MONITOR START/STOP<br />

►►<br />

MONitor<br />

Authorization<br />

Purpose<br />

Oper<strong>and</strong>s<br />

STArt<br />

STOP<br />

Usage Notes<br />

BLock<br />

BLock<br />

4<br />

m<br />

Privilege Class: A, E<br />

PARTition<br />

n<br />

Use the MONITOR START comm<strong>and</strong> to activate event <strong>and</strong> sample monitoring<br />

based on the profiles established by the preceding MONITOR EVENT <strong>and</strong><br />

MONITOR SAMPLE comm<strong>and</strong>s or by either one of those comm<strong>and</strong>s.<br />

Use the MONITOR STOP comm<strong>and</strong> to deactivate all monitoring.<br />

MONITOR START/STOP<br />

STArt<br />

activates event <strong>and</strong> sample monitoring based on the profiles established by the<br />

MONITOR EVENT <strong>and</strong> MONITOR SAMPLE comm<strong>and</strong>s. Event monitoring is<br />

started first.<br />

STOP<br />

deactivates the event <strong>and</strong> sample monitoring. The profiles for event <strong>and</strong> sample<br />

monitoring are not affected by this comm<strong>and</strong>, except for PARTITION which is<br />

set to zero. Event monitoring is stopped first.<br />

Note: Do not use this comm<strong>and</strong> to stop the MONWRITE utility. (See<br />

“MONWRITE” on page 1853 for more information.)<br />

BLock m<br />

specifies the number of 4 KB frames, m, of the shared segment that are<br />

accumulated before the virtual machine is notified that the event data is<br />

available for data collection. The BLOCK value may be modified using the<br />

MONITOR EVENT BLOCK comm<strong>and</strong> while event monitoring is active.<br />

PARTition n<br />

specifies the number of 4 KB frames, n, in the shared segment that are<br />

reserved for event records. The rest of the shared segment is then used for<br />

sample data.<br />

1. The MONITOR START comm<strong>and</strong> can be issued before or after a user connects<br />

to *MONITOR. If the MONITOR START comm<strong>and</strong> is issued <strong>and</strong> there is no<br />

connection to *MONITOR through an active path, monitor recording goes into a<br />

pending state. Monitor recording is not activated until there is a user connected<br />

with an active path (a path that is not quiesced at its IUCV message limit).<br />

The following must be done before monitor recording gets activated:<br />

v A saved segment must be defined <strong>and</strong> saved for the monitor<br />

►◄<br />

Chapter 2. <strong>CP</strong> <strong>Comm<strong>and</strong>s</strong> 643