MODIFY CU / CNTLUNIT<br />

Responses<br />

Messages<br />

3. After successfully entering this comm<strong>and</strong>, you will have changed the software’s<br />

view of the I/O configuration <strong>and</strong> part of the hardware’s view: the active I/O<br />

configuration in the hardware system area (HSA). You should also change the<br />

other part of the hardware’s view: the active I/O configuration data set (IOCDS)<br />

file on the support element (SE) hard disk.<br />

To change the IOCDS file on the SE hard disk, you must:<br />

a. Update the IO<strong>CP</strong> source file.<br />

b. Run the IO<strong>CP</strong> utility (see page 1849) against the updated IO<strong>CP</strong> file. If the<br />

IO<strong>CP</strong> utility runs without errors, it downloads the new IOCDS file to the SE<br />

hard disk.<br />

c. Issue the SET IOCDS_ACTIVE comm<strong>and</strong> (see page 1258) to make the new<br />

IOCDS file the active file that the processor will use during the next<br />

power-on reset (POR).<br />

4. For more information about changing control unit definitions in your I/O<br />

configuration, see z/<strong>VM</strong>: I/O Configuration.<br />

5. To define a new control unit on the system, use the DEFINE CU or CNTLUNIT<br />

comm<strong>and</strong>. (See page 149.)<br />

6. To delete an existing control unit on the system, use the DELETE CU or<br />

CNTLUNIT comm<strong>and</strong>. (See page 221.)<br />

Response 1:<br />

To add unit addresses X'01' through X'1F' to existing control unit 1200, enter the<br />

following:<br />

modify cu 1200 add unit_address 01-1f<br />

Control unit configuration change completed successfully<br />

Ready;<br />

Response 2:<br />

To add a link address of X'F4' <strong>and</strong> a control unit logical address of X'00' to channel<br />

path 19 on control unit 2F00, enter the following:<br />

mod cu 2f00 add chpid 19 escon link_addr f4 cu_logical_addr 00<br />

Control unit configuration change completed successfully<br />

Ready;<br />

Response 3:<br />

To add access to existing control unit 1210 from an additional channel-subsystem<br />

image, enter the following:<br />

mod cu 1210 css 3 add_css chpid 9 link 43 cuadd 81 man 2<br />

Control unit configuration change completed successfully<br />

Ready;<br />

H<strong>CP</strong>1006E Comm<strong>and</strong> processing cannot complete<br />

because the system does not support<br />

the logical-channel-subsystem facility.<br />

H<strong>CP</strong>6805E Cannot find RDEV for TYPE 1<br />

subchannel<br />

608 z/<strong>VM</strong>: <strong>CP</strong> <strong>Comm<strong>and</strong>s</strong> <strong>and</strong> <strong>Utilities</strong> <strong>Reference</strong><br />

H<strong>CP</strong>6806E Dynamic I/O change request [for<br />

channel path|for control unit|for<br />

device] failed with return code nnnn<br />

H<strong>CP</strong>6809E This processor does not support<br />

dynamic I/O changes

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!