XLINK DISPLAY<br />

Messages<br />

- or -<br />

-CYL- READ/WRITE FLAGS ON volid (CYL=c TRK=t<br />

RECL=l RECS=r SYSTEMS=s)<br />

ccccc mode sysname2 . . . . . . . . .<br />

. . . . . . . . . . . .<br />

. . . . . . . . . . . .<br />

----- NO LINK FLAGS ON THIS VOLUME<br />

volid<br />

identifies the volume identifier of the specified device.<br />

userid<br />

identifies the name of the user that formatted the CSE track on volume volid.<br />

sysname<br />

identifies the system that the CSE track for this volume was formatted from.<br />

c identifies the cylinder number where the CSE track was formatted.<br />

t identifies the track number of the CSE track.<br />

l identifies the number of cylinders made available for CSE use. For CKD<br />

devices it is also the length of the CSE map records.<br />

r identifies the number of CSE records written on the CSE track.<br />

s identifies the number of systems that can share this DASD volume.<br />

ccccc<br />

identifies the starting cylinder of an MDISK on volume vvvvvv that has link flags<br />

outst<strong>and</strong>ing by one or more systems.<br />

mode<br />

identifies the link mode, currently in effect for this MDISK by system sysname2.<br />

The possible mode values are:<br />

Read on<br />

Read-only access<br />

Write on<br />

Read <strong>and</strong> write access<br />

SRead on<br />

Read-only access <strong>and</strong> negates all write access requests.<br />

SWrite on<br />

Read <strong>and</strong> write access <strong>and</strong> negates all write access requests.<br />

ERead on<br />

Read-only access <strong>and</strong> negates all other access requests.<br />

EWrite on<br />

Read <strong>and</strong> write access <strong>and</strong> negates all other access requests.<br />

sysname2<br />

identifies the name of the system that has a read or write link to the MDISK that<br />

begins on cylinder ccccc.<br />

H<strong>CP</strong>2861E MISSING OR INVALID FUNCTION:<br />

subcomm<strong>and</strong><br />

H<strong>CP</strong>2862E VOLSER volid IS NOT A <strong>CP</strong><br />

FORMATTED VOLUME<br />

1888 z/<strong>VM</strong>: <strong>CP</strong> <strong>Comm<strong>and</strong>s</strong> <strong>and</strong> <strong>Utilities</strong> <strong>Reference</strong><br />

H<strong>CP</strong>2863E DIAG-A8 I/O ERROR, CC=n<br />

R15=hhhhhhhh SCSW=hhhhhhhh<br />

SENSE=hhhhhhhh