INDICATE VECTOR<br />

►►<br />

INDicate<br />

Authorization<br />

Purpose<br />

Responses<br />

VECtor<br />

Privilege Class: C, E<br />

Use INDICATE VECTOR to display the names of active <strong>and</strong> loaded Vector Facility<br />

users.<br />

Active users are those virtual machines, on the dispatch or eligible lists, that used<br />

the Vector Facility during their last time slice. Loaded users are those whose vector<br />

status is loaded into a real Vector Facility at comm<strong>and</strong> execution time; these users<br />

are also listed, regardless of which list they are on.<br />

Response 1:<br />

Two lists of user IDs are displayed in response to the INDICATE VECTOR<br />

comm<strong>and</strong>. The ACTIVE VECTOR USERS list shows the user ID <strong>and</strong> virtual <strong>CP</strong>U<br />

address of each <strong>VM</strong>DBK that used the Vector Facility in its last time slice. The<br />

LOADED VECTOR USERS list shows the user ID <strong>and</strong> virtual <strong>CP</strong>U address for each<br />

<strong>VM</strong>DBK that has its virtual Vector Facility currently loaded in a real Vector Facility;<br />

this list also shows the address of the real Vector Facility on which the <strong>VM</strong>DBK is<br />

loaded. An example of this response is:<br />

ACTIVE VECTOR USERS<br />

MILLER 01, JONES 00, JONES 01, BROWN 00, BROWN 03<br />

COMPTEST 00, MVS2 01, MVS1 02<br />

LOADED VECTOR USERS<br />

JONES 00 ON <strong>CP</strong>U 01<br />

JONES 01 ON <strong>CP</strong>U 02<br />

SMITH 01 ON <strong>CP</strong>U 03<br />

In this example, user ID JONES is a virtual multiprocessor configuration with two<br />

virtual <strong>CP</strong>Us loaded into real Vector Facilities. User ID SMITH’s virtual <strong>CP</strong>U 01 has<br />

its virtual Vector Facility loaded in the real Vector Facility attached to real processor<br />

03.<br />

Response 2:<br />

NO ACTIVE VECTOR USERS<br />

is displayed when there are no recent Vector Facility users <strong>and</strong> when no user’s<br />

virtual Vector Facility is loaded into any real Vector Facility.<br />

Response 3:<br />

NO LOADED VECTOR USERS<br />

INDICATE VECTOR<br />

►◄<br />

Chapter 2. <strong>CP</strong> <strong>Comm<strong>and</strong>s</strong> 499