27.12.2012 Views

z/VM: CP Commands and Utilities Reference - z/VM - IBM

z/VM: CP Commands and Utilities Reference - z/VM - IBM

z/VM: CP Commands and Utilities Reference - z/VM - IBM

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

- or -<br />

MONITOR SAMPLE STARTED BY [userid] -- RECORDING IS ACTIVATED.<br />

As a result of the MONITOR START comm<strong>and</strong>, sample monitoring has successfully<br />

started. There is at least one user with an active path connected to *MONITOR for<br />

sample data collection.<br />

MONITOR SAMPLE STARTED -- RECORDING IS PENDING.<br />

- or -<br />

MONITOR SAMPLE STARTED BY [userid] -- RECORDING IS PENDING.<br />

MONITOR START has been issued. Because there is no user with an active path<br />

connected to *MONITOR for sample data collection, sample monitoring is held<br />

pending. It shall remain pending until the first user is connected to *MONITOR for<br />

sample data collection.<br />

MONITOR EVENT STARTED -- RECORDING IS ACTIVATED.<br />

- or -<br />

MONITOR EVENT STARTED BY [userid] -- RECORDING IS ACTIVATED.<br />

As a result of the MONITOR START comm<strong>and</strong>, event monitoring has successfully<br />

started. There is at least one user with an active path connected to *MONITOR for<br />

event data collection.<br />

MONITOR EVENT STARTED -- RECORDING IS PENDING.<br />

- or -<br />

MONITOR EVENT STARTED BY [userid] -- RECORDING IS PENDING.<br />

MONITOR START has been issued. Because there is no user with an active path<br />

connected to *MONITOR for event data collection, event monitoring is held pending.<br />

It shall remain pending until the first user is connected to *MONITOR for event data<br />

collection.<br />

Notes:<br />

1. Only one of the above responses is displayed for sample monitoring; another is<br />

displayed for event monitoring. Depending on the profile set up for monitoring,<br />

one or the other, or both, will be displayed.<br />

2. These responses are sent to the user that issued the comm<strong>and</strong>. If this user is<br />

not the system operator, the responses containing [userid] are also sent to the<br />

system operator.<br />

Response 2:<br />

MONITOR SAMPLE STOPPED<br />

- or -<br />

MONITOR SAMPLE STOPPED BY [userid]<br />

As a result of the MONITOR STOP comm<strong>and</strong>, sample monitoring has been<br />

stopped.<br />

MONITOR EVENT STOPPED<br />

- or -<br />

MONITOR EVENT STOPPED BY [userid]<br />

MONITOR START/STOP<br />

Chapter 2. <strong>CP</strong> <strong>Comm<strong>and</strong>s</strong> 645

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!