52 z/<strong>VM</strong>: <strong>CP</strong> <strong>Comm<strong>and</strong>s</strong> <strong>and</strong> <strong>Utilities</strong> <strong>Reference</strong><br />

For example, if you specify COPY 4 <strong>and</strong> FLASH name 2, the first two copies of<br />

your file are flashed, whereas the last two copies remain unflashed. If ALL is<br />

specified, the flash count always matches the copy count. ALL is the default.<br />

FLash OFF<br />

resets the flash parameters. Blanks are inserted into the flash name field of the<br />

specified spool files, <strong>and</strong> the count is set to 0.<br />

MOdify name n<br />

assigns a copy modification module to be used when printing the spool files on<br />

the 3800. This function makes it possible to alter text by either preventing the<br />

printing of certain information or by adding labels to output. The name must be<br />

one to four characters.<br />

The n variable selects one of the character sets specified by the CHARS<br />

oper<strong>and</strong> to be used for the copy modification text. The values 0, 1, 2, or 3<br />

correspond to the order in which the character sets have been specified. If no n<br />

is specified, the first character set (0) is assumed.<br />

MOdify OFF<br />

resets the modify parameters. Blanks are inserted into the modify name field of<br />

the spool files <strong>and</strong>, when printing takes place, no modification occurs. The<br />

modify number (n) is set to 0.<br />

FCB name<br />

FCB 6<br />

FCB 8<br />

FCB 10<br />

FCB 12<br />

specifies the forms control buffer to be used when printing the file on the 3800<br />

printer. The name variable is a 1- to 4-character name of an FCB image, or the<br />

number 6, 8, 10, or 12. The number tells the 3800 to print the entire spool file<br />

at 6, 8, 10, or 12 lines to the inch, regardless of the size of the paper currently<br />

loaded. Using these unique numbers assures that printed material fits onto a<br />

specified page size. Note, however, that FCB 10 prints only on a 3800 Model 3<br />

printer.<br />

FCB OFF<br />

resets the FCB parameter. Blanks are inserted into the FCB name field of the<br />

spool file or files <strong>and</strong>, when the file is printed, a default FCB controls the vertical<br />

spacing of the output text.<br />

CHars name<br />

CHars name CHars name<br />

specifies the name of the character set or sets used to print the spool file or<br />

files on a 3800 printer. The name or names must be from one to four characters<br />

with a maximum of four names specified. You need to use CHARS more than<br />

once only if nameN is the same as an option name (for example, FORM) or<br />

with a user ID. If more than one name is specified, <strong>and</strong> modification is also<br />

specified, the order in which the names appear determines the table used for<br />

copy modification text.<br />

CHars OFF<br />

resets the CHARS parameters. Blanks are inserted into the name fields of the<br />

character sets used for output generation. The spool files, therefore, use a<br />

default character set when actually printed.<br />

SEClabel ssssssss<br />

assigns a security label to the chosen files. ssssssss is the security label to be