27.12.2012 Views

z/VM: CP Commands and Utilities Reference - z/VM - IBM

z/VM: CP Commands and Utilities Reference - z/VM - IBM

z/VM: CP Commands and Utilities Reference - z/VM - IBM

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

QUERY DASD<br />

Messages<br />

volume operates as a PPRC Extended Distance primary volume, sending to a<br />

tertiary volume many miles away. Such a configuration supports disaster<br />

recovery operations.<br />

If the queried DASD is not an active PPRC volume the PPRC DETAILS line is not<br />

included in the response.<br />

Response 8:<br />

H<strong>CP</strong>002E Invalid oper<strong>and</strong> - oper<strong>and</strong><br />

H<strong>CP</strong>003E Invalid option - option<br />

H<strong>CP</strong>006E Invalid device type - rdev<br />

H<strong>CP</strong>009E Invalid range - range<br />

H<strong>CP</strong>020E Userid missing or invalid<br />

H<strong>CP</strong>021E A real device number was not<br />

specified or it is invalid.<br />

H<strong>CP</strong>040E Device rdev does not exist<br />

If you enter QUERY DASD DETAILS for an FBA DASD, such as a 9336 model 20,<br />

you see something like this:<br />

query dasd details 600<br />

0600 CUTYPE = 6310-80, DEVTYPE = 9336-10, VOLSER = L3RES, CYLS = 16<br />

BLKS = 34504<br />

Ready;<br />

This response tells you the DASD at real device number 600 has a control unit type<br />

of 6310-80, a device type of 9336-10, a volume serial number of L3RES, <strong>and</strong><br />

contains 34,504 512-byte blocks. The number of cylinders displayed (e.g., CYLS =<br />

16) is a calculated value derived from:<br />

total number of blocks / number of blocks per access position<br />

For the control unit type <strong>and</strong> the device type, the last two digits of each are hex<br />

codes for the associated models. See the device documentation to determine the<br />

models for the hex codes given.<br />

H<strong>CP</strong>263E Too many oper<strong>and</strong>s were supplied for<br />

this comm<strong>and</strong>.<br />

H<strong>CP</strong>332E Invalid control unit type - rdev<br />

772 z/<strong>VM</strong>: <strong>CP</strong> <strong>Comm<strong>and</strong>s</strong> <strong>and</strong> <strong>Utilities</strong> <strong>Reference</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!