19<br />

0000 hhhhhhhh hhhhhhhh hhhhhhhh hhhhhhhh hhhhhhhh<br />

0020 hhhhhhhh hhhhhhhh hhhhhhhh hhhhhhhh hhhhhhhh<br />

0040 hhhhhhhh hhhhhhhh hhhhhhhh hhhhhhhh hhhhhhhh<br />

.<br />

.<br />

.<br />

The following lines will only appear if text S<strong>CP</strong>DATA has been defined:<br />

S<strong>CP</strong>DATA<br />

0----+----1----+----2----+----3----+----4----+----<br />

0000 tttttttttttttttttttttttttttttttttttttttttttttttttt<br />

0050 tttttttttttttttttttttttttttttttttttttttttttttttttt<br />

0100 tttttttttttttttttttttttttttttttttttttttttttttttttt<br />

.<br />

.<br />

.<br />

PORTNAME hhhhhhhh hhhhhhhh<br />

The hexadecimal 8-byte fibre channel port name of the F<strong>CP</strong>-I/O device.<br />

LUN hhhhhhhh hhhhhhhh<br />

The hexadecimal 8-byte logical unit number of the F<strong>CP</strong>-I/O device.<br />

BOOTPROG n<br />

The decimal value between 0 <strong>and</strong> 30 specifying the program to be loaded<br />

from the F<strong>CP</strong>-I/O device.<br />

BR_LBA hhhhhhhh hhhhhhhh<br />

The hexadecimal logical-block address of the boot record of the F<strong>CP</strong>-I/O<br />

device.<br />

S<strong>CP</strong>DATA<br />

Designates information to be passed to the program to be loaded during a<br />

guest IPL. It is displayed in the same format (text or hex) as it was entered.<br />

►◄