27.12.2012 Views

z/VM: CP Commands and Utilities Reference - z/VM - IBM

z/VM: CP Commands and Utilities Reference - z/VM - IBM

z/VM: CP Commands and Utilities Reference - z/VM - IBM

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

HYPERSWAP<br />

Usage Notes<br />

464 z/<strong>VM</strong>: <strong>CP</strong> <strong>Comm<strong>and</strong>s</strong> <strong>and</strong> <strong>Utilities</strong> <strong>Reference</strong><br />

RESume<br />

tells <strong>CP</strong> to perform the Resume function.<br />

rdev<br />

rdev.numDevs<br />

specifies a single real device (rdev) or a real device combined with a decimal<br />

range count (numDevs). A single value (rdev), a series (rdev rdev), a range<br />

(rdev.numDevs) or a combination of all can be entered. The device entered<br />

must be a hexidecimal real device number between X'0000' <strong>and</strong> X'FFFF'.<br />

VOLid volid<br />

tells <strong>CP</strong> to use a volume serial identifier. The value for volid is a 1 to 6<br />

character alphanumeric identifier. Only one volid can be entered.<br />

ALL<br />

specified on the Disable function to disable all real devices previously enabled<br />

for automatic quiesce processing.<br />

SWAP<br />

tells <strong>CP</strong> to perform the SWAP function.<br />

sourceRdev targetRdev<br />

sourceRdev.numDevs targetRdev<br />

specifies a single source real device (sourceRdev) <strong>and</strong> target real device<br />

(targetRdev) pair or source real device combined with a decimal range count<br />

(numDevs) <strong>and</strong> target real device range pair. A single source/target pair, a<br />

series of source/target pairs (sourceRdev targetRdev sourceRdev targetRdev),<br />

a range of source/target pairs (sourceRdev.numDevs targetRdev) or a<br />

combination of all can be entered. The devices entered must be hexidecimal<br />

real device numbers between X'0000' <strong>and</strong> X'FFFF'.<br />

VOLid sourceVolid targetVolid<br />

specifies a source volume serial identifier (sourceVolid) <strong>and</strong> target volume serial<br />

identifier (targetVolid) pair. Only one source/target pair can be entered.<br />

1. All real devices entered on the comm<strong>and</strong> must be DASD devices <strong>and</strong> either<br />

3380, 3390, or 9336 DASD types.<br />

2. The ENABLE function requires an Escon or Ficon attached ECKD 3990<br />

controller in support of 'PPRC' failover processing.<br />

3. The QUIESCE function requires the devices entered be in an online state.<br />

4. The SWAP function requires the state of the devices being swapped be either<br />

quiesced, offline or online, <strong>and</strong> free. An attempt will be made to VARY ON any<br />

offline devices.<br />

5. The SWAP function requires that the device pair be the same DASD type, have<br />

matching subclass information, be free of any active I/O <strong>and</strong> the target device’s<br />

size be at least as big as the source devices.<br />

6. When the SWAP function completes successfully for a device pair the source<br />

<strong>and</strong> target devices are left in a quiesce state.<br />

7. The RESUME function will only complete successfully on devices that are<br />

quiesced.<br />

8. Error messages will be issued for individual devices <strong>and</strong> device pairs for which<br />

the comm<strong>and</strong> processing fails, but the comm<strong>and</strong> processing continues for those<br />

devices that don’t fail.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!